@@ -13,7 +13,7 @@ Form Factor: 2.5 inches
Device is: Not in smartctl database 7.3/5319
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Sun Jun 11 21:52:04 2023 CEST
Local Time is: Sun Jun 25 17:27:52 2023 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -69,14 +69,14 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
8 Seek_Time_Performance P-S--- 100 100 040 - 0
9 Power_On_Hours -O--C- 061 061 000 - 17120
9 Power_On_Hours -O--C- 061 061 000 - 17452
10 Spin_Retry_Count PO--C- 100 100 060 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 2455
160 Unknown_Attribute -O--CK 100 100 000 - 0
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
192 Power-Off_Retract_Count -O--CK 100 100 000 - 8589934647
193 Load_Cycle_Count -O--C- 049 049 000 - 519255
194 Temperature_Celsius -O---- 120 120 000 - 50 (Min/Max 11/56)
194 Temperature_Celsius -O---- 117 117 000 - 51 (Min/Max 11/57)
195 Hardware_ECC_Recovered -O-R-- 100 100 000 - 0
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O---K 100 100 000 - 0
@@ -127,10 +127,10 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 50 Celsius
Power Cycle Min/Max Temperature: 43/56 Celsius
Lifetime Min/Max Temperature: 11/56 Celsius
Specified Max Operating Temperature: 35 Celsius
Current Temperature: 51 Celsius
Power Cycle Min/Max Temperature: 43/57 Celsius
Lifetime Min/Max Temperature: 11/57 Celsius
Specified Max Operating Temperature: 36 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
@@ -138,7 +138,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/65 Celsius
Temperature History Size (Index): 128 (65)
Temperature History Size (Index): 128 (121)
SCT Error Recovery Control: