1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 0, modified: 181)

This commit is contained in:
Andrey Ponomarenko
2023-02-20 11:37:17 +03:00
parent 2ebb2890c1
commit 50023efe62
181 changed files with 3659 additions and 3568 deletions

View File

@@ -1,4 +1,4 @@
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE-p4 amd64] (local build)
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Sun Feb 6 01:00:03 2022 PST
Local Time is: Fri Feb 11 12:48:32 2022 PST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
@@ -27,8 +27,8 @@ Wt Cache Reorder: Enabled
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
@@ -68,13 +68,13 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
4 Start_Stop_Count -O--CK 099 099 000 - 1859
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 061 061 000 - 28810
9 Power_On_Hours -O--CK 061 061 000 - 28941
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 1856
192 Power-Off_Retract_Count -O--CK 199 199 000 - 781
193 Load_Cycle_Count -O--CK 015 015 000 - 555028
194 Temperature_Celsius -O---K 120 107 000 - 30
193 Load_Cycle_Count -O--CK 015 015 000 - 557282
194 Temperature_Celsius -O---K 124 107 000 - 26
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
@@ -112,24 +112,24 @@ No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 28644 -
# 2 Short offline Completed without error 00% 28476 -
# 3 Extended offline Completed without error 00% 28314 -
# 4 Short offline Completed without error 00% 28308 -
# 5 Short offline Completed without error 00% 28182 -
# 6 Short offline Completed without error 00% 28014 -
# 7 Extended offline Completed without error 00% 27852 -
# 8 Short offline Completed without error 00% 27846 -
# 9 Short offline Completed without error 00% 27485 -
#10 Extended offline Completed without error 00% 27426 -
#11 Extended offline Completed without error 00% 27380 -
#12 Extended offline Completed without error 00% 27214 -
#13 Extended offline Completed without error 00% 27049 -
#14 Extended offline Completed without error 00% 26883 -
#15 Extended offline Completed without error 00% 26716 -
#16 Extended offline Completed without error 00% 26552 -
#17 Extended offline Completed without error 00% 26386 -
#18 Extended offline Completed without error 00% 26222 -
# 1 Extended offline Completed without error 00% 28831 -
# 2 Short offline Completed without error 00% 28812 -
# 3 Short offline Completed without error 00% 28644 -
# 4 Short offline Completed without error 00% 28476 -
# 5 Extended offline Completed without error 00% 28314 -
# 6 Short offline Completed without error 00% 28308 -
# 7 Short offline Completed without error 00% 28182 -
# 8 Short offline Completed without error 00% 28014 -
# 9 Extended offline Completed without error 00% 27852 -
#10 Short offline Completed without error 00% 27846 -
#11 Short offline Completed without error 00% 27485 -
#12 Extended offline Completed without error 00% 27426 -
#13 Extended offline Completed without error 00% 27380 -
#14 Extended offline Completed without error 00% 27214 -
#15 Extended offline Completed without error 00% 27049 -
#16 Extended offline Completed without error 00% 26883 -
#17 Extended offline Completed without error 00% 26716 -
#18 Extended offline Completed without error 00% 26552 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
@@ -144,10 +144,10 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: Unknown (16)
Current Temperature: 30 Celsius
Device State: Active (0)
Current Temperature: 26 Celsius
Power Cycle Min/Max Temperature: 24/41 Celsius
Lifetime Min/Max Temperature: ?/43 Celsius
Lifetime Min/Max Temperature: 26/43 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
@@ -155,7 +155,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (130)
Temperature History Size (Index): 478 (382)
SCT Error Recovery Control:
Read: Disabled
@@ -174,9 +174,9 @@ ID Size Value Description
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 1856482 Vendor specific
0x8000 4 2330505 Vendor specific