mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 538)
This commit is contained in:
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p3 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Sep 11 07:25:46 2024 PDT
|
||||
Local Time is: Fri Oct 11 14:32:40 2024 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -67,12 +67,12 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct -O--CK 100 100 001 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 12274
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 13002
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 19
|
||||
170 Reserved_Block_Pct PO--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 001 - 0
|
||||
173 Avg_Block-Erase_Count -O--CK 044 044 000 - 1189
|
||||
173 Avg_Block-Erase_Count -O--CK 041 041 000 - 1273
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 15
|
||||
183 SATA_Int_Downshift_Ct -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 000 - 0
|
||||
@@ -84,14 +84,14 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 044 044 001 - 56
|
||||
202 Percent_Lifetime_Remain ----CK 041 041 001 - 59
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 651874428714
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 20371019395
|
||||
248 Bckgnd_Program_Page_Cnt -O--CK 100 100 000 - 13918634770
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 700111877114
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 21878439657
|
||||
248 Bckgnd_Program_Page_Cnt -O--CK 100 100 000 - 14842183594
|
||||
180 Unused_Rsvd_Blk_Cnt_Tot PO--CK 100 100 000 - 2305
|
||||
210 RAIN_Success_Recovered -O--CK 100 100 000 - 0
|
||||
211 Integ_Scan_Complete_Cnt -O--CK 100 100 000 - 83
|
||||
211 Integ_Scan_Complete_Cnt -O--CK 100 100 000 - 87
|
||||
212 Integ_Scan_Folding_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -151,7 +151,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/33 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/34 Celsius
|
||||
Lifetime Min/Max Temperature: 17/52 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -162,7 +162,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (219)
|
||||
Temperature History Size (Index): 478 (146)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -170,12 +170,12 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 3) ==
|
||||
0x01 0x008 4 19 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 12274 --- Power-on Hours
|
||||
0x01 0x018 6 651874428714 --- Logical Sectors Written
|
||||
0x01 0x020 6 5657201918 --- Number of Write Commands
|
||||
0x01 0x028 6 776971997 --- Logical Sectors Read
|
||||
0x01 0x030 6 63116906 --- Number of Read Commands
|
||||
0x01 0x038 6 44189940000 --- Date and Time TimeStamp
|
||||
0x01 0x010 4 13002 --- Power-on Hours
|
||||
0x01 0x018 6 700111877114 --- Logical Sectors Written
|
||||
0x01 0x020 6 6068820014 --- Number of Write Commands
|
||||
0x01 0x028 6 800132775 --- Logical Sectors Read
|
||||
0x01 0x030 6 63552327 --- Number of Read Commands
|
||||
0x01 0x038 6 46807380000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 15 --- Resets Between Cmd Acceptance and Completion
|
||||
@@ -194,11 +194,11 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 287 --- Number of Hardware Resets
|
||||
0x06 0x010 4 90 --- Number of ASR Events
|
||||
0x06 0x008 4 296 --- Number of Hardware Resets
|
||||
0x06 0x010 4 93 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 56 --- Percentage Used Endurance Indicator
|
||||
0x07 0x008 1 59 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
@@ -211,7 +211,7 @@ ID Size Value Description
|
||||
0x0003 4 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 4 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x000a 4 34 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 43 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: Not in smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Feb 4 10:38:38 2024 UTC
|
||||
Local Time is: Thu Sep 5 09:10:27 2024 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
12 Power_Cycle_Count PO--CK 100 100 001 - 2555
|
||||
12 Power_Cycle_Count PO--CK 100 100 001 - 2584
|
||||
175 Program_Fail_Count_Chip PO--CK 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip PO--CK 100 100 000 - 0
|
||||
177 Wear_Leveling_Count PO--CK 066 066 010 - 1024
|
||||
177 Wear_Leveling_Count PO--CK 065 065 010 - 1055
|
||||
178 Used_Rsvd_Blk_Cnt_Chip PO--CK 100 100 000 - 5
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--CK 100 100 000 - 0
|
||||
180 Unused_Rsvd_Blk_Cnt_Tot PO--CK 000 000 000 - 1036
|
||||
181 Program_Fail_Cnt_Total PO--CK 100 100 001 - 0
|
||||
182 Erase_Fail_Count_Total PO--CK 100 100 001 - 0
|
||||
187 Reported_Uncorrect PO--CK 100 100 001 - 0
|
||||
195 Hardware_ECC_Recovered POSR-K 100 100 050 - 94
|
||||
241 Total_LBAs_Written PO--CK 100 100 000 - 41017831742
|
||||
242 Total_LBAs_Read PO--CK 100 100 000 - 55086001099
|
||||
195 Hardware_ECC_Recovered POSR-K 100 100 050 - 231
|
||||
241 Total_LBAs_Written PO--CK 100 100 000 - 47754989750
|
||||
242 Total_LBAs_Read PO--CK 100 100 000 - 56252501214
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -150,8 +150,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 49 Celsius
|
||||
Power Cycle Min/Max Temperature: 44/54 Celsius
|
||||
Current Temperature: 59 Celsius
|
||||
Power Cycle Min/Max Temperature: 58/60 Celsius
|
||||
Lifetime Min/Max Temperature: 16/71 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -160,26 +160,26 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (313)
|
||||
Temperature History Size (Index): 478 (331)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 2555 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 6699 --- Power-on Hours
|
||||
0x01 0x018 6 41017831742 --- Logical Sectors Written
|
||||
0x01 0x020 6 851658194 --- Number of Write Commands
|
||||
0x01 0x028 6 55086001099 --- Logical Sectors Read
|
||||
0x01 0x030 6 1222818051 --- Number of Read Commands
|
||||
0x01 0x008 4 2584 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 11529 --- Power-on Hours
|
||||
0x01 0x018 6 47754989750 --- Logical Sectors Written
|
||||
0x01 0x020 6 916751639 --- Number of Write Commands
|
||||
0x01 0x028 6 56252501214 --- Logical Sectors Read
|
||||
0x01 0x030 6 1248954961 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 1495 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 1560 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 49 --- Current Temperature
|
||||
0x05 0x010 1 48 --- Average Short Term Temperature
|
||||
0x05 0x018 1 47 --- Average Long Term Temperature
|
||||
0x05 0x008 1 59 --- Current Temperature
|
||||
0x05 0x010 1 59 --- Average Short Term Temperature
|
||||
0x05 0x018 1 57 --- Average Long Term Temperature
|
||||
0x05 0x020 1 71 --- Highest Temperature
|
||||
0x05 0x028 1 16 --- Lowest Temperature
|
||||
0x05 0x030 1 67 --- Highest Average Short Term Temperature
|
||||
@@ -205,5 +205,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 16 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 4 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jul 22 10:47:27 2023 -01
|
||||
Local Time is: Sat Jul 22 19:59:41 2023 -01
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -68,12 +68,12 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 9152
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 9161
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 2049
|
||||
170 Grown_Failing_Block_Ct PO--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Wear_Leveling_Count PO--CK 093 093 010 - 230
|
||||
173 Wear_Leveling_Count PO--CK 093 093 010 - 235
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 109
|
||||
181 Non4k_Aligned_Access -O---K 100 100 000 - 4657 1773 2883
|
||||
183 SATA_Iface_Downshift -O--CK 100 100 000 - 0
|
||||
@@ -146,7 +146,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (322)
|
||||
Temperature History Size (Index): 478 (351)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
@@ -156,11 +156,11 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 2049 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 9152 --- Power-on Hours
|
||||
0x01 0x018 6 51518157717 --- Logical Sectors Written
|
||||
0x01 0x020 6 880387778 --- Number of Write Commands
|
||||
0x01 0x028 6 37447396686 --- Logical Sectors Read
|
||||
0x01 0x030 6 725696524 --- Number of Read Commands
|
||||
0x01 0x010 4 9161 --- Power-on Hours
|
||||
0x01 0x018 6 51745716821 --- Logical Sectors Written
|
||||
0x01 0x020 6 882255049 --- Number of Write Commands
|
||||
0x01 0x028 6 37485255628 --- Logical Sectors Read
|
||||
0x01 0x030 6 726140978 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
@@ -193,5 +193,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 22 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 30 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.0-BETA4 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.0-RC4 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: Not in smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Oct 3 14:00:29 2023 CEST
|
||||
Local Time is: Fri Nov 10 15:17:44 2023 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -29,14 +29,14 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 2235) seconds.
