@@ -13,7 +13,7 @@ Rotation Rate: 10000 rpm
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Apr 11 09:55:14 2024 CEST
|
||||
Local Time is: Thu May 2 21:48:38 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,17 +65,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 197 195 021 - 3133
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2853
|
||||
3 Spin_Up_Time POS--K 199 194 021 - 3041
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2880
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 004 004 000 - 70520
|
||||
9 Power_On_Hours -O--CK 003 003 000 - 71028
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2850
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 283
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2573
|
||||
194 Temperature_Celsius -O---K 109 094 000 - 41
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2877
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 300
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2583
|
||||
194 Temperature_Celsius -O---K 106 094 000 - 44
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -147,8 +147,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 41 Celsius
|
||||
Power Cycle Min/Max Temperature: 40/43 Celsius
|
||||
Current Temperature: 44 Celsius
|
||||
Power Cycle Min/Max Temperature: 41/45 Celsius
|
||||
Lifetime Min/Max Temperature: 16/56 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -160,7 +160,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (83)
|
||||
Temperature History Size (Index): 478 (403)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -180,12 +180,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 13 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 90120 Vendor specific
|
||||
0x8000 4 121858 Vendor specific
|
||||
|
||||
|
||||
|
||||
|