smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.3-RC1 amd64] (local build)
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p5 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -13,7 +13,7 @@ Form Factor: 2.5 inches
Device is: Not in smartctl database 7.3/5528
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Sat Mar 2 07:09:42 2024 GMT
Local Time is: Sat Sep 28 13:20:55 2024 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -64,20 +64,20 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
2 Throughput_Performance P-S--- 100 100 040 - 0
3 Spin_Up_Time POS--- 212 212 033 - 2
4 Start_Stop_Count -O--C- 099 099 000 - 2153
3 Spin_Up_Time POS--- 180 180 033 - 2
4 Start_Stop_Count -O--C- 099 099 000 - 2291
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 8
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
8 Seek_Time_Performance P-S--- 100 100 040 - 0
9 Power_On_Hours -O--C- 091 091 000 - 4349
9 Power_On_Hours -O--C- 090 090 000 - 4730
10 Spin_Retry_Count PO--C- 100 100 060 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 1704
12 Power_Cycle_Count -O--CK 099 099 000 - 1842
160 Unknown_Attribute -O--CK 100 100 000 - 0
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
192 Power-Off_Retract_Count -O--CK 099 099 000 - 605590388809
193 Load_Cycle_Count -O--C- 076 076 000 - 245521
194 Temperature_Celsius -O---- 214 214 000 - 28 (Min/Max 5/54)
195 Hardware_ECC_Recovered -O-R-- 068 068 000 - 33554664
192 Power-Off_Retract_Count -O--CK 099 099 000 - 605590388828
193 Load_Cycle_Count -O--C- 074 074 000 - 267271
194 Temperature_Celsius -O---- 230 230 000 - 26 (Min/Max 5/54)
195 Hardware_ECC_Recovered -O-R-- 074 074 000 - 16777408
196 Reallocated_Event_Count -O--CK 100 100 000 - 8
197 Current_Pending_Sector -O---K 100 100 000 - 0
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
@@ -127,8 +127,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 28 Celsius
Power Cycle Min/Max Temperature: 15/36 Celsius
Current Temperature: 26 Celsius
Power Cycle Min/Max Temperature: 16/26 Celsius
Lifetime Min/Max Temperature: 5/54 Celsius
Specified Max Operating Temperature: 36 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -138,7 +138,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/65 Celsius
Temperature History Size (Index): 128 (76)
Temperature History Size (Index): 128 (44)
SCT Error Recovery Control:
Read: Disabled