|
||||
data collection: ( 570) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
@@ -66,25 +66,25 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 13697
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1215
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 14586
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1250
|
||||
171 Unknown_Attribute -O---K 100 100 000 - 0
|
||||
172 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
173 Unknown_Attribute -O--CK 100 100 000 - 34
|
||||
173 Unknown_Attribute -O--CK 100 100 000 - 37
|
||||
174 Unknown_Attribute -O--CK 100 100 000 - 165
|
||||
175 Program_Fail_Count_Chip -O--CK 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 000 - 4849022534692
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 000 - 4853317567524
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 063 052 000 - 37 (Min/Max 11/48)
|
||||
194 Temperature_Celsius -O---K 067 051 000 - 33 (Min/Max 11/49)
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
201 Unknown_SSD_Attribute ---RC- 100 100 000 - 0
|
||||
241 Total_LBAs_Written -O--CK 100 100 000 - 21666993748
|
||||
242 Total_LBAs_Read -O--CK 100 100 000 - 22276882180
|
||||
243 Unknown_Attribute -O--CK 100 100 000 - 41633705376
|
||||
241 Total_LBAs_Written -O--CK 100 100 000 - 22444649966
|
||||
242 Total_LBAs_Read -O--CK 100 100 000 - 23574891226
|
||||
243 Unknown_Attribute -O--CK 100 100 000 - 44316772448
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -125,12 +125,14 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Offline Completed without error 00% 13697 -
|
||||
# 2 Offline Completed without error 00% 13204 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 10180 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 6826 -
|
||||
# 5 Short offline Completed without error 00% 6775 -
|
||||
# 6 Offline Completed without error 00% 6774 -
|
||||
# 1 Vendor (0xff) Completed without error 00% 14586 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 14066 -
|
||||
# 3 Offline Completed without error 00% 13697 -
|
||||
# 4 Offline Completed without error 00% 13204 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 10180 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 6826 -
|
||||
# 7 Short offline Completed without error 00% 6775 -
|
||||
# 8 Offline Completed without error 00% 6774 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -145,10 +147,10 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/41 Celsius
|
||||
Lifetime Min/Max Temperature: 11/48 Celsius
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/42 Celsius
|
||||
Lifetime Min/Max Temperature: 11/49 Celsius
|
||||
Specified Max Operating Temperature: 55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -157,28 +159,28 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/55 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (357)
|
||||
Temperature History Size (Index): 478 (78)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1215 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 13697 --- Power-on Hours
|
||||
0x01 0x018 6 21666993748 --- Logical Sectors Written
|
||||
0x01 0x020 6 505338546 --- Number of Write Commands
|
||||
0x01 0x028 6 22276882180 --- Logical Sectors Read
|
||||
0x01 0x030 6 547576217 --- Number of Read Commands
|
||||
0x01 0x038 6 49312022580 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 1250 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 14586 --- Power-on Hours
|
||||
0x01 0x018 6 22444649966 --- Logical Sectors Written
|
||||
0x01 0x020 6 533427169 --- Number of Write Commands
|
||||
0x01 0x028 6 23574891226 --- Logical Sectors Read
|
||||
0x01 0x030 6 571773751 --- Number of Read Commands
|
||||
0x01 0x038 6 52511142620 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 37 --- Current Temperature
|
||||
0x05 0x010 1 36 --- Average Short Term Temperature
|
||||
0x05 0x018 1 36 --- Average Long Term Temperature
|
||||
0x05 0x020 1 48 --- Highest Temperature
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x010 1 33 --- Average Short Term Temperature
|
||||
0x05 0x018 1 33 --- Average Long Term Temperature
|
||||
0x05 0x020 1 49 --- Highest Temperature
|
||||
0x05 0x028 1 11 --- Lowest Temperature
|
||||
0x05 0x030 1 43 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 21 --- Lowest Average Short Term Temperature
|
||||
@@ -189,7 +191,7 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 - --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 172 --- Number of Hardware Resets
|
||||
0x06 0x008 4 194 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -203,5 +205,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 16 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 28 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
Reference in New Issue
Block a user