1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 0, modified: 181)

This commit is contained in:
Andrey Ponomarenko
2023-02-20 11:37:17 +03:00
parent 2ebb2890c1
commit 50023efe62
181 changed files with 3659 additions and 3568 deletions

View File

@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat Jul 16 11:37:45 2022 EDT
Local Time is: Wed Jul 20 17:53:49 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -26,7 +26,9 @@ ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
@@ -64,12 +66,12 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 098 098 000 - 8886
9 Power_On_Hours -O--CK 098 098 000 - 8988
12 Power_Cycle_Count -O--CK 098 098 000 - 2005
170 Unused_Rsvd_Blk_Ct_Chip -O--CK 100 100 010 - 0
171 Program_Fail_Count_Chip -O--CK 100 100 010 - 0
172 Erase_Fail_Count_Chip -O--CK 100 100 010 - 0
173 Wear_Leveling_Count PO--CK 006 006 005 - 1994
173 Wear_Leveling_Count PO--CK 005 005 005 NOW 2009
174 Unexpect_Power_Loss_Ct -O--CK 099 099 000 - 55
178 Used_Rsvd_Blk_Cnt_Chip PO--C- 100 100 010 - 0
180 Unused_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 768
@@ -77,10 +79,10 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
194 Temperature_Celsius -O--CK 076 059 000 - 24
199 CRC_Error_Count -OSRCK 100 100 000 - 0
233 Media_Wearout_Indicator PO--C- 001 001 000 - 50331
241 Total_LBAs_Written -O--CK 099 099 000 - 54739
242 Total_LBAs_Read -O--CK 099 099 000 - 6068
249 NAND_Writes_1GiB -O--CK 099 099 000 - 510672
233 Media_Wearout_Indicator PO--C- 001 001 000 - 216172782038286
241 Total_LBAs_Written -O--CK 099 099 000 - 55047
242 Total_LBAs_Read -O--CK 099 099 000 - 6074
249 NAND_Writes_1GiB -O--CK 099 099 000 - 514480
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -129,7 +131,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: SCT command executing in background (5)
Current Temperature: 23 Celsius
Current Temperature: 24 Celsius
Power Cycle Min/Max Temperature: 21/40 Celsius
Lifetime Min/Max Temperature: 0/70 Celsius
Under/Over Temperature Limit Count: 4294967295/4294901760
@@ -140,7 +142,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (93)
Temperature History Size (Index): 128 (67)
SCT Error Recovery Control:
Read: Disabled
@@ -160,8 +162,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 71 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 71 Device-to-host register FISes sent due to a COMRESET
0x0009 2 89 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 89 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC

View File

@@ -1,5 +1,5 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p15-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
@@ -11,10 +11,10 @@ User Capacity: 250,059,350,016 bytes [250 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available
Device is: In smartctl database [for details use: -P show]
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Apr 8 21:58:34 2021 CEST
Local Time is: Fri Aug 12 18:50:31 2022 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -64,19 +64,19 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 095 095 000 - 21454
12 Power_Cycle_Count -O--CK 098 098 000 - 1214
177 Wear_Leveling_Count PO--C- 083 083 000 - 200
9 Power_On_Hours -O--CK 092 092 000 - 36815
12 Power_Cycle_Count -O--CK 098 098 000 - 1219
177 Wear_Leveling_Count PO--C- 077 077 000 - 267
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 062 052 000 - 38
190 Airflow_Temperature_Cel -O--CK 058 051 000 - 42
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 220
241 Total_LBAs_Written -O--CK 099 099 000 - 183161009564
235 POR_Recovery_Count -O--C- 099 099 000 - 222
241 Total_LBAs_Written -O--CK 099 099 000 - 262439204453
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -128,17 +128,17 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 38 Celsius
Current Temperature: 42 Celsius
Power Cycle Min/Max Temperature: ?/ ? Celsius
Lifetime Min/Max Temperature: ?/ ? Celsius
Under/Over Temperature Limit Count: 0/100170
Under/Over Temperature Limit Count: 0/170864
SCT Temperature History Version: 2
Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: ?/ ? Celsius
Min/Max Temperature Limit: ?/ ? Celsius
Temperature History Size (Index): 128 (22)
Temperature History Size (Index): 128 (91)
SCT Error Recovery Control:
Read: Disabled
@@ -158,8 +158,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 39 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 39 Device-to-host register FISes sent due to a COMRESET
0x0009 2 23 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 23 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC

View File

@@ -1,4 +1,4 @@
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE-p4 amd64] (local build)
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Sun Feb 6 01:00:03 2022 PST
Local Time is: Fri Feb 11 12:48:34 2022 PST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 090 090 000 - 49828
9 Power_On_Hours -O--CK 090 090 000 - 49960
12 Power_Cycle_Count -O--CK 098 098 000 - 1805
177 Wear_Leveling_Count PO--C- 096 096 000 - 38
177 Wear_Leveling_Count PO--C- 096 096 000 - 39
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 078 052 000 - 22
190 Airflow_Temperature_Cel -O--CK 077 052 000 - 23
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 099 099 000 - 1
235 POR_Recovery_Count -O--C- 099 099 000 - 516
241 Total_LBAs_Written -O--CK 099 099 000 - 46458617347
241 Total_LBAs_Written -O--CK 099 099 000 - 46621490859
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -110,14 +110,16 @@ No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 349 -
# 2 Short offline Completed without error 00% 180 -
# 3 Extended offline Completed without error 00% 27 -
# 4 Short offline Completed without error 00% 11 -
# 5 Short offline Completed without error 00% 588 -
# 6 Short offline Completed without error 00% 419 -
# 7 Extended offline Completed without error 00% 266 -
# 8 Short offline Completed without error 00% 250 -
# 1 Extended offline Completed without error 00% 549 -
# 2 Short offline Completed without error 00% 519 -
# 3 Short offline Completed without error 00% 349 -
# 4 Short offline Completed without error 00% 180 -
# 5 Extended offline Completed without error 00% 27 -
# 6 Short offline Completed without error 00% 11 -
# 7 Short offline Completed without error 00% 588 -
# 8 Short offline Completed without error 00% 419 -
# 9 Extended offline Completed without error 00% 266 -
#10 Short offline Completed without error 00% 250 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
@@ -133,17 +135,17 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 22 Celsius
Current Temperature: 23 Celsius
Power Cycle Min/Max Temperature: ?/ ? Celsius
Lifetime Min/Max Temperature: ?/ ? Celsius
Under/Over Temperature Limit Count: 0/277539
Under/Over Temperature Limit Count: 0/278330
SCT Temperature History Version: 2
Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: ?/ ? Celsius
Min/Max Temperature Limit: ?/ ? Celsius
Temperature History Size (Index): 128 (18)
Temperature History Size (Index): 128 (33)
SCT Error Recovery Control:
Read: Disabled
@@ -163,8 +165,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC

View File

@@ -1,4 +1,4 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p4 amd64] (local build)
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -15,7 +15,7 @@ TRIM Command: Available
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Sun Apr 11 01:00:02 2021 PDT
Local Time is: Sun Apr 18 01:00:11 2021 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 093 093 000 - 33167
9 Power_On_Hours -O--CK 093 093 000 - 33335
12 Power_Cycle_Count -O--CK 099 099 000 - 341
177 Wear_Leveling_Count PO--C- 099 099 000 - 11
177 Wear_Leveling_Count PO--C- 099 099 000 - 12
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 099 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 059 047 000 - 41
190 Airflow_Temperature_Cel -O--CK 062 047 000 - 38
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 73
241 Total_LBAs_Written -O--CK 099 099 000 - 88895884998
241 Total_LBAs_Written -O--CK 099 099 000 - 89802842318
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -111,25 +111,25 @@ No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 33011 -
# 2 Extended offline Completed without error 00% 32843 -
# 3 Extended offline Completed without error 00% 32675 -
# 4 Extended offline Completed without error 00% 32508 -
# 5 Extended offline Completed without error 00% 32341 -
# 6 Extended offline Completed without error 00% 32173 -
# 7 Extended offline Completed without error 00% 32005 -
# 8 Extended offline Completed without error 00% 31837 -
# 9 Extended offline Completed without error 00% 31669 -
#10 Extended offline Completed without error 00% 31501 -
#11 Extended offline Completed without error 00% 31333 -
#12 Extended offline Completed without error 00% 31165 -
#13 Extended offline Completed without error 00% 31079 -
#14 Extended offline Completed without error 00% 30911 -
#15 Extended offline Completed without error 00% 30743 -
#16 Extended offline Completed without error 00% 30579 -
#17 Extended offline Completed without error 00% 30411 -
#18 Extended offline Completed without error 00% 30243 -
#19 Extended offline Completed without error 00% 30075 -
# 1 Extended offline Completed without error 00% 33179 -
# 2 Extended offline Completed without error 00% 33011 -
# 3 Extended offline Completed without error 00% 32843 -
# 4 Extended offline Completed without error 00% 32675 -
# 5 Extended offline Completed without error 00% 32508 -
# 6 Extended offline Completed without error 00% 32341 -
# 7 Extended offline Completed without error 00% 32173 -
# 8 Extended offline Completed without error 00% 32005 -
# 9 Extended offline Completed without error 00% 31837 -
#10 Extended offline Completed without error 00% 31669 -
#11 Extended offline Completed without error 00% 31501 -
#12 Extended offline Completed without error 00% 31333 -
#13 Extended offline Completed without error 00% 31165 -
#14 Extended offline Completed without error 00% 31079 -
#15 Extended offline Completed without error 00% 30911 -
#16 Extended offline Completed without error 00% 30743 -
#17 Extended offline Completed without error 00% 30579 -
#18 Extended offline Completed without error 00% 30411 -
#19 Extended offline Completed without error 00% 30243 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
@@ -146,8 +146,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 41 Celsius
Power Cycle Min/Max Temperature: 37/48 Celsius
Current Temperature: 38 Celsius
Power Cycle Min/Max Temperature: 32/48 Celsius
Lifetime Min/Max Temperature: 21/53 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -156,7 +156,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (73)
Temperature History Size (Index): 128 (57)
SCT Error Recovery Control:
Read: Disabled
@@ -176,8 +176,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 47 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 47 Device-to-host register FISes sent due to a COMRESET
0x0009 2 131 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 120 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC

View File

@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Nov 25 23:21:22 2020 EST
Local Time is: Thu Nov 26 23:21:01 2020 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -64,7 +64,7 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 094 094 000 - 26550
9 Power_On_Hours -O--CK 094 094 000 - 26574
12 Power_Cycle_Count -O--CK 099 099 000 - 61
177 Wear_Leveling_Count PO--C- 096 096 000 - 65
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
@@ -76,7 +76,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 31
241 Total_LBAs_Written -O--CK 099 099 000 - 41655765701
241 Total_LBAs_Written -O--CK 099 099 000 - 41711321221
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -110,8 +110,9 @@ No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 26542 -
# 2 Short offline Completed without error 00% 26518 -
# 1 Short offline Completed without error 00% 26566 -
# 2 Short offline Completed without error 00% 26542 -
# 3 Short offline Completed without error 00% 26518 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
@@ -138,7 +139,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (88)
Temperature History Size (Index): 128 (104)
SCT Error Recovery Control:
Read: Disabled

