mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 538)
This commit is contained in:
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed May 22 12:41:47 2024 UTC
|
||||
Local Time is: Wed May 22 14:56:54 2024 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -70,13 +70,13 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 043 043 000 - 25253
|
||||
9 Power_On_Hours -O--C- 043 043 000 - 25254
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 56
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 39
|
||||
193 Load_Cycle_Count -O--C- 100 100 000 - 57
|
||||
194 Temperature_Celsius -O---- 206 206 000 - 29 (Min/Max 17/46)
|
||||
194 Temperature_Celsius -O---- 200 200 000 - 30 (Min/Max 17/46)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
@@ -130,8 +130,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/29 Celsius
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/30 Celsius
|
||||
Lifetime Min/Max Temperature: 17/46 Celsius
|
||||
Specified Max Operating Temperature: 32 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (109)
|
||||
Temperature History Size (Index): 128 (116)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -160,8 +160,8 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Tue May 21 11:22:44 2024 PDT
|
||||
Local Time is: Tue May 21 14:29:31 2024 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -70,7 +70,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate POSR-K 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--K 100 100 040 - 0
|
||||
9 Power_On_Hours -O--CK 095 095 000 - 2253
|
||||
9 Power_On_Hours -O--CK 095 095 000 - 2256
|
||||
10 Spin_Retry_Count PO--CK 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1209
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
@@ -78,7 +78,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
187 Reported_Uncorrect -O--CK 100 099 000 - 8257537
|
||||
188 Command_Timeout -O--CK 100 100 000 - 262145
|
||||
190 Airflow_Temperature_Cel -O---K 059 052 045 - 41 (Min/Max 38/48)
|
||||
191 G-Sense_Error_Rate -O--CK 094 094 000 - 1537
|
||||
191 G-Sense_Error_Rate -O--CK 094 094 000 - 1538
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 3014702
|
||||
193 Load_Cycle_Count -O--CK 074 074 000 - 265288
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (71)
|
||||
Temperature History Size (Index): 128 (2)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.0-STABLE amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p4 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Mar 19 21:29:03 2024 +03
|
||||
Local Time is: Fri Sep 13 00:15:42 2024 +03
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,21 +66,21 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--K 100 100 040 - 0
|
||||
3 Spin_Up_Time PO---K 230 100 033 - 1
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 5247
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 5655
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate POSR-K 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--K 100 100 040 - 0
|
||||
9 Power_On_Hours -O--CK 061 061 000 - 17149
|
||||
9 Power_On_Hours -O--CK 058 058 000 - 18541
|
||||
10 Spin_Retry_Count PO--CK 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 4360
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 4714
|
||||
183 Runtime_Bad_Block -O--CK 099 099 001 - 1
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 089 000 - 42973265959
|
||||
188 Command_Timeout -O--CK 100 097 000 - 266294329536
|
||||
190 Airflow_Temperature_Cel -O---K 078 054 045 - 22 (Min/Max 17/22)
|
||||
191 G-Sense_Error_Rate -O--CK 091 091 000 - 2457
|
||||
192 Power-Off_Retract_Count -O--CK 098 098 000 - 27066781
|
||||
193 Load_Cycle_Count -O--CK 070 070 000 - 306850
|
||||
187 Reported_Uncorrect -O--CK 100 089 000 - 42973265966
|
||||
188 Command_Timeout -O--CK 100 097 000 - 313539821760
|
||||
190 Airflow_Temperature_Cel -O---K 071 054 045 - 29 (Min/Max 24/31)
|
||||
191 G-Sense_Error_Rate -O--CK 091 091 000 - 2466
|
||||
192 Power-Off_Retract_Count -O--CK 098 098 000 - 27591077
|
||||
193 Load_Cycle_Count -O--CK 069 069 000 - 315102
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
@@ -110,7 +110,7 @@ Address Access R/W Size Description
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
Device Error Count: 37 (device log contains only the most recent 4 errors)
|
||||
Device Error Count: 44 (device log contains only the most recent 4 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
@@ -126,83 +126,84 @@ Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 37 [0] occurred at disk power-on lifetime: 15764 hours (656 days + 20 hours)
|
||||
Error 44 [3] occurred at disk power-on lifetime: 18180 hours (757 days + 12 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 41 00 08 00 00 00 00 08 a0 00 00 Error: WP at LBA = 0x000008a0 = 2208
|
||||
40 -- 41 00 08 00 00 00 00 08 20 00 00 Error: WP at LBA = 0x00000820 = 2080
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 05 40 00 d8 00 00 0d 5e bf 80 40 08 01:09:05.377 WRITE FPDMA QUEUED
|
||||
61 05 40 00 b8 00 00 0d 5e ba 40 40 08 01:09:05.371 WRITE FPDMA QUEUED
|
||||
61 05 40 00 b0 00 00 0d 5e b5 00 40 08 01:09:05.363 WRITE FPDMA QUEUED
|
||||
61 05 40 00 a8 00 00 0d 5e af c0 40 08 01:09:05.356 WRITE FPDMA QUEUED
|
||||
61 05 40 00 a0 00 00 0d 5e aa 80 40 08 01:09:05.348 WRITE FPDMA QUEUED
|
||||
61 05 40 00 f0 00 00 13 0a 43 40 40 08 00:44:52.872 WRITE FPDMA QUEUED
|
||||
61 05 40 00 e8 00 00 13 0a 3e 00 40 08 00:44:52.866 WRITE FPDMA QUEUED
|
||||
61 05 40 00 e0 00 00 13 0a 38 c0 40 08 00:44:52.858 WRITE FPDMA QUEUED
|
||||
61 05 40 00 d8 00 00 13 0a 33 80 40 08 00:44:52.852 WRITE FPDMA QUEUED
|
||||
61 05 40 00 d0 00 00 13 0a 2e 40 40 08 00:44:52.844 WRITE FPDMA QUEUED
|
||||
|
||||
Error 36 [3] occurred at disk power-on lifetime: 15740 hours (655 days + 20 hours)
|
||||
Error 43 [2] occurred at disk power-on lifetime: 18180 hours (757 days + 12 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 41 00 08 00 00 00 00 2f d0 00 00 Error: WP at LBA = 0x00002fd0 = 12240
|
||||
40 -- 41 00 08 00 00 07 47 38 b0 07 00 Error: WP at LBA = 0x074738b0 = 122108080
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 05 40 00 18 00 00 28 f8 f9 20 40 08 1d+14:14:21.951 WRITE FPDMA QUEUED
|
||||
61 05 40 00 10 00 00 28 f8 f3 e0 40 08 1d+14:14:21.944 WRITE FPDMA QUEUED
|
||||
61 05 40 00 08 00 00 28 f8 ee a0 40 08 1d+14:14:21.934 WRITE FPDMA QUEUED
|
||||
61 05 40 00 00 00 00 28 f8 e9 60 40 08 1d+14:14:21.925 WRITE FPDMA QUEUED
|
||||
61 05 40 00 f8 00 00 28 f8 e4 20 40 08 1d+14:14:21.917 WRITE FPDMA QUEUED
|
||||
61 05 40 00 00 00 00 12 a5 e2 e8 40 08 00:44:11.517 WRITE FPDMA QUEUED
|
||||
61 05 40 00 f0 00 00 12 a5 dd a8 40 08 00:44:11.509 WRITE FPDMA QUEUED
|
||||
61 05 40 00 e8 00 00 12 a5 d8 68 40 08 00:44:11.503 WRITE FPDMA QUEUED
|
||||
61 05 40 00 e0 00 00 12 a5 d3 28 40 08 00:44:11.495 WRITE FPDMA QUEUED
|
||||
61 05 40 00 d8 00 00 12 a5 cd e8 40 08 00:44:11.489 WRITE FPDMA QUEUED
|
||||
|
||||
Error 35 [2] occurred at disk power-on lifetime: 15740 hours (655 days + 20 hours)
|
||||
Error 42 [1] occurred at disk power-on lifetime: 18180 hours (757 days + 12 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 41 00 08 00 00 00 00 2f 28 00 00 Error: WP at LBA = 0x00002f28 = 12072
|
||||
40 -- 41 00 08 00 00 07 47 38 58 07 00 Error: WP at LBA = 0x07473858 = 122107992
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 05 40 00 d8 00 00 28 4a cf 80 40 08 1d+14:13:04.108 WRITE FPDMA QUEUED
|
||||
61 05 40 00 d0 00 00 28 4a ca 40 40 08 1d+14:13:04.099 WRITE FPDMA QUEUED
|
||||
61 05 40 00 c8 00 00 28 4a c5 00 40 08 1d+14:13:04.091 WRITE FPDMA QUEUED
|
||||
61 05 40 00 c0 00 00 28 4a bf c0 40 08 1d+14:13:04.081 WRITE FPDMA QUEUED
|
||||
61 05 40 00 b8 00 00 28 4a ba 80 40 08 1d+14:13:04.072 WRITE FPDMA QUEUED
|
||||
61 05 40 00 c8 00 00 12 79 fd a8 40 08 00:43:54.082 WRITE FPDMA QUEUED
|
||||
61 05 40 00 c0 00 00 12 79 f8 68 40 08 00:43:54.076 WRITE FPDMA QUEUED
|
||||
61 05 40 00 b8 00 00 12 79 f3 28 40 08 00:43:54.068 WRITE FPDMA QUEUED
|
||||
61 05 40 00 b0 00 00 12 79 ed e8 40 08 00:43:54.062 WRITE FPDMA QUEUED
|
||||
61 05 40 00 a8 00 00 12 79 e8 a8 40 08 00:43:54.054 WRITE FPDMA QUEUED
|
||||
|
||||
Error 34 [1] occurred at disk power-on lifetime: 15740 hours (655 days + 20 hours)
|
||||
Error 41 [0] occurred at disk power-on lifetime: 18180 hours (757 days + 12 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 41 00 08 00 00 00 00 2e e0 00 00 Error: WP at LBA = 0x00002ee0 = 12000
|
||||
40 -- 41 00 68 00 00 07 47 38 50 07 00 Error: WP at LBA = 0x07473850 = 122107984
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 05 40 00 38 00 00 27 ff 80 40 40 08 1d+14:12:31.993 WRITE FPDMA QUEUED
|
||||
