1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 35, modified: 3308)

This commit is contained in:
Andrey Ponomarenko
2025-01-05 02:37:11 +03:00
parent f68c38aa35
commit 8c515ea896
3343 changed files with 73552 additions and 65384 deletions

View File

@@ -11,10 +11,10 @@ Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Utilization: 250,943,107,072 [250 GB]
Namespace 1 Utilization: 392,441,954,304 [392 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 7c3548 ...
Local Time is: Fri May 10 22:01:18 2024 CEST
Local Time is: Wed Jul 10 11:46:13 2024 CEST
Firmware Updates (0x14): 2 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
@@ -36,25 +36,25 @@ SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 38 Celsius
Temperature: 46 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 0%
Data Units Read: 20,711 [10.6 GB]
Data Units Written: 958,396 [490 GB]
Host Read Commands: 452,727
Host Write Commands: 9,752,484
Controller Busy Time: 24
Data Units Read: 34,875 [17.8 GB]
Data Units Written: 2,734,116 [1.39 TB]
Host Read Commands: 696,318
Host Write Commands: 27,806,158
Controller Busy Time: 99
Power Cycles: 10
Power On Hours: 1,236
Power On Hours: 2,696
Unsafe Shutdowns: 5
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 50 Celsius
Temperature Sensor 2: 33 Celsius
Temperature Sensor 3: 38 Celsius
Temperature Sensor 1: 60 Celsius
Temperature Sensor 2: 38 Celsius
Temperature Sensor 3: 46 Celsius
Error Information (NVMe Log 0x01, 16 of 256 entries)
No Errors Logged

View File

@@ -11,10 +11,10 @@ Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Utilization: 10,207,477,760 [10.2 GB]
Namespace 1 Utilization: 502,219,132,928 [502 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 7c3548 ...
Local Time is: Wed Jul 17 12:37:37 2024 CEST
Local Time is: Mon Sep 16 21:03:59 2024 CEST
Firmware Updates (0x14): 2 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
@@ -36,25 +36,25 @@ SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 42 Celsius
Temperature: 60 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 0%
Data Units Read: 36,155 [18.5 GB]
Data Units Written: 48,077 [24.6 GB]
Host Read Commands: 171,517
Host Write Commands: 208,208
Controller Busy Time: 1
Power Cycles: 12
Power On Hours: 2
Unsafe Shutdowns: 7
Percentage Used: 6%
Data Units Read: 619,745 [317 GB]
Data Units Written: 31,895,596 [16.3 TB]
Host Read Commands: 4,020,191
Host Write Commands: 166,548,439
Controller Busy Time: 144,700
Power Cycles: 22
Power On Hours: 978
Unsafe Shutdowns: 17
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 53 Celsius
Temperature Sensor 2: 35 Celsius
Temperature Sensor 3: 42 Celsius
Temperature Sensor 1: 76 Celsius
Temperature Sensor 2: 50 Celsius
Temperature Sensor 3: 60 Celsius
Error Information (NVMe Log 0x01, 16 of 256 entries)
No Errors Logged