1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 0, modified: 538)

This commit is contained in:
Andrey Ponomarenko
2025-01-05 03:27:12 +03:00
parent e232681904
commit 43e2303314
538 changed files with 10727 additions and 10442 deletions

View File

@@ -1,4 +1,4 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 14.0-CURRENT amd64] (local build)
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-STABLE amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Fri Aug 27 07:29:28 2021 BST
Local Time is: Sun Sep 12 15:41:21 2021 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,27 +65,27 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 0
2 Throughput_Performance P-S--- 100 100 050 - 0
3 Spin_Up_Time POS--K 100 100 001 - 1361
4 Start_Stop_Count -O--CK 100 100 000 - 3711
3 Spin_Up_Time POS--K 100 100 001 - 1384
4 Start_Stop_Count -O--CK 100 100 000 - 3890
5 Reallocated_Sector_Ct PO--CK 100 100 050 - 0
7 Seek_Error_Rate PO-R-- 100 100 050 - 0
8 Seek_Time_Performance P-S--- 100 100 050 - 0
9 Power_On_Hours -O--CK 085 085 000 - 6164
10 Spin_Retry_Count PO--CK 173 100 030 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 703
191 G-Sense_Error_Rate -O--CK 100 100 000 - 1
192 Power-Off_Retract_Count -O--CK 100 100 000 - 241
193 Load_Cycle_Count -O--CK 090 090 000 - 107755
194 Temperature_Celsius -O---K 100 100 000 - 43 (Min/Max 12/50)
9 Power_On_Hours -O--CK 084 084 000 - 6405
10 Spin_Retry_Count PO--CK 177 100 030 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 719
191 G-Sense_Error_Rate -O--CK 100 100 000 - 46
192 Power-Off_Retract_Count -O--CK 100 100 000 - 248
193 Load_Cycle_Count -O--CK 089 089 000 - 111981
194 Temperature_Celsius -O---K 100 100 000 - 33 (Min/Max 12/50)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
220 Disk_Shift -O---- 100 100 000 - 0
222 Loaded_Hours -O--CK 095 095 000 - 2000
222 Loaded_Hours -O--CK 095 095 000 - 2080
223 Load_Retry_Count -O--CK 100 100 000 - 0
224 Load_Friction -O---K 100 100 000 - 0
226 Load-in_Time -OS--K 100 100 000 - 248
226 Load-in_Time -OS--K 100 100 000 - 258
240 Head_Flying_Hours P----- 100 100 001 - 0
||||||_ K auto-keep
|||||__ C event count
@@ -145,8 +145,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 43 Celsius
Power Cycle Min/Max Temperature: 27/44 Celsius
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 31/41 Celsius
Lifetime Min/Max Temperature: 12/50 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -155,7 +155,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 5/55 Celsius
Min/Max Temperature Limit: 5/55 Celsius
Temperature History Size (Index): 478 (177)
Temperature History Size (Index): 478 (246)
SCT Error Recovery Control:
Read: Disabled
@@ -164,27 +164,27 @@ SCT Error Recovery Control:
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 703 --- Lifetime Power-On Resets
0x01 0x010 4 6164 --- Power-on Hours
0x01 0x018 6 15454449216 --- Logical Sectors Written
0x01 0x020 6 166238365 --- Number of Write Commands
0x01 0x028 6 42338555748 --- Logical Sectors Read
0x01 0x030 6 307862609 --- Number of Read Commands
0x01 0x008 4 719 --- Lifetime Power-On Resets
0x01 0x010 4 6405 --- Power-on Hours
0x01 0x018 6 16156339126 --- Logical Sectors Written
0x01 0x020 6 172700476 --- Number of Write Commands
0x01 0x028 6 44670305769 --- Logical Sectors Read
0x01 0x030 6 322700036 --- Number of Read Commands
0x02 ===== = = === == Free-Fall Statistics (rev 1) ==
0x02 0x010 4 1 --- Overlimit Shock Events
0x02 0x010 4 46 --- Overlimit Shock Events
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 6060 --- Spindle Motor Power-on Hours
0x03 0x010 4 2000 --- Head Flying Hours
0x03 0x018 4 107755 --- Head Load Events
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
0x03 0x008 4 6297 --- Spindle Motor Power-on Hours
0x03 0x010 4 2080 --- Head Flying Hours
0x03 0x018 4 111981 --- Head Load Events
0x03 0x020 4 8 --- Number of Reallocated Logical Sectors
0x03 0x028 4 0 --- Read Recovery Attempts
0x03 0x030 4 0 --- Number of Mechanical Start Failures
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 142 --- Resets Between Cmd Acceptance and Completion
0x04 0x010 4 150 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 43 --- Current Temperature
0x05 0x010 1 37 N-- Average Short Term Temperature
0x05 0x008 1 33 --- Current Temperature
0x05 0x010 1 35 N-- Average Short Term Temperature
0x05 0x018 1 34 N-- Average Long Term Temperature
0x05 0x020 1 50 --- Highest Temperature
0x05 0x028 1 12 --- Lowest Temperature
@@ -197,7 +197,7 @@ Page Offset Size Value Flags Description
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 163 --- Number of Hardware Resets
0x06 0x008 4 171 --- Number of Hardware Resets
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 10 N-- Percentage Used Endurance Indicator
@@ -217,8 +217,8 @@ ID Size Value Description
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 0 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 0 Device-to-host register FISes sent due to a COMRESET
0x0009 4 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
@@ -226,5 +226,3 @@ ID Size Value Description
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC