mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 538)
This commit is contained in:
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Fri May 19 10:40:06 2023 AEST
|
||||
Local Time is: Fri May 26 22:40:48 2023 AEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -32,9 +32,8 @@ General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Self-test execution status: ( 24) The self-test routine was aborted by
|
||||
the host.
|
||||
Total time to complete Offline
|
||||
data collection: ( 120) seconds.
|
||||
Offline data collection
|
||||
@@ -65,27 +64,27 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 050 - 0
|
||||
3 Spin_Up_Time POS--K 100 100 001 - 2093
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 3215
|
||||
3 Spin_Up_Time POS--K 100 100 001 - 1652
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 3233
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 050 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 050 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 050 - 0
|
||||
9 Power_On_Hours -O--CK 058 058 000 - 17164
|
||||
9 Power_On_Hours -O--CK 058 058 000 - 17171
|
||||
10 Spin_Retry_Count PO--CK 164 100 030 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 3172
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 3190
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 3201
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 187
|
||||
193 Load_Cycle_Count -O--CK 097 097 000 - 33614
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 40 (Min/Max 12/51)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 193
|
||||
193 Load_Cycle_Count -O--CK 097 097 000 - 33764
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 42 (Min/Max 12/51)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 253 000 - 0
|
||||
220 Disk_Shift -O---- 100 100 000 - 8242
|
||||
222 Loaded_Hours -O--CK 062 062 000 - 15493
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
220 Disk_Shift -O---- 100 100 000 - 8240
|
||||
222 Loaded_Hours -O--CK 062 062 000 - 15494
|
||||
223 Load_Retry_Count -O--CK 100 100 000 - 0
|
||||
224 Load_Friction -O---K 100 100 000 - 0
|
||||
226 Load-in_Time -OS--K 100 100 000 - 334
|
||||
226 Load-in_Time -OS--K 100 100 000 - 335
|
||||
240 Head_Flying_Hours P----- 100 100 001 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -115,7 +114,9 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 3 -
|
||||
# 1 Short offline Aborted by host 80% 17165 -
|
||||
# 2 Short offline Completed without error 00% 17165 -
|
||||
# 3 Short offline Completed without error 00% 3 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -131,8 +132,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 40 Celsius
|
||||
Power Cycle Min/Max Temperature: 18/40 Celsius
|
||||
Current Temperature: 42 Celsius
|
||||
Power Cycle Min/Max Temperature: 41/42 Celsius
|
||||
Lifetime Min/Max Temperature: 12/51 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -141,7 +142,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/55 Celsius
|
||||
Min/Max Temperature Limit: 5/55 Celsius
|
||||
Temperature History Size (Index): 478 (240)
|
||||
Temperature History Size (Index): 478 (172)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -161,8 +162,8 @@ ID Size Value Description
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 4 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 4 0 Device-to-host non-data FIS retries
|
||||
0x0009 4 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 4 18 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 36 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
Reference in New Issue