smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Mon May 9 06:35:54 2022 CEST
|
||||
Local Time is: Wed May 10 09:02:51 2023 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 128
|
||||
@@ -28,8 +28,8 @@ Wt Cache Reorder: Unknown
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
@@ -69,13 +69,13 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 42
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 018 018 000 - 60017
|
||||
9 Power_On_Hours -O--CK 006 006 000 - 68765
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 41
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 39
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2
|
||||
194 Temperature_Celsius -O---K 123 109 000 - 29
|
||||
194 Temperature_Celsius -O---K 122 097 000 - 30
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -116,7 +116,8 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 8392 -
|
||||
# 1 Short offline Completed without error 00% 90 -
|
||||
# 2 Short offline Completed without error 00% 8392 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -132,9 +133,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/34 Celsius
|
||||
Lifetime Min/Max Temperature: 27/43 Celsius
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/55 Celsius
|
||||
Lifetime Min/Max Temperature: 27/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -142,7 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (171)
|
||||
Temperature History Size (Index): 478 (137)
|
||||
|
||||
SMART WRITE LOG does not return COUNT and LBA_LOW register
|
||||
SCT (Get) Error Recovery Control command failed
|
||||
@@ -160,7 +161,7 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 32 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 76 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 5248240 Vendor specific
|
||||
0x8000 4 36847775 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Mon May 9 06:35:54 2022 CEST
|
||||
Local Time is: Wed May 10 09:02:51 2023 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 128
|
||||
@@ -28,8 +28,8 @@ Wt Cache Reorder: Unknown
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
@@ -69,18 +69,18 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 38
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 020 020 000 - 58954
|
||||
9 Power_On_Hours -O--CK 008 008 000 - 67706
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 37
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 35
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2
|
||||
194 Temperature_Celsius -O---K 122 110 000 - 30
|
||||
194 Temperature_Celsius -O---K 122 096 000 - 30
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 3
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 4
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -132,8 +132,8 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/35 Celsius
|
||||
Lifetime Min/Max Temperature: 27/42 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/56 Celsius
|
||||
Lifetime Min/Max Temperature: 27/56 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (116)
|
||||
Temperature History Size (Index): 478 (82)
|
||||
|
||||
SMART WRITE LOG does not return COUNT and LBA_LOW register
|
||||
SCT (Get) Error Recovery Control command failed
|
||||
@@ -159,9 +159,9 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 32 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 76 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 5248253 Vendor specific
|
||||
0x8000 4 36847867 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -14,7 +14,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Sat Nov 4 17:23:54 2023 CET
|
||||
Local Time is: Sat Nov 11 15:34:10 2023 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -70,13 +70,13 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 651
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 008 008 000 - 67732
|
||||
9 Power_On_Hours -O--CK 007 007 000 - 67898
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 648
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 173
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 477
|
||||
194 Temperature_Celsius -O---K 107 092 000 - 45 (Min/Max 38/49)
|
||||
194 Temperature_Celsius -O---K 106 092 000 - 46 (Min/Max 38/49)
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -150,7 +150,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 45 Celsius
|
||||
Current Temperature: 46 Celsius
|
||||
Power Cycle Min/Max Temperature: 38/49 Celsius
|
||||
Lifetime Min/Max Temperature: 38/60 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -160,7 +160,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (117)
|
||||
Temperature History Size (Index): 478 (40)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 80 (8.0 seconds)
|
||||
@@ -181,7 +181,7 @@ ID Size Value Description
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 1120102 Vendor specific
|
||||
0x8000 4 1717719 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -14,7 +14,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Sat Nov 4 17:23:54 2023 CET
|
||||
Local Time is: Sat Nov 11 15:34:10 2023 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -70,13 +70,13 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 114
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 029 029 000 - 51849
|
||||
9 Power_On_Hours -O--CK 029 029 000 - 52015
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 107
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 75
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 38
|
||||
194 Temperature_Celsius -O---K 102 087 000 - 50 (Min/Max 41/54)
|
||||
194 Temperature_Celsius -O---K 101 087 000 - 51 (Min/Max 41/54)
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 5
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 5
|
||||
@@ -132,7 +132,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 50 Celsius
|
||||
Current Temperature: 51 Celsius
|
||||
Power Cycle Min/Max Temperature: 41/54 Celsius
|
||||
Lifetime Min/Max Temperature: 41/65 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (250)
|
||||
Temperature History Size (Index): 478 (123)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 80 (8.0 seconds)
|
||||
@@ -163,5 +163,5 @@ ID Size Value Description
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 1120100 Vendor specific
|
||||
0x8000 4 1717715 Vendor specific
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 14.0-CURRENT amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.0-BETA4 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Black
|
||||
@@ -11,10 +11,10 @@ User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jun 17 09:20:49 2023 CDT
|
||||
Local Time is: Fri Oct 6 18:14:55 2023 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,17 +66,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 189 179 021 - 3508
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2092
|
||||
3 Spin_Up_Time POS--K 200 179 021 - 3000
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2147
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 100 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 8876
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 085 085 000 - 11536
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 76
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 30
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2061
|
||||
194 Temperature_Celsius -O---K 118 095 000 - 29
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 131
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 61
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2085
|
||||
194 Temperature_Celsius -O---K 117 095 000 - 30
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -134,8 +134,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/30 Celsius
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/31 Celsius
|
||||
Lifetime Min/Max Temperature: 19/52 Celsius
|
||||
Specified Max Operating Temperature: 60 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -148,7 +148,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (33)
|
||||
Temperature History Size (Index): 478 (272)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -157,29 +157,29 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 76 -D- Lifetime Power-On Resets
|
||||
0x01 0x010 4 8876 -D- Power-on Hours
|
||||
0x01 0x018 6 17163799918 -D- Logical Sectors Written
|
||||
0x01 0x020 6 57927068 -D- Number of Write Commands
|
||||
0x01 0x028 6 38424831245 -D- Logical Sectors Read
|
||||
0x01 0x030 6 161743716 -D- Number of Read Commands
|
||||
0x01 0x038 6 1888828928 -D- Date and Time TimeStamp
|
||||
0x01 0x048 2 316 ND- Workload Utilization
|
||||
0x01 0x008 4 131 -D- Lifetime Power-On Resets
|
||||
0x01 0x010 4 11536 -D- Power-on Hours
|
||||
0x01 0x018 6 17607648246 -D- Logical Sectors Written
|
||||
0x01 0x020 6 58324623 -D- Number of Write Commands
|
||||
0x01 0x028 6 46703027930 -D- Logical Sectors Read
|
||||
0x01 0x030 6 180308493 -D- Number of Read Commands
|
||||
0x01 0x038 6 2874894336 -D- Date and Time TimeStamp
|
||||
0x01 0x048 2 365 ND- Workload Utilization
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 7957 -D- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 7957 -D- Head Flying Hours
|
||||
0x03 0x018 4 2092 -D- Head Load Events
|
||||
0x03 0x008 4 10617 -D- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 10617 -D- Head Flying Hours
|
||||
0x03 0x018 4 2147 -D- Head Load Events
|
||||
0x03 0x020 4 0 -D- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 -D- Read Recovery Attempts
|
||||
0x03 0x030 4 0 -D- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 -D- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 30 -D- Number of High Priority Unload Events
|
||||
0x03 0x040 4 61 -D- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 -D- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 -D- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 29 -D- Current Temperature
|
||||
0x05 0x010 1 30 -D- Average Short Term Temperature
|
||||
0x05 0x008 1 30 -D- Current Temperature
|
||||
0x05 0x010 1 29 -D- Average Short Term Temperature
|
||||
0x05 0x018 1 30 -D- Average Long Term Temperature
|
||||
0x05 0x020 1 53 -D- Highest Temperature
|
||||
0x05 0x028 1 23 -D- Lowest Temperature
|
||||
@@ -192,8 +192,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 -D- Time in Under-Temperature
|
||||
0x05 0x068 1 0 -D- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 2898 -D- Number of Hardware Resets
|
||||
0x06 0x010 4 629 -D- Number of ASR Events
|
||||
0x06 0x008 4 3595 -D- Number of Hardware Resets
|
||||
0x06 0x010 4 1088 -D- Number of ASR Events
|
||||
0x06 0x018 4 0 -D- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
@@ -212,8 +212,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 9 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 15 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 13 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 20 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
Reference in New Issue