1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 35, modified: 3308)

This commit is contained in:
Andrey Ponomarenko
2025-01-05 02:37:11 +03:00
parent f68c38aa35
commit 8c515ea896
3343 changed files with 73552 additions and 65384 deletions

View File

@@ -1,5 +1,5 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint P80
@@ -8,9 +8,9 @@ Serial Number: --
Firmware Version: SU100-32
User Capacity: 80,026,361,856 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 T13/1532D revision 0
Local Time is: Wed Mar 9 05:30:49 2022 EST
Local Time is: Mon Jul 3 08:51:31 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -55,17 +55,17 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0
3 Spin_Up_Time POS--- 100 100 025 - 4160
4 Start_Stop_Count -O--CK 100 100 000 - 638
3 Spin_Up_Time POS--- 100 100 025 - 4032
4 Start_Stop_Count -O--CK 100 100 000 - 821
5 Reallocated_Sector_Ct PO--CK 100 100 011 - 0
7 Seek_Error_Rate POSR-- 100 100 051 - 0
8 Seek_Time_Performance P-S--K 100 100 015 - 0
9 Power_On_Half_Minutes -O--CK 099 099 000 - 5623h+07m
9 Power_On_Half_Minutes -O--CK 099 099 000 - 5661h+03m
10 Spin_Retry_Count PO--CK 100 100 051 - 0
11 Calibration_Retry_Count -O--C- 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 368
12 Power_Cycle_Count -O--CK 100 100 000 - 508
194 Temperature_Celsius -O---K 154 061 000 - 28
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 80864
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 76291
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Total_Offl_Uncorrectabl ----CK 100 100 000 - 0
@@ -92,7 +92,7 @@ Address Access R/W Size Description
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
ATA Error Count: 541 (device log contains only the most recent five errors)
ATA Error Count: 636 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
@@ -107,90 +107,84 @@ Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 541 occurred at disk power-on lifetime: 5620 hours (234 days + 4 hours)
Error 636 occurred at disk power-on lifetime: 5659 hours (235 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 00 00 00 00 a0
04 51 06 00 00 00 00 Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
f5 00 00 00 00 00 a0 00 00:01:53.813 SECURITY FREEZE LOCK
ef 02 00 00 00 00 a0 00 00:01:53.813 SET FEATURES [Enable write cache]
ef aa 00 00 00 00 a0 00 00:01:53.813 SET FEATURES [Enable read look-ahead]
ef 03 45 00 00 00 a0 00 00:01:53.813 SET FEATURES [Set transfer mode]
ef 03 22 00 00 00 a0 00 00:01:53.813 SET FEATURES [Set transfer mode]
ef 10 06 00 00 00 00 00 00:26:02.875 SET FEATURES [Enable SATA feature]
ec 00 00 00 00 00 a0 00 00:26:02.875 IDENTIFY DEVICE
ef 03 45 00 00 00 a0 00 00:26:02.875 SET FEATURES [Set transfer mode]
Error 540 occurred at disk power-on lifetime: 5620 hours (234 days + 4 hours)
Error 635 occurred at disk power-on lifetime: 5659 hours (235 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 00 00 00 00 a0
04 51 06 00 00 00 00 Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
f5 00 00 00 00 00 a0 00 00:01:53.063 SECURITY FREEZE LOCK
ef 02 00 00 00 00 a0 00 00:01:53.063 SET FEATURES [Enable write cache]
ef aa 00 00 00 00 a0 00 00:01:53.063 SET FEATURES [Enable read look-ahead]
ef 03 45 00 00 00 a0 00 00:01:53.063 SET FEATURES [Set transfer mode]
ef 03 22 00 00 00 a0 00 00:01:53.063 SET FEATURES [Set transfer mode]
ef 10 06 00 00 00 00 00 00:26:02.813 SET FEATURES [Enable SATA feature]
ec 00 00 00 00 00 a0 00 00:26:02.813 IDENTIFY DEVICE
00 00 01 01 00 00 a0 00 00:26:02.563 NOP [Abort queued commands]
ec 00 00 00 00 00 00 00 00:25:48.625 IDENTIFY DEVICE
b0 da 00 00 4f c2 00 00 00:25:48.563 SMART RETURN STATUS
Error 539 occurred at disk power-on lifetime: 5620 hours (234 days + 4 hours)
Error 634 occurred at disk power-on lifetime: 5659 hours (235 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 00 00 00 00 a0
04 51 06 00 00 00 00 Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
f5 00 00 00 00 00 a0 00 01:32:54.313 SECURITY FREEZE LOCK
ef 02 00 00 00 00 a0 00 01:32:54.313 SET FEATURES [Enable write cache]
ef aa 00 00 00 00 a0 00 01:32:54.313 SET FEATURES [Enable read look-ahead]
ef 03 45 00 00 00 a0 00 01:32:54.313 SET FEATURES [Set transfer mode]
ef 03 22 00 00 00 a0 00 01:32:54.313 SET FEATURES [Set transfer mode]
ef 10 06 00 00 00 00 00 00:00:19.125 SET FEATURES [Enable SATA feature]
ec 00 00 00 00 00 a0 00 00:00:19.125 IDENTIFY DEVICE
ef 03 45 00 00 00 a0 00 00:00:19.125 SET FEATURES [Set transfer mode]
Error 538 occurred at disk power-on lifetime: 5619 hours (234 days + 3 hours)
Error 633 occurred at disk power-on lifetime: 5659 hours (235 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 00 00 00 00 a0
04 51 06 00 00 00 00 Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
f5 00 00 00 00 00 a0 00 00:14:53.688 SECURITY FREEZE LOCK
ef 02 00 00 00 00 a0 00 00:14:53.688 SET FEATURES [Enable write cache]
ef aa 00 00 00 00 a0 00 00:14:53.688 SET FEATURES [Enable read look-ahead]
ef 03 45 00 00 00 a0 00 00:14:53.688 SET FEATURES [Set transfer mode]
ef 03 22 00 00 00 a0 00 00:14:53.688 SET FEATURES [Set transfer mode]
ef 10 06 00 00 00 00 00 00:00:19.125 SET FEATURES [Enable SATA feature]
ec 00 00 00 00 00 a0 00 00:00:19.125 IDENTIFY DEVICE
00 00 01 01 00 00 a0 00 00:00:18.813 NOP [Abort queued commands]
00 00 01 01 00 00 a0 00 00:00:18.750 NOP [Abort queued commands]
ec 00 00 00 00 00 00 00 00:00:05.250 IDENTIFY DEVICE
Error 537 occurred at disk power-on lifetime: 5619 hours (234 days + 3 hours)
Error 632 occurred at disk power-on lifetime: 5658 hours (235 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 00 00 00 00 a0
04 51 06 00 00 00 00 Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
f5 00 00 00 00 00 a0 00 00:02:10.250 SECURITY FREEZE LOCK
ef 02 00 00 00 00 a0 00 00:02:10.250 SET FEATURES [Enable write cache]
ef aa 00 00 00 00 a0 00 00:02:10.250 SET FEATURES [Enable read look-ahead]
ef 03 45 00 00 00 a0 00 00:02:10.250 SET FEATURES [Set transfer mode]
ef 03 22 00 00 00 a0 00 00:02:10.250 SET FEATURES [Set transfer mode]
ef 10 06 00 00 00 00 00 00:01:13.250 SET FEATURES [Enable SATA feature]
ec 00 00 00 00 00 a0 00 00:01:13.250 IDENTIFY DEVICE
ef 03 45 00 00 00 a0 00 00:01:13.250 SET FEATURES [Set transfer mode]
SMART Extended Self-test Log (GP Log 0x07) not supported