mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 35, modified: 3308)
This commit is contained in:
@@ -1,5 +1,5 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 12.3-RELEASE-p6 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.3-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Re
|
||||
@@ -10,10 +10,10 @@ Firmware Version: 01.01K01
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Nov 29 21:12:44 2022 CET
|
||||
Local Time is: Sat Aug 24 10:25:30 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,18 +65,18 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 175 169 021 - 6250
|
||||
4 Start_Stop_Count -O--CK 083 083 000 - 17364
|
||||
3 Spin_Up_Time POS--K 183 169 021 - 5816
|
||||
4 Start_Stop_Count -O--CK 083 083 000 - 17381
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 017 017 000 - 60817
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 75977
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 694
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 711
|
||||
183 Runtime_Bad_Block -O--CK 076 076 000 - 24
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 11
|
||||
193 Load_Cycle_Count -O--CK 195 195 000 - 17363
|
||||
194 Temperature_Celsius -O---K 102 088 000 - 48
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 20
|
||||
193 Load_Cycle_Count -O--CK 195 195 000 - 17371
|
||||
194 Temperature_Celsius -O---K 105 088 000 - 45
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -117,24 +117,24 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 60773 -
|
||||
# 2 Extended offline Completed without error 00% 60610 -
|
||||
# 3 Extended offline Completed without error 00% 60442 -
|
||||
# 4 Extended offline Completed without error 00% 60275 -
|
||||
# 5 Extended offline Completed without error 00% 60107 -
|
||||
# 6 Extended offline Completed without error 00% 59938 -
|
||||
# 7 Extended offline Completed without error 00% 59770 -
|
||||
# 8 Extended offline Completed without error 00% 59602 -
|
||||
# 9 Extended offline Completed without error 00% 59434 -
|
||||
#10 Extended offline Completed without error 00% 59267 -
|
||||
#11 Extended offline Completed without error 00% 59099 -
|
||||
#12 Extended offline Completed without error 00% 58932 -
|
||||
#13 Extended offline Completed without error 00% 58763 -
|
||||
#14 Extended offline Completed without error 00% 58595 -
|
||||
#15 Extended offline Completed without error 00% 58427 -
|
||||
#16 Extended offline Completed without error 00% 58259 -
|
||||
#17 Extended offline Completed without error 00% 58092 -
|
||||
#18 Extended offline Completed without error 00% 57924 -
|
||||
# 1 Extended offline Completed without error 00% 10312 -
|
||||
# 2 Extended offline Completed without error 00% 10145 -
|
||||
# 3 Extended offline Completed without error 00% 9977 -
|
||||
# 4 Extended offline Completed without error 00% 9809 -
|
||||
# 5 Extended offline Completed without error 00% 9641 -
|
||||
# 6 Extended offline Completed without error 00% 9473 -
|
||||
# 7 Extended offline Completed without error 00% 9305 -
|
||||
# 8 Extended offline Completed without error 00% 9137 -
|
||||
# 9 Extended offline Completed without error 00% 8970 -
|
||||
#10 Extended offline Completed without error 00% 8802 -
|
||||
#11 Extended offline Completed without error 00% 8634 -
|
||||
#12 Extended offline Completed without error 00% 8466 -
|
||||
#13 Extended offline Completed without error 00% 8298 -
|
||||
#14 Extended offline Completed without error 00% 8130 -
|
||||
#15 Extended offline Completed without error 00% 7963 -
|
||||
#16 Extended offline Completed without error 00% 7795 -
|
||||
#17 Extended offline Completed without error 00% 7631 -
|
||||
#18 Extended offline Completed without error 00% 7464 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -150,8 +150,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 48 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/54 Celsius
|
||||
Current Temperature: 45 Celsius
|
||||
Power Cycle Min/Max Temperature: 42/54 Celsius
|
||||
Lifetime Min/Max Temperature: 0/63 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -163,7 +163,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (114)
|
||||
Temperature History Size (Index): 478 (326)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -188,7 +188,7 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 736672 Vendor specific
