1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 0, modified: 538)

This commit is contained in:
Andrey Ponomarenko
2025-01-05 03:27:12 +03:00
parent e232681904
commit 43e2303314
538 changed files with 10727 additions and 10442 deletions

View File

@@ -1,4 +1,4 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p3 amd64] (local build)
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p5 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -14,7 +14,7 @@ Form Factor: 3.5 inches
Device is: In smartctl database 7.3/5528
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Aug 26 11:14:16 2024 CEST
Local Time is: Sat Nov 9 11:01:48 2024 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,17 +65,17 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
2 Throughput_Performance P-S--- 138 138 054 - 100
3 Spin_Up_Time POS--- 130 130 024 - 484 (Average 525)
4 Start_Stop_Count -O--C- 100 100 000 - 3923
3 Spin_Up_Time POS--- 133 133 024 - 487 (Average 502)
4 Start_Stop_Count -O--C- 100 100 000 - 3989
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
8 Seek_Time_Performance P-S--- 140 140 020 - 15
9 Power_On_Hours -O--C- 095 095 000 - 36380
9 Power_On_Hours -O--C- 095 095 000 - 37581
10 Spin_Retry_Count PO--C- 100 100 060 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 1139
192 Power-Off_Retract_Count -O--CK 092 092 000 - 10127
193 Load_Cycle_Count -O--C- 092 092 000 - 10127
194 Temperature_Celsius -O---- 153 153 000 - 39 (Min/Max 13/60)
12 Power_Cycle_Count -O--CK 100 100 000 - 1205
192 Power-Off_Retract_Count -O--CK 092 092 000 - 10554
193 Load_Cycle_Count -O--C- 092 092 000 - 10554
194 Temperature_Celsius -O---- 166 166 000 - 36 (Min/Max 13/61)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O---K 100 100 000 - 0
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
@@ -117,19 +117,20 @@ No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 33284 -
# 2 Extended offline Completed without error 00% 30414 -
# 3 Short offline Completed without error 00% 30399 -
# 4 Extended offline Aborted by host 90% 30399 -
# 5 Short offline Completed without error 00% 9663 -
# 6 Extended offline Aborted by host 80% 9662 -
# 7 Short offline Completed without error 00% 8180 -
# 8 Extended offline Aborted by host 80% 8161 -
# 9 Short offline Completed without error 00% 274 -
# 1 Short offline Completed without error 00% 36924 -
# 2 Short offline Completed without error 00% 33284 -
# 3 Extended offline Completed without error 00% 30414 -
# 4 Short offline Completed without error 00% 30399 -
# 5 Extended offline Aborted by host 90% 30399 -
# 6 Short offline Completed without error 00% 9663 -
# 7 Extended offline Aborted by host 80% 9662 -
# 8 Short offline Completed without error 00% 8180 -
# 9 Extended offline Aborted by host 80% 8161 -
#10 Short offline Completed without error 00% 274 -
#11 Extended offline Completed without error 00% 212 -
#12 Short offline Completed without error 00% 199 -
#13 Short offline Completed without error 00% 187 -
#11 Short offline Completed without error 00% 274 -
#12 Extended offline Completed without error 00% 212 -
#13 Short offline Completed without error 00% 199 -
#14 Short offline Completed without error 00% 187 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
@@ -145,9 +146,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 39 Celsius
Power Cycle Min/Max Temperature: 24/39 Celsius
Lifetime Min/Max Temperature: 13/60 Celsius
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 21/36 Celsius
Lifetime Min/Max Temperature: 13/61 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
@@ -155,7 +156,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/70 Celsius
Temperature History Size (Index): 128 (66)
Temperature History Size (Index): 128 (68)
SCT Error Recovery Control:
Read: Disabled
@@ -164,39 +165,39 @@ SCT Error Recovery Control:
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 1139 --- Lifetime Power-On Resets
0x01 0x018 6 383308137758 --- Logical Sectors Written
0x01 0x020 6 1398661134 --- Number of Write Commands
0x01 0x028 6 433729630205 --- Logical Sectors Read
0x01 0x030 6 2332449336 --- Number of Read Commands
0x01 0x038 6 130968069250 --- Date and Time TimeStamp
0x01 0x008 4 1205 --- Lifetime Power-On Resets
0x01 0x018 6 385822589158 --- Logical Sectors Written
0x01 0x020 6 1410979243 --- Number of Write Commands
0x01 0x028 6 514238054107 --- Logical Sectors Read
0x01 0x030 6 2383809283 --- Number of Read Commands
0x01 0x038 6 135294812450 --- Date and Time TimeStamp
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 16501 --- Spindle Motor Power-on Hours
0x03 0x010 4 16501 --- Head Flying Hours
0x03 0x018 4 10127 --- Head Load Events
0x03 0x008 4 17067 --- Spindle Motor Power-on Hours
0x03 0x010 4 17067 --- Head Flying Hours
0x03 0x018 4 10554 --- Head Load Events
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
0x03 0x028 4 8 --- Read Recovery Attempts
0x03 0x028 4 9 --- Read Recovery Attempts
0x03 0x030 4 0 --- Number of Mechanical Start Failures
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 278 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 39 --- Current Temperature
0x05 0x010 1 40 N-- Average Short Term Temperature
0x05 0x018 1 44 N-- Average Long Term Temperature
0x05 0x020 1 60 --- Highest Temperature
0x05 0x008 1 36 --- Current Temperature
0x05 0x010 1 38 N-- Average Short Term Temperature
0x05 0x018 1 39 N-- Average Long Term Temperature
0x05 0x020 1 61 --- Highest Temperature
0x05 0x028 1 13 --- Lowest Temperature
0x05 0x030 1 56 N-- Highest Average Short Term Temperature
0x05 0x038 1 18 N-- Lowest Average Short Term Temperature
0x05 0x040 1 55 N-- Highest Average Long Term Temperature
0x05 0x048 1 25 N-- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x050 4 37 --- Time in Over-Temperature
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 4 --- Number of Hardware Resets
0x06 0x010 4 2040 --- Number of ASR Events
0x06 0x008 4 2 --- Number of Hardware Resets
0x06 0x010 4 2180 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
|||_ C monitored condition met
||__ D supports DSN
@@ -214,8 +215,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x0009 2 1 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS