1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 1329, modified: 0)

This commit is contained in:
Andrey Ponomarenko
2023-05-01 22:53:35 +03:00
parent 52e1a865b7
commit 6760e6c317
1329 changed files with 215727 additions and 0 deletions

View File

@@ -0,0 +1,303 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Maxtor DiamondMax 10 (ATA/133 and SATA/150)
Device Model: Maxtor 6L080P0
Serial Number: --
Firmware Version: BAJ41G20
User Capacity: 81,964,302,336 bytes [81.9 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 T13/1532D revision 0
Local Time is: Sun Mar 12 09:25:24 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 841) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 37) minutes.
SCT capabilities: (0x0021) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
3 Spin_Up_Time POS--K 227 227 063 - 9186
4 Start_Stop_Count -O--CK 249 249 000 - 8384
5 Reallocated_Sector_Ct PO--CK 253 253 063 - 3
6 Read_Channel_Margin P----- 253 253 100 - 0
7 Seek_Error_Rate -O-R-- 253 241 000 - 0
8 Seek_Time_Performance POS--K 248 235 187 - 40406
9 Power_On_Minutes -O--CK 178 178 000 - 1043h+10m
10 Spin_Retry_Count PO-R-K 253 252 157 - 0
11 Calibration_Retry_Count PO-R-K 253 252 223 - 0
12 Power_Cycle_Count -O--CK 230 230 000 - 9228
192 Power-Off_Retract_Count -O--CK 253 253 000 - 0
193 Load_Cycle_Count -O--CK 253 253 000 - 0
194 Temperature_Celsius -O--CK 043 253 000 - 50
195 Hardware_ECC_Recovered -O-R-- 253 252 000 - 631
196 Reallocated_Event_Count ---R-- 253 253 000 - 0
197 Current_Pending_Sector ---R-- 253 253 000 - 0
198 Offline_Uncorrectable ---R-- 253 253 000 - 0
199 UDMA_CRC_Error_Count ---R-- 199 199 000 - 0
200 Multi_Zone_Error_Rate -O-R-- 253 252 000 - 0
201 Soft_Read_Error_Rate -O-R-- 253 252 000 - 0
202 Data_Address_Mark_Errs -O-R-- 253 252 000 - 0
203 Run_Out_Cancel PO-R-- 253 252 180 - 0
204 Soft_ECC_Correction -O-R-- 253 252 000 - 0
205 Thermal_Asperity_Rate -O-R-- 253 252 000 - 0
207 Spin_High_Current -O-R-K 253 252 000 - 0
208 Spin_Buzz -O-R-K 253 252 000 - 0
209 Offline_Seek_Performnce --S--K 240 240 000 - 164
210 Unknown_Attribute -O--CK 253 252 000 - 0
211 Unknown_Attribute -O--CK 253 252 000 - 0
212 Unknown_Attribute -O--CK 253 252 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 1 Comprehensive SMART error log
0x03 GPL,SL R/O 4 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
SMART Extended Comprehensive Error Log Version: 1 (4 sectors)
Device Error Count: 1331 (device log contains only the most recent 16 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1331 [2] occurred at disk power-on lifetime: 12080 hours (503 days + 8 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 02 00 00 00 60 0c e7 40 00 Error: UNC 2 sectors at LBA = 0x00600ce7 = 6294759
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 02 00 00 00 60 0c e7 40 00 02:24:35.895 READ DMA
c8 00 00 00 08 00 00 00 00 07 9f 40 00 02:24:35.895 READ DMA
ca 00 00 00 08 00 00 00 00 07 9f 40 00 02:24:35.895 WRITE DMA
c8 00 00 00 08 00 00 00 00 07 9f 40 00 02:24:35.895 READ DMA
40 00 00 00 08 00 00 00 00 07 9f 40 00 02:24:35.876 READ VERIFY SECTOR(S)
Error 1330 [1] occurred at disk power-on lifetime: 12080 hours (503 days + 8 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 00 60 0c e7 40 00 Error: UNC 8 sectors at LBA = 0x00600ce7 = 6294759
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 08 00 00 00 60 0c e7 40 00 02:24:22.814 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 02:24:22.711 READ DMA
c8 00 00 00 08 00 00 00 60 0c e7 40 00 02:24:21.264 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 02:24:21.181 READ DMA
c8 00 00 00 08 00 00 00 60 0c e7 40 00 02:24:19.731 READ DMA
Error 1329 [0] occurred at disk power-on lifetime: 12080 hours (503 days + 8 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 00 60 0c e7 40 00 Error: UNC 8 sectors at LBA = 0x00600ce7 = 6294759
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 08 00 00 00 60 0c e7 40 00 02:24:21.264 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 02:24:21.181 READ DMA
c8 00 00 00 08 00 00 00 60 0c e7 40 00 02:24:19.731 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 02:24:19.648 READ DMA
c8 00 00 00 08 00 00 00 60 0c e7 40 00 02:24:18.209 READ DMA
Error 1328 [15] occurred at disk power-on lifetime: 12080 hours (503 days + 8 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 00 60 0c e7 40 00 Error: UNC 8 sectors at LBA = 0x00600ce7 = 6294759
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 08 00 00 00 60 0c e7 40 00 02:23:09.412 READ DMA
c8 00 00 00 08 00 00 00 60 56 67 40 00 02:23:09.410 READ DMA
c8 00 00 00 08 00 00 00 60 55 d7 40 00 02:23:09.410 READ DMA
c8 00 00 00 08 00 00 00 60 55 cf 40 00 02:23:09.403 READ DMA
c8 00 00 00 08 00 00 00 60 1d d7 40 00 02:23:09.403 READ DMA
Error 1327 [14] occurred at disk power-on lifetime: 12080 hours (503 days + 8 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 02 00 00 00 60 0c e7 40 00 Error: UNC 2 sectors at LBA = 0x00600ce7 = 6294759
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 02 00 00 00 60 0c e7 40 00 02:24:35.895 READ DMA
c8 00 00 00 08 00 00 00 00 07 9f 40 00 02:24:35.895 READ DMA
ca 00 00 00 08 00 00 00 00 07 9f 40 00 02:24:35.895 WRITE DMA
c8 00 00 00 08 00 00 00 00 07 9f 40 00 02:24:35.895 READ DMA
40 00 00 00 08 00 00 00 00 07 9f 40 00 02:24:35.876 READ VERIFY SECTOR(S)
Error 1326 [13] occurred at disk power-on lifetime: 12080 hours (503 days + 8 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 00 60 0c e7 40 00 Error: UNC 8 sectors at LBA = 0x00600ce7 = 6294759
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 08 00 00 00 60 0c e7 40 00 02:24:22.814 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 02:24:22.711 READ DMA
c8 00 00 00 08 00 00 00 60 0c e7 40 00 02:24:21.264 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 02:24:21.181 READ DMA
c8 00 00 00 08 00 00 00 60 0c e7 40 00 02:24:19.731 READ DMA
Error 1325 [12] occurred at disk power-on lifetime: 12080 hours (503 days + 8 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 00 60 0c e7 40 00 Error: UNC 8 sectors at LBA = 0x00600ce7 = 6294759
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 08 00 00 00 60 0c e7 40 00 02:24:21.264 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 02:24:21.181 READ DMA
c8 00 00 00 08 00 00 00 60 0c e7 40 00 02:24:19.731 READ DMA
c8 00 00 00 01 00 00 00 00 00 00 40 00 02:24:19.648 READ DMA
c8 00 00 00 08 00 00 00 60 0c e7 40 00 02:24:18.209 READ DMA
Error 1324 [11] occurred at disk power-on lifetime: 12080 hours (503 days + 8 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 00 60 0c e7 40 00 Error: UNC 8 sectors at LBA = 0x00600ce7 = 6294759
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 08 00 00 00 60 0c e7 40 00 02:23:09.412 READ DMA
c8 00 00 00 08 00 00 00 60 56 67 40 00 02:23:09.410 READ DMA
c8 00 00 00 08 00 00 00 60 55 d7 40 00 02:23:09.410 READ DMA
c8 00 00 00 08 00 00 00 60 55 cf 40 00 02:23:09.403 READ DMA
c8 00 00 00 08 00 00 00 60 1d d7 40 00 02:23:09.403 READ DMA
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 50 Celsius
Power Cycle Min/Max Temperature: --/50 Celsius
Lifetime Min/Max Temperature: --/62 Celsius
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: 0/71 Celsius
Temperature History Size (Index): 478 (477)
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported

View File

@@ -0,0 +1,151 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Maxtor DiamondMax 10 (SATA/300)
Device Model: Maxtor 6V080E0
Serial Number: --
Firmware Version: VA111680
User Capacity: 80,026,361,856 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 T13/1532D revision 0
Local Time is: Tue Mar 14 10:23:02 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Unavailable
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 19) The self-test routine was aborted by
the host.
Total time to complete Offline
data collection: ( 901) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 34) minutes.
SCT capabilities: (0x0021) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 32
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
3 Spin_Up_Time POS--K 224 224 063 - 7229
4 Start_Stop_Count -O--CK 253 253 000 - 763
5 Reallocated_Sector_Ct PO--CK 253 253 063 - 0
7 Seek_Error_Rate -O-R-- 253 252 000 - 0
8 Seek_Time_Performance POS--K 244 238 187 - 43354
9 Power_On_Hours -O--CK 243 243 000 - 3712
10 Spin_Retry_Count PO-R-K 253 252 157 - 0
11 Calibration_Retry_Count PO-R-K 253 252 223 - 0
12 Power_Cycle_Count -O--CK 252 252 000 - 766
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 077 058 000 - 23 (Min/Max 17/23)
192 Power-Off_Retract_Count -O--CK 253 253 000 - 0
193 Load_Cycle_Count -O--CK 253 253 000 - 0
194 Temperature_Celsius -O--CK 031 253 000 - 23
195 Hardware_ECC_Recovered -O-R-- 253 252 000 - 1178
196 Reallocated_Event_Count ---R-- 253 253 000 - 0
197 Current_Pending_Sector ---R-- 253 253 000 - 0
198 Offline_Uncorrectable ---R-- 253 253 000 - 0
199 UDMA_CRC_Error_Count ---R-- 199 199 000 - 0
200 Multi_Zone_Error_Rate -O-R-- 253 252 000 - 0
201 Soft_Read_Error_Rate -O-R-- 253 252 000 - 2
202 Data_Address_Mark_Errs -O-R-- 253 252 000 - 0
203 Run_Out_Cancel PO-R-- 253 252 180 - 0
204 Soft_ECC_Correction -O-R-- 253 252 000 - 0
205 Thermal_Asperity_Rate -O-R-- 253 252 000 - 0
207 Spin_High_Current -O-R-K 253 252 000 - 0
208 Spin_Buzz -O-R-K 253 252 000 - 0
210 Unknown_Attribute -O--CK 253 252 000 - 0
211 Unknown_Attribute -O--CK 253 252 000 - 0
212 Unknown_Attribute -O--CK 253 252 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 1 Comprehensive SMART error log
0x03 GPL,SL R/O 4 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
SMART Extended Comprehensive Error Log Version: 1 (4 sectors)
No Errors Logged
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Aborted by host 30% 1 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 23 Celsius
Power Cycle Min/Max Temperature: --/23 Celsius
Lifetime Min/Max Temperature: --/54 Celsius
SCT Temperature History Version: 2
Temperature Sampling Period: 5 minutes
Temperature Logging Interval: 5 minutes
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: 0/60 Celsius
Temperature History Size (Index): 478 (477)
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported

View File

@@ -0,0 +1,233 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Maxtor DiamondMax Plus 9
Device Model: Maxtor 6Y080M0
Serial Number: --
Firmware Version: YAR51HW0
User Capacity: 81,963,220,480 bytes [81.9 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 T13/1532D revision 0
Local Time is: Mon Mar 13 08:36:00 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 254 (maximum performance), recommended: 192
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x85) Offline data collection activity
was aborted by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 241) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 37) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
3 Spin_Up_Time POS--K 226 225 063 - 10797
4 Start_Stop_Count -O--CK 253 253 000 - 1745
5 Reallocated_Sector_Ct PO--CK 253 253 063 - 0
6 Read_Channel_Margin P----- 253 253 100 - 0
7 Seek_Error_Rate -O-R-- 253 249 000 - 0
8 Seek_Time_Performance POS--K 251 242 187 - 41119
9 Power_On_Minutes -O--CK 208 208 000 - 342h+37m
10 Spin_Retry_Count PO-R-K 253 252 157 - 0
11 Calibration_Retry_Count PO-R-K 253 252 223 - 0
12 Power_Cycle_Count -O--CK 249 249 000 - 1762
192 Power-Off_Retract_Count -O--CK 253 253 000 - 0
193 Load_Cycle_Count -O--CK 253 253 000 - 0
194 Temperature_Celsius -O--CK 253 253 000 - 29
195 Hardware_ECC_Recovered -O-R-- 253 252 000 - 2769
196 Reallocated_Event_Count ---R-- 253 253 000 - 0
197 Current_Pending_Sector ---R-- 253 253 000 - 0
198 Offline_Uncorrectable ---R-- 253 253 000 - 0
199 UDMA_CRC_Error_Count ---R-- 196 182 000 - 17
200 Multi_Zone_Error_Rate -O-R-- 253 252 000 - 0
201 Soft_Read_Error_Rate -O-R-- 253 251 000 - 10
202 Data_Address_Mark_Errs -O-R-- 253 250 000 - 0
203 Run_Out_Cancel PO-R-- 253 252 180 - 4
204 Soft_ECC_Correction -O-R-- 253 252 000 - 0
205 Thermal_Asperity_Rate -O-R-- 253 252 000 - 0
207 Spin_High_Current -O-R-K 253 252 000 - 0
208 Spin_Buzz -O-R-K 253 252 000 - 0
209 Offline_Seek_Performnce --S--K 192 192 000 - 0
99 Unknown_Attribute --S--- 253 253 000 - 0
100 Unknown_Attribute --S--- 253 253 000 - 0
101 Unknown_Attribute --S--- 253 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
Read SMART Log Directory failed: Input/output error
General Purpose Log Directory not supported
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
Warning: ATA error count 22 inconsistent with error log pointer 5
ATA Error Count: 22 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 22 occurred at disk power-on lifetime: 14574 hours (607 days + 6 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 00 a1 e6 03 e0 Error: ICRC, ABRT at LBA = 0x0003e6a1 = 255649
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 d8 08 a1 e6 03 e0 00 00:03:38.432 READ DMA
c8 d8 09 b9 89 01 e0 00 00:03:38.432 READ DMA
c8 d8 08 61 83 01 e0 00 00:03:38.416 READ DMA
c8 d8 02 f1 44 01 e0 00 00:03:38.416 READ DMA
c8 d8 80 d9 fa fc e1 00 00:03:38.416 READ DMA
Error 21 occurred at disk power-on lifetime: 14552 hours (606 days + 8 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 00 3a 7b 27 e2 Error: ICRC, ABRT at LBA = 0x02277b3a = 36141882
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 40 3a 7b 27 e2 00 00:18:39.472 READ DMA
c8 00 40 c2 f0 26 e2 00 00:18:39.424 READ DMA
c6 00 10 00 00 00 a0 00 00:18:38.688 SET MULTIPLE MODE
ef 03 46 00 00 00 a0 00 00:18:38.672 SET FEATURES [Set transfer mode]
ef 03 0c 00 00 00 a0 00 00:18:38.656 SET FEATURES [Set transfer mode]
Error 20 occurred at disk power-on lifetime: 14552 hours (606 days + 8 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 00 c2 f0 26 e2 Error: ICRC, ABRT at LBA = 0x0226f0c2 = 36106434
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 40 c2 f0 26 e2 00 00:18:39.424 READ DMA
c6 00 10 00 00 00 a0 00 00:18:38.688 SET MULTIPLE MODE
ef 03 46 00 00 00 a0 00 00:18:38.672 SET FEATURES [Set transfer mode]
ef 03 0c 00 00 00 a0 00 00:18:38.656 SET FEATURES [Set transfer mode]
c8 00 08 20 4c f5 e1 04 00:18:38.656 READ DMA
Error 19 occurred at disk power-on lifetime: 14552 hours (606 days + 8 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 00 78 3b 06 e1 Error: ICRC, ABRT at LBA = 0x01063b78 = 17185656
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 00 78 3b 06 e1 00 00:16:58.144 READ DMA
c8 00 08 80 39 06 e1 00 00:16:58.144 READ DMA
c8 00 40 32 3b b9 e0 00 00:16:58.096 READ DMA
c8 00 40 f2 e2 a3 e0 00 00:16:58.032 READ DMA
c8 00 26 7a 6c 8e e0 00 00:16:57.968 READ DMA
Error 18 occurred at disk power-on lifetime: 14552 hours (606 days + 8 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 00 32 3b b9 e0 Error: ICRC, ABRT at LBA = 0x00b93b32 = 12139314
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 40 32 3b b9 e0 00 00:16:58.096 READ DMA
c8 00 40 f2 e2 a3 e0 00 00:16:58.032 READ DMA
c8 00 26 7a 6c 8e e0 00 00:16:57.968 READ DMA
c8 00 08 60 49 63 e0 00 00:16:57.968 READ DMA
ca 00 98 d0 ab 5f e0 00 00:16:57.952 WRITE DMA
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 14110 -
# 2 Extended offline Interrupted (host reset) 40% 14105 -
# 3 Short offline Completed without error 00% 14098 -
# 4 Short offline Completed without error 00% 14095 -
# 5 Short offline Completed without error 00% 11302 -
# 6 Short offline Completed without error 00% 11196 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported

View File

@@ -0,0 +1,138 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: MAXTOR STM3160815AS
Serial Number: --
Firmware Version: 4.AAB
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Fri Mar 17 01:03:21 2023 +05
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 54) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 253 006 - 0
3 Spin_Up_Time PO---- 098 097 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 801
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 082 060 030 - 183267106
9 Power_On_Hours -O--CK 055 055 000 - 40173
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 097 097 020 - 3681
187 Reported_Uncorrect -O--CK 100 100 000 - 0
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 057 050 045 - 43 (Min/Max 42/45)
194 Temperature_Celsius -O---K 043 050 000 - 43 (0 16 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 086 071 000 - 236175936
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
0xff GPL - 23040 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS

View File

@@ -0,0 +1,289 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Maxtor DiamondMax 21
Device Model: MAXTOR STM3320620AS
Serial Number: --
Firmware Version: 3.AAE
User Capacity: 320,071,851,520 bytes [320 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Wed Mar 22 00:09:51 2023 EET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 115) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 119 087 006 - 222362460
3 Spin_Up_Time PO---- 097 095 000 - 0
4 Start_Stop_Count -O--CK 093 093 020 - 7631
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 078 060 030 - 26194438778
9 Power_On_Hours -O--CK 089 089 000 - 9838
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 093 093 020 - 7436
187 Reported_Uncorrect -O--CK 100 100 000 - 0
189 High_Fly_Writes -O-RCK 096 096 000 - 4
190 Airflow_Temperature_Cel -O---K 056 050 045 - 44 (Min/Max 44/44)
194 Temperature_Celsius -O---K 044 050 000 - 44 (0 15 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 065 057 000 - 56759222
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 1
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
0xff GPL - 23040 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 194 (device log contains only the most recent 20 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 194 [13] occurred at disk power-on lifetime: 2859 hours (119 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 00 00 00 00 e5 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 25 e2 00 42 6e e5 00 02:27:24.595 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 25 e2 00 42 6e e0 00 02:27:24.532 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 00 00 00 25 e2 00 42 6e e5 00 02:27:22.450 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 01 01 00 25 e2 00 42 6e e0 00 02:27:22.391 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 01 01 00 25 e2 00 42 6e e5 00 02:27:22.175 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 193 [12] occurred at disk power-on lifetime: 2859 hours (119 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 00 00 00 00 e5 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 25 e2 00 42 6e e5 00 02:27:18.960 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 25 e2 00 42 6e e0 00 02:27:18.960 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 00 00 00 25 e2 00 42 6e e5 00 02:27:22.450 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 01 00 25 ea 00 42 af e0 00 02:27:22.391 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
29 00 00 00 01 00 25 ea 00 42 af e0 00 02:27:22.175 READ MULTIPLE EXT
Error 192 [11] occurred at disk power-on lifetime: 2866 hours (119 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 00 00 00 00 e5 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 25 e2 00 42 6e e5 00 03:23:44.066 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 25 e2 00 42 6e e0 00 03:23:43.927 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 00 00 00 25 e2 00 42 6e e5 00 03:23:43.810 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 01 01 00 25 e2 00 42 6e e0 00 03:23:43.749 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 01 01 00 25 e2 00 42 6e e5 00 03:23:41.398 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 191 [10] occurred at disk power-on lifetime: 2866 hours (119 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 00 00 00 00 e5 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 25 e2 00 42 6e e5 00 03:23:44.066 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 25 e2 00 42 6e e0 00 03:23:43.927 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 00 00 00 25 e2 00 42 6e e5 00 03:23:43.810 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 01 00 25 ea 00 42 af e0 00 03:23:43.749 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
29 00 00 00 01 00 25 ea 00 42 af e0 00 03:23:41.398 READ MULTIPLE EXT
Error 190 [9] occurred at disk power-on lifetime: 2859 hours (119 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 00 00 00 00 e5 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 25 e2 00 42 6e e5 00 02:27:24.595 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 25 e2 00 42 6e e0 00 02:27:24.532 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 00 00 00 25 e2 00 42 6e e5 00 02:27:22.450 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 01 01 00 25 e2 00 42 6e e0 00 02:27:22.391 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 01 01 00 25 e2 00 42 6e e5 00 02:27:22.175 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 189 [8] occurred at disk power-on lifetime: 2859 hours (119 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 00 00 00 00 e5 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 25 e2 00 42 6e e5 00 02:27:18.960 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 25 e2 00 42 6e e0 00 02:27:18.960 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 00 00 00 25 e2 00 42 6e e5 00 02:27:22.450 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 01 00 25 ea 00 42 af e0 00 02:27:22.391 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
29 00 00 00 01 00 25 ea 00 42 af e0 00 02:27:22.175 READ MULTIPLE EXT
Error 188 [7] occurred at disk power-on lifetime: 2866 hours (119 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 00 00 00 00 e5 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 25 e2 00 42 6e e5 00 03:23:44.066 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 25 e2 00 42 6e e0 00 03:23:43.927 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 00 00 00 25 e2 00 42 6e e5 00 03:23:43.810 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 01 01 00 25 e2 00 42 6e e0 00 03:23:43.749 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 01 01 00 25 e2 00 42 6e e5 00 03:23:41.398 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 187 [6] occurred at disk power-on lifetime: 2866 hours (119 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 00 00 00 00 e5 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 25 e2 00 42 6e e5 00 03:23:44.066 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 25 e2 00 42 6e e0 00 03:23:43.927 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 00 00 00 25 e2 00 42 6e e5 00 03:23:43.810 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 01 00 25 ea 00 42 af e0 00 03:23:43.749 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
29 00 00 00 01 00 25 ea 00 42 af e0 00 03:23:41.398 READ MULTIPLE EXT
SMART Extended Self-test Log Version: 1 (1 sectors)
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 19 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS

View File

@@ -0,0 +1,148 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Maxtor DiamondMax 21
Device Model: MAXTOR STM3320820AS
Serial Number: --
Firmware Version: 3.AAE
User Capacity: 320,072,933,376 bytes [320 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Wed Apr 5 15:40:32 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 115) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 119 088 006 - 203174574
3 Spin_Up_Time PO---- 097 095 000 - 0
4 Start_Stop_Count -O--CK 095 095 020 - 5650
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 081 060 030 - 156498875
9 Power_On_Hours -O--CK 071 071 000 - 26248
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 095 095 020 - 5145
187 Reported_Uncorrect -O--CK 100 100 000 - 0
189 High_Fly_Writes -O-RCK 098 098 000 - 2
190 Airflow_Temperature_Cel -O---K 059 047 045 - 41 (Min/Max 24/41)
194 Temperature_Celsius -O---K 041 053 000 - 41 (0 14 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 068 062 000 - 23297496
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
0xff GPL - 23040 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 23685 -
# 2 Short offline Completed without error 00% 22033 -
# 3 Short offline Completed without error 00% 19122 -
# 4 Short offline Completed without error 00% 13390 -
# 5 Short offline Aborted by host 60% 13304 -
# 6 Extended offline Aborted by host 90% 13304 -
# 7 Short offline Completed without error 00% 10873 -
# 8 Short offline Completed without error 00% 5504 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 29 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS