mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 299)
This commit is contained in:
@@ -12,7 +12,7 @@ Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon Dec 19 16:53:52 2022 AEDT
|
||||
Local Time is: Tue Dec 27 07:20:11 2022 AEDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -62,18 +62,18 @@ SCT capabilities: (0x3035) SCT Status supported.
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 5
|
||||
3 Spin_Up_Time POS--K 167 167 021 - 6608
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 532
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 27
|
||||
3 Spin_Up_Time POS--K 187 167 021 - 5616
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 540
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 033 033 000 - 49558
|
||||
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
|
||||
9 Power_On_Hours -O--CK 032 032 000 - 49678
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 339
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 214
|
||||
193 Load_Cycle_Count -O--CK 025 025 000 - 526366
|
||||
194 Temperature_Celsius -O---K 118 104 000 - 32
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 347
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 216
|
||||
193 Load_Cycle_Count -O--CK 025 025 000 - 526484
|
||||
194 Temperature_Celsius -O---K 122 104 000 - 28
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -145,8 +145,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/32 Celsius
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/32 Celsius
|
||||
Lifetime Min/Max Temperature: 0/46 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -155,7 +155,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (248)
|
||||
Temperature History Size (Index): 478 (402)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -174,7 +174,7 @@ ID Size Value Description
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 7807 Vendor specific
|
||||
0x8000 4 48889 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 14.0-CURRENT amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Jan 22 20:04:21 2023 UTC
|
||||
Local Time is: Wed Feb 15 10:11:52 2023
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -37,7 +37,7 @@ Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 3240) seconds.
|
||||
data collection: ( 2760) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
@@ -55,7 +55,7 @@ Error logging capability: (0x01) Error logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 14) minutes.
|
||||
recommended polling time: ( 11) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3031) SCT Status supported.
|
||||
@@ -66,17 +66,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 173 170 021 - 2308
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1268
|
||||
3 Spin_Up_Time POS--K 173 170 021 - 2316
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1473
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2291
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2744
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1192
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 604
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 1571
|
||||
194 Temperature_Celsius -O---K 108 100 000 - 35
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1393
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 684
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2081
|
||||
194 Temperature_Celsius -O---K 109 100 000 - 34
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -141,8 +141,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 35/36 Celsius
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/34 Celsius
|
||||
Lifetime Min/Max Temperature: 18/43 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -154,35 +154,35 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (297)
|
||||
Temperature History Size (Index): 478 (375)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1192 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2291 --- Power-on Hours
|
||||
0x01 0x018 6 26165781499 --- Logical Sectors Written
|
||||
0x01 0x020 6 128559617 --- Number of Write Commands
|
||||
0x01 0x028 6 9268345405 --- Logical Sectors Read
|
||||
0x01 0x030 6 55629477 --- Number of Read Commands
|
||||
0x01 0x038 6 3952632704 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 1393 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2744 --- Power-on Hours
|
||||
0x01 0x018 6 28178959310 --- Logical Sectors Written
|
||||
0x01 0x020 6 132697389 --- Number of Write Commands
|
||||
0x01 0x028 6 9989241502 --- Logical Sectors Read
|
||||
0x01 0x030 6 57396754 --- Number of Read Commands
|
||||
0x01 0x038 6 1288465408 --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 2241 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 1744 --- Head Flying Hours
|
||||
0x03 0x018 4 2176 --- Head Load Events
|
||||
0x03 0x008 4 2690 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 1925 --- Head Flying Hours
|
||||
0x03 0x018 4 2766 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 604 --- Number of High Priority Unload Events
|
||||
0x03 0x040 4 684 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 35 --- Current Temperature
|
||||
0x05 0x010 1 33 --- Average Short Term Temperature
|
||||
0x05 0x008 1 34 --- Current Temperature
|
||||
0x05 0x010 1 35 --- Average Short Term Temperature
|
||||
0x05 0x018 1 34 --- Average Long Term Temperature
|
||||
0x05 0x020 1 43 --- Highest Temperature
|
||||
0x05 0x028 1 22 --- Lowest Temperature
|
||||
@@ -195,8 +195,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 6391 --- Number of Hardware Resets
|
||||
0x06 0x010 4 3474 --- Number of ASR Events
|
||||
0x06 0x008 4 7559 --- Number of Hardware Resets
|
||||
0x06 0x010 4 4110 --- Number of ASR Events
|
||||
0x06 0x018 4 1 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
@@ -219,13 +219,13 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 501 Vendor specific
|
||||
0x8000 4 4444 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon Dec 19 16:53:53 2022 AEDT
|
||||
Local Time is: Tue Dec 27 07:20:11 2022 AEDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,22 +64,22 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 1
|
||||
3 Spin_Up_Time POS--K 174 173 021 - 6258
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 162
|
||||
3 Spin_Up_Time POS--K 176 173 021 - 6200
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 169
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 066 066 000 - 25537
|
||||
9 Power_On_Hours -O--CK 065 065 000 - 25685
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 146
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 72
|
||||
193 Load_Cycle_Count -O--CK 134 134 000 - 200631
|
||||
194 Temperature_Celsius -O---K 121 108 000 - 29
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 153
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 73
|
||||
193 Load_Cycle_Count -O--CK 133 133 000 - 201719
|
||||
194 Temperature_Celsius -O---K 122 108 000 - 28
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 7
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 194 000 - 4
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 194 000 - 7
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -147,7 +147,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/29 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/31 Celsius
|
||||
Lifetime Min/Max Temperature: 15/42 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -159,7 +159,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (110)
|
||||
Temperature History Size (Index): 478 (396)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -182,5 +182,5 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 7808 Vendor specific
|
||||
0x8000 4 48890 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 5200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Fri Feb 11 12:45:03 2022 PST
|
||||
Local Time is: Sun Mar 20 01:00:01 2022 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,17 +66,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 209 201 021 - 4533
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1218
|
||||
3 Spin_Up_Time POS--K 209 201 021 - 4525
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1552
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 5337
|
||||
9 Power_On_Hours -O--CK 092 092 000 - 6202
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 31
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 32
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 33
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 4221
|
||||
194 Temperature_Celsius -O---K 128 099 000 - 24
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 5610
|
||||
194 Temperature_Celsius -O---K 124 099 000 - 28
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -150,8 +150,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 24 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/36 Celsius
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 18/36 Celsius
|
||||
Lifetime Min/Max Temperature: 11/53 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -163,7 +163,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (119)
|
||||
Temperature History Size (Index): 128 (124)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -181,10 +181,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 1579 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 1580 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 919 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 920 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 4889730 Vendor specific
|
||||
0x8000 4 2852709 Vendor specific
|
||||
|
||||
|
Reference in New Issue
Block a user