smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Jul 21 20:39:46 2022 NZST
|
||||
Local Time is: Sun Nov 13 12:08:03 2022 NZDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -62,24 +62,24 @@ SCT capabilities: (0x103b) SCT Status supported.
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 110 099 006 - 26163904
|
||||
1 Raw_Read_Error_Rate POSR-K 107 099 006 - 2240600
|
||||
3 Spin_Up_Time PO---K 100 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 316
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 8
|
||||
7 Seek_Error_Rate POSR-K 087 060 030 - 4784670959
|
||||
9 Power_On_Hours -O--CK 075 075 000 - 22418
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 318
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 24
|
||||
7 Seek_Error_Rate POSR-K 087 060 030 - 4860282779
|
||||
9 Power_On_Hours -O--CK 072 072 000 - 25169
|
||||
10 Spin_Retry_Count PO--CK 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 309
|
||||
180 Unknown_HDD_Attribute PO-R-K 100 100 000 - 2448313348
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 311
|
||||
180 Unknown_HDD_Attribute PO-R-K 100 100 000 - 4294967295
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0 0 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 074 060 045 - 26 (Min/Max 21/28)
|
||||
194 Temperature_Celsius -O---K 026 040 000 - 26 (0 12 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RCK 047 039 000 - 26163904
|
||||
196 Reallocated_Event_Count -O--CK 100 100 036 - 8
|
||||
190 Airflow_Temperature_Cel -O---K 067 060 045 - 33 (Min/Max 23/39)
|
||||
194 Temperature_Celsius -O---K 033 040 000 - 33 (0 12 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RCK 041 033 000 - 2240600
|
||||
196 Reallocated_Event_Count -O--CK 100 100 036 - 24
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
@@ -139,8 +139,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/29 Celsius
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/39 Celsius
|
||||
Lifetime Min/Max Temperature: 12/40 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -149,7 +149,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (87)
|
||||
Temperature History Size (Index): 128 (70)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -161,7 +161,7 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 121 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 19 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Feb 12 09:30:02 2023 CET
|
||||
Local Time is: Thu Feb 16 13:49:17 2023 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 208 (intermediate), recommended: 208
|
||||
@@ -64,12 +64,12 @@ SCT capabilities: (0x303f) SCT Status supported.
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 108 100 006 - 20180264
|
||||
1 Raw_Read_Error_Rate POSR-- 111 100 006 - 41522712
|
||||
3 Spin_Up_Time PO---- 100 100 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 218
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 071 060 030 - 12742049
|
||||
9 Power_On_Hours -O--CK 074 074 000 - 23507
|
||||
7 Seek_Error_Rate POSR-- 071 060 030 - 14273756
|
||||
9 Power_On_Hours -O--CK 074 074 000 - 23607
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 218
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
@@ -77,15 +77,15 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0 0 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 076 065 045 - 24 (Min/Max 16/24)
|
||||
190 Airflow_Temperature_Cel -O---K 076 065 045 - 24 (Min/Max 16/25)
|
||||
194 Temperature_Celsius -O---K 024 040 000 - 24 (0 14 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 040 024 000 - 20180264
|
||||
195 Hardware_ECC_Recovered -O-RC- 039 024 000 - 41522712
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 23504h+32m+33.592s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 2051094209
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 3052630348
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 23604h+51m+48.197s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 297375927
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 3511778414
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -141,7 +141,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 24 Celsius
|
||||
Power Cycle Min/Max Temperature: 16/24 Celsius
|
||||
Power Cycle Min/Max Temperature: 16/25 Celsius
|
||||
Lifetime Min/Max Temperature: 14/35 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -150,7 +150,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (28)
|
||||
Temperature History Size (Index): 128 (2)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -162,7 +162,7 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 13 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 19 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Feb 12 09:30:02 2023 CET
|
||||
Local Time is: Thu Feb 16 13:49:17 2023 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 208 (intermediate), recommended: 208
|
||||
@@ -64,12 +64,12 @@ SCT capabilities: (0x303f) SCT Status supported.
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 108 099 006 - 19908376
|
||||
1 Raw_Read_Error_Rate POSR-- 111 099 006 - 40664032
|
||||
3 Spin_Up_Time PO---- 100 100 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 214
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 081 060 030 - 128103965
|
||||
9 Power_On_Hours -O--CK 074 074 000 - 23507
|
||||
7 Seek_Error_Rate POSR-- 081 060 030 - 129614307
|
||||
9 Power_On_Hours -O--CK 074 074 000 - 23608
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 214
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
@@ -77,15 +77,15 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 0 0 5
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 077 066 045 - 23 (Min/Max 15/24)
|
||||
194 Temperature_Celsius -O---K 023 040 000 - 23 (0 13 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 042 031 000 - 19908376
|
||||
190 Airflow_Temperature_Cel -O---K 076 066 045 - 24 (Min/Max 15/25)
|
||||
194 Temperature_Celsius -O---K 024 040 000 - 24 (0 13 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 041 031 000 - 40664032
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 23504h+57m+16.042s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 3545308155
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1216173479
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 23605h+16m+37.117s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 1510872635
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 37203167
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -140,8 +140,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 23 Celsius
|
||||
Power Cycle Min/Max Temperature: 15/24 Celsius
|
||||
Current Temperature: 24 Celsius
|
||||
Power Cycle Min/Max Temperature: 15/25 Celsius
|
||||
Lifetime Min/Max Temperature: 13/34 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -150,7 +150,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (18)
|
||||
Temperature History Size (Index): 128 (120)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -162,7 +162,7 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 13 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 19 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon Oct 17 11:12:15 2022 CEST
|
||||
Local Time is: Mon Dec 19 16:27:32 2022 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -62,23 +62,23 @@ SCT capabilities: (0x103b) SCT Status supported.
