@@ -13,7 +13,7 @@ Form Factor: 3.5 inches
Device is: Not in smartctl database 7.3/5319
ATA Version is: ACS-4 published, ANSI INCITS 529-2018
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Apr 12 01:42:11 2023 EDT
Local Time is: Mon Jun 5 08:32:37 2023 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -28,8 +28,8 @@ Wt Cache Reorder: Enabled
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
@@ -64,18 +64,18 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 001 - 0
2 Throughput_Performance --S--- 145 145 054 - 60
3 Spin_Up_Time POS--- 083 083 001 - 347 (Average 347)
4 Start_Stop_Count -O--C- 048 048 000 - 20879
3 Spin_Up_Time POS--- 083 083 001 - 350 (Average 350)
4 Start_Stop_Count -O--C- 048 048 000 - 20888
5 Reallocated_Sector_Ct PO--CK 100 100 001 - 0
7 Seek_Error_Rate -O-R-- 100 100 001 - 0
8 Seek_Time_Performance --S--- 128 128 020 - 18
9 Power_On_Hours -O--C- 099 099 000 - 9222
9 Power_On_Hours -O--C- 099 099 000 - 10131
10 Spin_Retry_Count -O--C- 100 100 001 - 0
12 Power_Cycle_Count -O--CK 001 001 000 - 7880
12 Power_Cycle_Count -O--CK 001 001 000 - 7889
22 Unknown_Attribute PO---K 100 100 025 - 100
192 Power-Off_Retract_Count -O--CK 097 097 000 - 23571
193 Load_Cycle_Count -O--C- 097 097 000 - 23571
194 Temperature_Celsius -O---- 037 037 000 - 41 (Min/Max 21/59)
192 Power-Off_Retract_Count -O--CK 097 097 000 - 24932
193 Load_Cycle_Count -O--C- 097 097 000 - 24932
194 Temperature_Celsius -O---- 047 047 000 - 35 (Min/Max 21/59)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O---K 100 100 000 - 0
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
@@ -138,8 +138,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 41 Celsius
Power Cycle Min/Max Temperature: 33/44 Celsius
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 34/42 Celsius
Lifetime Min/Max Temperature: 21/59 Celsius
Under/Over Temperature Limit Count: 0/0
SMART Status: 0xc24f (PASSED)
@@ -150,7 +150,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/65 Celsius
Min/Max Temperature Limit: -40/70 Celsius
Temperature History Size (Index): 128 (126)
Temperature History Size (Index): 128 (4)
SCT Error Recovery Control:
Read: Disabled
@@ -159,17 +159,17 @@ SCT Error Recovery Control:
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 7880 --- Lifetime Power-On Resets
0x01 0x010 4 9222 --- Power-on Hours
0x01 0x018 6 97174984346 --- Logical Sectors Written
0x01 0x020 6 263190987 --- Number of Write Commands
0x01 0x028 6 107342730819 --- Logical Sectors Read
0x01 0x030 6 287262434 --- Number of Read Commands
0x01 0x038 6 33202015200 --- Date and Time TimeStamp
0x01 0x008 4 7889 --- Lifetime Power-On Resets
0x01 0x010 4 10131 --- Power-on Hours
0x01 0x018 6 100331025128 --- Logical Sectors Written
0x01 0x020 6 271579848 --- Number of Write Commands
0x01 0x028 6 129986902807 --- Logical Sectors Read
0x01 0x030 6 342736975 --- Number of Read Commands
0x01 0x038 6 36474841000 --- Date and Time TimeStamp
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 6740 --- Spindle Motor Power-on Hours
0x03 0x010 4 6740 --- Head Flying Hours
0x03 0x018 4 23571 --- Head Load Events
0x03 0x008 4 7231 --- Spindle Motor Power-on Hours
0x03 0x010 4 7231 --- Head Flying Hours
0x03 0x018 4 24932 --- Head Load Events
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
0x03 0x028 4 1 --- Read Recovery Attempts
0x03 0x030 4 0 --- Number of Mechanical Start Failures
@@ -177,9 +177,9 @@ Page Offset Size Value Flags Description
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 41 --- Current Temperature
0x05 0x010 1 39 N-- Average Short Term Temperature
0x05 0x018 1 41 N-- Average Long Term Temperature
0x05 0x008 1 35 --- Current Temperature
0x05 0x010 1 38 N-- Average Short Term Temperature
0x05 0x018 1 40 N-- Average Long Term Temperature
0x05 0x020 1 59 --- Highest Temperature
0x05 0x028 1 21 --- Lowest Temperature
0x05 0x030 1 57 N-- Highest Average Short Term Temperature
@@ -191,8 +191,8 @@ Page Offset Size Value Flags Description
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 91901 --- Number of Hardware Resets
0x06 0x010 4 39268 --- Number of ASR Events
0x06 0x008 4 91998 --- Number of Hardware Resets
0x06 0x010 4 39291 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|||_ C monitored condition met
@@ -212,8 +212,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 25 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 25 Device-to-host register FISes sent due to a COMRESET
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 13 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS