mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 424)
This commit is contained in:
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p4 amd64] (local build)
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Nov 3 22:48:18 2021 GMT
|
||||
Local Time is: Fri May 20 01:55:25 2022 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,10 +65,10 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 2521
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 2665
|
||||
175 Program_Fail_Count_Chip -O--CK 100 100 010 - 0
|
||||
176 Erase_Fail_Count_Chip -O--CK 100 100 010 - 0
|
||||
177 Wear_Leveling_Count PO--C- 080 080 005 - 231
|
||||
177 Wear_Leveling_Count PO--C- 080 080 005 - 240
|
||||
178 Used_Rsvd_Blk_Cnt_Chip PO--C- 100 100 010 - 0
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
180 Unused_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 4423
|
||||
@@ -76,8 +76,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 64360164733
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 68857739666
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 67568298685
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 72790791846
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -107,24 +107,24 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 0 -
|
||||
# 1 Short offline Completed without error 00% 2 -
|
||||
# 2 Short offline Completed without error 00% 0 -
|
||||
# 3 Short offline Completed without error 00% 4 -
|
||||
# 4 Short offline Completed without error 00% 4 -
|
||||
# 5 Short offline Completed without error 00% 0 -
|
||||
# 6 Short offline Completed without error 00% 1 -
|
||||
# 7 Short offline Completed without error 00% 63 -
|
||||
# 8 Short offline Completed without error 00% 119 -
|
||||
# 9 Short offline Completed without error 00% 89 -
|
||||
#10 Short offline Completed without error 00% 88 -
|
||||
#11 Short offline Completed without error 00% 0 -
|
||||
#12 Short offline Completed without error 00% 0 -
|
||||
# 3 Short offline Completed without error 00% 0 -
|
||||
# 4 Short offline Completed without error 00% 0 -
|
||||
# 5 Short offline Completed without error 00% 4 -
|
||||
# 6 Short offline Completed without error 00% 4 -
|
||||
# 7 Short offline Completed without error 00% 0 -
|
||||
# 8 Short offline Completed without error 00% 1 -
|
||||
# 9 Short offline Completed without error 00% 63 -
|
||||
#10 Short offline Completed without error 00% 119 -
|
||||
#11 Short offline Completed without error 00% 89 -
|
||||
#12 Short offline Completed without error 00% 88 -
|
||||
#13 Short offline Completed without error 00% 0 -
|
||||
#14 Short offline Completed without error 00% 2 -
|
||||
#15 Short offline Completed without error 00% 72 -
|
||||
#16 Short offline Completed without error 00% 4 -
|
||||
#17 Short offline Completed without error 00% 0 -
|
||||
#18 Short offline Completed without error 00% 0 -
|
||||
#14 Short offline Completed without error 00% 0 -
|
||||
#15 Short offline Completed without error 00% 0 -
|
||||
#16 Short offline Completed without error 00% 2 -
|
||||
#17 Short offline Completed without error 00% 72 -
|
||||
#18 Short offline Completed without error 00% 4 -
|
||||
#19 Short offline Completed without error 00% 0 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
@@ -144,7 +144,7 @@ Device State: Active (0)
|
||||
Current Temperature: 40 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/ ? Celsius
|
||||
Lifetime Min/Max Temperature: ?/ ? Celsius
|
||||
Under/Over Temperature Limit Count: 0/79299
|
||||
Under/Over Temperature Limit Count: 0/80775
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
|
Reference in New Issue