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 118 099 006 - 168483928
|
||||
1 Raw_Read_Error_Rate POSR-K 120 099 006 - 243178160
|
||||
3 Spin_Up_Time PO---K 100 100 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 512
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 515
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 120
|
||||
7 Seek_Error_Rate POSR-K 089 060 030 - 5184957806
|
||||
9 Power_On_Hours -O--CK 025 025 000 - 66570
|
||||
7 Seek_Error_Rate POSR-K 089 060 030 - 5194592329
|
||||
9 Power_On_Hours -O--CK 023 023 000 - 68088
|
||||
10 Spin_Retry_Count PO--CK 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 507
|
||||
180 Unknown_HDD_Attribute PO-R-K 100 100 000 - 1097993710
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 510
|
||||
180 Unknown_HDD_Attribute PO-R-K 100 100 000 - 142004048
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 1 1 9
|
||||
189 High_Fly_Writes -O-RCK 099 099 000 - 1
|
||||
190 Airflow_Temperature_Cel -O---K 070 054 045 - 30 (Min/Max 24/32)
|
||||
194 Temperature_Celsius -O---K 030 046 000 - 30 (0 11 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RCK 029 021 000 - 168483928
|
||||
190 Airflow_Temperature_Cel -O---K 075 054 045 - 25 (Min/Max 23/28)
|
||||
194 Temperature_Celsius -O---K 025 046 000 - 25 (0 11 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RCK 030 021 000 - 243178160
|
||||
196 Reallocated_Event_Count -O--CK 100 100 036 - 120
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
@@ -155,8 +155,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/32 Celsius
|
||||
Current Temperature: 25 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/28 Celsius
|
||||
Lifetime Min/Max Temperature: 11/46 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -165,7 +165,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (38)
|
||||
Temperature History Size (Index): 128 (49)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -177,7 +177,7 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 30 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p3 amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p4 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Aug 21 00:02:29 2021 CEST
|
||||
Local Time is: Mon Sep 13 01:34:51 2021 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -62,25 +62,25 @@ SCT capabilities: (0x10b5) SCT Status supported.
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 118 099 006 - 176436608
|
||||
1 Raw_Read_Error_Rate POSR-K 117 099 006 - 119911768
|
||||
3 Spin_Up_Time PO---K 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 511
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 550
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-K 084 060 030 - 260911417
|
||||
9 Power_On_Hours -O--CK 080 080 000 - 18065
|
||||
7 Seek_Error_Rate POSR-K 084 060 030 - 262958892
|
||||
9 Power_On_Hours -O--CK 080 080 000 - 18368
|
||||
10 Spin_Retry_Count PO--CK 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 898
|
||||
180 Unknown_HDD_Attribute -O-R-K 100 100 000 - 1050589207
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 968
|
||||
180 Unknown_HDD_Attribute -O-R-K 100 100 000 - 1419318500
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 098 000 - 7
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 071 053 045 - 29 (Min/Max 21/31)
|
||||
190 Airflow_Temperature_Cel -O---K 072 053 045 - 28 (Min/Max 21/31)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 230
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 520
|
||||
194 Temperature_Celsius -O---K 029 047 000 - 29 (0 16 0 0 0)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 243
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 559
|
||||
194 Temperature_Celsius -O---K 028 047 000 - 28 (0 16 0 0 0)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
@@ -146,34 +146,34 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/31 Celsius
|
||||
Lifetime Min/Max Temperature: 16/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/12
|
||||
Under/Over Temperature Limit Count: 0/14
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (73)
|
||||
Temperature History Size (Index): 128 (43)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 898 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 18065 --- Power-on Hours
|
||||
0x01 0x018 6 17466367304 --- Logical Sectors Written
|
||||
0x01 0x020 6 626958432 --- Number of Write Commands
|
||||
0x01 0x028 6 9419011117 --- Logical Sectors Read
|
||||
0x01 0x030 6 113578416 --- Number of Read Commands
|
||||
0x01 0x008 4 968 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 18368 --- Power-on Hours
|
||||
0x01 0x018 6 17685247263 --- Logical Sectors Written
|
||||
0x01 0x020 6 631552115 --- Number of Write Commands
|
||||
0x01 0x028 6 9571218109 --- Logical Sectors Read
|
||||
0x01 0x030 6 115087246 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 18047 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 17982 --- Head Flying Hours
|
||||
0x03 0x018 4 520 --- Head Load Events
|
||||
0x03 0x008 4 18349 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 18285 --- Head Flying Hours
|
||||
0x03 0x018 4 559 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
@@ -190,7 +190,7 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p8 amd64] (local build)
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sun Aug 16 14:08:00 2020 IST
|
||||
Local Time is: Sat Sep 5 11:53:57 2020 IST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,30 +64,30 @@ SCT capabilities: (0x1035) SCT Status supported.
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 113 099 006 - 55171896
|
||||
1 Raw_Read_Error_Rate POSR-- 120 099 006 - 240030264
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 096 096 020 - 5000
|
||||
4 Start_Stop_Count -O--CK 095 095 020 - 5139
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 081 060 030 - 4426446465
|
||||
9 Power_On_Hours -O--CK 081 081 000 - 17491 (10 89 0)
|
||||
7 Seek_Error_Rate POSR-- 081 060 030 - 4428738038
|
||||
9 Power_On_Hours -O--CK 080 080 000 - 17824 (13 138 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 096 096 020 - 4985
|
||||
12 Power_Cycle_Count -O--CK 095 095 020 - 5124
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 065 053 045 - 35 (Min/Max 35/35)
|
||||
190 Airflow_Temperature_Cel -O---K 068 053 045 - 32 (Min/Max 32/37)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 177
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 620
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 297316
|
||||
194 Temperature_Celsius -O---K 035 047 000 - 35 (0 19 0 0 0)
|
||||
196 Reallocated_Event_Count POSR-- 082 082 030 - 16606 (39162 0)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 636
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 342385
|
||||
194 Temperature_Celsius -O---K 032 047 000 - 32 (0 19 0 0 0)
|
||||
196 Reallocated_Event_Count POSR-- 081 081 030 - 16848 (36211 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 082 082 000 - 16606 (152 250 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 1725861460
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1686134652
|
||||
240 Head_Flying_Hours ------ 081 081 000 - 16848 (141 115 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 1960268106
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1845837463
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -127,25 +127,25 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 17041 -
|
||||
# 2 Extended offline Completed without error 00% 16929 -
|
||||
# 3 Extended offline Completed without error 00% 16588 -
|
||||
# 4 Extended offline Completed without error 00% 16403 -
|
||||
# 5 Extended offline Completed without error 00% 16356 -
|
||||
# 6 Extended offline Completed without error 00% 16354 -
|
||||
# 7 Extended offline Completed without error 00% 15523 -
|
||||
# 8 Extended offline Completed without error 00% 14208 -
|
||||
# 9 Extended offline Completed without error 00% 13739 -
|
||||
#10 Extended offline Completed without error 00% 13021 -
|
||||
#11 Extended offline Completed without error 00% 12641 -
|
||||
#12 Extended offline Completed without error 00% 11933 -
|
||||
#13 Extended offline Completed without error 00% 11668 -
|
||||
#14 Extended offline Completed without error 00% 11432 -
|
||||
#15 Extended offline Completed without error 00% 11271 -
|
||||
#16 Extended offline Completed without error 00% 10789 -
|
||||
#17 Extended offline Completed without error 00% 9922 -
|
||||
#18 Extended offline Completed without error 00% 9625 -
|
||||
#19 Extended offline Completed without error 00% 9423 -
|
||||
# 1 Extended offline Completed without error 00% 17824 -
|
||||
# 2 Extended offline Completed without error 00% 17041 -
|
||||
# 3 Extended offline Completed without error 00% 16929 -
|
||||
# 4 Extended offline Completed without error 00% 16588 -
|
||||
# 5 Extended offline Completed without error 00% 16403 -
|
||||
# 6 Extended offline Completed without error 00% 16356 -
|
||||
# 7 Extended offline Completed without error 00% 16354 -
|
||||
# 8 Extended offline Completed without error 00% 15523 -
|
||||
# 9 Extended offline Completed without error 00% 14208 -
|
||||
#10 Extended offline Completed without error 00% 13739 -
|
||||
#11 Extended offline Completed without error 00% 13021 -
|
||||
#12 Extended offline Completed without error 00% 12641 -
|
||||
#13 Extended offline Completed without error 00% 11933 -
|
||||
#14 Extended offline Completed without error 00% 11668 -
|
||||
#15 Extended offline Completed without error 00% 11432 -
|
||||
#16 Extended offline Completed without error 00% 11271 -
|
||||
#17 Extended offline Completed without error 00% 10789 -
|
||||
#18 Extended offline Completed without error 00% 9922 -
|
||||
#19 Extended offline Completed without error 00% 9625 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -161,8 +161,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 35/36 Celsius
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/37 Celsius
|
||||
Lifetime Min/Max Temperature: 19/47 Celsius
|
||||
Specified Max Operating Temperature: 36 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -172,7 +172,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 30 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (80)
|
||||
Temperature History Size (Index): 128 (87)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
|