1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 0, modified: 424)

This commit is contained in:
Andrey Ponomarenko
2023-02-17 09:04:26 +03:00
parent 4aabefee83
commit 785ce3d324
424 changed files with 8726 additions and 8652 deletions

View File

@@ -1,5 +1,5 @@
smartctl 7.2 2020-12-30 r5155 [OpenBSD 7.1 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
smartctl 7.3 2022-02-28 r5338 [OpenBSD 7.1 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint M7E (AF)
@@ -11,10 +11,10 @@ User Capacity: 320,072,933,376 bytes [320 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Wed Feb 23 16:25:08 2022 CET
Local Time is: Fri Mar 18 11:47:58 2022 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
@@ -57,28 +57,28 @@ SCT capabilities: (0x003f) SCT Status supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always - 11
1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always - 19
2 Throughput_Performance 0x0026 252 252 000 Old_age Always - 0
3 Spin_Up_Time 0x0023 089 089 025 Pre-fail Always - 3409
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 650
3 Spin_Up_Time 0x0023 089 089 025 Pre-fail Always - 3402
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 796
5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0
8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 249
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 309
10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 620
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 619
191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always - 738
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 699
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 770
191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always - 895
192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0
194 Temperature_Celsius 0x0002 064 064 000 Old_age Always - 33 (Min/Max 12/38)
194 Temperature_Celsius 0x0002 064 064 000 Old_age Always - 32 (Min/Max 12/38)
195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always - 0
196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0
197 Current_Pending_Sector 0x0032 252 252 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0036 100 100 000 Old_age Always - 11
200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 32
223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 620
225 Load_Cycle_Count 0x0032 099 099 000 Old_age Always - 15796
200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 38
223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 699
225 Load_Cycle_Count 0x0032 099 099 000 Old_age Always - 19941
SMART Error Log Version: 1
No Errors Logged