smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.2-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SAMSUNG SpinPoint S250
|
||||
@@ -9,9 +9,9 @@ LU WWN Device Id: 5 0000f0 ...
|
||||
Firmware Version: FH100-06
|
||||
User Capacity: 250,059,350,016 bytes [250 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA/ATAPI-7, ATA8-ACS T13/1699-D revision 3b
|
||||
Local Time is: Fri Mar 11 12:14:20 2022 CET
|
||||
Local Time is: Mon Jun 19 13:32:07 2023 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 254
|
||||
@@ -62,21 +62,21 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 253 100 051 - 0
|
||||
3 Spin_Up_Time POS--- 253 253 025 - 4352
|
||||
4 Start_Stop_Count -O--CK 089 089 000 - 11434
|
||||
4 Start_Stop_Count -O--CK 088 088 000 - 12873
|
||||
5 Reallocated_Sector_Ct PO--CK 253 253 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 253 253 051 - 0
|
||||
8 Seek_Time_Performance P-S--K 253 253 015 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 26020
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 27906
|
||||
10 Spin_Retry_Count PO--CK 253 253 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 253 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 094 094 000 - 6143
|
||||
13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 2364
|
||||
12 Power_Cycle_Count -O--CK 094 094 000 - 6940
|
||||
13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 2360
|
||||
184 End-to-End_Error PO--CK 253 253 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 253 253 000 - 0
|
||||
188 Command_Timeout -O--CK 253 253 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 145 109 000 - 31 (Min/Max 4/43)
|
||||
194 Temperature_Celsius -O---K 142 106 000 - 32 (Min/Max 4/44)
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 2364
|
||||
190 Airflow_Temperature_Cel -O---K 124 109 000 - 38 (Min/Max 4/43)
|
||||
194 Temperature_Celsius -O---K 121 106 000 - 39 (Min/Max 4/44)
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 2360
|
||||
196 Reallocated_Event_Count -O--CK 253 253 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 253 253 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 253 253 000 - 0
|
||||
@@ -128,9 +128,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/32 Celsius
|
||||
Lifetime Min/Max Temperature: 5/44 Celsius
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 18/39 Celsius
|
||||
Lifetime Min/Max Temperature: 5/45 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -138,7 +138,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: -4/72 Celsius
|
||||
Min/Max Temperature Limit: -9/77 Celsius
|
||||
Temperature History Size (Index): 128 (123)
|
||||
Temperature History Size (Index): 128 (95)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -150,16 +150,16 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 8 Command failed due to ICRC error
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 8 Device-to-host non-data FIS retries
|
||||
0x0009 2 9 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 15 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|