mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 538)
This commit is contained in:
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sun Jun 2 00:24:06 2024 MSK
|
||||
Local Time is: Sun Jun 2 15:04:10 2024 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,7 +65,7 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 3579
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 3593
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 11
|
||||
177 Wear_Leveling_Count PO--C- 099 099 005 - 11
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
@@ -75,21 +75,21 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 063 063 000 - 37
|
||||
194 Temperature_Celsius -O---K 063 060 000 - 37 (Min/Max 15/40)
|
||||
190 Airflow_Temperature_Cel -O--CK 065 063 000 - 35
|
||||
194 Temperature_Celsius -O---K 065 060 000 - 35 (Min/Max 15/40)
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
202 Exception_Mode_Status PO--CK 100 100 010 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 3
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 955935910
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 14804174
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 959965518
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 15636174
|
||||
243 SATA_Downshift_Ct -O--CK 100 100 000 - 0
|
||||
244 Thermal_Throttle_St -O--CK 100 100 000 - 0
|
||||
245 Timed_Workld_Media_Wear -O--CK 100 100 000 - 65535
|
||||
246 Timed_Workld_RdWr_Ratio -O--CK 100 100 000 - 65535
|
||||
247 Timed_Workld_Timer -O--CK 100 100 000 - 65535
|
||||
251 NAND_Writes -O--CK 100 100 000 - 2182131904
|
||||
251 NAND_Writes -O--CK 100 100 000 - 2196008192
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -139,7 +139,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/40 Celsius
|
||||
Lifetime Min/Max Temperature: 15/40 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
@@ -150,7 +150,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (105)
|
||||
Temperature History Size (Index): 128 (65)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -160,17 +160,17 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 11 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3579 --- Power-on Hours
|
||||
0x01 0x018 6 955935910 --- Logical Sectors Written
|
||||
0x01 0x020 6 23842599 --- Number of Write Commands
|
||||
0x01 0x028 6 14804174 --- Logical Sectors Read
|
||||
0x01 0x030 6 709247 --- Number of Read Commands
|
||||
0x01 0x038 6 13000 --- Date and Time TimeStamp
|
||||
0x01 0x010 4 3593 --- Power-on Hours
|
||||
0x01 0x018 6 959965518 --- Logical Sectors Written
|
||||
0x01 0x020 6 23909237 --- Number of Write Commands
|
||||
0x01 0x028 6 15636174 --- Logical Sectors Read
|
||||
0x01 0x030 6 748181 --- Number of Read Commands
|
||||
0x01 0x038 6 2416000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 37 --- Current Temperature
|
||||
0x05 0x008 1 35 --- Current Temperature
|
||||
0x05 0x020 1 40 --- Highest Temperature
|
||||
0x05 0x028 1 15 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sun Jun 2 00:24:06 2024 MSK
|
||||
Local Time is: Sun Jun 2 15:04:10 2024 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,7 +65,7 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 3579
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 3593
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 11
|
||||
177 Wear_Leveling_Count PO--C- 099 099 005 - 11
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
@@ -75,21 +75,21 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 062 062 000 - 38
|
||||
194 Temperature_Celsius -O---K 062 060 000 - 38 (Min/Max 16/40)
|
||||
190 Airflow_Temperature_Cel -O--CK 064 062 000 - 36
|
||||
194 Temperature_Celsius -O---K 064 060 000 - 36 (Min/Max 16/40)
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
202 Exception_Mode_Status PO--CK 100 100 010 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 3
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 914359812
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 374136555
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 918389420
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 374967987
|
||||
243 SATA_Downshift_Ct -O--CK 100 100 000 - 0
|
||||
244 Thermal_Throttle_St -O--CK 100 100 000 - 0
|
||||
245 Timed_Workld_Media_Wear -O--CK 100 100 000 - 65535
|
||||
246 Timed_Workld_RdWr_Ratio -O--CK 100 100 000 - 65535
|
||||
247 Timed_Workld_Timer -O--CK 100 100 000 - 65535
|
||||
251 NAND_Writes -O--CK 100 100 000 - 2062345152
|
||||
251 NAND_Writes -O--CK 100 100 000 - 2075868416
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -139,7 +139,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/40 Celsius
|
||||
Lifetime Min/Max Temperature: 16/40 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
@@ -150,7 +150,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (105)
|
||||
Temperature History Size (Index): 128 (65)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -160,17 +160,17 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 11 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3579 --- Power-on Hours
|
||||
0x01 0x018 6 914359812 --- Logical Sectors Written
|
||||
0x01 0x020 6 23670415 --- Number of Write Commands
|
||||
0x01 0x028 6 374136555 --- Logical Sectors Read
|
||||
0x01 0x030 6 1421360 --- Number of Read Commands
|
||||
0x01 0x038 6 38000 --- Date and Time TimeStamp
|
||||
0x01 0x010 4 3593 --- Power-on Hours
|
||||
0x01 0x018 6 918389420 --- Logical Sectors Written
|
||||
0x01 0x020 6 23735804 --- Number of Write Commands
|
||||
0x01 0x028 6 374967987 --- Logical Sectors Read
|
||||
0x01 0x030 6 1461364 --- Number of Read Commands
|
||||
0x01 0x038 6 2441000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 38 --- Current Temperature
|
||||
0x05 0x008 1 36 --- Current Temperature
|
||||
0x05 0x020 1 40 --- Highest Temperature
|
||||
0x05 0x028 1 16 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [MidnightBSD 3.1.6 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [MidnightBSD 3.2.0 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Aug 9 16:42:01 2024 EDT
|
||||
Local Time is: Mon Nov 11 13:27:36 2024 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -57,9 +57,9 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
|
||||
9 Power_On_Hours 0x0032 086 086 000 Old_age Always - 70460
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 11
|
||||
177 Wear_Leveling_Count 0x0013 084 084 005 Pre-fail Always - 1127
|
||||
9 Power_On_Hours 0x0032 085 085 000 Old_age Always - 72712
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 12
|
||||
177 Wear_Leveling_Count 0x0013 084 084 005 Pre-fail Always - 1131
|
||||
179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0
|
||||
180 Unused_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 9840
|
||||
181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
@@ -67,20 +67,20 @@ ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_
|
||||
183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always - 0
|
||||
184 End-to-End_Error 0x0033 100 100 097 Pre-fail Always - 0
|
||||
187 Uncorrectable_Error_Cnt 0x0032 100 100 000 Old_age Always - 0
|
||||
190 Airflow_Temperature_Cel 0x0032 065 052 000 Old_age Always - 35
|
||||
190 Airflow_Temperature_Cel 0x0032 064 052 000 Old_age Always - 36
|
||||
195 ECC_Error_Rate 0x001a 200 200 000 Old_age Always - 0
|
||||
197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0
|
||||
199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
|
||||
202 Exception_Mode_Status 0x0033 100 100 010 Pre-fail Always - 0
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 11
|
||||
241 Total_LBAs_Written 0x0032 098 098 000 Old_age Always - 3184350394352
|
||||
242 Total_LBAs_Read 0x0032 098 098 000 Old_age Always - 4238864448050
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 12
|
||||
241 Total_LBAs_Written 0x0032 098 098 000 Old_age Always - 3194718295408
|
||||
242 Total_LBAs_Read 0x0032 098 098 000 Old_age Always - 4240166198256
|
||||
243 SATA_Downshift_Ct 0x0032 100 100 000 Old_age Always - 0
|
||||
244 Thermal_Throttle_St 0x0032 100 100 000 Old_age Always - 0
|
||||
245 Timed_Workld_Media_Wear 0x0032 100 100 000 Old_age Always - 65535
|
||||
246 Timed_Workld_RdWr_Ratio 0x0032 100 100 000 Old_age Always - 65535
|
||||
247 Timed_Workld_Timer 0x0032 100 100 000 Old_age Always - 65535
|
||||
251 NAND_Writes 0x0032 100 100 000 Old_age Always - 4821216044272
|
||||
251 NAND_Writes 0x0032 100 100 000 Old_age Always - 4835740206864
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [MidnightBSD 3.1.6 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [MidnightBSD 3.2.0 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Aug 9 16:42:01 2024 EDT
|
||||
Local Time is: Mon Nov 11 13:27:36 2024 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -57,9 +57,9 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
|
||||
9 Power_On_Hours 0x0032 085 085 000 Old_age Always - 71304
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 14
|
||||
177 Wear_Leveling_Count 0x0013 084 084 005 Pre-fail Always - 1141
|
||||
9 Power_On_Hours 0x0032 085 085 000 Old_age Always - 73557
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 15
|
||||
177 Wear_Leveling_Count 0x0013 084 084 005 Pre-fail Always - 1145
|
||||
179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0
|
||||
180 Unused_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 9822
|
||||
181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
@@ -67,20 +67,20 @@ ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_
|
||||
183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always - 0
|
||||
184 End-to-End_Error 0x0033 100 100 097 Pre-fail Always - 0
|
||||
187 Uncorrectable_Error_Cnt 0x0032 100 100 000 Old_age Always - 0
|
||||
190 Airflow_Temperature_Cel 0x0032 065 053 000 Old_age Always - 35
|
||||
190 Airflow_Temperature_Cel 0x0032 064 053 000 Old_age Always - 36
|
||||
195 ECC_Error_Rate 0x001a 200 200 000 Old_age Always - 0
|
||||
197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0
|
||||
199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
|
||||
202 Exception_Mode_Status 0x0033 100 100 010 Pre-fail Always - 0
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 13
|
||||
241 Total_LBAs_Written 0x0032 098 098 000 Old_age Always - 3213794984635
|
||||
242 Total_LBAs_Read 0x0032 098 098 000 Old_age Always - 4206035371043
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 14
|
||||
241 Total_LBAs_Written 0x0032 098 098 000 Old_age Always - 3224162885691
|
||||
242 Total_LBAs_Read 0x0032 098 098 000 Old_age Always - 4207343943173
|
||||
243 SATA_Downshift_Ct 0x0032 100 100 000 Old_age Always - 0
|
||||
244 Thermal_Throttle_St 0x0032 100 100 000 Old_age Always - 0
|
||||
245 Timed_Workld_Media_Wear 0x0032 100 100 000 Old_age Always - 65535
|
||||
246 Timed_Workld_RdWr_Ratio 0x0032 100 100 000 Old_age Always - 65535
|
||||
247 Timed_Workld_Timer 0x0032 100 100 000 Old_age Always - 65535
|
||||
251 NAND_Writes 0x0032 100 100 000 Old_age Always - 4868290908840
|
||||
251 NAND_Writes 0x0032 100 100 000 Old_age Always - 4882816894456
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p5 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Nov 25 01:54:46 2023 EET
|
||||
Local Time is: Tue Jan 30 16:20:37 2024 EET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,14 +66,14 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 002 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 036 036 001 - 42148
|
||||
11 Unknown_SSD_Attribute -O---K 099 099 001 - 70
|
||||
12 Power_Cycle_Count -O--CK 099 099 001 - 167
|
||||
9 Power_On_Hours -O--CK 033 033 001 - 43745
|
||||
11 Unknown_SSD_Attribute -O---K 099 099 001 - 77
|
||||
12 Power_Cycle_Count -O--CK 099 099 001 - 174
|
||||
170 Unused_Rsvd_Blk_Ct_Chip PO--CK 100 100 010 - 364
|
||||
171 Program_Fail_Count_Chip -O---K 100 100 010 - 0
|
||||
172 Erase_Fail_Count_Chip -O--CK 100 100 010 - 0
|
||||
173 Wear_Leveling_Count PO--CK 066 066 005 - 703
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 099 099 001 - 70
|
||||
173 Wear_Leveling_Count PO--CK 065 065 005 - 724
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 099 099 001 - 77
|
||||
183 Runtime_Bad_Block -O--CK 100 100 001 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
@@ -132,8 +132,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SCT command executing in background (5)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/34 Celsius
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/32 Celsius
|
||||
Lifetime Min/Max Temperature: 0/70 Celsius
|
||||
Under/Over Temperature Limit Count: 4294967295/4294901760
|
||||
SMART Status: 0xffff (Reserved)
|
||||
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (70)
|
||||
Temperature History Size (Index): 128 (55)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -152,9 +152,8 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x018 6 77198199900 --- Logical Sectors Written
|
||||
0x01 0x028 6 23506189385 --- Logical Sectors Read
|
||||
0x01 0x1f8 7 - --C+ Unknown
|
||||
0x01 0x018 6 81983084903 --- Logical Sectors Written
|
||||
0x01 0x028 6 24038680207 --- Logical Sectors Read
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 27 --- Current Temperature
|
||||
0x05 0x020 1 40 --- Highest Temperature
|
||||
@@ -175,8 +174,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 17 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 17 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Mar 27 02:27:52 2024 CET
|
||||
Local Time is: Tue Oct 22 00:16:48 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,25 +66,25 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 32420
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 372
|
||||
9 Power_On_Hours -O--CK 092 092 000 - 37396
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 380
|
||||
170 Unused_Rsvd_Blk_Ct_Chip -O--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count_Chip -O--CK 100 100 010 - 0
|
||||
172 Erase_Fail_Count_Chip -O--CK 100 100 010 - 0
|
||||
173 Wear_Leveling_Count PO--CK 096 096 005 - 40
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 099 099 000 - 43
|
||||
173 Wear_Leveling_Count PO--CK 064 064 005 - 448
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 099 099 000 - 47
|
||||
178 Used_Rsvd_Blk_Cnt_Chip PO--C- 100 100 010 - 0
|
||||
180 Unused_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 620
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O--CK 072 040 000 - 28
|
||||
194 Temperature_Celsius -O--CK 073 040 000 - 27
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
233 Media_Wearout_Indicator PO--C- 096 096 000 - 16217974
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 11276
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 19070
|
||||
249 NAND_Writes_1GiB -O--CK 099 099 000 - 28636
|
||||
250 SATA_Iface_Downshift -O--CK 099 099 000 - 23647882491
|
||||
251 NAND_Writes -O--CK 099 099 000 - 60054879424
|
||||
233 Media_Wearout_Indicator PO--C- 063 063 000 - 10513721
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 26000
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 19089
|
||||
249 NAND_Writes_1GiB -O--CK 099 099 000 - 151514
|
||||
250 SATA_Iface_Downshift -O--CK 099 099 000 - 54527688293
|
||||
251 NAND_Writes -O--CK 099 099 000 - 317749909056
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -148,8 +148,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 1 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-3, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jan 30 19:42:15 2024 CET
|
||||
Local Time is: Fri Aug 9 19:08:49 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,24 +65,24 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 999
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 58
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 5600
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 64
|
||||
170 Unused_Rsvd_Blk_Ct_Chip -O--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count_Chip -O--CK 100 100 010 - 0
|
||||
172 Erase_Fail_Count_Chip -O--CK 100 100 010 - 0
|
||||
173 Wear_Leveling_Count PO--CK 099 099 005 - 8
|
||||
173 Wear_Leveling_Count PO--CK 088 088 005 - 141
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 099 099 000 - 10
|
||||
178 Used_Rsvd_Blk_Cnt_Chip PO--C- 100 100 010 - 0
|
||||
180 Unused_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 636
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O--CK 073 060 000 - 27 (Min/Max 18/40)
|
||||
194 Temperature_Celsius -O--CK 070 059 000 - 30 (Min/Max 17/41)
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
233 Media_Wearout_Indicator PO--C- 099 099 001 - 16665366
|
||||
233 Media_Wearout_Indicator PO--C- 088 088 001 - 14805892
|
||||
234 Unknown_Samsung_Attr -O--CK 100 100 000 - 0
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 1712
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 106
|
||||
249 NAND_Writes_1GiB -O--CK 099 099 000 - 2255
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 7672
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 155
|
||||
249 NAND_Writes_1GiB -O--CK 099 099 000 - 35812
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -134,9 +134,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 18/31 Celsius
|
||||
Lifetime Min/Max Temperature: 18/40 Celsius
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/37 Celsius
|
||||
Lifetime Min/Max Temperature: 17/41 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -144,7 +144,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (25)
|
||||
Temperature History Size (Index): 128 (112)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -153,26 +153,26 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 58 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 999 --- Power-on Hours
|
||||
0x01 0x018 6 3592397130 --- Logical Sectors Written
|
||||
0x01 0x008 4 64 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 5600 --- Power-on Hours
|
||||
0x01 0x018 6 16089679610 --- Logical Sectors Written
|
||||
0x01 0x020 6 0 --- Number of Write Commands
|
||||
0x01 0x028 6 222916380 --- Logical Sectors Read
|
||||
0x01 0x028 6 325932508 --- Logical Sectors Read
|
||||
0x01 0x030 6 0 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 27 --- Current Temperature
|
||||
0x05 0x020 1 40 --- Highest Temperature
|
||||
0x05 0x028 1 18 --- Lowest Temperature
|
||||
0x05 0x008 1 30 --- Current Temperature
|
||||
0x05 0x020 1 41 --- Highest Temperature
|
||||
0x05 0x028 1 17 --- Lowest Temperature
|
||||
0x05 0x058 1 55 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 887 --- Number of Hardware Resets
|
||||
0x06 0x008 4 1071 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 N-- Percentage Used Endurance Indicator
|
||||
0x07 0x008 1 11 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
@@ -189,8 +189,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 65 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 65 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -14,7 +14,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed May 17 13:44:33 2023 PDT
|
||||
Local Time is: Wed May 24 11:48:09 2023 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,22 +64,22 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 31773
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 905
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 31834
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 936
|
||||
170 Unused_Rsvd_Blk_Ct_Chip -O--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count_Chip -O--CK 100 100 010 - 0
|
||||
172 Erase_Fail_Count_Chip -O--CK 100 100 010 - 0
|
||||
173 Wear_Leveling_Count PO--CK 088 088 005 - 243
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 099 099 000 - 108
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 099 099 000 - 125
|
||||
178 Used_Rsvd_Blk_Cnt_Chip PO--C- 100 100 010 - 0
|
||||
180 Unused_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 772
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O--CK 066 029 000 - 34
|
||||
199 CRC_Error_Count -OSRCK 098 098 000 - 1167
|
||||
194 Temperature_Celsius -O--CK 070 029 000 - 30
|
||||
199 CRC_Error_Count -OSRCK 098 098 000 - 1188
|
||||
233 Media_Wearout_Indicator PO--C- 087 087 000 - 14738783
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 13445
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 12610
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 13457
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 12617
|
||||
249 NAND_Writes_1GiB -O--CK 099 099 000 - 62256
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -150,8 +150,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SCT command executing in background (5)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/40 Celsius
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/40 Celsius
|
||||
Lifetime Min/Max Temperature: 0/70 Celsius
|
||||
Under/Over Temperature Limit Count: 4294967295/4294901760
|
||||
SMART Status: 0xffff (Reserved)
|
||||
@@ -161,7 +161,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (41)
|
||||
Temperature History Size (Index): 128 (2)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -173,22 +173,20 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 10 Command failed due to ICRC error
|
||||
0x0002 2 10 R_ERR response for data FIS
|
||||
0x0001 2 5 Command failed due to ICRC error
|
||||
0x0002 2 5 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 10 R_ERR response for host-to-device data FIS
|
||||
0x0004 2 5 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 51 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 51 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 10 CRC errors within host-to-device FIS
|
||||
0x0009 2 12 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 5 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 10 R_ERR response for host-to-device data FIS, CRC
|
||||
0x000f 2 5 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
|
||||
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-3, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Dec 15 12:15:01 2023 AEDT
|
||||
Local Time is: Fri Dec 15 14:28:28 2023 AEDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,7 +66,7 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 6484
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 6486
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1160
|
||||
171 Program_Fail_Count_Chip -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count_Chip -O--CK 100 100 000 - 0
|
||||
@@ -78,12 +78,12 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
184 End-to-End_Error PO-RCK 100 100 097 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 036 042 000 - 36 (Min/Max 25/41)
|
||||
194 Temperature_Celsius -O---K 034 042 000 - 34 (Min/Max 25/41)
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
241 Total_LBAs_Written -O--CK 100 100 000 - 423490
|
||||
242 Total_LBAs_Read -O--CK 100 100 000 - 492477
|
||||
243 SATA_Downshift_Ct -O--CK 100 100 000 - 901426
|
||||
241 Total_LBAs_Written -O--CK 100 100 000 - 423535
|
||||
242 Total_LBAs_Read -O--CK 100 100 000 - 492487
|
||||
243 SATA_Downshift_Ct -O--CK 100 100 000 - 901499
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -138,7 +138,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 36 Celsius
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/40 Celsius
|
||||
Lifetime Min/Max Temperature: 15/40 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -148,7 +148,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (14)
|
||||
Temperature History Size (Index): 128 (27)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -158,16 +158,16 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1160 -D- Lifetime Power-On Resets
|
||||
0x01 0x010 4 6484 -D- Power-on Hours
|
||||
0x01 0x018 6 13876941463 -D- Logical Sectors Written
|
||||
0x01 0x020 6 293230806 -D- Number of Write Commands
|
||||
0x01 0x028 6 16137488183 -D- Logical Sectors Read
|
||||
0x01 0x030 6 276121315 -D- Number of Read Commands
|
||||
0x01 0x010 4 6486 -D- Power-on Hours
|
||||
0x01 0x018 6 13878404596 -D- Logical Sectors Written
|
||||
0x01 0x020 6 293253506 -D- Number of Write Commands
|
||||
0x01 0x028 6 16137830335 -D- Logical Sectors Read
|
||||
0x01 0x030 6 276124550 -D- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 -D- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 -D- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 36 -D- Current Temperature
|
||||
0x05 0x008 1 33 -D- Current Temperature
|
||||
0x05 0x020 1 40 -D- Highest Temperature
|
||||
0x05 0x028 1 15 -D- Lowest Temperature
|
||||
0x05 0x058 1 55 -D- Specified Maximum Operating Temperature
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p2 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: Not in smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Aug 5 18:08:51 2024 CEST
|
||||
Local Time is: Thu Aug 8 21:12:20 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,18 +64,18 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 002 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 3612
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 3687
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 90
|
||||
170 Unknown_Attribute PO--C- 100 100 010 - 2288
|
||||
171 Unknown_Attribute -O--CK 100 100 010 - 0
|
||||
172 Unknown_Attribute -O--CK 100 100 010 - 0
|
||||
173 Unknown_Attribute PO--C- 091 091 005 - 293
|
||||
173 Unknown_Attribute PO--C- 091 091 005 - 296
|
||||
174 Unknown_Attribute -O--CK 099 099 000 - 42
|
||||
183 Runtime_Bad_Block -O--CK 099 099 001 - 83
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 066 053 000 - 34
|
||||
190 Airflow_Temperature_Cel -O---K 068 053 000 - 32
|
||||
196 Reallocated_Event_Count -O---- 253 253 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
@@ -134,7 +134,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (106)
|
||||
Temperature History Size (Index): 128 (44)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -154,8 +154,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 20 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 20 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 26 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 26 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -13,7 +13,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: Not in smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu May 2 06:57:58 2024 AEST
|
||||
Local Time is: Thu May 2 13:12:27 2024 AEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,18 +64,18 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 002 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 090 090 000 - 48522
|
||||
9 Power_On_Hours -O--CK 090 090 000 - 48529
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 322
|
||||
170 Unknown_Attribute PO--C- 100 100 010 - 4576
|
||||
171 Unknown_Attribute -O--CK 100 100 010 - 0
|
||||
172 Unknown_Attribute -O--CK 100 100 010 - 0
|
||||
173 Unknown_Attribute PO--C- 078 078 005 - 780
|
||||
174 Unknown_Attribute -O--CK 099 099 000 - 295
|
||||
183 Runtime_Bad_Block -O--CK 099 099 001 - 174
|
||||
183 Runtime_Bad_Block -O--CK 099 099 001 - 179
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 074 059 000 - 26
|
||||
190 Airflow_Temperature_Cel -O---K 073 059 000 - 27
|
||||
196 Reallocated_Event_Count -O---- 253 253 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
@@ -124,7 +124,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SCT command executing in background (5)
|
||||
Current Temperature: 25 Celsius
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/40 Celsius
|
||||
Lifetime Min/Max Temperature: 0/70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -134,7 +134,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (85)
|
||||
Temperature History Size (Index): 128 (123)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -154,8 +154,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 38 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 38 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 58 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 58 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -14,7 +14,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 T13/2015-D revision 2
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jun 13 15:31:11 2023 UTC
|
||||
Local Time is: Sat Jun 24 15:50:24 2023 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -59,19 +59,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 33911
|
||||
12 Power_Cycle_Count -O--CK 074 074 000 - 25401
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 34175
|
||||
12 Power_Cycle_Count -O--CK 074 074 000 - 25402
|
||||
177 Wear_Leveling_Count PO--C- 054 054 000 - 1656
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 064 051 000 - 36
|
||||
190 Airflow_Temperature_Cel -O--CK 068 051 000 - 32
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 253 253 000 - 1095
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 25036
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 224059506195
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 224210192222
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -153,7 +153,7 @@ ID Size Value Description
|
||||
0x0007 2 4096 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 7952 Device-to-host non-data FIS retries
|
||||
0x0009 2 7953 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 10872 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 10896 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 6145 CRC errors within host-to-device FIS
|
||||
0x000d 2 7953 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 8176 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.2-RELEASE-p1 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Samsung based SSDs
|
||||
@@ -11,10 +11,10 @@ User Capacity: 120,034,123,776 bytes [120 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5319
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Aug 3 23:39:57 2023 CEST
|
||||
Local Time is: Sat May 18 13:33:22 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,19 +64,19 @@ SCT capabilities: (0x003d) SCT Status supported.
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 083 083 010 - 351
|
||||
9 Power_On_Hours -O--CK 089 089 000 - 52316
|
||||
12 Power_Cycle_Count -O--CK 064 064 000 - 36348
|
||||
5 Reallocated_Sector_Ct PO--CK 082 082 010 - 394
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 59241
|
||||
12 Power_Cycle_Count -O--CK 063 063 000 - 36379
|
||||
177 Wear_Leveling_Count PO--C- 001 001 000 - 5517
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 083 083 010 - 351
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 082 082 010 - 394
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 083 083 010 - 351
|
||||
183 Runtime_Bad_Block PO--C- 082 082 010 - 394
|
||||
187 Uncorrectable_Error_Cnt -O--CK 099 099 000 - 1
|
||||
190 Airflow_Temperature_Cel -O--CK 063 040 000 - 37
|
||||
190 Airflow_Temperature_Cel -O--CK 064 040 000 - 36
|
||||
195 ECC_Error_Rate -O-RC- 199 199 000 - 1
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 36265
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 36292
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 1960762499432
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -122,17 +122,17 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/ ? Celsius
|
||||
Lifetime Min/Max Temperature: ?/ ? Celsius
|
||||
Under/Over Temperature Limit Count: 0/314495
|
||||
Under/Over Temperature Limit Count: 0/356001
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 128 (7)
|
||||
Temperature History Size (Index): 128 (36)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Jan 3 05:46:29 2024 AEST
|
||||
Local Time is: Wed Apr 17 23:05:56 2024 AEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 087 087 000 - 62933
|
||||
9 Power_On_Hours -O--CK 086 086 000 - 67858
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 151
|
||||
177 Wear_Leveling_Count PO--C- 051 051 000 - 585
|
||||
177 Wear_Leveling_Count PO--C- 051 051 000 - 591
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 055 045 000 - 45
|
||||
190 Airflow_Temperature_Cel -O--CK 057 045 000 - 43
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 099 099 000 - 59
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 117
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 56744263237
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 62273783388
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -124,17 +124,17 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 45 Celsius
|
||||
Current Temperature: 43 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/ ? Celsius
|
||||
Lifetime Min/Max Temperature: ?/ ? Celsius
|
||||
Under/Over Temperature Limit Count: 0/241635
|
||||
Under/Over Temperature Limit Count: 0/256880
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 128 (56)
|
||||
Temperature History Size (Index): 128 (53)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -154,8 +154,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 15 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 15 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [OpenBSD 7.3 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.4 2023-08-01 r5530 [OpenBSD 7.4 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Samsung based SSDs
|
||||
@@ -11,10 +11,10 @@ User Capacity: 250,059,350,016 bytes [250 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5319
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Sep 12 09:34:37 2023 CDT
|
||||
Local Time is: Tue Mar 12 09:38:00 2024 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -59,8 +59,8 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
5 Reallocated_Sector_Ct 0x0033 091 091 010 Pre-fail Always - 356
|
||||
9 Power_On_Hours 0x0032 084 084 000 Old_age Always - 78084
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 694
|
||||
9 Power_On_Hours 0x0032 084 084 000 Old_age Always - 78961
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 853
|
||||
177 Wear_Leveling_Count 0x0013 099 099 000 Pre-fail Always - 2
|
||||
179 Used_Rsvd_Blk_Cnt_Tot 0x0013 091 091 010 Pre-fail Always - 356
|
||||
181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
@@ -70,8 +70,8 @@ ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_
|
||||
190 Airflow_Temperature_Cel 0x0032 071 057 000 Old_age Always - 29
|
||||
195 ECC_Error_Rate 0x001a 199 199 000 Old_age Always - 76
|
||||
199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 284
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 1228153072
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 366
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 1254649904
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
@@ -90,5 +90,7 @@ Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
The above only provides legacy SMART information - try 'smartctl -x' for more
|
||||
|
||||
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p3 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Oct 18 08:20:05 2023 CEST
|
||||
Local Time is: Sat Sep 14 15:51:20 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,19 +66,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 092 092 000 - 39319
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1525
|
||||
177 Wear_Leveling_Count PO--C- 097 097 000 - 36
|
||||
9 Power_On_Hours -O--CK 089 089 000 - 50876
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1528
|
||||
177 Wear_Leveling_Count PO--C- 096 096 000 - 48
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 001 010 Past 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 062 048 000 - 38
|
||||
190 Airflow_Temperature_Cel -O--CK 060 048 000 - 40
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 090 090 000 - 9599
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 211
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 30171517276
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 48166403151
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -128,17 +128,17 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Current Temperature: 40 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/ ? Celsius
|
||||
Lifetime Min/Max Temperature: ?/ ? Celsius
|
||||
Under/Over Temperature Limit Count: 0/164260
|
||||
Under/Over Temperature Limit Count: 0/212133
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 128 (113)
|
||||
Temperature History Size (Index): 128 (5)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -158,8 +158,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 59 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 59 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -14,7 +14,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sun Aug 21 01:00:06 2022 PDT
|
||||
Local Time is: Sun Sep 4 01:00:07 2022 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 58109
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 58445
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1808
|
||||
177 Wear_Leveling_Count PO--C- 093 093 000 - 76
|
||||
177 Wear_Leveling_Count PO--C- 093 093 000 - 78
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 069 052 000 - 31
|
||||
190 Airflow_Temperature_Cel -O--CK 067 052 000 - 33
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 099 099 000 - 1
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 517
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 53392015500
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 53942794844
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -110,25 +110,25 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 535 -
|
||||
# 2 Short offline Completed without error 00% 366 -
|
||||
# 3 Short offline Completed without error 00% 197 -
|
||||
# 4 Extended offline Completed without error 00% 196 -
|
||||
# 5 Short offline Completed without error 00% 15 -
|
||||
# 6 Short offline Completed without error 00% 7959 -
|
||||
# 7 Short offline Completed without error 00% 7790 -
|
||||
# 8 Extended offline Completed without error 00% 7655 -
|
||||
# 9 Short offline Completed without error 00% 7472 -
|
||||
#10 Short offline Completed without error 00% 7303 -
|
||||
#11 Short offline Completed without error 00% 5941 -
|
||||
#12 Extended offline Completed without error 00% 5940 -
|
||||
#13 Short offline Completed without error 00% 5759 -
|
||||
#14 Short offline Completed without error 00% 5590 -
|
||||
#15 Short offline Completed without error 00% 5421 -
|
||||
#16 Extended offline Completed without error 00% 5285 -
|
||||
#17 Short offline Completed without error 00% 5103 -
|
||||
#18 Short offline Completed without error 00% 4934 -
|
||||
#19 Short offline Completed without error 00% 3572 -
|
||||
# 1 Short offline Completed without error 00% 868 -
|
||||
# 2 Extended offline Completed without error 00% 867 -
|
||||
# 3 Short offline Completed without error 00% 535 -
|
||||
# 4 Short offline Completed without error 00% 366 -
|
||||
# 5 Short offline Completed without error 00% 197 -
|
||||
# 6 Extended offline Completed without error 00% 196 -
|
||||
# 7 Short offline Completed without error 00% 15 -
|
||||
# 8 Short offline Completed without error 00% 7959 -
|
||||
# 9 Short offline Completed without error 00% 7790 -
|
||||
#10 Extended offline Completed without error 00% 7655 -
|
||||
#11 Short offline Completed without error 00% 7472 -
|
||||
#12 Short offline Completed without error 00% 7303 -
|
||||
#13 Short offline Completed without error 00% 5941 -
|
||||
#14 Extended offline Completed without error 00% 5940 -
|
||||
#15 Short offline Completed without error 00% 5759 -
|
||||
#16 Short offline Completed without error 00% 5590 -
|
||||
#17 Short offline Completed without error 00% 5421 -
|
||||
#18 Extended offline Completed without error 00% 5285 -
|
||||
#19 Short offline Completed without error 00% 5103 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -144,17 +144,17 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/ ? Celsius
|
||||
Lifetime Min/Max Temperature: ?/ ? Celsius
|
||||
Under/Over Temperature Limit Count: 0/305921
|
||||
Under/Over Temperature Limit Count: 0/307951
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 128 (17)
|
||||
Temperature History Size (Index): 128 (111)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
|
@@ -14,7 +14,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Jul 2 21:04:42 2023 CEST
|
||||
Local Time is: Mon Jul 3 20:36:50 2023 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,19 +64,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 092 092 000 - 39029
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 167
|
||||
9 Power_On_Hours -O--CK 092 092 000 - 39031
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 170
|
||||
177 Wear_Leveling_Count PO--C- 077 077 000 - 831
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 063 055 000 - 37
|
||||
190 Airflow_Temperature_Cel -O--CK 068 055 000 - 32
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 099 099 000 - 1
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 89
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 28897289166
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 90
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 28897428294
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -121,8 +121,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SCT command executing in background (5)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 35/40 Celsius
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/40 Celsius
|
||||
Lifetime Min/Max Temperature: 0/70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -131,7 +131,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (20)
|
||||
Temperature History Size (Index): 128 (3)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -151,8 +151,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 10 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Jan 4 08:00:19 2024 GMT
|
||||
Local Time is: Tue Feb 6 10:49:06 2024 GMT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,9 +64,9 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 092 092 000 - 39828
|
||||
9 Power_On_Hours -O--CK 091 091 000 - 40623
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1834
|
||||
177 Wear_Leveling_Count PO--C- 094 094 000 - 196
|
||||
177 Wear_Leveling_Count PO--C- 088 088 000 - 405
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
@@ -76,7 +76,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 359
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 23125489047
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 30995302221
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -122,8 +122,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SCT command executing in background (5)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/48 Celsius
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/48 Celsius
|
||||
Lifetime Min/Max Temperature: 0/70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -132,7 +132,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (121)
|
||||
Temperature History Size (Index): 128 (26)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -152,8 +152,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 19 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 19 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 31 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 31 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Mar 28 08:52:06 2024 CET
|
||||
Local Time is: Sun Jul 7 17:25:51 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,19 +64,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 6082
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 3572
|
||||
177 Wear_Leveling_Count PO--C- 095 095 000 - 178
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 8513
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 3574
|
||||
177 Wear_Leveling_Count PO--C- 094 094 000 - 185
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 073 041 000 - 27
|
||||
190 Airflow_Temperature_Cel -O--CK 071 041 000 - 29
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 1004
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 39267713931
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 1005
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 42605708301
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -123,8 +123,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SCT command executing in background (5)
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/40 Celsius
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/40 Celsius
|
||||
Lifetime Min/Max Temperature: 0/70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -133,7 +133,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (10)
|
||||
Temperature History Size (Index): 128 (91)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -153,8 +153,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 26 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 26 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p2 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Aug 11 09:24:26 2023 MDT
|
||||
Local Time is: Mon May 6 11:45:50 2024 MDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -22,7 +22,7 @@ APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
@@ -64,19 +64,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 15693
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1020
|
||||
177 Wear_Leveling_Count PO--C- 075 075 000 - 524
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 17295
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1058
|
||||
177 Wear_Leveling_Count PO--C- 072 072 000 - 577
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 072 053 000 - 28
|
||||
190 Airflow_Temperature_Cel -O--CK 071 053 000 - 29
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 160
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 46251975497
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 177
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 48417138676
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -127,8 +127,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SCT command executing in background (5)
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/35 Celsius
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/40 Celsius
|
||||
Lifetime Min/Max Temperature: 0/70 Celsius
|
||||
Under/Over Temperature Limit Count: 4294967295/4294901760
|
||||
SMART Status: 0xffff (Reserved)
|
||||
@@ -138,7 +138,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (39)
|
||||
Temperature History Size (Index): 128 (6)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -158,8 +158,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 24 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 23 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p5 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p6 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Oct 31 06:13:02 2024 EDT
|
||||
Local Time is: Mon Nov 25 20:55:02 2024 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,19 +64,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 086 086 000 - 69198
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 182
|
||||
177 Wear_Leveling_Count PO--C- 064 064 000 - 746
|
||||
9 Power_On_Hours -O--CK 086 086 000 - 69814
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 184
|
||||
177 Wear_Leveling_Count PO--C- 064 064 000 - 761
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 062 051 000 - 38
|
||||
190 Airflow_Temperature_Cel -O--CK 063 051 000 - 37
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 47
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 211026106220
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 212225092444
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -128,7 +128,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SCT command executing in background (5)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 37/40 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/45 Celsius
|
||||
Lifetime Min/Max Temperature: 0/70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -137,7 +137,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (49)
|
||||
Temperature History Size (Index): 128 (3)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -157,8 +157,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Dec 31 15:14:02 2023 CST
|
||||
Local Time is: Wed Aug 7 18:46:48 2024 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,19 +64,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 17300
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 740
|
||||
177 Wear_Leveling_Count PO--C- 076 076 000 - 499
|
||||
9 Power_On_Hours -O--CK 095 095 000 - 22580
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 746
|
||||
177 Wear_Leveling_Count PO--C- 066 066 000 - 716
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 064 045 000 - 36
|
||||
190 Airflow_Temperature_Cel -O--CK 066 045 000 - 34
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 099 099 000 - 2
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 140
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 38253327178
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 146
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 43513599306
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -129,8 +129,8 @@ If Selective self-test is pending on power-up, resume after 1 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SCT command executing in background (5)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/47 Celsius
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/50 Celsius
|
||||
Lifetime Min/Max Temperature: 0/70 Celsius
|
||||
Under/Over Temperature Limit Count: 33554432/0
|
||||
SMART Status: 0x0020 (Reserved)
|
||||
@@ -140,7 +140,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (60)
|
||||
Temperature History Size (Index): 128 (36)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -160,8 +160,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 11 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 11 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Fri Feb 11 12:48:01 2022 PST
|
||||
Local Time is: Sun Mar 20 01:00:01 2022 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 091 091 000 - 40497
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 369
|
||||
9 Power_On_Hours -O--CK 091 091 000 - 41365
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 372
|
||||
177 Wear_Leveling_Count PO--C- 097 097 000 - 49
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 099 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 071 047 000 - 29
|
||||
190 Airflow_Temperature_Cel -O--CK 069 047 000 - 31
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 82
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 106835787783
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 84
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 107079090167
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -111,25 +111,25 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 40416 -
|
||||
# 2 Short offline Completed without error 00% 40394 -
|
||||
# 3 Short offline Completed without error 00% 40225 -
|
||||
# 4 Short offline Completed without error 00% 40056 -
|
||||
# 5 Short offline Completed without error 00% 39887 -
|
||||
# 6 Short offline Completed without error 00% 39718 -
|
||||
# 7 Extended offline Completed without error 00% 39668 -
|
||||
# 8 Short offline Completed without error 00% 39549 -
|
||||
# 9 Short offline Completed without error 00% 39380 -
|
||||
#10 Short offline Completed without error 00% 39211 -
|
||||
#11 Short offline Completed without error 00% 39042 -
|
||||
#12 Extended offline Completed without error 00% 38922 -
|
||||
#13 Short offline Completed without error 00% 38873 -
|
||||
#14 Short offline Completed without error 00% 38705 -
|
||||
#15 Short offline Completed without error 00% 38572 -
|
||||
#16 Extended offline Completed without error 00% 38538 -
|
||||
#17 Short offline Completed without error 00% 38393 -
|
||||
#18 Extended offline Completed without error 00% 38370 -
|
||||
#19 Short offline Completed without error 00% 38224 -
|
||||
# 1 Short offline Completed without error 00% 41230 -
|
||||
# 2 Extended offline Completed without error 00% 41156 -
|
||||
# 3 Short offline Completed without error 00% 41062 -
|
||||
# 4 Short offline Completed without error 00% 40893 -
|
||||
# 5 Short offline Completed without error 00% 40724 -
|
||||
# 6 Short offline Completed without error 00% 40563 -
|
||||
# 7 Extended offline Completed without error 00% 40416 -
|
||||
# 8 Short offline Completed without error 00% 40394 -
|
||||
# 9 Short offline Completed without error 00% 40225 -
|
||||
#10 Short offline Completed without error 00% 40056 -
|
||||
#11 Short offline Completed without error 00% 39887 -
|
||||
#12 Short offline Completed without error 00% 39718 -
|
||||
#13 Extended offline Completed without error 00% 39668 -
|
||||
#14 Short offline Completed without error 00% 39549 -
|
||||
#15 Short offline Completed without error 00% 39380 -
|
||||
#16 Short offline Completed without error 00% 39211 -
|
||||
#17 Short offline Completed without error 00% 39042 -
|
||||
#18 Extended offline Completed without error 00% 38922 -
|
||||
#19 Short offline Completed without error 00% 38873 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -146,8 +146,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/30 Celsius
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/43 Celsius
|
||||
Lifetime Min/Max Temperature: 21/53 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -156,7 +156,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (44)
|
||||
Temperature History Size (Index): 128 (3)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -176,8 +176,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 11 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p7 amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p8 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun May 14 19:22:18 2023 SAST
|
||||
Local Time is: Tue Jul 25 20:35:35 2023 SAST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -23,7 +23,7 @@ APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 16169
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1597
|
||||
177 Wear_Leveling_Count PO--C- 093 093 000 - 131
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 17836
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1615
|
||||
177 Wear_Leveling_Count PO--C- 093 093 000 - 132
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 072 054 000 - 28
|
||||
190 Airflow_Temperature_Cel -O--CK 073 054 000 - 27
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 450
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 43825231659
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 458
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 49202324546
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -127,7 +127,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 28 Celsius
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/31 Celsius
|
||||
Lifetime Min/Max Temperature: 17/46 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -137,7 +137,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (32)
|
||||
Temperature History Size (Index): 128 (66)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -157,8 +157,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 12 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 19 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 19 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Nov 16 23:50:01 2024 MST
|
||||
Local Time is: Wed Nov 27 17:10:19 2024 MST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 099 010 - 0
|
||||
9 Power_On_Hours -O--CK 086 086 000 - 69517
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 381
|
||||
177 Wear_Leveling_Count PO--C- 001 001 000 - 11757
|
||||
9 Power_On_Hours -O--CK 086 086 000 - 69774
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 388
|
||||
177 Wear_Leveling_Count PO--C- 001 001 000 - 11799
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 099 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 099 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 099 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 046 036 000 - 54
|
||||
190 Airflow_Temperature_Cel -O--CK 047 036 000 - 53
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 099 099 000 - 244
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 300
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 658072274964
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 306
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 660954031459
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -147,7 +147,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 54 Celsius
|
||||
Power Cycle Min/Max Temperature: 42/61 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/54 Celsius
|
||||
Lifetime Min/Max Temperature: 15/64 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -156,7 +156,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (52)
|
||||
Temperature History Size (Index): 128 (86)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -176,8 +176,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 87 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 87 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 37 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 37 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 15.0-CURRENT amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Jan 12 10:18:41 2024 CET
|
||||
Local Time is: Sat Jul 13 18:30:50 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,9 +65,9 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 095 095 000 - 21481
|
||||
12 Power_Cycle_Count -O--CK 094 094 000 - 5538
|
||||
177 Wear_Leveling_Count PO--C- 087 087 000 - 267
|
||||
9 Power_On_Hours -O--CK 095 095 000 - 22812
|
||||
12 Power_Cycle_Count -O--CK 094 094 000 - 6047
|
||||
177 Wear_Leveling_Count PO--C- 087 087 000 - 269
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
@@ -76,8 +76,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
190 Airflow_Temperature_Cel -O--CK 066 053 000 - 34
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 1415
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 55335806394
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 1445
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 56066748162
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -127,8 +127,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: ? Celsius
|
||||
Power Cycle Min/Max Temperature: 34/34 Celsius
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/35 Celsius
|
||||
Lifetime Min/Max Temperature: 18/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -137,7 +137,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (122)
|
||||
Temperature History Size (Index): 128 (71)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -157,8 +157,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Nov 16 23:50:01 2024 MST
|
||||
Local Time is: Wed Nov 27 17:10:19 2024 MST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,9 +65,9 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 099 099 010 - 6
|
||||
9 Power_On_Hours -O--CK 086 086 000 - 69431
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 685
|
||||
177 Wear_Leveling_Count PO--C- 001 001 000 - 15164
|
||||
9 Power_On_Hours -O--CK 086 086 000 - 69687
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 692
|
||||
177 Wear_Leveling_Count PO--C- 001 001 000 - 15204
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 099 099 010 - 6
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
@@ -76,8 +76,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
190 Airflow_Temperature_Cel -O--CK 050 034 000 - 50
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 099 099 000 - 10
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 638
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 861899574244
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 644
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 864809966511
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -128,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 50 Celsius
|
||||
Power Cycle Min/Max Temperature: 38/55 Celsius
|
||||
Current Temperature: 51 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/51 Celsius
|
||||
Lifetime Min/Max Temperature: 14/66 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -138,7 +138,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (55)
|
||||
Temperature History Size (Index): 128 (89)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -158,8 +158,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 87 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 87 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 37 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 37 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Nov 16 23:50:01 2024 MST
|
||||
Local Time is: Wed Nov 27 17:10:19 2024 MST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,9 +65,9 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 57963
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 216
|
||||
177 Wear_Leveling_Count PO--C- 001 001 000 - 11037
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 58220
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 223
|
||||
177 Wear_Leveling_Count PO--C- 001 001 000 - 11071
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
@@ -76,8 +76,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
190 Airflow_Temperature_Cel -O--CK 048 037 000 - 52
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 172
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 615263351660
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 178
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 618102452455
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -128,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 52 Celsius
|
||||
Power Cycle Min/Max Temperature: 39/58 Celsius
|
||||
Current Temperature: 53 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/53 Celsius
|
||||
Lifetime Min/Max Temperature: 24/63 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -138,7 +138,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (42)
|
||||
Temperature History Size (Index): 128 (76)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -158,8 +158,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 43 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 43 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 18 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 18 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Nov 16 23:50:01 2024 MST
|
||||
Local Time is: Wed Nov 27 17:10:19 2024 MST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 60145
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 256
|
||||
177 Wear_Leveling_Count PO--C- 001 001 000 - 10690
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 60402
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 263
|
||||
177 Wear_Leveling_Count PO--C- 001 001 000 - 10726
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 046 033 000 - 54
|
||||
190 Airflow_Temperature_Cel -O--CK 047 033 000 - 53
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 099 099 000 - 4
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 183
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 636844583581
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 189
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 639797632676
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -147,7 +147,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 54 Celsius
|
||||
Power Cycle Min/Max Temperature: 41/59 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/54 Celsius
|
||||
Lifetime Min/Max Temperature: 23/68 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -156,7 +156,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (49)
|
||||
Temperature History Size (Index): 128 (83)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -176,8 +176,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 87 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 87 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 37 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 37 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jul 23 21:04:55 2024 CDT
|
||||
Local Time is: Sun Jul 28 18:34:02 2024 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 094 094 000 - 30157
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1518
|
||||
9 Power_On_Hours -O--CK 094 094 000 - 30274
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1525
|
||||
177 Wear_Leveling_Count PO--C- 093 093 000 - 129
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 072 057 000 - 28
|
||||
190 Airflow_Temperature_Cel -O--CK 077 057 000 - 23
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 57
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 119758475041
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 62
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 119835816231
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -128,7 +128,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 24 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/30 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/24 Celsius
|
||||
Lifetime Min/Max Temperature: 21/42 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -137,7 +137,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (125)
|
||||
Temperature History Size (Index): 128 (66)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -157,8 +157,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -14,7 +14,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Jul 12 05:16:05 2024 +04
|
||||
Local Time is: Tue Jul 16 18:43:38 2024 +04
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,19 +64,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 16276
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 16385
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1819
|
||||
177 Wear_Leveling_Count PO--C- 098 098 000 - 31
|
||||
177 Wear_Leveling_Count PO--C- 098 098 000 - 32
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 099 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 070 042 000 - 30
|
||||
190 Airflow_Temperature_Cel -O--CK 066 042 000 - 34
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 099 099 000 - 2
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 52
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 46396339316
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 48382933789
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -128,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 1 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SCT command executing in background (5)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/40 Celsius
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/40 Celsius
|
||||
Lifetime Min/Max Temperature: 0/70 Celsius
|
||||
Under/Over Temperature Limit Count: 4294967295/4294901760
|
||||
SMART Status: 0xffff (Reserved)
|
||||
@@ -139,7 +139,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (30)
|
||||
Temperature History Size (Index): 128 (47)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -159,8 +159,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 42 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 42 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Samsung based SSDs
|
||||
@@ -12,10 +12,10 @@ Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5319
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Aug 11 05:16:41 2023 UTC
|
||||
Local Time is: Mon Apr 1 07:07:44 2024 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 33471
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1493
|
||||
177 Wear_Leveling_Count PO--C- 096 096 000 - 73
|
||||
9 Power_On_Hours -O--CK 092 092 000 - 39085
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1503
|
||||
177 Wear_Leveling_Count PO--C- 089 089 000 - 215
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 058 046 000 - 42
|
||||
190 Airflow_Temperature_Cel -O--CK 057 046 000 - 43
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 32
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 27420590191
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 38
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 43300198895
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -134,8 +134,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 42 Celsius
|
||||
Power Cycle Min/Max Temperature: 38/54 Celsius
|
||||
Current Temperature: 43 Celsius
|
||||
Power Cycle Min/Max Temperature: 41/43 Celsius
|
||||
Lifetime Min/Max Temperature: 19/54 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -144,7 +144,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (2)
|
||||
Temperature History Size (Index): 128 (29)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p4 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jul 16 19:59:01 2024 CEST
|
||||
Local Time is: Tue Sep 24 10:30:22 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,19 +64,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 11937
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1405
|
||||
177 Wear_Leveling_Count PO--C- 045 045 000 - 1158
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 13430
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1408
|
||||
177 Wear_Leveling_Count PO--C- 039 039 000 - 1288
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 099 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 049 034 000 - 51
|
||||
190 Airflow_Temperature_Cel -O--CK 043 033 000 - 57
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 37
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 20097698710
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 39
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 21893490598
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -131,8 +131,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SCT command executing in background (5)
|
||||
Current Temperature: 51 Celsius
|
||||
Power Cycle Min/Max Temperature: 40/62 Celsius
|
||||
Current Temperature: 54 Celsius
|
||||
Power Cycle Min/Max Temperature: 40/67 Celsius
|
||||
Lifetime Min/Max Temperature: 0/70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (64)
|
||||
Temperature History Size (Index): 128 (62)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -161,8 +161,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 17 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 17 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Jul 12 01:06:46 2023 CEST
|
||||
Local Time is: Mon Jul 31 22:05:18 2023 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 16533
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 244
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 17007
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 258
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 7
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 044 040 000 - 56
|
||||
190 Airflow_Temperature_Cel -O--CK 042 035 000 - 58
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 211
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 7905125884
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 225
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 8563228322
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -127,9 +127,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 55 Celsius
|
||||
Power Cycle Min/Max Temperature: 46/59 Celsius
|
||||
Lifetime Min/Max Temperature: 14/60 Celsius
|
||||
Current Temperature: 58 Celsius
|
||||
Power Cycle Min/Max Temperature: 47/60 Celsius
|
||||
Lifetime Min/Max Temperature: 14/65 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -137,7 +137,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (120)
|
||||
Temperature History Size (Index): 128 (33)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -157,8 +157,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jan 13 18:22:42 2024 EST
|
||||
Local Time is: Sat Apr 13 12:24:39 2024 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 090 090 000 - 48346
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 34
|
||||
177 Wear_Leveling_Count PO--C- 094 094 000 - 310
|
||||
9 Power_On_Hours -O--CK 089 089 000 - 50523
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 40
|
||||
177 Wear_Leveling_Count PO--C- 094 094 000 - 329
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 069 065 000 - 31
|
||||
190 Airflow_Temperature_Cel -O--CK 072 065 000 - 28
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 16
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 51667229625
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 20
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 52458296721
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -127,17 +127,17 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/ ? Celsius
|
||||
Lifetime Min/Max Temperature: ?/ ? Celsius
|
||||
Under/Over Temperature Limit Count: 0/190021
|
||||
Under/Over Temperature Limit Count: 0/203085
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 128 (118)
|
||||
Temperature History Size (Index): 128 (127)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -157,8 +157,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 74 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 74 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 33 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 33 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -14,7 +14,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Feb 28 15:48:06 2024 KST
|
||||
Local Time is: Fri Mar 22 09:27:58 2024 KST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 6627
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 7173
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 534
|
||||
177 Wear_Leveling_Count PO--C- 096 096 000 - 222
|
||||
177 Wear_Leveling_Count PO--C- 095 095 000 - 264
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 067 054 000 - 33
|
||||
190 Airflow_Temperature_Cel -O--CK 074 054 000 - 26
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 16
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 83613123219
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 102176645340
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -128,17 +128,17 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/ ? Celsius
|
||||
Lifetime Min/Max Temperature: ?/ ? Celsius
|
||||
Under/Over Temperature Limit Count: 0/39550
|
||||
Under/Over Temperature Limit Count: 0/42832
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 128 (75)
|
||||
Temperature History Size (Index): 128 (21)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -158,8 +158,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 32 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 32 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 41 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 41 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p2 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Aug 27 21:07:53 2023 CEST
|
||||
Local Time is: Mon Oct 21 11:45:23 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 3717
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 737
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 22
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 13803
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 748
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 54
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 061 049 000 - 39
|
||||
190 Airflow_Temperature_Cel -O--CK 052 041 000 - 48
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 35
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 6605298433
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 43
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 16373341658
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -128,9 +128,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/45 Celsius
|
||||
Lifetime Min/Max Temperature: 20/46 Celsius
|
||||
Current Temperature: 47 Celsius
|
||||
Power Cycle Min/Max Temperature: 37/59 Celsius
|
||||
Lifetime Min/Max Temperature: 20/59 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -138,7 +138,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (74)
|
||||
Temperature History Size (Index): 128 (55)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -151,18 +151,18 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0002 2 1 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0004 2 1 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 26 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 26 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x0009 2 27 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 27 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 1 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x000f 2 1 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
|
@@ -14,7 +14,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Nov 28 16:55:56 2024 WET
|
||||
Local Time is: Fri Dec 13 15:49:22 2024 WET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 16423
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 16782
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 3578
|
||||
177 Wear_Leveling_Count PO--C- 096 001 000 - 203
|
||||
177 Wear_Leveling_Count PO--C- 096 001 000 - 205
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 074 047 000 - 26
|
||||
190 Airflow_Temperature_Cel -O--CK 077 047 000 - 23
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 70
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 81517483490
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 82085388466
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -129,17 +129,17 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 26 Celsius
|
||||
Current Temperature: 23 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/ ? Celsius
|
||||
Lifetime Min/Max Temperature: ?/ ? Celsius
|
||||
Under/Over Temperature Limit Count: 0/97053
|
||||
Under/Over Temperature Limit Count: 0/99215
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 128 (64)
|
||||
Temperature History Size (Index): 128 (42)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -159,8 +159,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jun 4 20:34:44 2024 CEST
|
||||
Local Time is: Sat Jun 15 20:59:40 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -23,7 +23,7 @@ APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
@@ -65,8 +65,8 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 1858
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 657
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 2048
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 729
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 6
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
@@ -76,8 +76,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
190 Airflow_Temperature_Cel -O--CK 075 052 000 - 25
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 641
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 7106750563
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 667
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 7301509027
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -128,7 +128,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 25 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/40 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/40 Celsius
|
||||
Lifetime Min/Max Temperature: 23/45 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -139,7 +139,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (33)
|
||||
Temperature History Size (Index): 128 (83)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -148,13 +148,13 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 657 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1858 --- Power-on Hours
|
||||
0x01 0x018 6 7106750563 --- Logical Sectors Written
|
||||
0x01 0x020 6 118580682 --- Number of Write Commands
|
||||
0x01 0x028 6 5425755069 --- Logical Sectors Read
|
||||
0x01 0x030 6 35547455 --- Number of Read Commands
|
||||
0x01 0x038 6 1288000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 729 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2048 --- Power-on Hours
|
||||
0x01 0x018 6 7301509027 --- Logical Sectors Written
|
||||
0x01 0x020 6 128109823 --- Number of Write Commands
|
||||
0x01 0x028 6 5724650343 --- Logical Sectors Read
|
||||
0x01 0x030 6 37156501 --- Number of Read Commands
|
||||
0x01 0x038 6 15000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
@@ -164,7 +164,7 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x028 1 23 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 332 --- Number of Hardware Resets
|
||||
0x06 0x008 4 439 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -185,8 +185,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
@@ -194,5 +194,3 @@ ID Size Value Description
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
|
||||
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jun 4 20:34:44 2024 CEST
|
||||
Local Time is: Sat Jun 15 20:59:40 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -23,7 +23,7 @@ APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
@@ -65,8 +65,8 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 8082
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1249
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 8271
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1321
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 10
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
@@ -76,8 +76,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
190 Airflow_Temperature_Cel -O--CK 075 049 000 - 25
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 93
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 17465348424
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 120
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 17663483527
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -129,7 +129,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 25 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/40 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/40 Celsius
|
||||
Lifetime Min/Max Temperature: 20/51 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -140,7 +140,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (97)
|
||||
Temperature History Size (Index): 128 (19)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -149,13 +149,13 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1249 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 8082 --- Power-on Hours
|
||||
0x01 0x018 6 17465348424 --- Logical Sectors Written
|
||||
0x01 0x020 6 194568690 --- Number of Write Commands
|
||||
0x01 0x028 6 11318890235 --- Logical Sectors Read
|
||||
0x01 0x030 6 148463819 --- Number of Read Commands
|
||||
0x01 0x038 6 347000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 1321 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 8271 --- Power-on Hours
|
||||
0x01 0x018 6 17663483527 --- Logical Sectors Written
|
||||
0x01 0x020 6 204037155 --- Number of Write Commands
|
||||
0x01 0x028 6 11619144245 --- Logical Sectors Read
|
||||
0x01 0x030 6 150032077 --- Number of Read Commands
|
||||
0x01 0x038 6 2645000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 682 --- Resets Between Cmd Acceptance and Completion
|
||||
@@ -165,7 +165,7 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 5784 --- Number of Hardware Resets
|
||||
0x06 0x008 4 5893 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -186,8 +186,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [OpenBSD 7.5 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [OpenBSD 7.6 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 4 01:25:59 2024 EDT
|
||||
Local Time is: Fri Oct 18 14:35:06 2024 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -60,19 +60,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
|
||||
9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 46
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 90
|
||||
177 Wear_Leveling_Count 0x0013 099 099 000 Pre-fail Always - 2
|
||||
9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 61
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 127
|
||||
177 Wear_Leveling_Count 0x0013 099 099 000 Pre-fail Always - 3
|
||||
179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0
|
||||
181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
182 Erase_Fail_Count_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always - 0
|
||||
187 Uncorrectable_Error_Cnt 0x0032 100 100 000 Old_age Always - 0
|
||||
190 Airflow_Temperature_Cel 0x0032 060 053 000 Old_age Always - 40
|
||||
190 Airflow_Temperature_Cel 0x0032 058 053 000 Old_age Always - 42
|
||||
195 ECC_Error_Rate 0x001a 200 200 000 Old_age Always - 0
|
||||
199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 4
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 2385935302
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 9
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 3102945101
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p2 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Sep 3 19:08:48 2023 EDT
|
||||
Local Time is: Sun Mar 24 08:04:18 2024 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 9169
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 165
|
||||
177 Wear_Leveling_Count PO--C- 072 072 000 - 509
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 14026
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 183
|
||||
177 Wear_Leveling_Count PO--C- 043 043 000 - 1020
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 059 037 000 - 41
|
||||
190 Airflow_Temperature_Cel -O--CK 056 037 000 - 44
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 58
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 64084913474
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 61
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 98463345090
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -127,8 +127,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 41 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/46 Celsius
|
||||
Current Temperature: 44 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/41 Celsius
|
||||
Lifetime Min/Max Temperature: 20/63 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -139,7 +139,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (103)
|
||||
Temperature History Size (Index): 128 (73)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -148,27 +148,27 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 165 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 9169 --- Power-on Hours
|
||||
0x01 0x018 6 64084914138 --- Logical Sectors Written
|
||||
0x01 0x020 6 924688812 --- Number of Write Commands
|
||||
0x01 0x028 6 4735494713 --- Logical Sectors Read
|
||||
0x01 0x030 6 235939104 --- Number of Read Commands
|
||||
0x01 0x038 6 99000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 183 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 14026 --- Power-on Hours
|
||||
0x01 0x018 6 98463345090 --- Logical Sectors Written
|
||||
0x01 0x020 6 1319807272 --- Number of Write Commands
|
||||
0x01 0x028 6 4808741922 --- Logical Sectors Read
|
||||
0x01 0x030 6 238426098 --- Number of Read Commands
|
||||
0x01 0x038 6 1475000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 101 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 41 --- Current Temperature
|
||||
0x05 0x008 1 44 --- Current Temperature
|
||||
0x05 0x020 1 63 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 1608 --- Number of Hardware Resets
|
||||
0x06 0x008 4 1814 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 29 N-- Percentage Used Endurance Indicator
|
||||
0x07 0x008 1 59 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
@@ -185,8 +185,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 17 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 17 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 29 18:23:02 2023 CEST
|
||||
Local Time is: Mon Jun 5 16:25:05 2023 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,19 +66,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 3450
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1746
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 3615
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1755
|
||||
177 Wear_Leveling_Count PO--C- 096 096 000 - 55
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 062 045 000 - 38
|
||||
190 Airflow_Temperature_Cel -O--CK 059 045 000 - 41
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 236
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 18343203755
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 241
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 18602357501
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -136,23 +136,23 @@ SCT (Get) Error Recovery Control command failed
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1746 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3450 --- Power-on Hours
|
||||
0x01 0x018 6 18343203755 --- Logical Sectors Written
|
||||
0x01 0x020 6 239238467 --- Number of Write Commands
|
||||
0x01 0x028 6 16948838967 --- Logical Sectors Read
|
||||
0x01 0x030 6 233785340 --- Number of Read Commands
|
||||
0x01 0x038 6 1012000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 1755 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3615 --- Power-on Hours
|
||||
0x01 0x018 6 18602357501 --- Logical Sectors Written
|
||||
0x01 0x020 6 242366683 --- Number of Write Commands
|
||||
0x01 0x028 6 16997910562 --- Logical Sectors Read
|
||||
0x01 0x030 6 234620680 --- Number of Read Commands
|
||||
0x01 0x038 6 2892000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 38 --- Current Temperature
|
||||
0x05 0x008 1 41 --- Current Temperature
|
||||
0x05 0x020 1 55 --- Highest Temperature
|
||||
0x05 0x028 1 18 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 6541 --- Number of Hardware Resets
|
||||
0x06 0x008 4 6597 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -173,8 +173,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p2 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Sep 3 19:08:48 2023 EDT
|
||||
Local Time is: Sun Mar 24 08:04:18 2024 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 9169
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 165
|
||||
177 Wear_Leveling_Count PO--C- 071 071 000 - 511
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 14026
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 183
|
||||
177 Wear_Leveling_Count PO--C- 043 043 000 - 1025
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 058 042 000 - 42
|
||||
190 Airflow_Temperature_Cel -O--CK 055 042 000 - 45
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 099 099 000 - 42
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 56
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 64085280477
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 59
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 98463715045
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -127,8 +127,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 42 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/47 Celsius
|
||||
Current Temperature: 45 Celsius
|
||||
Power Cycle Min/Max Temperature: 34/43 Celsius
|
||||
Lifetime Min/Max Temperature: 21/58 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -139,7 +139,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (103)
|
||||
Temperature History Size (Index): 128 (73)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -148,27 +148,27 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 165 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 9169 --- Power-on Hours
|
||||
0x01 0x018 6 64085280989 --- Logical Sectors Written
|
||||
0x01 0x020 6 922588439 --- Number of Write Commands
|
||||
0x01 0x028 6 4756557539 --- Logical Sectors Read
|
||||
0x01 0x030 6 235362124 --- Number of Read Commands
|
||||
0x01 0x038 6 50000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 183 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 14026 --- Power-on Hours
|
||||
0x01 0x018 6 98463715045 --- Logical Sectors Written
|
||||
0x01 0x020 6 1316607943 --- Number of Write Commands
|
||||
0x01 0x028 6 4823858717 --- Logical Sectors Read
|
||||
0x01 0x030 6 237574808 --- Number of Read Commands
|
||||
0x01 0x038 6 1402000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 139 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 42 --- Current Temperature
|
||||
0x05 0x008 1 45 --- Current Temperature
|
||||
0x05 0x020 1 58 --- Highest Temperature
|
||||
0x05 0x028 1 21 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 1650 --- Number of Hardware Resets
|
||||
0x06 0x008 4 1856 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 42 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 29 N-- Percentage Used Endurance Indicator
|
||||
0x07 0x008 1 59 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
@@ -185,8 +185,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 17 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 17 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Nov 13 04:50:09 2022 PST
|
||||
Local Time is: Tue Dec 13 04:50:09 2022 PST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,7 +65,7 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 32885
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 33605
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 786
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 3
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
@@ -73,7 +73,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 071 050 000 - 29
|
||||
190 Airflow_Temperature_Cel -O--CK 069 050 000 - 31
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 423
|
||||
@@ -127,8 +127,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/40 Celsius
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/40 Celsius
|
||||
Lifetime Min/Max Temperature: 13/50 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -139,7 +139,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (92)
|
||||
Temperature History Size (Index): 128 (59)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -149,22 +149,22 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 786 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 32885 --- Power-on Hours
|
||||
0x01 0x010 4 33605 --- Power-on Hours
|
||||
0x01 0x018 6 2312753759 --- Logical Sectors Written
|
||||
0x01 0x020 6 11601365 --- Number of Write Commands
|
||||
0x01 0x028 6 1870990163 --- Logical Sectors Read
|
||||
0x01 0x030 6 13186542 --- Number of Read Commands
|
||||
0x01 0x038 6 613000 --- Date and Time TimeStamp
|
||||
0x01 0x028 6 1871003003 --- Logical Sectors Read
|
||||
0x01 0x030 6 13187018 --- Number of Read Commands
|
||||
0x01 0x038 6 569000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 699 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 700 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 29 --- Current Temperature
|
||||
0x05 0x008 1 31 --- Current Temperature
|
||||
0x05 0x020 1 50 --- Highest Temperature
|
||||
0x05 0x028 1 13 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 11608 --- Number of Hardware Resets
|
||||
0x06 0x008 4 11624 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -185,8 +185,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 55 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 55 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 71 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 71 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jan 6 01:00:04 2024 EST
|
||||
Local Time is: Fri Jan 26 13:46:34 2024 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -58,19 +58,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
|
||||
9 Power_On_Hours 0x0032 089 089 000 Old_age Always - 51006
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 102
|
||||
9 Power_On_Hours 0x0032 089 089 000 Old_age Always - 51498
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 106
|
||||
177 Wear_Leveling_Count 0x0013 097 097 000 Pre-fail Always - 39
|
||||
179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0
|
||||
181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
182 Erase_Fail_Count_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always - 0
|
||||
187 Uncorrectable_Error_Cnt 0x0032 100 100 000 Old_age Always - 0
|
||||
190 Airflow_Temperature_Cel 0x0032 076 056 000 Old_age Always - 24
|
||||
190 Airflow_Temperature_Cel 0x0032 077 056 000 Old_age Always - 23
|
||||
195 ECC_Error_Rate 0x001a 200 200 000 Old_age Always - 0
|
||||
199 CRC_Error_Count 0x003e 099 099 000 Old_age Always - 52
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 55
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 64024008991
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 59
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 64024009727
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Jun 6 14:32:58 2024 EDT
|
||||
Local Time is: Tue Jul 2 06:50:30 2024 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 5304
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 537
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 5920
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 540
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 13
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 070 056 000 - 30
|
||||
190 Airflow_Temperature_Cel -O--CK 074 056 000 - 26
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 347
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 9053234833
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 9186329129
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -146,8 +146,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/40 Celsius
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/40 Celsius
|
||||
Lifetime Min/Max Temperature: 20/42 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -158,7 +158,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (41)
|
||||
Temperature History Size (Index): 128 (26)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -167,23 +167,23 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 537 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 5304 --- Power-on Hours
|
||||
0x01 0x018 6 9053234833 --- Logical Sectors Written
|
||||
0x01 0x020 6 185041324 --- Number of Write Commands
|
||||
0x01 0x028 6 4149624211 --- Logical Sectors Read
|
||||
0x01 0x030 6 59004800 --- Number of Read Commands
|
||||
0x01 0x038 6 1329000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 540 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 5920 --- Power-on Hours
|
||||
0x01 0x018 6 9186329129 --- Logical Sectors Written
|
||||
0x01 0x020 6 187233090 --- Number of Write Commands
|
||||
0x01 0x028 6 4155930311 --- Logical Sectors Read
|
||||
0x01 0x030 6 59281568 --- Number of Read Commands
|
||||
0x01 0x038 6 543000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 116 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 30 --- Current Temperature
|
||||
0x05 0x008 1 26 --- Current Temperature
|
||||
0x05 0x020 1 42 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 2470 --- Number of Hardware Resets
|
||||
0x06 0x008 4 2488 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -204,8 +204,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 37 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 37 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Nov 19 21:18:53 2023 GMT
|
||||
Local Time is: Wed Nov 29 12:23:49 2023 GMT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 4311
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 213
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 11
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 4512
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 223
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 12
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 061 051 000 - 39
|
||||
190 Airflow_Temperature_Cel -O--CK 062 051 000 - 38
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 25
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 17694205062
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 26
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 18609371484
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -128,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/41 Celsius
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/43 Celsius
|
||||
Lifetime Min/Max Temperature: 25/49 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -140,7 +140,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (64)
|
||||
Temperature History Size (Index): 128 (125)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -149,23 +149,23 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 213 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 4311 --- Power-on Hours
|
||||
0x01 0x018 6 17694205062 --- Logical Sectors Written
|
||||
0x01 0x020 6 189687396 --- Number of Write Commands
|
||||
0x01 0x028 6 11455527097 --- Logical Sectors Read
|
||||
0x01 0x030 6 169194362 --- Number of Read Commands
|
||||
0x01 0x038 6 1493000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 223 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 4512 --- Power-on Hours
|
||||
0x01 0x018 6 18609371484 --- Logical Sectors Written
|
||||
0x01 0x020 6 199127811 --- Number of Write Commands
|
||||
0x01 0x028 6 11785436163 --- Logical Sectors Read
|
||||
0x01 0x030 6 175212471 --- Number of Read Commands
|
||||
0x01 0x038 6 807000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 39 --- Current Temperature
|
||||
0x05 0x008 1 38 --- Current Temperature
|
||||
0x05 0x020 1 49 --- Highest Temperature
|
||||
0x05 0x028 1 25 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 20042 --- Number of Hardware Resets
|
||||
0x06 0x008 4 20645 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -186,8 +186,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 549 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 107 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 107 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Aug 27 23:47:46 2023 GMT
|
||||
Local Time is: Sun Aug 27 23:53:52 2023 GMT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -73,7 +73,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 063 040 000 - 37
|
||||
190 Airflow_Temperature_Cel -O--CK 062 040 000 - 38
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 1457
|
||||
@@ -131,7 +131,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/40 Celsius
|
||||
Lifetime Min/Max Temperature: 27/60 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (95)
|
||||
Temperature History Size (Index): 128 (96)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -158,12 +158,12 @@ Page Offset Size Value Flags Description
|
||||
0x01 0x020 6 684183523 --- Number of Write Commands
|
||||
0x01 0x028 6 37367177705 --- Logical Sectors Read
|
||||
0x01 0x030 6 535539073 --- Number of Read Commands
|
||||
0x01 0x038 6 1358000 --- Date and Time TimeStamp
|
||||
0x01 0x038 6 1724000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 10309 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 37 --- Current Temperature
|
||||
0x05 0x008 1 38 --- Current Temperature
|
||||
0x05 0x020 1 60 --- Highest Temperature
|
||||
0x05 0x028 1 27 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Apr 23 18:20:27 2021 BST
|
||||
Local Time is: Fri Aug 20 17:48:59 2021 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 476
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 301
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 5
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 519
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 335
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 6
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 068 050 000 - 32
|
||||
190 Airflow_Temperature_Cel -O--CK 062 050 000 - 38
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 23
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 5812590042
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 25
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 6415289980
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -128,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/40 Celsius
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/40 Celsius
|
||||
Lifetime Min/Max Temperature: 19/50 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -140,7 +140,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (123)
|
||||
Temperature History Size (Index): 128 (17)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -149,23 +149,23 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 301 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 476 --- Power-on Hours
|
||||
0x01 0x018 6 5812590042 --- Logical Sectors Written
|
||||
0x01 0x020 6 61371199 --- Number of Write Commands
|
||||
0x01 0x028 6 2612943209 --- Logical Sectors Read
|
||||
0x01 0x030 6 31723624 --- Number of Read Commands
|
||||
0x01 0x038 6 1210000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 335 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 519 --- Power-on Hours
|
||||
0x01 0x018 6 6415289980 --- Logical Sectors Written
|
||||
0x01 0x020 6 70334782 --- Number of Write Commands
|
||||
0x01 0x028 6 2849481108 --- Logical Sectors Read
|
||||
0x01 0x030 6 34906194 --- Number of Read Commands
|
||||
0x01 0x038 6 1837000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 32 --- Current Temperature
|
||||
0x05 0x008 1 38 --- Current Temperature
|
||||
0x05 0x020 1 50 --- Highest Temperature
|
||||
0x05 0x028 1 19 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 1588 --- Number of Hardware Resets
|
||||
0x06 0x008 4 1718 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -186,8 +186,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p2 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Aug 17 20:26:26 2023 PDT
|
||||
Local Time is: Sun Dec 24 21:05:58 2023 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 095 095 000 - 22973
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 86
|
||||
177 Wear_Leveling_Count PO--C- 093 093 000 - 125
|
||||
9 Power_On_Hours -O--CK 094 094 000 - 26062
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 90
|
||||
177 Wear_Leveling_Count PO--C- 091 091 000 - 146
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 046 032 000 - 54
|
||||
190 Airflow_Temperature_Cel -O--CK 048 032 000 - 52
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 75
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 39042729875
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 78
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 51500994044
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -130,8 +130,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 54 Celsius
|
||||
Power Cycle Min/Max Temperature: 40/68 Celsius
|
||||
Current Temperature: 52 Celsius
|
||||
Power Cycle Min/Max Temperature: 40/63 Celsius
|
||||
Lifetime Min/Max Temperature: 28/68 Celsius
|
||||
Specified Max Operating Temperature: 55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (33)
|
||||
Temperature History Size (Index): 128 (7)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -151,27 +151,27 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 86 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 22973 --- Power-on Hours
|
||||
0x01 0x018 6 39042729875 --- Logical Sectors Written
|
||||
0x01 0x020 6 1294816840 --- Number of Write Commands
|
||||
0x01 0x028 6 124319567 --- Logical Sectors Read
|
||||
0x01 0x030 6 4374125 --- Number of Read Commands
|
||||
0x01 0x038 6 2451000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 90 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 26062 --- Power-on Hours
|
||||
0x01 0x018 6 51500994044 --- Logical Sectors Written
|
||||
0x01 0x020 6 1506558909 --- Number of Write Commands
|
||||
0x01 0x028 6 193790666 --- Logical Sectors Read
|
||||
0x01 0x030 6 6053127 --- Number of Read Commands
|
||||
0x01 0x038 6 133000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 63 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 71 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 54 --- Current Temperature
|
||||
0x05 0x008 1 52 --- Current Temperature
|
||||
0x05 0x020 1 68 --- Highest Temperature
|
||||
0x05 0x028 1 28 --- Lowest Temperature
|
||||
0x05 0x058 1 55 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 518 --- Number of Hardware Resets
|
||||
0x06 0x008 4 590 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 7 N-- Percentage Used Endurance Indicator
|
||||
0x07 0x008 1 8 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
@@ -188,8 +188,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 43 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 43 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sun Aug 27 23:47:46 2023 GMT
|
||||
Local Time is: Sun Aug 27 23:53:52 2023 GMT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -73,7 +73,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 054 037 000 - 46
|
||||
190 Airflow_Temperature_Cel -O--CK 055 037 000 - 45
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 1461
|
||||
@@ -133,7 +133,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 46 Celsius
|
||||
Current Temperature: 45 Celsius
|
||||
Power Cycle Min/Max Temperature: 39/49 Celsius
|
||||
Lifetime Min/Max Temperature: 31/63 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
@@ -145,7 +145,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (87)
|
||||
Temperature History Size (Index): 128 (88)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -160,12 +160,12 @@ Page Offset Size Value Flags Description
|
||||
0x01 0x020 6 156998780 --- Number of Write Commands
|
||||
0x01 0x028 6 13259205857 --- Logical Sectors Read
|
||||
0x01 0x030 6 188899872 --- Number of Read Commands
|
||||
0x01 0x038 6 2110000 --- Date and Time TimeStamp
|
||||
0x01 0x038 6 2476000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 10548 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 46 --- Current Temperature
|
||||
0x05 0x008 1 45 --- Current Temperature
|
||||
0x05 0x020 1 63 --- Highest Temperature
|
||||
0x05 0x028 1 31 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p8 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Samsung based SSDs
|
||||
@@ -12,10 +12,10 @@ Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: mSATA
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jul 25 14:40:29 2023 AEST
|
||||
Local Time is: Sat Aug 19 02:55:22 2023 AEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -30,8 +30,8 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 095 095 000 - 20730
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 228
|
||||
177 Wear_Leveling_Count PO--C- 096 096 000 - 60
|
||||
9 Power_On_Hours -O--CK 095 095 000 - 21315
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 231
|
||||
177 Wear_Leveling_Count PO--C- 095 095 000 - 64
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 045 020 000 - 55
|
||||
190 Airflow_Temperature_Cel -O--CK 049 020 000 - 51
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 154
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 73515102724
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 157
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 83870530287
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -128,9 +128,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 55 Celsius
|
||||
Power Cycle Min/Max Temperature: 40/70 Celsius
|
||||
Device State: Active (0)
|
||||
Current Temperature: 51 Celsius
|
||||
Power Cycle Min/Max Temperature: 38/57 Celsius
|
||||
Lifetime Min/Max Temperature: 30/80 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (42)
|
||||
Temperature History Size (Index): 128 (102)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -150,23 +150,23 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 228 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 20730 --- Power-on Hours
|
||||
0x01 0x018 6 73515102724 --- Logical Sectors Written
|
||||
0x01 0x020 6 826041135 --- Number of Write Commands
|
||||
0x01 0x028 6 1336974370 --- Logical Sectors Read
|
||||
0x01 0x030 6 35555533 --- Number of Read Commands
|
||||
0x01 0x038 6 646000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 231 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 21315 --- Power-on Hours
|
||||
0x01 0x018 6 83870530287 --- Logical Sectors Written
|
||||
0x01 0x020 6 891292655 --- Number of Write Commands
|
||||
0x01 0x028 6 1432257573 --- Logical Sectors Read
|
||||
0x01 0x030 6 38723778 --- Number of Read Commands
|
||||
0x01 0x038 6 2943000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 128 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 131 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 55 --- Current Temperature
|
||||
0x05 0x008 1 51 --- Current Temperature
|
||||
0x05 0x020 1 80 --- Highest Temperature
|
||||
0x05 0x028 1 30 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 985 --- Number of Hardware Resets
|
||||
0x06 0x008 4 1013 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -187,8 +187,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 15 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 15 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jun 1 15:53:03 2024 CEST
|
||||
Local Time is: Wed Oct 9 21:09:54 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 094 094 000 - 27590
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 96
|
||||
177 Wear_Leveling_Count PO--C- 097 097 000 - 52
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 30713
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 98
|
||||
177 Wear_Leveling_Count PO--C- 097 097 000 - 56
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 049 032 000 - 51
|
||||
190 Airflow_Temperature_Cel -O--CK 053 032 000 - 47
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 76
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 28145714917
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 77
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 31212291703
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -128,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 51 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/53 Celsius
|
||||
Current Temperature: 47 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/55 Celsius
|
||||
Lifetime Min/Max Temperature: 24/68 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -140,7 +140,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (9)
|
||||
Temperature History Size (Index): 128 (65)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -149,23 +149,23 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 96 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 27590 --- Power-on Hours
|
||||
0x01 0x018 6 28145714917 --- Logical Sectors Written
|
||||
0x01 0x020 6 697835766 --- Number of Write Commands
|
||||
0x01 0x028 6 17047821039 --- Logical Sectors Read
|
||||
0x01 0x030 6 296384721 --- Number of Read Commands
|
||||
0x01 0x038 6 360000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 98 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 30713 --- Power-on Hours
|
||||
0x01 0x018 6 31212291703 --- Logical Sectors Written
|
||||
0x01 0x020 6 741021812 --- Number of Write Commands
|
||||
0x01 0x028 6 17414499738 --- Logical Sectors Read
|
||||
0x01 0x030 6 307397987 --- Number of Read Commands
|
||||
0x01 0x038 6 3156000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 22 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 51 --- Current Temperature
|
||||
0x05 0x008 1 47 --- Current Temperature
|
||||
0x05 0x020 1 68 --- Highest Temperature
|
||||
0x05 0x028 1 24 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 322 --- Number of Hardware Resets
|
||||
0x06 0x008 4 376 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -186,8 +186,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 41 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 41 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 47 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 47 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Fri Feb 11 12:48:01 2022 PST
|
||||
Local Time is: Sun Mar 20 01:00:01 2022 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 18475
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 44
|
||||
177 Wear_Leveling_Count PO--C- 090 090 000 - 76
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 19342
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 47
|
||||
177 Wear_Leveling_Count PO--C- 090 090 000 - 77
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 071 044 000 - 29
|
||||
190 Airflow_Temperature_Cel -O--CK 069 044 000 - 31
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 12
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 60406870789
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 14
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 60650108189
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -112,25 +112,25 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 18385 -
|
||||
# 2 Short offline Completed without error 00% 18372 -
|
||||
# 3 Short offline Completed without error 00% 18203 -
|
||||
# 4 Short offline Completed without error 00% 18034 -
|
||||
# 5 Short offline Completed without error 00% 17865 -
|
||||
# 6 Short offline Completed without error 00% 17696 -
|
||||
# 7 Extended offline Completed without error 00% 17638 -
|
||||
# 8 Short offline Completed without error 00% 17527 -
|
||||
# 9 Short offline Completed without error 00% 17358 -
|
||||
#10 Short offline Completed without error 00% 17189 -
|
||||
#11 Short offline Completed without error 00% 17020 -
|
||||
#12 Extended offline Completed without error 00% 16891 -
|
||||
#13 Short offline Completed without error 00% 16851 -
|
||||
#14 Short offline Completed without error 00% 16683 -
|
||||
#15 Short offline Completed without error 00% 16551 -
|
||||
#16 Short offline Completed without error 00% 16372 -
|
||||
#17 Short offline Completed without error 00% 16203 -
|
||||
#18 Short offline Completed without error 00% 16023 -
|
||||
#19 Extended offline Completed without error 00% 15885 -
|
||||
# 1 Short offline Completed without error 00% 19208 -
|
||||
# 2 Extended offline Completed without error 00% 19125 -
|
||||
# 3 Short offline Completed without error 00% 19040 -
|
||||
# 4 Short offline Completed without error 00% 18871 -
|
||||
# 5 Short offline Completed without error 00% 18702 -
|
||||
# 6 Short offline Completed without error 00% 18540 -
|
||||
# 7 Extended offline Completed without error 00% 18385 -
|
||||
# 8 Short offline Completed without error 00% 18372 -
|
||||
# 9 Short offline Completed without error 00% 18203 -
|
||||
#10 Short offline Completed without error 00% 18034 -
|
||||
#11 Short offline Completed without error 00% 17865 -
|
||||
#12 Short offline Completed without error 00% 17696 -
|
||||
#13 Extended offline Completed without error 00% 17638 -
|
||||
#14 Short offline Completed without error 00% 17527 -
|
||||
#15 Short offline Completed without error 00% 17358 -
|
||||
#16 Short offline Completed without error 00% 17189 -
|
||||
#17 Short offline Completed without error 00% 17020 -
|
||||
#18 Extended offline Completed without error 00% 16891 -
|
||||
#19 Short offline Completed without error 00% 16851 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -147,8 +147,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/33 Celsius
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/46 Celsius
|
||||
Lifetime Min/Max Temperature: 23/56 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -159,7 +159,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (50)
|
||||
Temperature History Size (Index): 128 (9)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -168,23 +168,23 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 44 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 18475 --- Power-on Hours
|
||||
0x01 0x018 6 60406870789 --- Logical Sectors Written
|
||||
0x01 0x020 6 1443157045 --- Number of Write Commands
|
||||
0x01 0x028 6 36833350361 --- Logical Sectors Read
|
||||
0x01 0x030 6 318382905 --- Number of Read Commands
|
||||
0x01 0x038 6 2420000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 47 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 19342 --- Power-on Hours
|
||||
0x01 0x018 6 60650108189 --- Logical Sectors Written
|
||||
0x01 0x020 6 1454212653 --- Number of Write Commands
|
||||
0x01 0x028 6 37028352114 --- Logical Sectors Read
|
||||
0x01 0x030 6 325599697 --- Number of Read Commands
|
||||
0x01 0x038 6 3305000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 2 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 29 --- Current Temperature
|
||||
0x05 0x008 1 31 --- Current Temperature
|
||||
0x05 0x020 1 56 --- Highest Temperature
|
||||
0x05 0x028 1 23 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 691 --- Number of Hardware Resets
|
||||
0x06 0x008 4 705 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p4 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Nov 6 15:54:33 2023 EST
|
||||
Local Time is: Thu Nov 16 21:43:00 2023 GMT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 3346
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1891
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 13
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 3442
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1975
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 14
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 067 047 000 - 33
|
||||
190 Airflow_Temperature_Cel -O--CK 068 047 000 - 32
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 231
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 17679805399
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 240
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 18693439733
|
||||
252 Unknown_Attribute -O--CK 100 100 000 - 1
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -133,8 +133,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/40 Celsius
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/40 Celsius
|
||||
Lifetime Min/Max Temperature: 12/53 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -145,7 +145,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (67)
|
||||
Temperature History Size (Index): 128 (61)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -154,23 +154,23 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1891 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3346 --- Power-on Hours
|
||||
0x01 0x018 6 17679805399 --- Logical Sectors Written
|
||||
0x01 0x020 6 50974566 --- Number of Write Commands
|
||||
0x01 0x028 6 22974912638 --- Logical Sectors Read
|
||||
0x01 0x030 6 132118002 --- Number of Read Commands
|
||||
0x01 0x038 6 3232000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 1975 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3442 --- Power-on Hours
|
||||
0x01 0x018 6 18693439733 --- Logical Sectors Written
|
||||
0x01 0x020 6 51758033 --- Number of Write Commands
|
||||
0x01 0x028 6 23243136051 --- Logical Sectors Read
|
||||
0x01 0x030 6 132814185 --- Number of Read Commands
|
||||
0x01 0x038 6 1535000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 14 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x008 1 32 --- Current Temperature
|
||||
0x05 0x020 1 53 --- Highest Temperature
|
||||
0x05 0x028 1 12 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 6828 --- Number of Hardware Resets
|
||||
0x06 0x008 4 7123 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -191,8 +191,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 22 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 22 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Sep 13 17:56:42 2024 MSK
|
||||
Local Time is: Fri Sep 13 20:49:26 2024 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,7 +65,7 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 098 098 010 - 16
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 16633
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 16636
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 232
|
||||
177 Wear_Leveling_Count PO--C- 097 097 000 - 68
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 098 098 010 - 16
|
||||
@@ -73,11 +73,11 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 098 098 010 - 16
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 065 056 000 - 35
|
||||
190 Airflow_Temperature_Cel -O--CK 067 056 000 - 33
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 103
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 61080365773
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 61086557868
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -128,7 +128,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/40 Celsius
|
||||
Lifetime Min/Max Temperature: 15/44 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
@@ -140,7 +140,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (58)
|
||||
Temperature History Size (Index): 128 (75)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -150,22 +150,22 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 232 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 16633 --- Power-on Hours
|
||||
0x01 0x018 6 61080365797 --- Logical Sectors Written
|
||||
0x01 0x020 6 2273802010 --- Number of Write Commands
|
||||
0x01 0x028 6 218454484368 --- Logical Sectors Read
|
||||
0x01 0x030 6 3481297467 --- Number of Read Commands
|
||||
0x01 0x038 6 1353000 --- Date and Time TimeStamp
|
||||
0x01 0x010 4 16636 --- Power-on Hours
|
||||
0x01 0x018 6 61086557868 --- Logical Sectors Written
|
||||
0x01 0x020 6 2273874257 --- Number of Write Commands
|
||||
0x01 0x028 6 218454951954 --- Logical Sectors Read
|
||||
0x01 0x030 6 3481317506 --- Number of Read Commands
|
||||
0x01 0x038 6 916000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 35 --- Current Temperature
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x020 1 44 --- Highest Temperature
|
||||
0x05 0x028 1 15 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 2348 --- Number of Hardware Resets
|
||||
0x06 0x008 4 2360 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -186,8 +186,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 19 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 19 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 31 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 31 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Aug 27 23:47:46 2023 GMT
|
||||
Local Time is: Sun Aug 27 23:53:52 2023 GMT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -73,11 +73,11 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 060 050 000 - 40
|
||||
190 Airflow_Temperature_Cel -O--CK 062 050 000 - 38
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 43
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 4716397696
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 4716643784
|
||||
252 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -129,7 +129,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 40 Celsius
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/45 Celsius
|
||||
Lifetime Min/Max Temperature: 26/50 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (63)
|
||||
Temperature History Size (Index): 128 (64)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -152,16 +152,16 @@ Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 96 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1166 --- Power-on Hours
|
||||
0x01 0x018 6 4716397696 --- Logical Sectors Written
|
||||
0x01 0x020 6 54372678 --- Number of Write Commands
|
||||
0x01 0x028 6 2201428290 --- Logical Sectors Read
|
||||
0x01 0x030 6 37032027 --- Number of Read Commands
|
||||
0x01 0x038 6 2598000 --- Date and Time TimeStamp
|
||||
0x01 0x018 6 4716643784 --- Logical Sectors Written
|
||||
0x01 0x020 6 54375203 --- Number of Write Commands
|
||||
0x01 0x028 6 2201454506 --- Logical Sectors Read
|
||||
0x01 0x030 6 37032451 --- Number of Read Commands
|
||||
0x01 0x038 6 2964000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 40 --- Current Temperature
|
||||
0x05 0x008 1 38 --- Current Temperature
|
||||
0x05 0x020 1 50 --- Highest Temperature
|
||||
0x05 0x028 1 26 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p2 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Aug 22 19:07:50 2023 CDT
|
||||
Local Time is: Thu Oct 31 22:03:46 2024 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 554
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 5
|
||||
177 Wear_Leveling_Count PO--C- 098 098 000 - 28
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 11015
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 7
|
||||
177 Wear_Leveling_Count PO--C- 089 089 000 - 250
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 073 060 000 - 27
|
||||
190 Airflow_Temperature_Cel -O--CK 077 060 000 - 23
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 099 099 000 - 902
|
||||
235 POR_Recovery_Count -O--C- 100 100 000 - 0
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 6052887732
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 2
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 38804958020
|
||||
252 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -132,9 +132,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/40 Celsius
|
||||
Lifetime Min/Max Temperature: 24/24 Celsius
|
||||
Current Temperature: 23 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/40 Celsius
|
||||
Lifetime Min/Max Temperature: 20/24 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
@@ -144,7 +144,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (12)
|
||||
Temperature History Size (Index): 128 (66)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -153,27 +153,27 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 5 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 554 --- Power-on Hours
|
||||
0x01 0x018 6 6052887732 --- Logical Sectors Written
|
||||
0x01 0x020 6 64190619 --- Number of Write Commands
|
||||
0x01 0x028 6 26228701 --- Logical Sectors Read
|
||||
0x01 0x030 6 802285 --- Number of Read Commands
|
||||
0x01 0x038 6 1203000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 7 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 11015 --- Power-on Hours
|
||||
0x01 0x018 6 38804958020 --- Logical Sectors Written
|
||||
0x01 0x020 6 467611822 --- Number of Write Commands
|
||||
0x01 0x028 6 74415269 --- Logical Sectors Read
|
||||
0x01 0x030 6 2948695 --- Number of Read Commands
|
||||
0x01 0x038 6 3582000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 27 --- Current Temperature
|
||||
0x05 0x008 1 23 --- Current Temperature
|
||||
0x05 0x020 1 24 --- Highest Temperature
|
||||
0x05 0x028 1 24 --- Lowest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 519 --- Number of Hardware Resets
|
||||
0x06 0x008 4 604 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 902 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 1 N-- Percentage Used Endurance Indicator
|
||||
0x07 0x008 1 10 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
@@ -190,8 +190,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 38 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 38 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun May 26 09:56:35 2024 AEST
|
||||
Local Time is: Tue May 28 13:51:46 2024 AEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 49
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 34
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 62
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 40
|
||||
177 Wear_Leveling_Count PO--C- 100 100 000 - 0
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 080 067 000 - 20
|
||||
190 Airflow_Temperature_Cel -O--CK 077 067 000 - 23
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 15
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 177376233
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 216441339
|
||||
252 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -129,8 +129,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 20 Celsius
|
||||
Power Cycle Min/Max Temperature: 19/40 Celsius
|
||||
Current Temperature: 23 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/40 Celsius
|
||||
Lifetime Min/Max Temperature: 19/40 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (81)
|
||||
Temperature History Size (Index): 128 (31)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -150,23 +150,23 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 34 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 49 --- Power-on Hours
|
||||
0x01 0x018 6 177376233 --- Logical Sectors Written
|
||||
0x01 0x020 6 4513148 --- Number of Write Commands
|
||||
0x01 0x028 6 63749495 --- Logical Sectors Read
|
||||
0x01 0x030 6 1090138 --- Number of Read Commands
|
||||
0x01 0x038 6 3284000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 40 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 62 --- Power-on Hours
|
||||
0x01 0x018 6 216441339 --- Logical Sectors Written
|
||||
0x01 0x020 6 4832670 --- Number of Write Commands
|
||||
0x01 0x028 6 118374530 --- Logical Sectors Read
|
||||
0x01 0x030 6 1916752 --- Number of Read Commands
|
||||
0x01 0x038 6 1920000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 20 --- Current Temperature
|
||||
0x05 0x008 1 23 --- Current Temperature
|
||||
0x05 0x020 1 40 --- Highest Temperature
|
||||
0x05 0x028 1 19 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 98 --- Number of Hardware Resets
|
||||
0x06 0x008 4 128 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -187,8 +187,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jul 2 16:52:05 2024 BST
|
||||
Local Time is: Tue Jul 9 11:15:35 2024 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -60,19 +60,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
|
||||
9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 97
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 43
|
||||
9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 143
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 51
|
||||
177 Wear_Leveling_Count 0x0013 099 099 000 Pre-fail Always - 1
|
||||
179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0
|
||||
181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
182 Erase_Fail_Count_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always - 0
|
||||
187 Uncorrectable_Error_Cnt 0x0032 100 100 000 Old_age Always - 0
|
||||
190 Airflow_Temperature_Cel 0x0032 065 047 000 Old_age Always - 35
|
||||
190 Airflow_Temperature_Cel 0x0032 070 047 000 Old_age Always - 30
|
||||
195 ECC_Error_Rate 0x001a 200 200 000 Old_age Always - 0
|
||||
199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 3
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 478672681
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 480943393
|
||||
252 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 3
|
||||
|
||||
SMART Error Log Version: 1
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun May 26 09:56:35 2024 AEST
|
||||
Local Time is: Tue May 28 13:51:46 2024 AEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 50
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 34