|
||||
0x8000 4 1444158 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 12.3-RELEASE-p6 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.3-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Re
|
||||
@@ -10,10 +10,10 @@ Firmware Version: 01.01K01
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Nov 29 21:12:44 2022 CET
|
||||
Local Time is: Sat Aug 24 10:25:30 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,18 +65,18 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 171 171 021 - 6416
|
||||
4 Start_Stop_Count -O--CK 083 083 000 - 17280
|
||||
3 Spin_Up_Time POS--K 177 171 021 - 6116
|
||||
4 Start_Stop_Count -O--CK 083 083 000 - 17297
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 030 030 000 - 51677
|
||||
9 Power_On_Hours -O--CK 009 009 000 - 66837
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 657
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 674
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 11
|
||||
193 Load_Cycle_Count -O--CK 195 195 000 - 17279
|
||||
194 Temperature_Celsius -O---K 105 092 000 - 45
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 20
|
||||
193 Load_Cycle_Count -O--CK 195 195 000 - 17287
|
||||
194 Temperature_Celsius -O---K 104 092 000 - 46
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -117,24 +117,24 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 51635 -
|
||||
# 2 Extended offline Completed without error 00% 51472 -
|
||||
# 3 Extended offline Completed without error 00% 51304 -
|
||||
# 4 Extended offline Completed without error 00% 51136 -
|
||||
# 5 Extended offline Completed without error 00% 50968 -
|
||||
# 6 Extended offline Completed without error 00% 50799 -
|
||||
# 7 Extended offline Completed without error 00% 50631 -
|
||||
# 8 Extended offline Completed without error 00% 50464 -
|
||||
# 9 Extended offline Completed without error 00% 50296 -
|
||||
#10 Extended offline Completed without error 00% 50128 -
|
||||
#11 Extended offline Completed without error 00% 49960 -
|
||||
#12 Extended offline Completed without error 00% 49794 -
|
||||
#13 Extended offline Completed without error 00% 49624 -
|
||||
#14 Extended offline Completed without error 00% 49457 -
|
||||
#15 Extended offline Completed without error 00% 49289 -
|
||||
#16 Extended offline Completed without error 00% 49121 -
|
||||
#17 Extended offline Completed without error 00% 48953 -
|
||||
#18 Extended offline Completed without error 00% 48785 -
|
||||
# 1 Extended offline Completed without error 00% 1173 -
|
||||
# 2 Extended offline Completed without error 00% 1006 -
|
||||
# 3 Extended offline Completed without error 00% 838 -
|
||||
# 4 Extended offline Completed without error 00% 670 -
|
||||
# 5 Extended offline Completed without error 00% 502 -
|
||||
# 6 Extended offline Completed without error 00% 334 -
|
||||
# 7 Extended offline Completed without error 00% 166 -
|
||||
# 8 Extended offline Completed without error 00% 65535 -
|
||||
# 9 Extended offline Completed without error 00% 65367 -
|
||||
#10 Extended offline Completed without error 00% 65199 -
|
||||
#11 Extended offline Completed without error 00% 65031 -
|
||||
#12 Extended offline Completed without error 00% 64863 -
|
||||
#13 Extended offline Completed without error 00% 64695 -
|
||||
#14 Extended offline Completed without error 00% 64528 -
|
||||
#15 Extended offline Completed without error 00% 64360 -
|
||||
#16 Extended offline Completed without error 00% 64192 -
|
||||
#17 Extended offline Completed without error 00% 64029 -
|
||||
#18 Extended offline Completed without error 00% 63861 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -150,8 +150,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 45 Celsius
|
||||
Power Cycle Min/Max Temperature: 34/50 Celsius
|
||||
Current Temperature: 46 Celsius
|
||||
Power Cycle Min/Max Temperature: 44/54 Celsius
|
||||
Lifetime Min/Max Temperature: 0/58 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -163,7 +163,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (366)
|
||||
Temperature History Size (Index): 478 (88)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -188,5 +188,5 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 736663 Vendor specific
|
||||
0x8000 4 1444141 Vendor specific
|
||||
|
||||
|
Reference in New Issue