61 05 40 00 30 00 00 27 ff 7b 00 40 08 1d+14:12:31.984 WRITE FPDMA QUEUED
|
||||
61 05 40 00 28 00 00 27 ff 75 c0 40 08 1d+14:12:31.974 WRITE FPDMA QUEUED
|
||||
61 05 40 00 20 00 00 27 ff 70 80 40 08 1d+14:12:31.967 WRITE FPDMA QUEUED
|
||||
61 05 40 00 18 00 00 27 ff 6b 40 40 08 1d+14:12:31.957 WRITE FPDMA QUEUED
|
||||
61 05 40 00 40 00 00 12 55 53 80 40 08 00:43:40.095 WRITE FPDMA QUEUED
|
||||
61 05 40 00 38 00 00 12 55 4e 40 40 08 00:43:40.087 WRITE FPDMA QUEUED
|
||||
61 05 40 00 30 00 00 12 55 49 00 40 08 00:43:40.081 WRITE FPDMA QUEUED
|
||||
61 05 40 00 28 00 00 12 55 43 c0 40 08 00:43:40.074 WRITE FPDMA QUEUED
|
||||
61 05 40 00 20 00 00 12 55 3e 80 40 08 00:43:40.068 WRITE FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 1185 -
|
||||
# 2 Short offline Completed without error 00% 1161 -
|
||||
# 3 Short offline Completed without error 00% 1144 -
|
||||
# 4 Short offline Completed without error 00% 1109 -
|
||||
# 5 Short offline Completed without error 00% 1097 -
|
||||
# 6 Short offline Completed without error 00% 1058 -
|
||||
# 7 Short offline Completed without error 00% 1046 -
|
||||
# 1 Extended offline Completed without error 00% 17462 -
|
||||
# 2 Short offline Completed without error 00% 1185 -
|
||||
# 3 Short offline Completed without error 00% 1161 -
|
||||
# 4 Short offline Completed without error 00% 1144 -
|
||||
# 5 Short offline Completed without error 00% 1109 -
|
||||
# 6 Short offline Completed without error 00% 1097 -
|
||||
# 7 Short offline Completed without error 00% 1058 -
|
||||
# 8 Short offline Completed without error 00% 1046 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -218,8 +219,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 21 Celsius
|
||||
Power Cycle Min/Max Temperature: 17/22 Celsius
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/31 Celsius
|
||||
Lifetime Min/Max Temperature: 13/46 Celsius
|
||||
Specified Max Operating Temperature: 30 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -229,7 +230,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (24)
|
||||
Temperature History Size (Index): 128 (58)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Dec 11 02:40:08 2022 GMT
|
||||
Local Time is: Mon Dec 12 18:29:31 2022 GMT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,21 +66,21 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 077 062 - 0
|
||||
2 Throughput_Performance P-S--K 100 100 040 - 0
|
||||
3 Spin_Up_Time PO---K 125 100 033 - 2
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 1572
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 1574
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate POSR-K 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--K 100 100 040 - 0
|
||||
9 Power_On_Hours -O--CK 041 041 000 - 26275
|
||||
9 Power_On_Hours -O--CK 040 040 000 - 26313
|
||||
10 Spin_Retry_Count PO--CK 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1567
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1569
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 103079542784
|
||||
188 Command_Timeout -O--CK 100 100 000 - 12886802434
|
||||
190 Airflow_Temperature_Cel -O---K 062 047 045 - 38 (Min/Max 32/38)
|
||||
191 G-Sense_Error_Rate -O--CK 097 097 000 - 862
|
||||
190 Airflow_Temperature_Cel -O---K 068 047 045 - 32 (Min/Max 24/32)
|
||||
191 G-Sense_Error_Rate -O--CK 097 097 000 - 866
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 5242960
|
||||
193 Load_Cycle_Count -O--CK 081 081 000 - 190557
|
||||
193 Load_Cycle_Count -O--CK 081 081 000 - 190582
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
@@ -131,8 +131,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/38 Celsius
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/32 Celsius
|
||||
Lifetime Min/Max Temperature: 6/53 Celsius
|
||||
Specified Max Operating Temperature: 36 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (95)
|
||||
Temperature History Size (Index): 128 (77)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -161,10 +161,8 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 19 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Dec 5 06:31:17 2023 GMT
|
||||
Local Time is: Thu Dec 7 05:38:45 2023 GMT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,21 +66,21 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--K 100 100 040 - 0
|
||||
3 Spin_Up_Time PO---K 119 100 033 - 2
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 1175
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 1177
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate POSR-K 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--K 100 100 040 - 0
|
||||
9 Power_On_Hours -O--CK 062 062 000 - 16741
|
||||
9 Power_On_Hours -O--CK 062 062 000 - 16792
|
||||
10 Spin_Retry_Count PO--CK 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1171
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1173
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 069 049 045 - 31 (Min/Max 27/32)
|
||||
190 Airflow_Temperature_Cel -O---K 070 049 045 - 30 (Min/Max 29/31)
|
||||
191 G-Sense_Error_Rate -O--CK 097 097 000 - 954
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 2228258
|
||||
193 Load_Cycle_Count -O--CK 093 093 000 - 75659
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 2293795
|
||||
193 Load_Cycle_Count -O--CK 093 093 000 - 75697
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
@@ -130,8 +130,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/32 Celsius
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/31 Celsius
|
||||
Lifetime Min/Max Temperature: 12/51 Celsius
|
||||
Specified Max Operating Temperature: 30 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (119)
|
||||
Temperature History Size (Index): 128 (115)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -160,8 +160,8 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Jul 27 10:17:01 2021 BST
|
||||
Local Time is: Tue Jul 27 14:47:10 2021 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -77,7 +77,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 691495108609
|
||||
188 Command_Timeout -O--CK 100 100 000 - 8591966208
|
||||
190 Airflow_Temperature_Cel -O---K 062 047 045 - 38 (Min/Max 28/41)
|
||||
190 Airflow_Temperature_Cel -O---K 061 047 045 - 39 (Min/Max 28/41)
|
||||
191 G-Sense_Error_Rate -O--CK 096 096 000 - 1070
|
||||
192 Power-Off_Retract_Count -O--CK 099 099 000 - 13369548
|
||||
193 Load_Cycle_Count -O--CK 023 023 000 - 772542
|
||||
@@ -184,7 +184,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (38)
|
||||
Temperature History Size (Index): 128 (52)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Feb 18 11:26:37 2024 CET
|
||||
Local Time is: Fri Feb 23 15:58:45 2024 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -29,8 +29,8 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
@@ -64,23 +64,23 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--K 198 100 040 - 97
|
||||
3 Spin_Up_Time PO---K 238 100 033 - 1
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1786
|
||||
2 Throughput_Performance P-S--K 198 100 040 - 98
|
||||
3 Spin_Up_Time PO---K 240 100 033 - 1
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1795
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate POSR-K 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--K 131 100 040 - 48
|
||||
9 Power_On_Hours -O--CK 033 033 000 - 29485
|
||||
8 Seek_Time_Performance P-S--K 134 100 040 - 46
|
||||
9 Power_On_Hours -O--CK 033 033 000 - 29572
|
||||
10 Spin_Retry_Count PO--CK 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1753
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1762
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 55834771456
|
||||
188 Command_Timeout -O--CK 100 100 000 - 94502649856
|
||||
190 Airflow_Temperature_Cel -O---K 070 054 045 - 30 (Min/Max 18/31)
|
||||
190 Airflow_Temperature_Cel -O---K 067 054 045 - 33 (Min/Max 18/34)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 64
|
||||
192 Power-Off_Retract_Count -O--CK 099 099 000 - 17432842
|
||||
193 Load_Cycle_Count -O--CK 003 003 000 - 975006
|
||||
192 Power-Off_Retract_Count -O--CK 099 099 000 - 17563916
|
||||
193 Load_Cycle_Count -O--CK 002 002 000 - 986144
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
@@ -147,9 +147,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 18/31 Celsius
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 18/34 Celsius
|
||||
Lifetime Min/Max Temperature: 15/46 Celsius
|
||||
Specified Max Operating Temperature: 31 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -159,7 +159,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (21)
|
||||
Temperature History Size (Index): 128 (76)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
|
Reference in New Issue
Block a user