View File

@@ -1,4 +1,4 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p3 amd64] (local build)
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p4 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat Aug 21 00:02:29 2021 CEST
Local Time is: Mon Sep 13 01:34:51 2021 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -64,9 +64,9 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 097 097 000 - 14261
12 Power_Cycle_Count -O--CK 060 060 000 - 40230
177 Wear_Leveling_Count PO--C- 089 089 000 - 231
9 Power_On_Hours -O--CK 097 097 000 - 14565
12 Power_Cycle_Count -O--CK 060 060 000 - 40300
177 Wear_Leveling_Count PO--C- 089 089 000 - 232
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
@@ -75,8 +75,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
190 Airflow_Temperature_Cel -O--CK 076 047 000 - 24
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 853
241 Total_LBAs_Written -O--CK 099 099 000 - 113810953800
235 POR_Recovery_Count -O--C- 099 099 000 - 864
241 Total_LBAs_Written -O--CK 099 099 000 - 114008631502
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -137,7 +137,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (66)
Temperature History Size (Index): 128 (80)
SCT Error Recovery Control:
Read: Disabled
@@ -157,8 +157,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC

View File

@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Nov 25 23:21:22 2020 EST
Local Time is: Thu Nov 26 23:21:01 2020 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -64,7 +64,7 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 094 094 000 - 26550
9 Power_On_Hours -O--CK 094 094 000 - 26574
12 Power_Cycle_Count -O--CK 099 099 000 - 61
177 Wear_Leveling_Count PO--C- 097 097 000 - 60
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
@@ -76,7 +76,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 31
241 Total_LBAs_Written -O--CK 099 099 000 - 41656506613
241 Total_LBAs_Written -O--CK 099 099 000 - 41712054949
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -110,8 +110,9 @@ No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 26542 -
# 2 Short offline Completed without error 00% 26518 -
# 1 Short offline Completed without error 00% 26566 -
# 2 Short offline Completed without error 00% 26542 -
# 3 Short offline Completed without error 00% 26518 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
@@ -138,7 +139,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (88)
Temperature History Size (Index): 128 (104)
SCT Error Recovery Control:
Read: Disabled

View File

@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Nov 25 23:21:22 2020 EST
Local Time is: Thu Nov 26 23:21:01 2020 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -64,7 +64,7 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 094 094 000 - 26550
9 Power_On_Hours -O--CK 094 094 000 - 26574
12 Power_Cycle_Count -O--CK 099 099 000 - 61
177 Wear_Leveling_Count PO--C- 096 096 000 - 65
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
@@ -76,7 +76,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 31
241 Total_LBAs_Written -O--CK 099 099 000 - 41478281832
241 Total_LBAs_Written -O--CK 099 099 000 - 41533817864
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -110,8 +110,9 @@ No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 26542 -
# 2 Short offline Completed without error 00% 26518 -
# 1 Short offline Completed without error 00% 26566 -
# 2 Short offline Completed without error 00% 26542 -
# 3 Short offline Completed without error 00% 26518 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
@@ -138,7 +139,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (88)
Temperature History Size (Index): 128 (104)
SCT Error Recovery Control:
Read: Disabled

View File

@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Nov 25 23:21:22 2020 EST
Local Time is: Thu Nov 26 23:21:01 2020 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -64,7 +64,7 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 094 094 000 - 26550
9 Power_On_Hours -O--CK 094 094 000 - 26574
12 Power_Cycle_Count -O--CK 099 099 000 - 61
177 Wear_Leveling_Count PO--C- 097 097 000 - 63
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
@@ -76,7 +76,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 31
241 Total_LBAs_Written -O--CK 099 099 000 - 41655449701
241 Total_LBAs_Written -O--CK 099 099 000 - 41710994085
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -110,8 +110,9 @@ No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 26542 -
# 2 Short offline Completed without error 00% 26518 -
# 1 Short offline Completed without error 00% 26566 -
# 2 Short offline Completed without error 00% 26542 -
# 3 Short offline Completed without error 00% 26518 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
@@ -138,7 +139,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (88)
Temperature History Size (Index): 128 (104)
SCT Error Recovery Control:
Read: Disabled

View File

@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Jul 20 17:47:25 2022 EDT
Local Time is: Wed Jul 20 22:12:47 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,7 +65,7 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 099 099 000 - 4827
9 Power_On_Hours -O--CK 099 099 000 - 4832
12 Power_Cycle_Count -O--CK 072 072 000 - 27581
177 Wear_Leveling_Count PO--C- 099 099 000 - 6
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
@@ -73,7 +73,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 073 037 000 - 27
190 Airflow_Temperature_Cel -O--CK 075 037 000 - 25
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 406
@@ -146,8 +146,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 27 Celsius
Power Cycle Min/Max Temperature: 40/40 Celsius
Current Temperature: 25 Celsius
Power Cycle Min/Max Temperature: 25/40 Celsius
Lifetime Min/Max Temperature: 7/63 Celsius
Specified Max Operating Temperature: 70 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -158,7 +158,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (63)
Temperature History Size (Index): 128 (90)
SCT Error Recovery Control:
Read: Disabled
@@ -168,17 +168,17 @@ Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 27581 --- Lifetime Power-On Resets
0x01 0x010 4 4827 --- Power-on Hours
0x01 0x010 4 4832 --- Power-on Hours
0x01 0x018 6 11263154470 --- Logical Sectors Written
0x01 0x020 6 144538558 --- Number of Write Commands
0x01 0x028 6 17119482821 --- Logical Sectors Read
0x01 0x030 6 228523493 --- Number of Read Commands
0x01 0x038 6 3009000 --- Date and Time TimeStamp
0x01 0x028 6 17119488197 --- Logical Sectors Read
0x01 0x030 6 228523517 --- Number of Read Commands
0x01 0x038 6 931000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 261 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 27 --- Current Temperature
0x05 0x008 1 25 --- Current Temperature
0x05 0x020 1 63 --- Highest Temperature
0x05 0x028 1 7 --- Lowest Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature

View File

@@ -1,5 +1,5 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
@@ -12,10 +12,10 @@ Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Apr 15 14:56:00 2022 EDT
Local Time is: Sat Apr 16 00:23:41 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 099 099 000 - 1454
12 Power_Cycle_Count -O--CK 097 097 000 - 2295
9 Power_On_Hours -O--CK 099 099 000 - 1457
12 Power_Cycle_Count -O--CK 097 097 000 - 2297
177 Wear_Leveling_Count PO--C- 098 098 000 - 30
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 076 047 000 - 24
190 Airflow_Temperature_Cel -O--CK 073 047 000 - 27
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 578
241 Total_LBAs_Written -O--CK 099 099 000 - 10503816287
235 POR_Recovery_Count -O--C- 099 099 000 - 579
241 Total_LBAs_Written -O--CK 099 099 000 - 10517173823
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -128,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 24 Celsius
Power Cycle Min/Max Temperature: 40/40 Celsius
Current Temperature: 27 Celsius
Power Cycle Min/Max Temperature: 24/40 Celsius
Lifetime Min/Max Temperature: 19/58 Celsius
Specified Max Operating Temperature: 70 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -140,7 +140,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (127)
Temperature History Size (Index): 128 (19)
SCT Error Recovery Control:
Read: Disabled
@@ -149,23 +149,23 @@ SCT Error Recovery Control:
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 2295 --- Lifetime Power-On Resets
0x01 0x010 4 1454 --- Power-on Hours
0x01 0x018 6 10503816287 --- Logical Sectors Written
0x01 0x020 6 96066459 --- Number of Write Commands
0x01 0x028 6 14854992879 --- Logical Sectors Read
0x01 0x030 6 200272689 --- Number of Read Commands
0x01 0x038 6 3039000 --- Date and Time TimeStamp
0x01 0x008 4 2297 --- Lifetime Power-On Resets
0x01 0x010 4 1457 --- Power-on Hours
0x01 0x018 6 10517173823 --- Logical Sectors Written
0x01 0x020 6 96183540 --- Number of Write Commands
0x01 0x028 6 14861796503 --- Logical Sectors Read
0x01 0x030 6 200341087 --- Number of Read Commands
0x01 0x038 6 3028000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 466 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 24 --- Current Temperature
0x05 0x008 1 27 --- Current Temperature
0x05 0x020 1 58 --- Highest Temperature
0x05 0x028 1 19 --- Lowest Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 10404 --- Number of Hardware Resets
0x06 0x008 4 10429 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==

View File

@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat Jan 30 05:04:34 2021 GMT
Local Time is: Tue Feb 16 19:39:48 2021 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 099 099 000 - 650
12 Power_Cycle_Count -O--CK 099 099 000 - 334
9 Power_On_Hours -O--CK 099 099 000 - 720
12 Power_Cycle_Count -O--CK 099 099 000 - 356
177 Wear_Leveling_Count PO--C- 099 099 000 - 3
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 061 051 000 - 39
190 Airflow_Temperature_Cel -O--CK 072 051 000 - 28
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 5
241 Total_LBAs_Written -O--CK 099 099 000 - 1683568456
235 POR_Recovery_Count -O--C- 099 099 000 - 6
241 Total_LBAs_Written -O--CK 099 099 000 - 1789801431
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -128,7 +128,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 39 Celsius
Current Temperature: 28 Celsius
Power Cycle Min/Max Temperature: 26/40 Celsius
Lifetime Min/Max Temperature: 21/49 Celsius
Specified Max Operating Temperature: 70 Celsius
@@ -140,7 +140,7 @@ Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (13)
Temperature History Size (Index): 128 (63)
SCT Error Recovery Control:
Read: Disabled
@@ -149,23 +149,23 @@ SCT Error Recovery Control:
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 334 --- Lifetime Power-On Resets
0x01 0x010 4 650 --- Power-on Hours
0x01 0x018 6 1683568456 --- Logical Sectors Written
0x01 0x020 6 24919661 --- Number of Write Commands
0x01 0x028 6 1091368180 --- Logical Sectors Read
0x01 0x030 6 23622400 --- Number of Read Commands
0x01 0x038 6 448000 --- Date and Time TimeStamp
0x01 0x008 4 356 --- Lifetime Power-On Resets
0x01 0x010 4 720 --- Power-on Hours
0x01 0x018 6 1789801431 --- Logical Sectors Written
0x01 0x020 6 25955280 --- Number of Write Commands
0x01 0x028 6 1422262235 --- Logical Sectors Read
0x01 0x030 6 30767633 --- Number of Read Commands
0x01 0x038 6 467000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 6 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 39 --- Current Temperature
0x05 0x008 1 28 --- Current Temperature
0x05 0x020 1 49 --- Highest Temperature
0x05 0x028 1 21 --- Lowest Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 1473 --- Number of Hardware Resets
0x06 0x008 4 1560 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
@@ -186,8 +186,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 9 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC

View File

@@ -1,4 +1,4 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p3 amd64] (local build)
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p4 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Sep 13 04:50:01 2021 PDT
Local Time is: Wed Oct 13 04:50:01 2021 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,7 +65,7 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 095 095 000 - 22662
9 Power_On_Hours -O--CK 095 095 000 - 23382
12 Power_Cycle_Count -O--CK 099 099 000 - 770
177 Wear_Leveling_Count PO--C- 099 099 000 - 3
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
@@ -73,7 +73,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 070 050 000 - 30
190 Airflow_Temperature_Cel -O--CK 072 050 000 - 28
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 407
@@ -127,8 +127,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 30 Celsius
Power Cycle Min/Max Temperature: 28/40 Celsius
Current Temperature: 28 Celsius
Power Cycle Min/Max Temperature: 26/40 Celsius
Lifetime Min/Max Temperature: 13/50 Celsius
Specified Max Operating Temperature: 70 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -139,7 +139,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (50)
Temperature History Size (Index): 128 (18)
SCT Error Recovery Control:
Read: Disabled
@@ -149,22 +149,22 @@ Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 770 --- Lifetime Power-On Resets
0x01 0x010 4 22662 --- Power-on Hours
0x01 0x010 4 23382 --- Power-on Hours
0x01 0x018 6 2312753759 --- Logical Sectors Written
0x01 0x020 6 11601365 --- Number of Write Commands
0x01 0x028 6 1870871393 --- Logical Sectors Read
0x01 0x030 6 13182139 --- Number of Read Commands
0x01 0x038 6 1155000 --- Date and Time TimeStamp
0x01 0x028 6 1870877813 --- Logical Sectors Read
0x01 0x030 6 13182377 --- Number of Read Commands
0x01 0x038 6 1111000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 679 --- Resets Between Cmd Acceptance and Completion
0x04 0x010 4 681 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 30 --- Current Temperature
0x05 0x008 1 28 --- Current Temperature
0x05 0x020 1 50 --- Highest Temperature
0x05 0x028 1 13 --- Lowest Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 11460 --- Number of Hardware Resets
0x06 0x008 4 11468 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
@@ -185,8 +185,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
0x0009 2 15 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 15 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC

View File

@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat Feb 26 22:02:15 2022 EET
Local Time is: Sun Mar 6 18:06:43 2022 EET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,7 +65,7 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 098 098 000 - 6949
9 Power_On_Hours -O--CK 098 098 000 - 7137
12 Power_Cycle_Count -O--CK 099 099 000 - 222
177 Wear_Leveling_Count PO--C- 100 100 000 - 0
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
@@ -77,7 +77,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 170
241 Total_LBAs_Written -O--CK 099 099 000 - 3890548200
241 Total_LBAs_Written -O--CK 099 099 000 - 4168936936
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -130,7 +130,7 @@ SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 30 Celsius
Power Cycle Min/Max Temperature: 30/31 Celsius
Power Cycle Min/Max Temperature: 17/34 Celsius
Lifetime Min/Max Temperature: 14/42 Celsius
Specified Max Operating Temperature: 70 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -141,7 +141,7 @@ Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (38)
Temperature History Size (Index): 128 (14)
SCT Error Recovery Control:
Read: Disabled
@@ -151,12 +151,12 @@ Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 222 --- Lifetime Power-On Resets
0x01 0x010 4 6949 --- Power-on Hours
0x01 0x018 6 3890548200 --- Logical Sectors Written
0x01 0x020 6 56024091 --- Number of Write Commands
0x01 0x028 6 469406684 --- Logical Sectors Read
0x01 0x030 6 7803658 --- Number of Read Commands
0x01 0x038 6 859000 --- Date and Time TimeStamp
0x01 0x010 4 7137 --- Power-on Hours
0x01 0x018 6 4168936936 --- Logical Sectors Written
0x01 0x020 6 60081261 --- Number of Write Commands
0x01 0x028 6 478863212 --- Logical Sectors Read
0x01 0x030 6 7997754 --- Number of Read Commands
0x01 0x038 6 1116000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
@@ -166,7 +166,7 @@ Page Offset Size Value Flags Description
0x05 0x028 1 14 --- Lowest Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 497 --- Number of Hardware Resets
0x06 0x008 4 505 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
@@ -187,8 +187,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x0009 2 10 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC

View File

@@ -1,4 +1,4 @@
smartctl 7.2 2021-09-14 r5236 [MidnightBSD 2.1.6 amd64] (local build)
smartctl 7.2 2021-09-14 r5236 [MidnightBSD 2.1.8 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Mar 21 17:19:47 2022 EDT
Local Time is: Thu Apr 7 17:39:16 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
@@ -58,8 +58,8 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
9 Power_On_Hours 0x0032 093 093 000 Old_age Always - 35282
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 92
9 Power_On_Hours 0x0032 092 092 000 Old_age Always - 35690
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 94
177 Wear_Leveling_Count 0x0013 097 097 000 Pre-fail Always - 39
179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0
181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0
@@ -69,7 +69,7 @@ ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_
190 Airflow_Temperature_Cel 0x0032 075 056 000 Old_age Always - 25
195 ECC_Error_Rate 0x001a 200 200 000 Old_age Always - 0
199 CRC_Error_Count 0x003e 099 099 000 Old_age Always - 52
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 50
235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 51
241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 64024008991
SMART Error Log Version: 1

View File

@@ -1,5 +1,5 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-RELEASE-p1 amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p1 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
@@ -11,10 +11,11 @@ User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Dec 22 23:01:34 2020 GMT
Local Time is: Thu Jan 28 19:59:13 2021 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -64,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 099 099 000 - 372
12 Power_Cycle_Count -O--CK 099 099 000 - 228
9 Power_On_Hours -O--CK 099 099 000 - 400
12 Power_Cycle_Count -O--CK 099 099 000 - 247
177 Wear_Leveling_Count PO--C- 099 099 000 - 4
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 065 050 000 - 35
190 Airflow_Temperature_Cel -O--CK 068 050 000 - 32
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 17
241 Total_LBAs_Written -O--CK 099 099 000 - 3954574824
241 Total_LBAs_Written -O--CK 099 099 000 - 4312725099
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -127,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 29/40 Celsius
Current Temperature: 32 Celsius
Power Cycle Min/Max Temperature: 40/40 Celsius
Lifetime Min/Max Temperature: 22/50 Celsius
Specified Max Operating Temperature: 70 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -139,7 +140,7 @@ Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (93)
Temperature History Size (Index): 128 (16)
SCT Error Recovery Control:
Read: Disabled
@@ -148,23 +149,23 @@ SCT Error Recovery Control:
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 228 --- Lifetime Power-On Resets
0x01 0x010 4 372 --- Power-on Hours
0x01 0x018 6 3954574824 --- Logical Sectors Written
0x01 0x020 6 42370313 --- Number of Write Commands
0x01 0x028 6 1779866049 --- Logical Sectors Read
0x01 0x030 6 23447472 --- Number of Read Commands
0x01 0x038 6 1288000 --- Date and Time TimeStamp
0x01 0x008 4 247 --- Lifetime Power-On Resets
0x01 0x010 4 400 --- Power-on Hours
0x01 0x018 6 4312725099 --- Logical Sectors Written
0x01 0x020 6 46066528 --- Number of Write Commands
0x01 0x028 6 1965228677 --- Logical Sectors Read
0x01 0x030 6 25139414 --- Number of Read Commands
0x01 0x038 6 1386000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 35 --- Current Temperature
0x05 0x008 1 32 --- Current Temperature
0x05 0x020 1 50 --- Highest Temperature
0x05 0x028 1 22 --- Lowest Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 1300 --- Number of Hardware Resets
0x06 0x008 4 1355 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
@@ -185,8 +186,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC

View File

@@ -1,4 +1,4 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p14-HBSD amd64] (local build)
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p15-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Mar 25 21:14:01 2021 UTC
Local Time is: Mon Apr 19 22:13:13 2021 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,18 +65,18 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 099 099 000 - 5001
12 Power_Cycle_Count -O--CK 099 099 000 - 81
9 Power_On_Hours -O--CK 098 098 000 - 5600
12 Power_Cycle_Count -O--CK 099 099 000 - 86
177 Wear_Leveling_Count PO--C- 099 099 000 - 8
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 062 041 000 - 38
190 Airflow_Temperature_Cel -O--CK 056 041 000 - 44
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 67
235 POR_Recovery_Count -O--C- 099 099 000 - 71
241 Total_LBAs_Written -O--CK 099 099 000 - 4050251288
||||||_ K auto-keep
|||||__ C event count
@@ -127,8 +127,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 38 Celsius
Power Cycle Min/Max Temperature: 38/40 Celsius
Current Temperature: 44 Celsius
Power Cycle Min/Max Temperature: 34/48 Celsius
Lifetime Min/Max Temperature: 16/59 Celsius
Specified Max Operating Temperature: 70 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -139,7 +139,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (38)
Temperature History Size (Index): 128 (49)
SCT Error Recovery Control:
Read: Disabled
@@ -148,23 +148,23 @@ SCT Error Recovery Control:
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 81 --- Lifetime Power-On Resets
0x01 0x010 4 5001 --- Power-on Hours
0x01 0x008 4 86 --- Lifetime Power-On Resets
0x01 0x010 4 5600 --- Power-on Hours
0x01 0x018 6 4050251288 --- Logical Sectors Written
0x01 0x020 6 22423398 --- Number of Write Commands
0x01 0x028 6 711569146 --- Logical Sectors Read
0x01 0x030 6 6447957 --- Number of Read Commands
0x01 0x038 6 2372000 --- Date and Time TimeStamp
0x01 0x028 6 711669488 --- Logical Sectors Read
0x01 0x030 6 6452600 --- Number of Read Commands
0x01 0x038 6 276000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 38 --- Current Temperature
0x05 0x008 1 44 --- Current Temperature
0x05 0x020 1 59 --- Highest Temperature
0x05 0x028 1 16 --- Lowest Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 246 --- Number of Hardware Resets
0x06 0x008 4 280 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
@@ -185,8 +185,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC

View File

@@ -1,4 +1,4 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p14-HBSD amd64] (local build)
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p15-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Mar 25 21:14:01 2021 UTC
Local Time is: Mon Apr 19 22:13:13 2021 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 099 099 000 - 5001
12 Power_Cycle_Count -O--CK 099 099 000 - 82
177 Wear_Leveling_Count PO--C- 099 099 000 - 16
9 Power_On_Hours -O--CK 098 098 000 - 5600
12 Power_Cycle_Count -O--CK 099 099 000 - 87
177 Wear_Leveling_Count PO--C- 099 099 000 - 17
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 061 041 000 - 39
190 Airflow_Temperature_Cel -O--CK 057 041 000 - 43
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 68
241 Total_LBAs_Written -O--CK 099 099 000 - 7250399995
235 POR_Recovery_Count -O--C- 099 099 000 - 72
241 Total_LBAs_Written -O--CK 099 099 000 - 7696242936
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -127,8 +127,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 39 Celsius
Power Cycle Min/Max Temperature: 39/41 Celsius
Current Temperature: 43 Celsius
Power Cycle Min/Max Temperature: 34/51 Celsius
Lifetime Min/Max Temperature: 15/58 Celsius
Specified Max Operating Temperature: 55 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -139,7 +139,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (41)
Temperature History Size (Index): 128 (52)
SCT Error Recovery Control:
Read: Disabled
@@ -148,23 +148,23 @@ SCT Error Recovery Control:
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 82 --- Lifetime Power-On Resets
0x01 0x010 4 5001 --- Power-on Hours
0x01 0x018 6 7250399995 --- Logical Sectors Written
0x01 0x020 6 69639829 --- Number of Write Commands
0x01 0x028 6 747336909 --- Logical Sectors Read
0x01 0x030 6 7928948 --- Number of Read Commands
0x01 0x038 6 3562000 --- Date and Time TimeStamp
0x01 0x008 4 87 --- Lifetime Power-On Resets
0x01 0x010 4 5600 --- Power-on Hours
0x01 0x018 6 7696242936 --- Logical Sectors Written
0x01 0x020 6 76285175 --- Number of Write Commands
0x01 0x028 6 765806863 --- Logical Sectors Read
0x01 0x030 6 8367242 --- Number of Read Commands
0x01 0x038 6 1459000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 39 --- Current Temperature
0x05 0x008 1 43 --- Current Temperature
0x05 0x020 1 58 --- Highest Temperature
0x05 0x028 1 15 --- Lowest Temperature
0x05 0x058 1 55 --- Specified Maximum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 253 --- Number of Hardware Resets
0x06 0x008 4 287 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
@@ -185,8 +185,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC

View File

@@ -1,4 +1,4 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p4 amd64] (local build)
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -14,7 +14,7 @@ TRIM Command: Available, deterministic, zeroed
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Sun Apr 11 01:00:02 2021 PDT
Local Time is: Sun Apr 18 01:00:12 2021 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -64,7 +64,7 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 097 097 000 - 11145
9 Power_On_Hours -O--CK 097 097 000 - 11313
12 Power_Cycle_Count -O--CK 099 099 000 - 16
177 Wear_Leveling_Count PO--C- 094 094 000 - 41
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
@@ -72,11 +72,11 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 054 044 000 - 46
190 Airflow_Temperature_Cel -O--CK 062 044 000 - 38
195 Hardware_ECC_Recovered -O-RC- 200 200 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 100 100 000 - 0
235 Unknown_Attribute -O--C- 099 099 000 - 1
241 Total_LBAs_Written -O--CK 099 099 000 - 42468914944
241 Total_LBAs_Written -O--CK 099 099 000 - 43375973778
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -127,9 +127,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 46 Celsius
Power Cycle Min/Max Temperature: 34/52 Celsius
Lifetime Min/Max Temperature: 40/56 Celsius
Current Temperature: 38 Celsius
Power Cycle Min/Max Temperature: 31/52 Celsius
Lifetime Min/Max Temperature: 31/56 Celsius
Specified Max Operating Temperature: 70 Celsius
Under/Over Temperature Limit Count: 0/0
SMART Status: 0xc24f (PASSED)
@@ -139,7 +139,7 @@ Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (77)
Temperature History Size (Index): 128 (61)
SCT Error Recovery Control:
Read: Disabled
@@ -149,22 +149,22 @@ Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 16 --- Lifetime Power-On Resets
0x01 0x010 4 11145 --- Power-on Hours
0x01 0x018 6 42468914944 --- Logical Sectors Written
0x01 0x020 6 1042583837 --- Number of Write Commands
0x01 0x028 6 23187230036 --- Logical Sectors Read
0x01 0x030 6 204087842 --- Number of Read Commands
0x01 0x038 6 3077000 --- Date and Time TimeStamp
0x01 0x010 4 11313 --- Power-on Hours
0x01 0x018 6 43375973778 --- Logical Sectors Written
0x01 0x020 6 1056167490 --- Number of Write Commands
0x01 0x028 6 23605152014 --- Logical Sectors Read
0x01 0x030 6 207254680 --- Number of Read Commands
0x01 0x038 6 3082000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 46 --- Current Temperature
0x05 0x008 1 38 --- Current Temperature
0x05 0x020 1 56 --- Highest Temperature
0x05 0x028 1 40 --- Lowest Temperature
0x05 0x028 1 31 --- Lowest Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 283 --- Number of Hardware Resets
0x06 0x008 4 368 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==

View File

@@ -1,4 +1,4 @@
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE-p7 amd64] (local build)
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE-p8 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Mar 20 01:00:01 2022 PDT
Local Time is: Sun Mar 27 01:00:01 2022 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,7 +65,7 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 099 099 000 - 2876
9 Power_On_Hours -O--CK 099 099 000 - 3044
12 Power_Cycle_Count -O--CK 099 099 000 - 20
177 Wear_Leveling_Count PO--C- 099 099 000 - 2
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
@@ -73,11 +73,11 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 068 050 000 - 32
190 Airflow_Temperature_Cel -O--CK 067 050 000 - 33
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 7
241 Total_LBAs_Written -O--CK 099 099 000 - 5347437540
241 Total_LBAs_Written -O--CK 099 099 000 - 5609580772
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -133,7 +133,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 32 Celsius
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 18/42 Celsius
Lifetime Min/Max Temperature: 25/49 Celsius
Specified Max Operating Temperature: 70 Celsius
@@ -145,7 +145,7 @@ Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (6)
Temperature History Size (Index): 128 (118)
SCT Error Recovery Control:
Read: Disabled
@@ -155,22 +155,22 @@ Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 20 --- Lifetime Power-On Resets
0x01 0x010 4 2876 --- Power-on Hours
0x01 0x018 6 5347437540 --- Logical Sectors Written
0x01 0x020 6 75345541 --- Number of Write Commands
0x01 0x028 6 1546575132 --- Logical Sectors Read
0x01 0x030 6 21002060 --- Number of Read Commands
0x01 0x038 6 39000 --- Date and Time TimeStamp
0x01 0x010 4 3044 --- Power-on Hours
0x01 0x018 6 5609580772 --- Logical Sectors Written
0x01 0x020 6 78956606 --- Number of Write Commands
0x01 0x028 6 1584750700 --- Logical Sectors Read
0x01 0x030 6 22687012 --- Number of Read Commands
0x01 0x038 6 33000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 32 --- Current Temperature
0x05 0x008 1 33 --- Current Temperature
0x05 0x020 1 49 --- Highest Temperature
0x05 0x028 1 25 --- Lowest Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 209 --- Number of Hardware Resets
0x06 0x008 4 224 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
@@ -191,8 +191,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x0009 2 18 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 18 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC

View File

@@ -1,4 +1,4 @@
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE-p7 amd64] (local build)
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE-p8 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Mar 20 01:00:01 2022 PDT
Local Time is: Sun Mar 27 01:00:01 2022 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,7 +65,7 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 099 099 000 - 2875
9 Power_On_Hours -O--CK 099 099 000 - 3043
12 Power_Cycle_Count -O--CK 099 099 000 - 20
177 Wear_Leveling_Count PO--C- 099 099 000 - 2
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
@@ -73,11 +73,11 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 069 051 000 - 31
190 Airflow_Temperature_Cel -O--CK 068 051 000 - 32
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 7
241 Total_LBAs_Written -O--CK 099 099 000 - 5347341964
241 Total_LBAs_Written -O--CK 099 099 000 - 5609496156
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -132,7 +132,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 31 Celsius
Current Temperature: 32 Celsius
Power Cycle Min/Max Temperature: 18/42 Celsius
Lifetime Min/Max Temperature: 24/49 Celsius
Specified Max Operating Temperature: 70 Celsius
@@ -144,7 +144,7 @@ Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (8)
Temperature History Size (Index): 128 (120)
SCT Error Recovery Control:
Read: Disabled
@@ -154,22 +154,22 @@ Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 20 --- Lifetime Power-On Resets
0x01 0x010 4 2875 --- Power-on Hours
0x01 0x018 6 5347341964 --- Logical Sectors Written
0x01 0x020 6 75590552 --- Number of Write Commands
0x01 0x028 6 1551184732 --- Logical Sectors Read
0x01 0x030 6 21015665 --- Number of Read Commands
0x01 0x038 6 2424000 --- Date and Time TimeStamp
0x01 0x010 4 3043 --- Power-on Hours
0x01 0x018 6 5609496156 --- Logical Sectors Written
0x01 0x020 6 79193647 --- Number of Write Commands
0x01 0x028 6 1589325692 --- Logical Sectors Read
0x01 0x030 6 22697628 --- Number of Read Commands
0x01 0x038 6 2414000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 31 --- Current Temperature
0x05 0x008 1 32 --- Current Temperature
0x05 0x020 1 49 --- Highest Temperature
0x05 0x028 1 24 --- Lowest Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 209 --- Number of Hardware Resets
0x06 0x008 4 224 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
@@ -190,8 +190,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x0009 2 18 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 18 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC

View File

@@ -1,4 +1,4 @@
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE-p7 amd64] (local build)
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE-p8 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Mar 20 01:00:01 2022 PDT
Local Time is: Sun Mar 27 01:00:01 2022 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,7 +65,7 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 099 099 000 - 2876
9 Power_On_Hours -O--CK 099 099 000 - 3044
12 Power_Cycle_Count -O--CK 099 099 000 - 20
177 Wear_Leveling_Count PO--C- 099 099 000 - 2
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
@@ -73,11 +73,11 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 068 052 000 - 32
190 Airflow_Temperature_Cel -O--CK 067 052 000 - 33
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 7
241 Total_LBAs_Written -O--CK 099 099 000 - 5347553751
241 Total_LBAs_Written -O--CK 099 099 000 - 5609705719
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -133,7 +133,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 32 Celsius
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 18/42 Celsius
Lifetime Min/Max Temperature: 25/48 Celsius
Specified Max Operating Temperature: 70 Celsius
@@ -145,7 +145,7 @@ Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (8)
Temperature History Size (Index): 128 (120)
SCT Error Recovery Control:
Read: Disabled
@@ -155,22 +155,22 @@ Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 20 --- Lifetime Power-On Resets
0x01 0x010 4 2876 --- Power-on Hours
0x01 0x018 6 5347553751 --- Logical Sectors Written
0x01 0x020 6 75237309 --- Number of Write Commands
0x01 0x028 6 1547603619 --- Logical Sectors Read
0x01 0x030 6 21006770 --- Number of Read Commands
0x01 0x038 6 615000 --- Date and Time TimeStamp
0x01 0x010 4 3044 --- Power-on Hours
0x01 0x018 6 5609705719 --- Logical Sectors Written
0x01 0x020 6 78829676 --- Number of Write Commands
0x01 0x028 6 1586272575 --- Logical Sectors Read
0x01 0x030 6 22693351 --- Number of Read Commands
0x01 0x038 6 606000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 32 --- Current Temperature
0x05 0x008 1 33 --- Current Temperature
0x05 0x020 1 48 --- Highest Temperature
0x05 0x028 1 25 --- Lowest Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 209 --- Number of Hardware Resets
0x06 0x008 4 224 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
@@ -191,8 +191,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x0009 2 18 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 18 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC

View File

@@ -1,4 +1,4 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p3 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Sep 4 12:54:51 2022 BST
Local Time is: Tue Nov 22 19:39:40 2022 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,10 +65,10 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
12 Power_Cycle_Count -O--CK 097 097 000 - 2790
12 Power_Cycle_Count -O--CK 097 097 000 - 2854
175 Program_Fail_Count_Chip -O--CK 100 100 010 - 0
176 Erase_Fail_Count_Chip -O--CK 100 100 010 - 0
177 Wear_Leveling_Count PO--C- 079 079 005 - 250
177 Wear_Leveling_Count PO--C- 079 079 005 - 253
178 Used_Rsvd_Blk_Cnt_Chip PO--C- 100 100 010 - 0
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
180 Unused_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 4423
@@ -76,8 +76,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
241 Total_LBAs_Written -O--CK 099 099 000 - 70721435354
242 Total_LBAs_Read -O--CK 099 099 000 - 76580448705
241 Total_LBAs_Written -O--CK 099 099 000 - 71909147883
242 Total_LBAs_Read -O--CK 099 099 000 - 77963012206
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -141,17 +141,17 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 34 Celsius
Current Temperature: 40 Celsius
Power Cycle Min/Max Temperature: ?/ ? Celsius
Lifetime Min/Max Temperature: ?/ ? Celsius
Under/Over Temperature Limit Count: 0/82015
Under/Over Temperature Limit Count: 0/82501
SCT Temperature History Version: 2
Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: ?/ ? Celsius
Min/Max Temperature Limit: ?/ ? Celsius
Temperature History Size (Index): 128 (11)
Temperature History Size (Index): 128 (3)
SCT Error Recovery Control:
Read: Disabled
@@ -171,8 +171,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 13 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 13 Device-to-host register FISes sent due to a COMRESET
0x0009 2 28 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 28 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC