mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 299)
This commit is contained in:
@@ -11,7 +11,7 @@ User Capacity: 500,106,780,160 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Sat Sep 10 12:39:59 2022 CDT
|
||||
Local Time is: Sat Sep 24 13:32:29 2022 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 128
|
||||
@@ -19,7 +19,7 @@ APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
@@ -63,16 +63,16 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
|
||||
3 Spin_Up_Time PO---- 176 168 021 - 6191
|
||||
4 Start_Stop_Count -O--CK 086 086 000 - 14841
|
||||
3 Spin_Up_Time PO---- 171 168 021 - 6441
|
||||
4 Start_Stop_Count -O--CK 086 086 000 - 14843
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 035 035 000 - 48111
|
||||
9 Power_On_Hours -O--CK 034 034 000 - 48435
|
||||
10 Spin_Retry_Count -O--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3740
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3742
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 113
|
||||
193 Load_Cycle_Count -O--CK 196 196 000 - 14842
|
||||
193 Load_Cycle_Count -O--CK 196 196 000 - 14844
|
||||
194 Temperature_Celsius -O---K 112 084 000 - 38
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
@@ -127,7 +127,7 @@ SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: --/40 Celsius
|
||||
Power Cycle Min/Max Temperature: --/39 Celsius
|
||||
Lifetime Min/Max Temperature: --/66 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -135,7 +135,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/85 Celsius
|
||||
Temperature History Size (Index): 128 (18)
|
||||
Temperature History Size (Index): 128 (105)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -154,6 +154,6 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 22 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 495643 Vendor specific
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 9285 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ Form Factor: 3.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Oct 26 21:37:57 2022 IDT
|
||||
Local Time is: Tue Nov 15 22:44:02 2022 IST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -67,7 +67,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 96
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-K 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 078 078 000 - 16557
|
||||
9 Power_On_Hours -O--CK 079 078 000 - 15845
|
||||
10 Spin_Retry_Count PO--CK 100 253 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 96
|
||||
@@ -75,10 +75,10 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 059 054 040 - 41 (Min/Max 39/46)
|
||||
190 Airflow_Temperature_Cel -O---K 061 054 040 - 39 (Min/Max 38/46)
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 32
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 5599
|
||||
194 Temperature_Celsius -O---K 102 097 000 - 41
|
||||
193 Load_Cycle_Count -O--CK 198 198 000 - 6082
|
||||
194 Temperature_Celsius -O---K 104 097 000 - 39
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -110,7 +110,7 @@ Address Access R/W Size Description
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb5 GPL,SL VS 1 Device vendor specific log
|
||||
0xb6 GPL VS 2518 Device vendor specific log
|
||||
0xb6 GPL VS 2578 Device vendor specific log
|
||||
0xb6 SL VS 1 Device vendor specific log
|
||||
0xb7 GPL,SL VS 48 Device vendor specific log
|
||||
0xbd GPL,SL VS 1 Device vendor specific log
|
||||
@@ -120,7 +120,7 @@ Address Access R/W Size Description
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
Device Error Count: 151 (device log contains only the most recent 24 errors)
|
||||
Device Error Count: 152 (device log contains only the most recent 24 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
@@ -136,6 +136,23 @@ Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 152 [7] occurred at disk power-on lifetime: 15598 hours (649 days + 22 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 4d+19:35:18.718 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 4d+19:35:18.718 SECURITY FREEZE LOCK
|
||||
25 00 00 00 01 00 00 00 00 00 21 e0 00 4d+19:35:18.410 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 4d+19:35:18.410 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 1f e0 00 4d+19:35:18.410 READ DMA EXT
|
||||
|
||||
Error 151 [6] occurred at disk power-on lifetime: 16122 hours (671 days + 18 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
@@ -255,23 +272,6 @@ Error 145 [0] occurred at disk power-on lifetime: 16044 hours (668 days + 12 hou
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 23d+09:44:17.331 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 1f e0 00 23d+09:44:17.331 READ DMA EXT
|
||||
|
||||
Error 144 [23] occurred at disk power-on lifetime: 15482 hours (645 days + 2 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:00:02.760 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:02.760 SECURITY FREEZE LOCK
|
||||
ec 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:02.675 IDENTIFY DEVICE
|
||||
25 00 00 00 01 00 00 00 00 00 21 e0 00 00:00:02.383 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 00:00:02.383 READ DMA EXT
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Aborted by host 90% 14617 -
|
||||
@@ -291,8 +291,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 41 Celsius
|
||||
Power Cycle Min/Max Temperature: 39/47 Celsius
|
||||
Current Temperature: 40 Celsius
|
||||
Power Cycle Min/Max Temperature: 38/47 Celsius
|
||||
Lifetime Min/Max Temperature: 20/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -304,7 +304,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (24)
|
||||
Temperature History Size (Index): 128 (109)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -314,16 +314,16 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 96 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 16557 --- Power-on Hours
|
||||
0x01 0x018 6 21752763608 --- Logical Sectors Written
|
||||
0x01 0x010 4 15845 --- Power-on Hours
|
||||
0x01 0x018 6 21752763612 --- Logical Sectors Written
|
||||
0x01 0x020 6 601074140 --- Number of Write Commands
|
||||
0x01 0x028 6 41879949272 --- Logical Sectors Read
|
||||
0x01 0x030 6 394134178 --- Number of Read Commands
|
||||
0x01 0x038 6 3770625152 --- Date and Time TimeStamp
|
||||
0x01 0x028 6 41879950357 --- Logical Sectors Read
|
||||
0x01 0x030 6 394134400 --- Number of Read Commands
|
||||
0x01 0x038 6 1207425152 --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 19396 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 14364 --- Head Flying Hours
|
||||
0x03 0x018 4 5632 --- Head Load Events
|
||||
0x03 0x008 4 19878 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 14406 --- Head Flying Hours
|
||||
0x03 0x018 4 6115 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
@@ -333,9 +333,9 @@ Page Offset Size Value Flags Description
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 41 --- Current Temperature
|
||||
0x05 0x010 1 41 --- Average Short Term Temperature
|
||||
0x05 0x018 1 41 --- Average Long Term Temperature
|
||||
0x05 0x008 1 39 --- Current Temperature
|
||||
0x05 0x010 1 39 --- Average Short Term Temperature
|
||||
0x05 0x018 1 40 --- Average Long Term Temperature
|
||||
0x05 0x020 1 46 --- Highest Temperature
|
||||
0x05 0x028 1 25 --- Lowest Temperature
|
||||
0x05 0x030 1 43 --- Highest Average Short Term Temperature
|
||||
@@ -347,8 +347,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 419 --- Number of Hardware Resets
|
||||
0x06 0x010 4 273 --- Number of ASR Events
|
||||
0x06 0x008 4 423 --- Number of Hardware Resets
|
||||
0x06 0x010 4 276 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
@@ -366,13 +366,13 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 30 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 31 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 34 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 35 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 12457870 Vendor specific
|
||||
0x8000 4 14191072 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Mon Dec 19 16:53:51 2022 AEDT
|
||||
Local Time is: Tue Dec 27 07:20:10 2022 AEDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 186 163 021 - 1675
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2132
|
||||
3 Spin_Up_Time POS--K 187 163 021 - 1641
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2138
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 032 032 000 - 50063
|
||||
9 Power_On_Hours -O--CK 032 032 000 - 50211
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 198
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 204
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 39
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1678734
|
||||
194 Temperature_Celsius -O---K 118 100 000 - 29
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1685938
|
||||
194 Temperature_Celsius -O---K 119 100 000 - 28
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -146,9 +146,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/30 Celsius
|
||||
Lifetime Min/Max Temperature: 28/47 Celsius
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/30 Celsius
|
||||
Lifetime Min/Max Temperature: 25/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -159,7 +159,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (72)
|
||||
Temperature History Size (Index): 128 (4)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -178,7 +178,7 @@ ID Size Value Description
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 7814 Vendor specific
|
||||
0x8000 4 48895 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p20-HBSD amd64] (local build)
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.1-RELEASE-p21-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -12,7 +12,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon Sep 27 16:31:17 2021 CEST
|
||||
Local Time is: Mon Jan 10 09:41:15 2022 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -63,18 +63,18 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 151 146 021 - 1408
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2860
|
||||
3 Spin_Up_Time POS--K 155 146 021 - 1233
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2868
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 9106
|
||||
9 Power_On_Hours -O--CK 087 087 000 - 9913
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2853
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2861
|
||||
191 G-Sense_Error_Rate -O--CK 073 073 000 - 27
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 47
|
||||
193 Load_Cycle_Count -O--CK 082 082 000 - 354151
|
||||
194 Temperature_Celsius -O---K 098 096 000 - 45
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 55
|
||||
193 Load_Cycle_Count -O--CK 082 082 000 - 354171
|
||||
194 Temperature_Celsius -O---K 107 096 000 - 36
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -128,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 45 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/47 Celsius
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/37 Celsius
|
||||
Lifetime Min/Max Temperature: 22/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (26)
|
||||
Temperature History Size (Index): 128 (97)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -159,10 +159,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 20 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 962377 Vendor specific
|
||||
0x8000 4 231308 Vendor specific
|
||||
|
||||
|
Reference in New Issue
Block a user