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 62
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 40
|
||||
177 Wear_Leveling_Count PO--C- 100 100 000 - 0
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 071 066 000 - 29
|
||||
190 Airflow_Temperature_Cel -O--CK 076 066 000 - 24
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 15
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 108729938
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 153482242
|
||||
252 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -129,9 +129,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/40 Celsius
|
||||
Lifetime Min/Max Temperature: 20/40 Celsius
|
||||
Current Temperature: 24 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/40 Celsius
|
||||
Lifetime Min/Max Temperature: 19/40 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (81)
|
||||
Temperature History Size (Index): 128 (31)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -150,23 +150,23 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 34 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 50 --- Power-on Hours
|
||||
0x01 0x018 6 108729938 --- Logical Sectors Written
|
||||
0x01 0x020 6 1056502 --- Number of Write Commands
|
||||
0x01 0x028 6 60408353 --- Logical Sectors Read
|
||||
0x01 0x030 6 676074 --- Number of Read Commands
|
||||
0x01 0x038 6 285000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 40 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 62 --- Power-on Hours
|
||||
0x01 0x018 6 153482242 --- Logical Sectors Written
|
||||
0x01 0x020 6 1429768 --- Number of Write Commands
|
||||
0x01 0x028 6 115553850 --- Logical Sectors Read
|
||||
0x01 0x030 6 770740 --- Number of Read Commands
|
||||
0x01 0x038 6 2521000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 29 --- Current Temperature
|
||||
0x05 0x008 1 24 --- Current Temperature
|
||||
0x05 0x020 1 40 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x028 1 19 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 98 --- Number of Hardware Resets
|
||||
0x06 0x008 4 128 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -187,8 +187,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p2 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Aug 9 22:25:36 2023 EDT
|
||||
Local Time is: Sun Oct 22 03:13:19 2023 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 099 099 010 - 2
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 12932
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 14689
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 87
|
||||
177 Wear_Leveling_Count PO--C- 050 050 000 - 1193
|
||||
177 Wear_Leveling_Count PO--C- 046 046 000 - 1291
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 099 099 010 - 2
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 099 099 010 - 2
|
||||
187 Uncorrectable_Error_Cnt -O--CK 099 099 000 - 387
|
||||
190 Airflow_Temperature_Cel -O--CK 064 059 000 - 36
|
||||
190 Airflow_Temperature_Cel -O--CK 064 058 000 - 36
|
||||
195 ECC_Error_Rate -O-RC- 199 199 000 - 387
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 47
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 635312810941
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 688109300258
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -194,8 +194,9 @@ Error 384 [3] occurred at disk power-on lifetime: 8876 hours (369 days + 20 hour
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed: read failure 40% 4375 42169488
|
||||
# 2 Short offline Completed: read failure 40% 3919 42169488
|
||||
# 1 Short offline Completed without error 00% 12933 -
|
||||
# 2 Short offline Completed: read failure 40% 4375 42169488
|
||||
# 3 Short offline Completed: read failure 40% 3919 42169488
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -213,8 +214,8 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/40 Celsius
|
||||
Lifetime Min/Max Temperature: 21/41 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/42 Celsius
|
||||
Lifetime Min/Max Temperature: 21/42 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
@@ -224,7 +225,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (120)
|
||||
Temperature History Size (Index): 128 (37)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -234,26 +235,26 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 87 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 12932 --- Power-on Hours
|
||||
0x01 0x018 6 635312810941 --- Logical Sectors Written
|
||||
0x01 0x020 6 7065379494 --- Number of Write Commands
|
||||
0x01 0x028 6 269122741655 --- Logical Sectors Read
|
||||
0x01 0x030 6 1269024819 --- Number of Read Commands
|
||||
0x01 0x038 6 2824000 --- Date and Time TimeStamp
|
||||
0x01 0x010 4 14689 --- Power-on Hours
|
||||
0x01 0x018 6 688109300258 --- Logical Sectors Written
|
||||
0x01 0x020 6 7513030034 --- Number of Write Commands
|
||||
0x01 0x028 6 288008096638 --- Logical Sectors Read
|
||||
0x01 0x030 6 1380375273 --- Number of Read Commands
|
||||
0x01 0x038 6 2005000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 387 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 36 --- Current Temperature
|
||||
0x05 0x020 1 41 --- Highest Temperature
|
||||
0x05 0x020 1 42 --- Highest Temperature
|
||||
0x05 0x028 1 21 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 253 --- Number of Hardware Resets
|
||||
0x06 0x008 4 329 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 52 N-- Percentage Used Endurance Indicator
|
||||
0x07 0x008 1 56 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
@@ -270,8 +271,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 44 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 35 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 139 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 111 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Oct 1 11:09:57 2023 CEST
|
||||
Local Time is: Sun Oct 1 13:30:26 2023 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,7 +65,7 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 70
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 72
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 66
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 3
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
@@ -73,11 +73,11 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 066 059 000 - 34
|
||||
190 Airflow_Temperature_Cel -O--CK 062 059 000 - 38
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 099 099 000 - 145
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 38
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 1203181919
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 1274871989
|
||||
252 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -130,7 +130,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/40 Celsius
|
||||
Lifetime Min/Max Temperature: 22/41 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
@@ -142,7 +142,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (110)
|
||||
Temperature History Size (Index): 128 (124)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -152,22 +152,22 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 66 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 70 --- Power-on Hours
|
||||
0x01 0x018 6 1203181919 --- Logical Sectors Written
|
||||
0x01 0x020 6 17941768 --- Number of Write Commands
|
||||
0x01 0x028 6 50136044 --- Logical Sectors Read
|
||||
0x01 0x030 6 841886 --- Number of Read Commands
|
||||
0x01 0x038 6 2257000 --- Date and Time TimeStamp
|
||||
0x01 0x010 4 72 --- Power-on Hours
|
||||
0x01 0x018 6 1274871989 --- Logical Sectors Written
|
||||
0x01 0x020 6 19150270 --- Number of Write Commands
|
||||
0x01 0x028 6 58737979 --- Logical Sectors Read
|
||||
0x01 0x030 6 993890 --- Number of Read Commands
|
||||
0x01 0x038 6 3486000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 2899 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 34 --- Current Temperature
|
||||
0x05 0x008 1 38 --- Current Temperature
|
||||
0x05 0x020 1 41 --- Highest Temperature
|
||||
0x05 0x028 1 22 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 6594 --- Number of Hardware Resets
|
||||
0x06 0x008 4 6608 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 145 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -188,8 +188,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 17 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 17 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Jan 8 00:22:57 2024 NZDT
|
||||
Local Time is: Sun Feb 11 23:40:16 2024 NZDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 1870
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 14
|
||||
177 Wear_Leveling_Count PO--C- 079 079 000 - 508
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 2710
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 16
|
||||
177 Wear_Leveling_Count PO--C- 068 068 000 - 754
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 066 052 000 - 34
|
||||
190 Airflow_Temperature_Cel -O--CK 068 050 000 - 32
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 1
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 162565336408
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 247336640528
|
||||
252 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -129,9 +129,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/48 Celsius
|
||||
Lifetime Min/Max Temperature: 22/48 Celsius
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/50 Celsius
|
||||
Lifetime Min/Max Temperature: 22/51 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (107)
|
||||
Temperature History Size (Index): 128 (24)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -150,27 +150,27 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 14 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1870 --- Power-on Hours
|
||||
0x01 0x018 6 162565336408 --- Logical Sectors Written
|
||||
0x01 0x020 6 1221392874 --- Number of Write Commands
|
||||
0x01 0x028 6 7860564986 --- Logical Sectors Read
|
||||
0x01 0x030 6 111998483 --- Number of Read Commands
|
||||
0x01 0x038 6 3080000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 16 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2710 --- Power-on Hours
|
||||
0x01 0x018 6 247336640528 --- Logical Sectors Written
|
||||
0x01 0x020 6 1806216703 --- Number of Write Commands
|
||||
0x01 0x028 6 16700391360 --- Logical Sectors Read
|
||||
0x01 0x030 6 237029928 --- Number of Read Commands
|
||||
0x01 0x038 6 380000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 34 --- Current Temperature
|
||||
0x05 0x020 1 48 --- Highest Temperature
|
||||
0x05 0x008 1 32 --- Current Temperature
|
||||
0x05 0x020 1 51 --- Highest Temperature
|
||||
0x05 0x028 1 22 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 63 --- Number of Hardware Resets
|
||||
0x06 0x008 4 78 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 22 N-- Percentage Used Endurance Indicator
|
||||
0x07 0x008 1 33 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p2 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Aug 26 03:55:12 2023 CDT
|
||||
Local Time is: Tue Oct 17 17:07:51 2023 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 2876
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 62
|
||||
177 Wear_Leveling_Count PO--C- 097 097 000 - 72
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 4137
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 64
|
||||
177 Wear_Leveling_Count PO--C- 076 076 000 - 574
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 058 057 000 - 42
|
||||
190 Airflow_Temperature_Cel -O--CK 063 056 000 - 37
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 096 096 000 - 3638
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 30
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 31828965025
|
||||
199 CRC_Error_Count -OSRCK 094 094 000 - 5770
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 31
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 85157703485
|
||||
252 Unknown_Attribute -O--CK 100 100 000 - 21
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -129,9 +129,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 42 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/43 Celsius
|
||||
Lifetime Min/Max Temperature: 19/43 Celsius
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/38 Celsius
|
||||
Lifetime Min/Max Temperature: 19/44 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (38)
|
||||
Temperature History Size (Index): 128 (55)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -150,27 +150,27 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 62 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2876 --- Power-on Hours
|
||||
0x01 0x018 6 31828965129 --- Logical Sectors Written
|
||||
0x01 0x020 6 365450218 --- Number of Write Commands
|
||||
0x01 0x028 6 100032069 --- Logical Sectors Read
|
||||
0x01 0x030 6 1831637 --- Number of Read Commands
|
||||
0x01 0x038 6 1028000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 64 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 4137 --- Power-on Hours
|
||||
0x01 0x018 6 85157707493 --- Logical Sectors Written
|
||||
0x01 0x020 6 1609395200 --- Number of Write Commands
|
||||
0x01 0x028 6 122418812 --- Logical Sectors Read
|
||||
0x01 0x030 6 2221788 --- Number of Read Commands
|
||||
0x01 0x038 6 1677000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 42 --- Current Temperature
|
||||
0x05 0x020 1 43 --- Highest Temperature
|
||||
0x05 0x008 1 37 --- Current Temperature
|
||||
0x05 0x020 1 44 --- Highest Temperature
|
||||
0x05 0x028 1 19 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 3201 --- Number of Hardware Resets
|
||||
0x06 0x008 4 4855 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 3638 --- Number of Interface CRC Errors
|
||||
0x06 0x018 4 5770 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 3 N-- Percentage Used Endurance Indicator
|
||||
0x07 0x008 1 25 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
@@ -179,22 +179,22 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 1313 Command failed due to ICRC error
|
||||
0x0001 2 7 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 1 R_ERR response for non-data FIS
|
||||
0x0006 2 1 R_ERR response for device-to-host non-data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 1085 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 1085 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 26 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 22 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 1 Non-CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 1 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
|
||||
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Jan 8 00:22:57 2024 NZDT
|
||||
Local Time is: Sun Feb 11 23:40:16 2024 NZDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 1871
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 14
|
||||
177 Wear_Leveling_Count PO--C- 078 078 000 - 525
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 2710
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 16
|
||||
177 Wear_Leveling_Count PO--C- 067 067 000 - 777
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 066 053 000 - 34
|
||||
190 Airflow_Temperature_Cel -O--CK 069 050 000 - 31
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 1
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 162567248273
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 247338552313
|
||||
252 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -129,9 +129,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/47 Celsius
|
||||
Lifetime Min/Max Temperature: 22/47 Celsius
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/49 Celsius
|
||||
Lifetime Min/Max Temperature: 22/49 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (107)
|
||||
Temperature History Size (Index): 128 (24)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -150,27 +150,27 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 14 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1871 --- Power-on Hours
|
||||
0x01 0x018 6 162567248273 --- Logical Sectors Written
|
||||
0x01 0x020 6 1200375866 --- Number of Write Commands
|
||||
0x01 0x028 6 7793139766 --- Logical Sectors Read
|
||||
0x01 0x030 6 111054753 --- Number of Read Commands
|
||||
0x01 0x038 6 46000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 16 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2710 --- Power-on Hours
|
||||
0x01 0x018 6 247338552313 --- Logical Sectors Written
|
||||
0x01 0x020 6 1780401008 --- Number of Write Commands
|
||||
0x01 0x028 6 16594187350 --- Logical Sectors Read
|
||||
0x01 0x030 6 235583424 --- Number of Read Commands
|
||||
0x01 0x038 6 948000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 34 --- Current Temperature
|
||||
0x05 0x020 1 47 --- Highest Temperature
|
||||
0x05 0x008 1 31 --- Current Temperature
|
||||
0x05 0x020 1 49 --- Highest Temperature
|
||||
0x05 0x028 1 22 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 63 --- Number of Hardware Resets
|
||||
0x06 0x008 4 78 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 23 N-- Percentage Used Endurance Indicator
|
||||
0x07 0x008 1 34 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p3 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Oct 4 16:08:04 2023 +10
|
||||
Local Time is: Mon Sep 2 04:23:07 2024 +10
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,20 +65,20 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 1615
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 27
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 5487
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 37
|
||||
177 Wear_Leveling_Count PO--C- 100 100 000 - 0
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 067 061 000 - 33
|
||||
190 Airflow_Temperature_Cel -O--CK 069 059 000 - 31
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 15
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 1254074331
|
||||
252 Unknown_Attribute -O--CK 100 100 000 - 1
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 19
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 4437217937
|
||||
252 Unknown_Attribute -O--CK 100 100 000 - 2
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -129,9 +129,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/40 Celsius
|
||||
Lifetime Min/Max Temperature: 25/40 Celsius
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/36 Celsius
|
||||
Lifetime Min/Max Temperature: 23/41 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (10)
|
||||
Temperature History Size (Index): 128 (83)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -150,23 +150,23 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 27 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1615 --- Power-on Hours
|
||||
0x01 0x018 6 1254074331 --- Logical Sectors Written
|
||||
0x01 0x020 6 19777560 --- Number of Write Commands
|
||||
0x01 0x028 6 125867518 --- Logical Sectors Read
|
||||
0x01 0x030 6 5581043 --- Number of Read Commands
|
||||
0x01 0x038 6 3193000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 37 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 5487 --- Power-on Hours
|
||||
0x01 0x018 6 4437217937 --- Logical Sectors Written
|
||||
0x01 0x020 6 65028636 --- Number of Write Commands
|
||||
0x01 0x028 6 261873517 --- Logical Sectors Read
|
||||
0x01 0x030 6 12096536 --- Number of Read Commands
|
||||
0x01 0x038 6 1986000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x020 1 40 --- Highest Temperature
|
||||
0x05 0x028 1 25 --- Lowest Temperature
|
||||
0x05 0x008 1 31 --- Current Temperature
|
||||
0x05 0x020 1 41 --- Highest Temperature
|
||||
0x05 0x028 1 23 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 179 --- Number of Hardware Resets
|
||||
0x06 0x008 4 298 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -187,8 +187,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 11 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 11 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Oct 17 17:07:51 2023 CDT
|
||||
Local Time is: Wed Oct 18 15:33:00 2023 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 2132
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 14
|
||||
177 Wear_Leveling_Count PO--C- 076 076 000 - 571
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 2151
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 15
|
||||
177 Wear_Leveling_Count PO--C- 076 076 000 - 577
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 064 057 000 - 36
|
||||
190 Airflow_Temperature_Cel -O--CK 061 057 000 - 39
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 096 096 000 - 3947
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 7
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 82745657793
|
||||
199 CRC_Error_Count -OSRCK 096 096 000 - 4005
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 8
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 83286635905
|
||||
252 Unknown_Attribute -O--CK 100 100 000 - 1
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -129,8 +129,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/37 Celsius
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/40 Celsius
|
||||
Lifetime Min/Max Temperature: 25/43 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (15)
|
||||
Temperature History Size (Index): 128 (1)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -150,25 +150,25 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 14 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2132 --- Power-on Hours
|
||||
0x01 0x018 6 82745657801 --- Logical Sectors Written
|
||||
0x01 0x020 6 1580856610 --- Number of Write Commands
|
||||
0x01 0x028 6 34823624 --- Logical Sectors Read
|
||||
0x01 0x030 6 654819 --- Number of Read Commands
|
||||
0x01 0x038 6 3581000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 15 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2151 --- Power-on Hours
|
||||
0x01 0x018 6 83286635905 --- Logical Sectors Written
|
||||
0x01 0x020 6 1588631856 --- Number of Write Commands
|
||||
0x01 0x028 6 37815684 --- Logical Sectors Read
|
||||
0x01 0x030 6 702467 --- Number of Read Commands
|
||||
0x01 0x038 6 2702000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 36 --- Current Temperature
|
||||
0x05 0x008 1 39 --- Current Temperature
|
||||
0x05 0x020 1 43 --- Highest Temperature
|
||||
0x05 0x028 1 25 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 2972 --- Number of Hardware Resets
|
||||
0x06 0x008 4 3023 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 3947 --- Number of Interface CRC Errors
|
||||
0x06 0x018 4 4005 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 25 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
@@ -179,7 +179,7 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 10 Command failed due to ICRC error
|
||||
0x0001 2 25 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
@@ -187,8 +187,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 25 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 21 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 27 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 24 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Apr 13 05:34:49 2024 UTC
|
||||
Local Time is: Sun May 26 00:33:46 2024 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -33,9 +33,8 @@ General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Self-test execution status: ( 17) The self-test routine was aborted by
|
||||
the host.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
@@ -65,19 +64,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 17282
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 18309
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 68
|
||||
177 Wear_Leveling_Count PO--C- 076 076 000 - 237
|
||||
177 Wear_Leveling_Count PO--C- 058 058 000 - 417
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 060 043 000 - 40
|
||||
190 Airflow_Temperature_Cel -O--CK 050 043 000 - 50
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 099 099 000 - 5
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 51
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 208035975997
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 238882354677
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -111,7 +110,8 @@ SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Aborted by host 10% 17849 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -128,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 40 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/51 Celsius
|
||||
Current Temperature: 50 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/57 Celsius
|
||||
Lifetime Min/Max Temperature: 15/57 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -140,7 +140,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (113)
|
||||
Temperature History Size (Index): 128 (3)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -150,26 +150,26 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 68 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 17282 --- Power-on Hours
|
||||
0x01 0x018 6 208035975997 --- Logical Sectors Written
|
||||
0x01 0x020 6 2048023056 --- Number of Write Commands
|
||||
0x01 0x028 6 11860125312 --- Logical Sectors Read
|
||||
0x01 0x030 6 111588915 --- Number of Read Commands
|
||||
0x01 0x038 6 1637000 --- Date and Time TimeStamp
|
||||
0x01 0x010 4 18309 --- Power-on Hours
|
||||
0x01 0x018 6 238882354821 --- Logical Sectors Written
|
||||
0x01 0x020 6 2267303683 --- Number of Write Commands
|
||||
0x01 0x028 6 11872775016 --- Logical Sectors Read
|
||||
0x01 0x030 6 112000685 --- Number of Read Commands
|
||||
0x01 0x038 6 1519000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 10 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 15 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 40 --- Current Temperature
|
||||
0x05 0x008 1 50 --- Current Temperature
|
||||
0x05 0x020 1 57 --- Highest Temperature
|
||||
0x05 0x028 1 15 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 522 --- Number of Hardware Resets
|
||||
0x06 0x008 4 547 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 5 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 24 N-- Percentage Used Endurance Indicator
|
||||
0x07 0x008 1 43 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
@@ -179,18 +179,18 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0002 2 5 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0004 2 5 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 39 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 39 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x0009 2 64 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 64 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 5 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x000f 2 5 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p1 amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Sep 4 01:00:01 2022 PDT
|
||||
Local Time is: Sun Sep 11 01:00:01 2022 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,7 +65,7 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 6897
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 7065
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 23
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 9
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
@@ -73,11 +73,11 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 065 041 000 - 35
|
||||
190 Airflow_Temperature_Cel -O--CK 064 041 000 - 36
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 9
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 17229971788
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 17503462020
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -137,7 +137,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/53 Celsius
|
||||
Lifetime Min/Max Temperature: 25/59 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
@@ -149,7 +149,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (73)
|
||||
Temperature History Size (Index): 128 (57)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -159,22 +159,22 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 23 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 6897 --- Power-on Hours
|
||||
0x01 0x018 6 17229971788 --- Logical Sectors Written
|
||||
0x01 0x020 6 202109435 --- Number of Write Commands
|
||||
0x01 0x028 6 3059439779 --- Logical Sectors Read
|
||||
0x01 0x030 6 58798498 --- Number of Read Commands
|
||||
0x01 0x038 6 1396000 --- Date and Time TimeStamp
|
||||
0x01 0x010 4 7065 --- Power-on Hours
|
||||
0x01 0x018 6 17503462020 --- Logical Sectors Written
|
||||
0x01 0x020 6 206291844 --- Number of Write Commands
|
||||
0x01 0x028 6 3084730682 --- Logical Sectors Read
|
||||
0x01 0x030 6 59885582 --- Number of Read Commands
|
||||
0x01 0x038 6 1390000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 35 --- Current Temperature
|
||||
0x05 0x008 1 36 --- Current Temperature
|
||||
0x05 0x020 1 59 --- Highest Temperature
|
||||
0x05 0x028 1 25 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 320 --- Number of Hardware Resets
|
||||
0x06 0x008 4 325 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -195,8 +195,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 33 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 33 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 38 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 38 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Apr 5 16:08:33 2024 CEST
|
||||
Local Time is: Tue Apr 16 12:05:00 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -60,19 +60,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
|
||||
9 Power_On_Hours 0x0032 097 097 000 Old_age Always - 14931
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 46
|
||||
9 Power_On_Hours 0x0032 096 096 000 Old_age Always - 15190
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 62
|
||||
177 Wear_Leveling_Count 0x0013 099 099 000 Pre-fail Always - 2
|
||||
179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0
|
||||
181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
182 Erase_Fail_Count_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always - 0
|
||||
187 Uncorrectable_Error_Cnt 0x0032 100 100 000 Old_age Always - 0
|
||||
190 Airflow_Temperature_Cel 0x0032 072 043 000 Old_age Always - 28
|
||||
190 Airflow_Temperature_Cel 0x0032 070 043 000 Old_age Always - 30
|
||||
195 ECC_Error_Rate 0x001a 200 200 000 Old_age Always - 0
|
||||
199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 21
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 6193187301
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 24
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 6201628117
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Apr 5 16:08:33 2024 CEST
|
||||
Local Time is: Tue Apr 16 12:05:00 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -60,19 +60,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
|
||||
9 Power_On_Hours 0x0032 097 097 000 Old_age Always - 14931
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 46
|
||||
177 Wear_Leveling_Count 0x0013 099 099 000 Pre-fail Always - 2
|
||||
9 Power_On_Hours 0x0032 096 096 000 Old_age Always - 15190
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 62
|
||||
177 Wear_Leveling_Count 0x0013 099 099 000 Pre-fail Always - 3
|
||||
179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0
|
||||
181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
182 Erase_Fail_Count_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always - 0
|
||||
187 Uncorrectable_Error_Cnt 0x0032 100 100 000 Old_age Always - 0
|
||||
190 Airflow_Temperature_Cel 0x0032 073 046 000 Old_age Always - 27
|
||||
190 Airflow_Temperature_Cel 0x0032 071 046 000 Old_age Always - 29
|
||||
195 ECC_Error_Rate 0x001a 200 200 000 Old_age Always - 0
|
||||
199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 21
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 6374281552
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 24
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 6383220416
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Apr 5 16:08:33 2024 CEST
|
||||
Local Time is: Tue Apr 16 12:05:00 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -60,19 +60,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
|
||||
9 Power_On_Hours 0x0032 097 097 000 Old_age Always - 14931
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 46
|
||||
9 Power_On_Hours 0x0032 096 096 000 Old_age Always - 15190
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 62
|
||||
177 Wear_Leveling_Count 0x0013 099 099 000 Pre-fail Always - 2
|
||||
179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0
|
||||
181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
182 Erase_Fail_Count_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always - 0
|
||||
187 Uncorrectable_Error_Cnt 0x0032 100 100 000 Old_age Always - 0
|
||||
190 Airflow_Temperature_Cel 0x0032 070 049 000 Old_age Always - 30
|
||||
190 Airflow_Temperature_Cel 0x0032 069 049 000 Old_age Always - 31
|
||||
195 ECC_Error_Rate 0x001a 200 200 000 Old_age Always - 0
|
||||
199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 21
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 6138605876
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 24
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 6147271076
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Apr 5 16:08:33 2024 CEST
|
||||
Local Time is: Tue Apr 16 12:05:00 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -60,19 +60,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
|
||||
9 Power_On_Hours 0x0032 097 097 000 Old_age Always - 14931
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 46
|
||||
9 Power_On_Hours 0x0032 096 096 000 Old_age Always - 15190
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 62
|
||||
177 Wear_Leveling_Count 0x0013 099 099 000 Pre-fail Always - 2
|
||||
179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0
|
||||
181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
182 Erase_Fail_Count_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always - 0
|
||||
187 Uncorrectable_Error_Cnt 0x0032 100 100 000 Old_age Always - 0
|
||||
190 Airflow_Temperature_Cel 0x0032 071 047 000 Old_age Always - 29
|
||||
190 Airflow_Temperature_Cel 0x0032 070 047 000 Old_age Always - 30
|
||||
195 ECC_Error_Rate 0x001a 200 200 000 Old_age Always - 0
|
||||
199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 21
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 6336058912
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 24
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 6347924048
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p1 amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Sep 4 01:00:01 2022 PDT
|
||||
Local Time is: Sun Sep 11 01:00:01 2022 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,7 +65,7 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 6896
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 7064
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 23
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 9
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
@@ -77,7 +77,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 9
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 17228220132
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 17501684540
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -148,7 +148,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (75)
|
||||
Temperature History Size (Index): 128 (59)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -158,12 +158,12 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 23 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 6896 --- Power-on Hours
|
||||
0x01 0x018 6 17228220132 --- Logical Sectors Written
|
||||
0x01 0x020 6 204129895 --- Number of Write Commands
|
||||
0x01 0x028 6 3072871315 --- Logical Sectors Read
|
||||
0x01 0x030 6 58875243 --- Number of Read Commands
|
||||
0x01 0x038 6 3185000 --- Date and Time TimeStamp
|
||||
0x01 0x010 4 7064 --- Power-on Hours
|
||||
0x01 0x018 6 17501684540 --- Logical Sectors Written
|
||||
0x01 0x020 6 208355471 --- Number of Write Commands
|
||||
0x01 0x028 6 3098203754 --- Logical Sectors Read
|
||||
0x01 0x030 6 59961894 --- Number of Read Commands
|
||||
0x01 0x038 6 3173000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
@@ -173,7 +173,7 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x028 1 24 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 320 --- Number of Hardware Resets
|
||||
0x06 0x008 4 325 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -194,8 +194,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 33 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 33 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 38 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 38 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Apr 5 16:08:33 2024 CEST
|
||||
Local Time is: Tue Apr 16 12:05:00 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -60,19 +60,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
|
||||
9 Power_On_Hours 0x0032 097 097 000 Old_age Always - 14931
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 46
|
||||
9 Power_On_Hours 0x0032 096 096 000 Old_age Always - 15190
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 62
|
||||
177 Wear_Leveling_Count 0x0013 099 099 000 Pre-fail Always - 2
|
||||
179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0
|
||||
181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
182 Erase_Fail_Count_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always - 0
|
||||
187 Uncorrectable_Error_Cnt 0x0032 100 100 000 Old_age Always - 0
|
||||
190 Airflow_Temperature_Cel 0x0032 071 044 000 Old_age Always - 29
|
||||
190 Airflow_Temperature_Cel 0x0032 070 044 000 Old_age Always - 30
|
||||
195 ECC_Error_Rate 0x001a 200 200 000 Old_age Always - 0
|
||||
199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 21
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 6279683369
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 24
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 6286120569
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Apr 5 16:08:33 2024 CEST
|
||||
Local Time is: Tue Apr 16 12:05:00 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -60,19 +60,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
|
||||
9 Power_On_Hours 0x0032 097 097 000 Old_age Always - 14931
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 46
|
||||
9 Power_On_Hours 0x0032 096 096 000 Old_age Always - 15190
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 62
|
||||
177 Wear_Leveling_Count 0x0013 099 099 000 Pre-fail Always - 2
|
||||
179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0
|
||||
181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
182 Erase_Fail_Count_Total 0x0032 100 100 010 Old_age Always - 0
|
||||
183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always - 0
|
||||
187 Uncorrectable_Error_Cnt 0x0032 100 100 000 Old_age Always - 0
|
||||
190 Airflow_Temperature_Cel 0x0032 071 041 000 Old_age Always - 29
|
||||
190 Airflow_Temperature_Cel 0x0032 070 041 000 Old_age Always - 30
|
||||
195 ECC_Error_Rate 0x001a 200 200 000 Old_age Always - 0
|
||||
199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 21
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 6237285764
|
||||
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 24
|
||||
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 6241711124
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p1 amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Sep 4 01:00:01 2022 PDT
|
||||
Local Time is: Sun Sep 11 01:00:01 2022 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,7 +65,7 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 6897
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 7065
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 23
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 9
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
@@ -73,11 +73,11 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 065 041 000 - 35
|
||||
190 Airflow_Temperature_Cel -O--CK 064 041 000 - 36
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 9
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 17230170537
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 17503629497
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -137,7 +137,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/49 Celsius
|
||||
Lifetime Min/Max Temperature: 25/59 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
@@ -149,7 +149,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (75)
|
||||
Temperature History Size (Index): 128 (59)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -159,22 +159,22 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 23 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 6897 --- Power-on Hours
|
||||
0x01 0x018 6 17230170537 --- Logical Sectors Written
|
||||
0x01 0x020 6 202303417 --- Number of Write Commands
|
||||
0x01 0x028 6 3062273808 --- Logical Sectors Read
|
||||
0x01 0x030 6 58777851 --- Number of Read Commands
|
||||
0x01 0x038 6 1375000 --- Date and Time TimeStamp
|
||||
0x01 0x010 4 7065 --- Power-on Hours
|
||||
0x01 0x018 6 17503629497 --- Logical Sectors Written
|
||||
0x01 0x020 6 206506454 --- Number of Write Commands
|
||||
0x01 0x028 6 3087877515 --- Logical Sectors Read
|
||||
0x01 0x030 6 59865966 --- Number of Read Commands
|
||||
0x01 0x038 6 1364000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 35 --- Current Temperature
|
||||
0x05 0x008 1 36 --- Current Temperature
|
||||
0x05 0x020 1 59 --- Highest Temperature
|
||||
0x05 0x028 1 25 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 320 --- Number of Hardware Resets
|
||||
0x06 0x008 4 325 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -195,8 +195,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 33 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 33 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 38 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 38 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p6 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ TRIM Command: Available
|
||||
Device is: Not in smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Jul 18 18:57:52 2024 ACST
|
||||
Local Time is: Sun Dec 1 12:25:04 2024 ACDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,10 +65,10 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 001 010 Past 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 757
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 759
|
||||
175 Program_Fail_Count_Chip -O--CK 100 100 010 - 0
|
||||
176 Erase_Fail_Count_Chip -O--CK 100 100 010 - 0
|
||||
177 Wear_Leveling_Count PO--C- 087 087 005 - 153
|
||||
177 Wear_Leveling_Count PO--C- 024 024 005 - 917
|
||||
178 Used_Rsvd_Blk_Cnt_Chip PO--C- 100 001 010 Past 0
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 001 010 Past 0
|
||||
180 Unused_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 2176
|
||||
@@ -76,8 +76,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
195 Hardware_ECC_Recovered -O-RC- 200 200 000 - 0
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 22336615906
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 15372921142
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 335744901989
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 37504906404
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -123,17 +123,17 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 17 Celsius
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/ ? Celsius
|
||||
Lifetime Min/Max Temperature: ?/ ? Celsius
|
||||
Under/Over Temperature Limit Count: 0/93837
|
||||
Under/Over Temperature Limit Count: 0/113401
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 128 (67)
|
||||
Temperature History Size (Index): 128 (40)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -153,8 +153,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 32 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 32 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 20 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 20 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -14,7 +14,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Jul 28 07:12:24 2024 BST
|
||||
Local Time is: Sun Jul 28 08:48:21 2024 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -141,17 +141,17 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 46 Celsius
|
||||
Current Temperature: 49 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/ ? Celsius
|
||||
Lifetime Min/Max Temperature: ?/ ? Celsius
|
||||
Under/Over Temperature Limit Count: 0/89752
|
||||
Under/Over Temperature Limit Count: 0/89769
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 128 (41)
|
||||
Temperature History Size (Index): 128 (50)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
|
Reference in New Issue
Block a user