1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 35, modified: 3308)

This commit is contained in:
Andrey Ponomarenko
2025-01-05 02:37:11 +03:00
parent f68c38aa35
commit 8c515ea896
3343 changed files with 73552 additions and 65384 deletions

View File

@@ -1,5 +1,5 @@
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.1-RELEASE-p22-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint P80 SD
@@ -8,9 +8,9 @@ Serial Number: --
Firmware Version: ZH100-47
User Capacity: 80,026,361,856 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
Device is: In smartctl database 7.3/5528
ATA Version is: ATA/ATAPI-7 T13/1532D revision 4a
Local Time is: Sun May 5 20:02:36 2024 CEST
Local Time is: Thu May 30 21:46:51 2024 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 254 (maximum performance), recommended: 254
@@ -65,14 +65,14 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 253 253 010 - 0
7 Seek_Error_Rate POSR-- 253 253 051 - 0
8 Seek_Time_Performance P-S--K 253 253 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 28183
9 Power_On_Hours -O--CK 100 100 000 - 28787
10 Spin_Retry_Count PO--CK 253 253 051 - 0
11 Calibration_Retry_Count -O--C- 253 253 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 815
187 Reported_Uncorrect -O--CK 253 253 000 - 0
190 Airflow_Temperature_Cel -O---K 076 064 000 - 54
194 Temperature_Celsius -O---K 076 064 000 - 54
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 59920442
190 Airflow_Temperature_Cel -O---K 073 064 000 - 55
194 Temperature_Celsius -O---K 073 064 000 - 55
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 80116222
196 Reallocated_Event_Count -O--CK 253 253 000 - 0
197 Current_Pending_Sector -O--C- 253 253 000 - 0
198 Offline_Uncorrectable ----CK 253 253 000 - 0
@@ -101,6 +101,8 @@ Address Access R/W Size Description
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Invalid Error Log index = 0x0800 (reserved = 0x00)
Device Error Count: 200 (possibly also invalid)
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
@@ -123,8 +125,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 54 Celsius
Power Cycle Min/Max Temperature: --/55 Celsius
Current Temperature: 55 Celsius
Power Cycle Min/Max Temperature: --/57 Celsius
Lifetime Min/Max Temperature: --/60 Celsius
SCT Temperature History Version: 2
@@ -132,7 +134,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 10/55 Celsius
Min/Max Temperature Limit: 5/60 Celsius
Temperature History Size (Index): 128 (50)
Temperature History Size (Index): 128 (77)
SCT Error Recovery Control:
Read: Disabled
@@ -145,7 +147,7 @@ Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
0x000a 2 84 Device-to-host register FISes sent due to a COMRESET
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
0x000b 2 0 CRC errors within host-to-device FIS