1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 35, modified: 3308)

This commit is contained in:
Andrey Ponomarenko
2025-01-05 02:37:11 +03:00
parent f68c38aa35
commit 8c515ea896
3343 changed files with 73552 additions and 65384 deletions

View File

@@ -1,4 +1,4 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p4 amd64] (local build)
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -14,7 +14,7 @@ TRIM Command: Available, deterministic, zeroed
Device is: Not in smartctl database 7.3/5528
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Nov 3 08:16:40 2023 -05
Local Time is: Tue Jun 4 12:49:44 2024 -05
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -64,29 +64,29 @@ SCT capabilities: (0x0035) SCT Status supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 25074422
5 Reallocated_Sector_Ct PO--CK 086 086 000 - 325
9 Power_On_Hours -O--CK 100 100 000 - 44470
12 Power_Cycle_Count -O--CK 100 100 000 - 93617
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 26382378
5 Reallocated_Sector_Ct PO--CK 085 085 000 - 337
9 Power_On_Hours -O--CK 100 100 000 - 46303
12 Power_Cycle_Count -O--CK 100 100 000 - 93779
171 Unknown_Attribute -O--CK 100 100 000 - 0
172 Unknown_Attribute -O--CK 100 100 000 - 0
173 Unknown_Attribute -O--CK 154 154 000 - 6076
174 Unknown_Attribute -O--CK 100 100 000 - 80
180 Unused_Rsvd_Blk_Cnt_Tot PO--CK 000 000 000 - 1834
173 Unknown_Attribute -O--CK 128 128 000 - 6846
174 Unknown_Attribute -O--CK 100 100 000 - 118
180 Unused_Rsvd_Blk_Cnt_Tot PO--CK 000 000 000 - 1822
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 29
194 Temperature_Celsius -O---K 065 052 000 - 35 (Min/Max 19/48)
196 Reallocated_Event_Count -O--CK 100 100 000 - 325
194 Temperature_Celsius -O---K 063 047 000 - 37 (Min/Max 19/53)
196 Reallocated_Event_Count -O--CK 100 100 000 - 337
197 Current_Pending_Sector -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
202 Unknown_SSD_Attribute P---CK 154 154 000 - 202
202 Unknown_SSD_Attribute P---CK 128 128 000 - 228
206 Unknown_SSD_Attribute -OSR-- 100 100 000 - 0
210 Unknown_Attribute -O--CK 100 100 000 - 58
246 Unknown_Attribute -O--CK 100 100 000 - 158015213858
247 Unknown_Attribute -O--CK 100 100 000 - 4973367253
248 Unknown_Attribute -O--CK 100 100 000 - 1472163843
210 Unknown_Attribute -O--CK 100 100 000 - 59
246 Unknown_Attribute -O--CK 100 100 000 - 162226634672
247 Unknown_Attribute -O--CK 100 100 000 - 5106074498
248 Unknown_Attribute -O--CK 100 100 000 - 13956500514
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -275,22 +275,21 @@ Error 22 [21] occurred at disk power-on lifetime: 2554 hours (106 days + 10 hour
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 44356 -
# 2 Short offline Completed without error 00% 44328 -
# 3 Vendor (0xff) Completed without error 00% 44239 -
# 4 Vendor (0xff) Completed without error 00% 44224 -
# 5 Short offline Completed without error 00% 44209 -
# 6 Short offline Completed without error 00% 44209 -
# 7 Vendor (0xff) Completed without error 00% 42017 -
# 8 Vendor (0xff) Completed without error 00% 41177 -
# 9 Vendor (0xff) Completed without error 00% 36112 -
#10 Vendor (0xff) Completed without error 00% 32538 -
#11 Vendor (0xff) Completed without error 00% 25490 -
#12 Vendor (0xff) Completed without error 00% 25324 -
#13 Vendor (0xff) Completed without error 00% 25055 -
#14 Vendor (0xff) Completed without error 00% 24878 -
#15 Vendor (0xff) Completed without error 00% 24628 -
#16 Vendor (0xff) Completed without error 00% 23547 -
# 1 Short offline Completed without error 00% 45901 -
# 2 Short offline Completed without error 00% 44805 -
# 3 Short offline Completed without error 00% 44525 -
# 4 Short offline Completed without error 00% 44472 -
# 5 Vendor (0xff) Completed without error 00% 44356 -
# 6 Short offline Completed without error 00% 44328 -
# 7 Vendor (0xff) Completed without error 00% 44239 -
# 8 Vendor (0xff) Completed without error 00% 44224 -
# 9 Short offline Completed without error 00% 44209 -
#10 Short offline Completed without error 00% 44209 -
#11 Vendor (0xff) Completed without error 00% 42017 -
#12 Vendor (0xff) Completed without error 00% 41177 -
#13 Vendor (0xff) Completed without error 00% 36112 -
#14 Vendor (0xff) Completed without error 00% 32538 -
#15 Vendor (0xff) Completed without error 00% 25490 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
@@ -306,9 +305,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 26/36 Celsius
Lifetime Min/Max Temperature: 19/48 Celsius
Current Temperature: 37 Celsius
Power Cycle Min/Max Temperature: 27/45 Celsius
Lifetime Min/Max Temperature: 19/53 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
@@ -316,29 +315,29 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (210)
Temperature History Size (Index): 478 (140)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 93617 --- Lifetime Power-On Resets
0x01 0x010 4 44470 --- Power-on Hours
0x01 0x018 6 158015213858 --- Logical Sectors Written
0x01 0x020 6 6550681855 --- Number of Write Commands
0x01 0x028 6 47751574245 --- Logical Sectors Read
0x01 0x030 6 1199598779 --- Number of Read Commands
0x01 0x008 4 93779 --- Lifetime Power-On Resets
0x01 0x010 4 46303 --- Power-on Hours
0x01 0x018 6 162226634672 --- Logical Sectors Written
0x01 0x020 6 6670339808 --- Number of Write Commands
0x01 0x028 6 48498797450 --- Logical Sectors Read
0x01 0x030 6 1208172788 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 29 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 93573 --- Resets Between Cmd Acceptance and Completion
0x04 0x010 4 93701 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 35 --- Current Temperature
0x05 0x010 1 34 --- Average Short Term Temperature
0x05 0x018 1 34 --- Average Long Term Temperature
0x05 0x020 1 48 --- Highest Temperature
0x05 0x008 1 37 --- Current Temperature
0x05 0x010 1 37 --- Average Short Term Temperature
0x05 0x018 1 35 --- Average Long Term Temperature
0x05 0x020 1 53 --- Highest Temperature
0x05 0x028 1 19 --- Lowest Temperature
0x05 0x030 1 43 --- Highest Average Short Term Temperature
0x05 0x030 1 45 --- Highest Average Short Term Temperature
0x05 0x038 1 22 --- Lowest Average Short Term Temperature
0x05 0x040 1 41 --- Highest Average Long Term Temperature
0x05 0x048 1 25 --- Lowest Average Long Term Temperature
@@ -347,11 +346,11 @@ Page Offset Size Value Flags Description
0x05 0x060 4 - --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 100 --- Number of Hardware Resets
0x06 0x008 4 302 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 59 N-- Percentage Used Endurance Indicator
0x07 0x008 1 61 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
@@ -361,7 +360,7 @@ Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 5 Device-to-host register FISes sent due to a COMRESET
0x000a 4 36 Device-to-host register FISes sent due to a COMRESET