mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 538)
This commit is contained in:
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Jan 15 08:59:01 2024 CET
|
||||
Local Time is: Mon Oct 14 17:12:01 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,30 +64,30 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 050 - 0
|
||||
3 Spin_Up_Time POS--K 100 100 001 - 3480
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 30
|
||||
3 Spin_Up_Time POS--K 100 100 001 - 3440
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 39
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 050 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 050 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 050 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 381
|
||||
9 Power_On_Hours -O--CK 092 092 000 - 3351
|
||||
10 Spin_Retry_Count PO--CK 100 100 030 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 30
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 39
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 001 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 075 070 045 - 25 (Min/Max 18/25)
|
||||
190 Airflow_Temperature_Cel -O---K 074 067 045 - 26 (Min/Max 24/33)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 14
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 45
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 25 (Min/Max 18/30)
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 61
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 26 (Min/Max 18/33)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 253 000 - 0
|
||||
212 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
220 Disk_Shift -O---- 100 100 000 - 0
|
||||
222 Loaded_Hours -O--CK 100 100 000 - 8
|
||||
222 Loaded_Hours -O--CK 100 100 000 - 15
|
||||
223 Load_Retry_Count -O--CK 100 100 000 - 0
|
||||
224 Load_Friction -O---K 100 100 000 - 0
|
||||
226 Load-in_Time -OS--K 100 100 000 - 650
|
||||
226 Load-in_Time -OS--K 100 100 000 - 645
|
||||
240 Head_Flying_Hours P----- 100 100 001 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -142,9 +142,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 25 Celsius
|
||||
Power Cycle Min/Max Temperature: 18/25 Celsius
|
||||
Lifetime Min/Max Temperature: 18/30 Celsius
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/33 Celsius
|
||||
Lifetime Min/Max Temperature: 18/33 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -152,7 +152,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/55 Celsius
|
||||
Min/Max Temperature Limit: 5/55 Celsius
|
||||
Temperature History Size (Index): 478 (407)
|
||||
Temperature History Size (Index): 478 (93)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 75 (7.5 seconds)
|
||||
@@ -161,18 +161,18 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 30 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 381 --- Power-on Hours
|
||||
0x01 0x008 4 39 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3351 --- Power-on Hours
|
||||
0x01 0x018 6 1305864 --- Logical Sectors Written
|
||||
0x01 0x020 6 3085 --- Number of Write Commands
|
||||
0x01 0x028 6 487618 --- Logical Sectors Read
|
||||
0x01 0x030 6 53682 --- Number of Read Commands
|
||||
0x01 0x028 6 492024 --- Logical Sectors Read
|
||||
0x01 0x030 6 54840 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (rev 1) ==
|
||||
0x02 0x010 4 0 --- Overlimit Shock Events
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 381 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 8 --- Head Flying Hours
|
||||
0x03 0x018 4 45 --- Head Load Events
|
||||
0x03 0x008 4 3351 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 15 --- Head Flying Hours
|
||||
0x03 0x018 4 61 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
@@ -180,21 +180,21 @@ Page Offset Size Value Flags Description
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 25 --- Current Temperature
|
||||
0x05 0x010 1 26 N-- Average Short Term Temperature
|
||||
0x05 0x018 1 - N-- Average Long Term Temperature
|
||||
0x05 0x020 1 30 --- Highest Temperature
|
||||
0x05 0x008 1 26 --- Current Temperature
|
||||
0x05 0x010 1 25 N-- Average Short Term Temperature
|
||||
0x05 0x018 1 27 N-- Average Long Term Temperature
|
||||
0x05 0x020 1 33 --- Highest Temperature
|
||||
0x05 0x028 1 18 --- Lowest Temperature
|
||||
0x05 0x030 1 28 N-- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 26 N-- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - N-- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - N-- Lowest Average Long Term Temperature
|
||||
0x05 0x030 1 30 N-- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 24 N-- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 27 N-- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 25 N-- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 55 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 101 --- Number of Hardware Resets
|
||||
0x06 0x008 4 149 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
|||_ C monitored condition met
|
||||
@@ -214,8 +214,8 @@ ID Size Value Description
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 4 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 4 0 Device-to-host non-data FIS retries
|
||||
0x0009 4 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 4 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
Reference in New Issue