@@ -10,7 +10,7 @@ User Capacity: 80,000,000,000 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Sat Apr 9 08:26:42 2022 EDT
Local Time is: Sat Apr 9 09:31:35 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
@@ -18,7 +18,7 @@ APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
@@ -64,15 +64,15 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
3 Spin_Up_Time PO---- 178 160 021 - 2083
4 Start_Stop_Count -O--CK 099 099 000 - 1781
4 Start_Stop_Count -O--CK 099 099 000 - 1782
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-- 200 200 051 - 0
9 Power_On_Hours -O--CK 088 088 000 - 8870
9 Power_On_Hours -O--CK 088 088 000 - 8871
10 Spin_Retry_Count PO--C- 100 100 051 - 0
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 1776
190 Airflow_Temperature_Cel -O---K 080 040 045 Past 20
194 Temperature_Celsius -O---K 123 083 000 - 20
12 Power_Cycle_Count -O--CK 099 099 000 - 1777
190 Airflow_Temperature_Cel -O---K 078 040 045 Past 22
194 Temperature_Celsius -O---K 121 083 000 - 22
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--C- 200 200 000 - 0
198 Offline_Uncorrectable ----C- 200 200 000 - 0
@@ -127,7 +127,7 @@ SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: ? Celsius
Power Cycle Min/Max Temperature: --/20 Celsius
Power Cycle Min/Max Temperature: --/22 Celsius
Lifetime Min/Max Temperature: --/64 Celsius
SCT Temperature History Version: 2
@@ -135,7 +135,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 5/65 Celsius
Min/Max Temperature Limit: 1/70 Celsius
Temperature History Size (Index): 128 (23)
Temperature History Size (Index): 128 (33)
SCT Error Recovery Control:
Read: Disabled
@@ -148,6 +148,6 @@ Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x8000 4 52 Vendor specific
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x8000 4 61 Vendor specific