smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p6 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Indilinx Barefoot_2/Everest/Martini based SSDs
|
||||
Device Model: OCZ VERTEX PLUS
|
||||
Serial Number: --
|
||||
Firmware Version: 3.50
|
||||
User Capacity: 120,034,123,776 bytes [120 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
Local Time is: Thu Mar 2 22:25:20 2023 EET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x1d) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Abort Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
No Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x00) Error logging NOT supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 0) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 0) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 18
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 005 000 000 - 5
|
||||
3 Spin_Up_Time ------ 100 100 000 - 0
|
||||
4 Start_Stop_Count ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 10935
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 193
|
||||
232 Lifetime_Writes ------ 100 100 000 - 94008
|
||||
233 Media_Wearout_Indicator ------ 100 000 000 - 100
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 77 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0xa0 GPL VS 4096 Device vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 18 (77 sectors)
|
||||
No Errors Logged
|
||||
|
||||
Warning! SMART Extended Self-test Log Structure error: invalid SMART checksum.
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
Selective Self-tests/Logging not supported
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
[Reserved: 0x00 0x00 0x41 0x00]
|
||||
ID Size Value Description
|
||||
0x8b18 14: Invalid entry
|
||||
|
Reference in New Issue