smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.0-RELEASE-p6 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -11,7 +11,7 @@ User Capacity: 120,034,123,776 bytes [120 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Mon May 13 11:26:12 2024 WEST
|
||||
Local Time is: Tue May 14 12:01:58 2024 WEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -63,17 +63,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
|
||||
3 Spin_Up_Time PO---- 189 186 021 - 1525
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1526
|
||||
3 Spin_Up_Time PO---- 189 186 021 - 1516
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1533
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 1274
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 1279
|
||||
10 Spin_Retry_Count -O--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1495
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1463
|
||||
193 Load_Cycle_Count -O--CK 185 185 000 - 45175
|
||||
194 Temperature_Celsius -O---K 117 096 000 - 30
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1502
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1470
|
||||
193 Load_Cycle_Count -O--CK 185 185 000 - 45304
|
||||
194 Temperature_Celsius -O---K 112 096 000 - 35
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 253 000 - 0
|
||||
@@ -125,8 +125,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: --/29 Celsius
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: --/37 Celsius
|
||||
Lifetime Min/Max Temperature: --/52 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -134,7 +134,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/65 Celsius
|
||||
Min/Max Temperature Limit: 1/70 Celsius
|
||||
Temperature History Size (Index): 128 (114)
|
||||
Temperature History Size (Index): 128 (79)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -147,6 +147,6 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 25 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 1251 Vendor specific
|
||||
0x000a 2 43 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 5821 Vendor specific
|
||||
|
||||
|