smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p6 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.12
Device Model: ST31000524AS
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: HP63
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Tue Mar 7 00:30:02 2023 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unknown
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 600) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 167) minutes.
SCT capabilities: (0x103b) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 116 099 006 - 108711115
3 Spin_Up_Time PO---K 100 100 000 - 0
4 Start_Stop_Count -O--CK 094 094 020 - 6529
5 Reallocated_Sector_Ct PO--CK 086 086 036 - 611
7 Seek_Error_Rate POSR-K 089 060 030 - 882174471
9 Power_On_Hours -O--CK 044 044 000 - 49071
10 Spin_Retry_Count PO--CK 100 100 097 - 0
12 Power_Cycle_Count -O--CK 094 094 020 - 6528
180 Unknown_HDD_Attribute PO-R-K 100 100 000 - 1282144130
183 Runtime_Bad_Block -O--CK 097 097 000 - 3
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 089 089 000 - 11
188 Command_Timeout -O--CK 100 097 000 - 8590196741
189 High_Fly_Writes -O-RCK 097 097 000 - 3
190 Airflow_Temperature_Cel -O---K 074 062 045 - 26 (Min/Max 21/28)
194 Temperature_Celsius -O---K 026 040 000 - 26 (0 10 0 0 0)
195 Hardware_ECC_Recovered -O-RCK 029 020 000 - 108711115
196 Reallocated_Event_Count -O--CK 086 086 036 - 611
197 Current_Pending_Sector -O--CK 085 085 000 - 647
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL VS 2248 Device vendor specific log
0xa8 GPL,SL VS 129 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xb0 GPL VS 2928 Device vendor specific log
0xbd GPL VS 252 Device vendor specific log
0xbe-0xbf GPL VS 65535 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 3
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 3 [2] occurred at disk power-on lifetime: 48759 hours (2031 days + 15 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 3a 24 28 e8 00 00 Error: WP at LBA = 0x3a2428e8 = 975448296
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 00 00 08 00 00 3a 14 08 00 40 00 00:01:11.878 WRITE FPDMA QUEUED
60 00 00 00 08 00 00 3a 24 28 e8 40 00 00:01:11.878 READ FPDMA QUEUED
ec 00 00 00 00 00 00 00 00 00 00 a0 00 00:01:11.877 IDENTIFY DEVICE
ef 00 03 00 45 00 00 00 00 00 00 a0 00 00:01:11.876 SET FEATURES [Set transfer mode]
ec 00 00 00 00 00 00 00 00 00 00 a0 00 00:01:11.855 IDENTIFY DEVICE
Error 2 [1] occurred at disk power-on lifetime: 48759 hours (2031 days + 15 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 3a 24 28 e8 00 00 Error: UNC at LBA = 0x3a2428e8 = 975448296
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 3a 24 28 e8 40 00 00:01:09.039 READ FPDMA QUEUED
ec 00 00 00 00 00 00 00 00 00 00 a0 00 00:01:09.038 IDENTIFY DEVICE
ef 00 03 00 45 00 00 00 00 00 00 a0 00 00:01:09.037 SET FEATURES [Set transfer mode]
ec 00 00 00 00 00 00 00 00 00 00 a0 00 00:01:08.996 IDENTIFY DEVICE
47 00 00 00 01 00 00 00 00 00 10 a0 00 00:01:08.929 READ LOG DMA EXT
Error 1 [0] occurred at disk power-on lifetime: 48759 hours (2031 days + 15 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 3a 24 28 e8 00 00 Error: UNC at LBA = 0x3a2428e8 = 975448296
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 3a 24 24 20 40 00 00:01:06.157 READ FPDMA QUEUED
60 00 00 00 08 00 00 3a 24 23 d0 40 00 00:01:06.153 READ FPDMA QUEUED
60 00 00 00 20 00 00 3a 14 08 00 40 00 00:01:06.144 READ FPDMA QUEUED
60 00 00 00 08 00 00 3a 14 07 f8 40 00 00:01:06.114 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 10 2c b0 40 00 00:01:06.108 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Interrupted (host reset) 90% 8324 -
# 2 Short offline Interrupted (host reset) 90% 8322 -
# 3 Short offline Completed without error 00% 8007 -
# 4 Short offline Completed without error 00% 7853 -
# 5 Extended offline Interrupted (host reset) 90% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
Device State: Active (0)
Current Temperature: 26 Celsius
Power Cycle Min/Max Temperature: 21/28 Celsius
Lifetime Min/Max Temperature: 10/38 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 59 minutes
Min/Max recommended Temperature: 14/55 Celsius
Min/Max Temperature Limit: 10/60 Celsius
Temperature History Size (Index): 128 (64)
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 49 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS

View File

@@ -0,0 +1,168 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p10-HBSD amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.12
Device Model: ST31000524AS
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: HP64
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Sat Mar 18 15:30:11 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 609) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 174) minutes.
SCT capabilities: (0x103b) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 114 099 006 - 75569732
3 Spin_Up_Time PO---K 100 095 000 - 0
4 Start_Stop_Count -O--CK 095 095 020 - 5985
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 21
7 Seek_Error_Rate POSR-K 080 060 030 - 115862211
9 Power_On_Hours -O--CK 074 074 000 - 23457
10 Spin_Retry_Count PO--CK 100 100 097 - 0
12 Power_Cycle_Count -O--CK 095 095 020 - 5244
180 Unknown_HDD_Attribute PO-R-K 100 100 000 - 2143644894
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 100 000 - 6
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 058 043 045 Past 42 (Min/Max 29/44 #20)
194 Temperature_Celsius -O---K 042 057 000 - 42 (0 13 0 0 0)
195 Hardware_ECC_Recovered -O-RCK 018 018 000 - 75569732
196 Reallocated_Event_Count -O--CK 100 100 036 - 21
197 Current_Pending_Sector -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL VS 2248 Device vendor specific log
0xa8 GPL,SL VS 129 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xb0 GPL VS 2928 Device vendor specific log
0xbd GPL VS 252 Device vendor specific log
0xbe-0xbf GPL VS 65535 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Interrupted (host reset) 90% 1 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
Device State: Active (0)
Current Temperature: 42 Celsius
Power Cycle Min/Max Temperature: 29/44 Celsius
Lifetime Min/Max Temperature: 13/57 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 59 minutes
Min/Max recommended Temperature: 14/55 Celsius
Min/Max Temperature Limit: 10/60 Celsius
Temperature History Size (Index): 128 (83)
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 15 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS