1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 35, modified: 3308)

This commit is contained in:
Andrey Ponomarenko
2025-01-05 02:37:11 +03:00
parent f68c38aa35
commit 8c515ea896
3343 changed files with 73552 additions and 65384 deletions

View File

@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Jun 20 09:33:02 2023 CEST
Local Time is: Tue Jun 20 09:42:24 2023 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -63,9 +63,9 @@ SCT capabilities: (0x0025) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O--CK 095 095 050 - 2/4178628
1 Raw_Read_Error_Rate -O--CK 095 095 050 - 2/4180079
5 Retired_Block_Count PO--CK 100 100 003 - 0
9 Power_On_Hours_and_Msec -O--CK 025 025 000 - 66168h+20m+55.020s
9 Power_On_Hours_and_Msec -O--CK 025 025 000 - 66168h+30m+16.800s
12 Power_Cycle_Count -O--CK 100 100 000 - 159
171 Program_Fail_Count -O-R-- 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
@@ -76,13 +76,13 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
187 Reported_Uncorrect -O--C- 100 100 000 - 0
189 Airflow_Temperature_Cel ------ 032 041 000 - 32 (Min/Max 21/41)
194 Temperature_Celsius -O---K 032 041 000 - 32 (Min/Max 21/41)
195 ECC_Uncorr_Error_Count --SRC- 098 098 000 - 2/4178628
195 ECC_Uncorr_Error_Count --SRC- 098 098 000 - 2/4180079
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
201 Unc_Soft_Read_Err_Rate --SRC- 098 098 000 - 2/4178628
204 Soft_ECC_Correct_Rate --SRC- 098 098 000 - 2/4178628
201 Unc_Soft_Read_Err_Rate --SRC- 098 098 000 - 2/4180079
204 Soft_ECC_Correct_Rate --SRC- 098 098 000 - 2/4180079
230 Life_Curve_Status PO--C- 100 100 000 - 100
231 SSD_Life_Left ------ 093 093 011 - 111669149696
233 SandForce_Internal -O--CK 000 000 000 - 38373
233 SandForce_Internal -O--CK 000 000 000 - 38374
234 SandForce_Internal -O--CK 000 000 000 - 28023
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 28023
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 1355
@@ -159,7 +159,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/85 Celsius
Temperature History Size (Index): 478 (14)
Temperature History Size (Index): 478 (15)
SCT Error Recovery Control command not supported
@@ -168,8 +168,8 @@ Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 159 --- Lifetime Power-On Resets
0x01 0x010 4 66168 --- Power-on Hours
0x01 0x018 6 58769482315 --- Logical Sectors Written
0x01 0x028 6 2842629984 --- Logical Sectors Read
0x01 0x018 6 58769673384 --- Logical Sectors Written
0x01 0x028 6 2842631435 --- Logical Sectors Read
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 19 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 5 --- Resets Between Cmd Acceptance and Completion

View File

@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: In smartctl database 7.3/5528
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Nov 2 19:57:53 2023 CET
Local Time is: Sun Nov 5 22:21:08 2023 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,7 +65,7 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O--CK 120 120 050 - 2/0
5 Retired_Block_Count PO--CK 100 100 003 - 0
9 Power_On_Hours_and_Msec -O--CK 097 097 000 - 3373h+55m+22.880s
9 Power_On_Hours_and_Msec -O--CK 097 097 000 - 3448h+18m+34.830s
12 Power_Cycle_Count -O--CK 100 100 000 - 549
171 Program_Fail_Count -O-R-- 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
@@ -74,8 +74,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
181 Program_Fail_Count -O-R-- 100 100 000 - 0
182 Erase_Fail_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--C- 100 100 000 - 0
189 Airflow_Temperature_Cel ------ 046 055 000 - 46 (Min/Max 17/55)
194 Temperature_Celsius -O---K 046 055 000 - 46 (Min/Max 17/55)
189 Airflow_Temperature_Cel ------ 045 055 000 - 45 (Min/Max 17/55)
194 Temperature_Celsius -O---K 045 055 000 - 45 (Min/Max 17/55)
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 2/0
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
201 Unc_Soft_Read_Err_Rate --SRC- 120 120 000 - 2/0
@@ -130,7 +130,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
Device State: Active (0)
Current Temperature: 46 Celsius
Current Temperature: 45 Celsius
Power Cycle Min/Max Temperature: 17/55 Celsius
Lifetime Min/Max Temperature: 17/55 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -140,7 +140,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/85 Celsius
Temperature History Size (Index): 478 (103)
Temperature History Size (Index): 478 (113)
SCT Error Recovery Control command not supported
@@ -148,14 +148,14 @@ Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 549 --- Lifetime Power-On Resets
0x01 0x010 4 3373 --- Power-on Hours
0x01 0x010 4 3448 --- Power-on Hours
0x01 0x018 6 1128768420 --- Logical Sectors Written
0x01 0x028 6 1625393791 --- Logical Sectors Read
0x01 0x028 6 1625393794 --- Logical Sectors Read
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 519 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 46 --- Current Temperature
0x05 0x008 1 45 --- Current Temperature
0x05 0x010 1 41 --- Average Short Term Temperature
0x05 0x018 1 43 --- Average Long Term Temperature
0x05 0x020 1 55 --- Highest Temperature

View File

@@ -1,4 +1,4 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: In smartctl database 7.3/5528
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Mon Jan 1 18:19:09 2024 CET
Local Time is: Fri Mar 29 14:12:26 2024 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -63,9 +63,9 @@ SCT capabilities: (0x0025) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O--CK 095 095 050 - 0/3127793
1 Raw_Read_Error_Rate -O--CK 095 095 050 - 0/7672754
5 Retired_Block_Count PO--CK 100 100 003 - 0
9 Power_On_Hours_and_Msec -O--CK 092 092 000 - 7420h+54m+36.860s
9 Power_On_Hours_and_Msec -O--CK 090 090 000 - 9527h+56m+20.750s
12 Power_Cycle_Count -O--CK 094 094 000 - 7076
171 Program_Fail_Count -O-R-- 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
@@ -74,19 +74,19 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
181 Program_Fail_Count -O-R-- 100 100 000 - 0
182 Erase_Fail_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--C- 100 100 000 - 0
189 Airflow_Temperature_Cel ------ 016 040 000 - 16 (Min/Max 14/40)
194 Temperature_Celsius -O---K 016 040 000 - 16 (Min/Max 14/40)
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 0/3127793
189 Airflow_Temperature_Cel ------ 018 040 000 - 18 (Min/Max 12/40)
194 Temperature_Celsius -O---K 018 040 000 - 18 (Min/Max 12/40)
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 0/7672754
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
201 Unc_Soft_Read_Err_Rate --SRC- 120 120 000 - 0/3127793
204 Soft_ECC_Correct_Rate --SRC- 120 120 000 - 0/3127793
201 Unc_Soft_Read_Err_Rate --SRC- 120 120 000 - 0/7672754
204 Soft_ECC_Correct_Rate --SRC- 120 120 000 - 0/7672754
230 Life_Curve_Status PO--C- 100 100 000 - 100
231 SSD_Life_Left ------ 095 095 011 - 90194313217
233 SandForce_Internal -O--CK 000 000 000 - 8095
234 SandForce_Internal -O--CK 000 000 000 - 5159
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 5159
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 7473
244 Unknown_Attribute ------ 098 098 010 - 4587585
231 SSD_Life_Left ------ 094 094 011 - 90194313217
233 SandForce_Internal -O--CK 000 000 000 - 9071
234 SandForce_Internal -O--CK 000 000 000 - 5980
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 5980
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 7475
244 Unknown_Attribute ------ 098 098 010 - 5308486
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -131,9 +131,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
Device State: Active (0)
Current Temperature: 16 Celsius
Power Cycle Min/Max Temperature: 14/40 Celsius
Lifetime Min/Max Temperature: 14/40 Celsius
Current Temperature: 18 Celsius
Power Cycle Min/Max Temperature: 12/40 Celsius
Lifetime Min/Max Temperature: 12/40 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/85 Celsius
Temperature History Size (Index): 478 (67)
Temperature History Size (Index): 478 (271)
SCT Error Recovery Control command not supported
@@ -149,29 +149,29 @@ Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 7076 --- Lifetime Power-On Resets
0x01 0x010 4 7420 --- Power-on Hours
0x01 0x018 6 10820698526 --- Logical Sectors Written
0x01 0x028 6 15672762786 --- Logical Sectors Read
0x01 0x010 4 9527 --- Power-on Hours
0x01 0x018 6 12542733806 --- Logical Sectors Written
0x01 0x028 6 15677307747 --- Logical Sectors Read
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 16 --- Current Temperature
0x05 0x010 1 17 --- Average Short Term Temperature
0x05 0x018 1 17 --- Average Long Term Temperature
0x05 0x008 1 18 --- Current Temperature
0x05 0x010 1 16 --- Average Short Term Temperature
0x05 0x018 1 15 --- Average Long Term Temperature
0x05 0x020 1 40 --- Highest Temperature
0x05 0x028 1 15 --- Lowest Temperature
0x05 0x028 1 12 --- Lowest Temperature
0x05 0x030 1 33 --- Highest Average Short Term Temperature
0x05 0x038 1 15 --- Lowest Average Short Term Temperature
0x05 0x038 1 12 --- Lowest Average Short Term Temperature
0x05 0x040 1 28 --- Highest Average Long Term Temperature
0x05 0x048 1 17 --- Lowest Average Long Term Temperature
0x05 0x048 1 14 --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 0 --- Number of Hardware Resets
0x06 0x010 4 31353 --- Number of ASR Events
0x06 0x010 4 31368 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 2 --- Percentage Used Endurance Indicator
@@ -189,8 +189,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
0x0009 2 23 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 21 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC

View File

@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Jul 14 20:54:24 2023 EEST
Local Time is: Mon Jul 17 23:39:53 2023 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,7 +65,7 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O--CK 120 120 050 - 0/0
5 Retired_Block_Count PO--CK 100 100 003 - 0
9 Power_On_Hours_and_Msec -O--CK 061 061 000 - 34301h+38m+41.910s
9 Power_On_Hours_and_Msec -O--CK 061 061 000 - 34376h+21m+23.110s
12 Power_Cycle_Count -O--CK 098 098 000 - 2702
171 Program_Fail_Count -O-R-- 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
@@ -82,9 +82,9 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
204 Soft_ECC_Correct_Rate --SRC- 120 120 000 - 0/0
230 Life_Curve_Status PO--C- 100 100 000 - 100
231 SSD_Life_Left PO--C- 087 087 010 - 0
233 SandForce_Internal -O--CK 000 000 000 - 59667
234 SandForce_Internal -O--CK 000 000 000 - 41903
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 41903
233 SandForce_Internal -O--CK 000 000 000 - 59722
234 SandForce_Internal -O--CK 000 000 000 - 41957
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 41957
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 24399
||||||_ K auto-keep
|||||__ C event count
@@ -139,7 +139,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/85 Celsius
Temperature History Size (Index): 478 (142)
Temperature History Size (Index): 478 (113)
SCT Error Recovery Control command not supported
@@ -147,9 +147,9 @@ Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 2702 --- Lifetime Power-On Resets
0x01 0x010 4 34301 --- Power-on Hours
0x01 0x018 6 87878191436 --- Logical Sectors Written
0x01 0x028 6 51169212978 --- Logical Sectors Read
0x01 0x010 4 34376 --- Power-on Hours
0x01 0x018 6 87990653748 --- Logical Sectors Written
0x01 0x028 6 51169238832 --- Logical Sectors Read
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 2103 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion

View File

@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: In smartctl database 7.3/5528
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Dec 13 13:40:54 2024 CET
Local Time is: Fri Dec 20 23:27:48 2024 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -63,29 +63,29 @@ SCT capabilities: (0x0025) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O--CK 120 120 050 - 0/0
1 Raw_Read_Error_Rate -O--CK 094 094 050 - 2/2664722
5 Retired_Block_Count PO--CK 100 100 003 - 0
9 Power_On_Hours_and_Msec -O--CK 052 052 000 - 42584h+36m+45.450s
12 Power_Cycle_Count -O--CK 100 100 000 - 85
9 Power_On_Hours_and_Msec -O--CK 052 052 000 - 42615h+29m+47.020s
12 Power_Cycle_Count -O--CK 100 100 000 - 92
171 Program_Fail_Count -O-R-- 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 48
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 54
177 Wear_Range_Delta ------ 000 000 000 - 3
181 Program_Fail_Count -O-R-- 100 100 000 - 0
182 Erase_Fail_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--C- 100 100 000 - 0
189 Airflow_Temperature_Cel ------ 026 056 000 - 26 (Min/Max 20/56)
194 Temperature_Celsius -O---K 026 056 000 - 26 (Min/Max 20/56)
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 0/0
189 Airflow_Temperature_Cel ------ 037 056 000 - 37 (Min/Max 20/56)
194 Temperature_Celsius -O---K 037 056 000 - 37 (Min/Max 20/56)
195 ECC_Uncorr_Error_Count --SRC- 096 096 000 - 2/2664722
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
201 Unc_Soft_Read_Err_Rate --SRC- 120 120 000 - 0/0
204 Soft_ECC_Correct_Rate --SRC- 120 120 000 - 0/0
201 Unc_Soft_Read_Err_Rate --SRC- 096 096 000 - 2/2664722
204 Soft_ECC_Correct_Rate --SRC- 096 096 000 - 2/2664722
230 Life_Curve_Status PO--C- 100 100 000 - 100
231 SSD_Life_Left ------ 090 090 011 - 107374182400
233 SandForce_Internal -O--CK 000 000 000 - 66113
234 SandForce_Internal -O--CK 000 000 000 - 78518
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 78518
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 21245
233 SandForce_Internal -O--CK 000 000 000 - 66119
234 SandForce_Internal -O--CK 000 000 000 - 78521
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 78521
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 21247
244 Unknown_Attribute ------ 087 087 010 - 28901772
||||||_ K auto-keep
|||||__ C event count
@@ -130,7 +130,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
Device State: Active (0)
Current Temperature: 26 Celsius
Current Temperature: 37 Celsius
Power Cycle Min/Max Temperature: 20/56 Celsius
Lifetime Min/Max Temperature: 20/56 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -140,28 +140,28 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/85 Celsius
Temperature History Size (Index): 478 (426)
Temperature History Size (Index): 478 (140)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 85 --- Lifetime Power-On Resets
0x01 0x010 4 42584 --- Power-on Hours
0x01 0x018 6 164664812423 --- Logical Sectors Written
0x01 0x028 6 44554103011 --- Logical Sectors Read
0x01 0x008 4 92 --- Lifetime Power-On Resets
0x01 0x010 4 42615 --- Power-on Hours
0x01 0x018 6 164670569336 --- Logical Sectors Written
0x01 0x028 6 44559753176 --- Logical Sectors Read
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 89 --- Number of Reported Uncorrectable Errors
0x04 0x008 4 101 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 26 --- Current Temperature
0x05 0x010 1 30 --- Average Short Term Temperature
0x05 0x008 1 37 --- Current Temperature
0x05 0x010 1 36 --- Average Short Term Temperature
0x05 0x018 1 40 --- Average Long Term Temperature
0x05 0x020 1 56 --- Highest Temperature
0x05 0x028 1 24 --- Lowest Temperature
0x05 0x030 1 53 --- Highest Average Short Term Temperature
0x05 0x038 1 30 --- Lowest Average Short Term Temperature
0x05 0x038 1 29 --- Lowest Average Short Term Temperature
0x05 0x040 1 40 --- Highest Average Long Term Temperature
0x05 0x048 1 33 --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
@@ -170,7 +170,7 @@ Page Offset Size Value Flags Description
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 0 --- Number of Hardware Resets
0x06 0x010 4 665 --- Number of ASR Events
0x06 0x010 4 679 --- Number of ASR Events
0x06 0x018 4 4 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 12 --- Percentage Used Endurance Indicator
@@ -188,8 +188,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC

View File

@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Jul 14 20:54:24 2023 EEST
Local Time is: Mon Jul 17 23:39:53 2023 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,7 +65,7 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O--CK 120 120 050 - 0/0
5 Retired_Block_Count PO--CK 100 100 003 - 0
9 Power_On_Hours_and_Msec -O--CK 061 061 000 - 34341h+37m+51.960s
9 Power_On_Hours_and_Msec -O--CK 061 061 000 - 34416h+20m+27.430s
12 Power_Cycle_Count -O--CK 098 098 000 - 2704
171 Program_Fail_Count -O-R-- 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
@@ -82,9 +82,9 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
204 Soft_ECC_Correct_Rate --SRC- 120 120 000 - 0/0
230 Life_Curve_Status PO--C- 100 100 000 - 100
231 SSD_Life_Left PO--C- 095 095 010 - 1
233 SandForce_Internal -O--CK 000 000 000 - 29406
234 SandForce_Internal -O--CK 000 000 000 - 18699
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 18699
233 SandForce_Internal -O--CK 000 000 000 - 29460
234 SandForce_Internal -O--CK 000 000 000 - 18753
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 18753
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 24861
||||||_ K auto-keep
|||||__ C event count
@@ -147,9 +147,9 @@ Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 2704 --- Lifetime Power-On Resets
0x01 0x010 4 34341 --- Power-on Hours
0x01 0x018 6 39215554292 --- Logical Sectors Written
0x01 0x028 6 52138233548 --- Logical Sectors Read
0x01 0x010 4 34416 --- Power-on Hours
0x01 0x018 6 39328016604 --- Logical Sectors Written
0x01 0x028 6 52138260228 --- Logical Sectors Read
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 2091 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion

View File

@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: In smartctl database 7.3/5528
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Oct 27 12:45:05 2023 PDT
Local Time is: Wed Nov 8 14:55:18 2023 PST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,7 +65,7 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O--CK 120 120 050 - 2/0
5 Retired_Block_Count PO--CK 100 100 003 - 0
9 Power_On_Hours_and_Msec -O--CK 065 065 000 - 31137h+40m+22.110s
9 Power_On_Hours_and_Msec -O--CK 065 065 000 - 31428h+50m+28.770s
12 Power_Cycle_Count -O--CK 100 100 000 - 89
171 Program_Fail_Count -O-R-- 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
@@ -74,8 +74,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
181 Program_Fail_Count -O-R-- 100 100 000 - 0
182 Erase_Fail_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--C- 100 100 000 - 0
189 Airflow_Temperature_Cel ------ 035 057 000 - 35 (Min/Max 18/57)
194 Temperature_Celsius -O---K 035 057 000 - 35 (Min/Max 18/57)
189 Airflow_Temperature_Cel ------ 037 057 000 - 37 (Min/Max 18/57)
194 Temperature_Celsius -O---K 037 057 000 - 37 (Min/Max 18/57)
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 2/0
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
201 Unc_Soft_Read_Err_Rate --SRC- 120 120 000 - 2/0
@@ -130,7 +130,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
Device State: Active (0)
Current Temperature: 35 Celsius
Current Temperature: 37 Celsius
Power Cycle Min/Max Temperature: 18/57 Celsius
Lifetime Min/Max Temperature: 18/57 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -140,7 +140,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/85 Celsius
Temperature History Size (Index): 478 (169)
Temperature History Size (Index): 478 (176)
SCT Error Recovery Control command not supported
@@ -148,14 +148,14 @@ Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 89 --- Lifetime Power-On Resets
0x01 0x010 4 31137 --- Power-on Hours
0x01 0x010 4 31428 --- Power-on Hours
0x01 0x018 6 21232643871 --- Logical Sectors Written
0x01 0x028 6 15190245192 --- Logical Sectors Read
0x01 0x028 6 15190257507 --- Logical Sectors Read
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 116 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 35 --- Current Temperature
0x05 0x008 1 37 --- Current Temperature
0x05 0x010 1 38 --- Average Short Term Temperature
0x05 0x018 1 40 --- Average Long Term Temperature
0x05 0x020 1 56 --- Highest Temperature

View File

@@ -1,5 +1,5 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SandForce Driven SSDs
@@ -11,10 +11,10 @@ User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available
Device is: In smartctl database 7.3/5319
Device is: In smartctl database 7.3/5528
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Oct 28 12:49:58 2022 EDT
Local Time is: Sun Feb 11 02:49:11 2024 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -63,30 +63,30 @@ SCT capabilities: (0x0025) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O--CK 120 120 050 - 0/0
1 Raw_Read_Error_Rate -O--CK 095 095 050 - 0/7702182
5 Retired_Block_Count PO--CK 100 100 003 - 0
9 Power_On_Hours_and_Msec -O--CK 036 036 000 - 56130h+39m+54.560s
12 Power_Cycle_Count -O--CK 100 100 000 - 423
9 Power_On_Hours_and_Msec -O--CK 025 025 000 - 66211h+08m+03.750s
12 Power_Cycle_Count -O--CK 100 100 000 - 645
171 Program_Fail_Count -O-R-- 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 333
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 540
177 Wear_Range_Delta ------ 000 000 000 - 1
181 Program_Fail_Count -O-R-- 100 100 000 - 0
182 Erase_Fail_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--C- 100 100 000 - 0
189 Airflow_Temperature_Cel ------ 033 045 000 - 33 (Min/Max -19/45)
194 Temperature_Celsius -O---K 033 045 000 - 33 (Min/Max -19/45)
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 0/0
189 Airflow_Temperature_Cel ------ 035 045 000 - 35 (Min/Max -19/45)
194 Temperature_Celsius -O---K 035 045 000 - 35 (Min/Max -19/45)
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 0/7702182
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
201 Unc_Soft_Read_Err_Rate --SRC- 120 120 000 - 0/0
204 Soft_ECC_Correct_Rate --SRC- 120 120 000 - 0/0
201 Unc_Soft_Read_Err_Rate --SRC- 120 120 000 - 0/7702182
204 Soft_ECC_Correct_Rate --SRC- 120 120 000 - 0/7702182
230 Life_Curve_Status PO--C- 100 100 000 - 100
231 SSD_Life_Left ------ 092 092 011 - 0
233 SandForce_Internal -O--CK 000 000 000 - 46025
234 SandForce_Internal -O--CK 000 000 000 - 19690
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 19690
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 878
244 Unknown_Attribute ------ 089 089 010 - 22413654
231 SSD_Life_Left ------ 088 088 011 - 1
233 SandForce_Internal -O--CK 000 000 000 - 50807
234 SandForce_Internal -O--CK 000 000 000 - 23327
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 23327
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 1033
244 Unknown_Attribute ------ 088 088 010 - 23921005
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -133,7 +133,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
Device State: Active (0)
Current Temperature: 33 Celsius
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: -19/45 Celsius
Lifetime Min/Max Temperature: -19/45 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -143,38 +143,38 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/85 Celsius
Temperature History Size (Index): 478 (272)
Temperature History Size (Index): 478 (251)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 423 --- Lifetime Power-On Resets
0x01 0x010 4 56130 --- Power-on Hours
0x01 0x018 6 41294210122 --- Logical Sectors Written
0x01 0x028 6 1841607987 --- Logical Sectors Read
0x01 0x008 4 645 --- Lifetime Power-On Resets
0x01 0x010 4 66211 --- Power-on Hours
0x01 0x018 6 48920522373 --- Logical Sectors Written
0x01 0x028 6 2167526752 --- Logical Sectors Read
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 5017 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 33 --- Current Temperature
0x05 0x010 1 32 --- Average Short Term Temperature
0x05 0x018 1 28 --- Average Long Term Temperature
0x05 0x008 1 35 --- Current Temperature
0x05 0x010 1 33 --- Average Short Term Temperature
0x05 0x018 1 30 --- Average Long Term Temperature
0x05 0x020 1 45 --- Highest Temperature
0x05 0x028 1 20 --- Lowest Temperature
0x05 0x030 1 41 --- Highest Average Short Term Temperature
0x05 0x038 1 24 --- Lowest Average Short Term Temperature
0x05 0x040 1 38 --- Highest Average Long Term Temperature
0x05 0x048 1 28 --- Lowest Average Long Term Temperature
0x05 0x048 1 27 --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 0 --- Number of Hardware Resets
0x06 0x010 4 2706 --- Number of ASR Events
0x06 0x018 4 1113 --- Number of Interface CRC Errors
0x06 0x008 4 12 --- Number of Hardware Resets
0x06 0x010 4 3471 --- Number of ASR Events
0x06 0x018 4 1115 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 11 --- Percentage Used Endurance Indicator
|||_ C monitored condition met
@@ -191,8 +191,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x0009 2 33 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 24 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC

View File

@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: In smartctl database 7.3/5528
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Mar 8 09:26:05 2024 AEST
Local Time is: Sun Mar 10 14:45:58 2024 AEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,27 +65,27 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O--CK 120 120 050 - 0/0
5 Retired_Block_Count PO--CK 100 100 003 - 0
9 Power_On_Hours_and_Msec -O--CK 078 078 000 - 19319h+57m+47.230s
12 Power_Cycle_Count -O--CK 099 099 000 - 1980
9 Power_On_Hours_and_Msec -O--CK 078 078 000 - 19335h+22m+50.940s
12 Power_Cycle_Count -O--CK 099 099 000 - 1986
171 Program_Fail_Count -O-R-- 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 255
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 261
177 Wear_Range_Delta ------ 000 000 000 - 2
181 Program_Fail_Count -O-R-- 100 100 000 - 0
182 Erase_Fail_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--C- 100 100 000 - 0
189 Airflow_Temperature_Cel ------ 040 056 000 - 40 (Min/Max 9/56)
194 Temperature_Celsius -O---K 040 056 000 - 40 (Min/Max 9/56)
189 Airflow_Temperature_Cel ------ 029 056 000 - 29 (Min/Max 9/56)
194 Temperature_Celsius -O---K 029 056 000 - 29 (Min/Max 9/56)
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 0/0
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
201 Unc_Soft_Read_Err_Rate --SRC- 120 120 000 - 0/0
204 Soft_ECC_Correct_Rate --SRC- 120 120 000 - 0/0
230 Life_Curve_Status PO--C- 100 100 000 - 100
231 SSD_Life_Left PO--C- 094 094 010 - 21474836481
233 SandForce_Internal -O--CK 000 000 000 - 36177
234 SandForce_Internal -O--CK 000 000 000 - 56911
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 56911
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 8581
233 SandForce_Internal -O--CK 000 000 000 - 36185
234 SandForce_Internal -O--CK 000 000 000 - 56912
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 56912
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 8582
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -129,7 +129,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
Device State: Active (0)
Current Temperature: 40 Celsius
Current Temperature: 29 Celsius
Power Cycle Min/Max Temperature: 9/56 Celsius
Lifetime Min/Max Temperature: 9/61 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -139,22 +139,22 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/85 Celsius
Temperature History Size (Index): 478 (209)
Temperature History Size (Index): 478 (305)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 1980 --- Lifetime Power-On Resets
0x01 0x010 4 19319 --- Power-on Hours
0x01 0x018 6 119351355274 --- Logical Sectors Written
0x01 0x028 6 17997546990 --- Logical Sectors Read
0x01 0x008 4 1986 --- Lifetime Power-On Resets
0x01 0x010 4 19335 --- Power-on Hours
0x01 0x018 6 119354613474 --- Logical Sectors Written
0x01 0x028 6 17999347738 --- Logical Sectors Read
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x04 0x010 4 2 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 40 --- Current Temperature
0x05 0x008 1 29 --- Current Temperature
0x05 0x010 1 42 --- Average Short Term Temperature
0x05 0x018 1 26 --- Average Long Term Temperature
0x05 0x020 1 60 --- Highest Temperature
@@ -169,7 +169,7 @@ Page Offset Size Value Flags Description
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 14 --- Number of Hardware Resets
0x06 0x010 4 6500 --- Number of ASR Events
0x06 0x010 4 6689 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 4 --- Percentage Used Endurance Indicator

View File

@@ -1,5 +1,5 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p2 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SandForce Driven SSDs
@@ -11,10 +11,10 @@ User Capacity: 240,057,409,536 bytes [240 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available
Device is: In smartctl database 7.3/5319
Device is: In smartctl database 7.3/5528
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue May 10 22:42:46 2022 EEST
Local Time is: Sun Sep 3 20:16:04 2023 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -29,8 +29,8 @@ Wt Cache Reorder: Unavailable
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
@@ -65,28 +65,28 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O--CK 120 120 050 - 0/0
5 Retired_Block_Count PO--CK 100 100 003 - 0
9 Power_On_Hours_and_Msec -O--CK 087 087 000 - 12110h+03m+55.230s
12 Power_Cycle_Count -O--CK 098 098 000 - 2125
9 Power_On_Hours_and_Msec -O--CK 074 074 000 - 23644h+51m+51.350s
12 Power_Cycle_Count -O--CK 098 098 000 - 2142
171 Program_Fail_Count -O-R-- 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 970
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 987
177 Wear_Range_Delta ------ 000 000 000 - 1
181 Program_Fail_Count -O-R-- 100 100 000 - 0
182 Erase_Fail_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--C- 100 100 000 - 0
189 Airflow_Temperature_Cel ------ 034 043 000 - 34 (Min/Max 15/43)
194 Temperature_Celsius -O---K 034 043 000 - 34 (Min/Max 15/43)
189 Airflow_Temperature_Cel ------ 035 043 000 - 35 (Min/Max 15/43)
194 Temperature_Celsius -O---K 035 043 000 - 35 (Min/Max 15/43)
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 0/0
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
201 Unc_Soft_Read_Err_Rate --SRC- 120 120 000 - 0/0
204 Soft_ECC_Correct_Rate --SRC- 120 120 000 - 0/0
230 Life_Curve_Status PO--C- 100 100 000 - 100
231 SSD_Life_Left ------ 097 097 011 - 73014444033
233 SandForce_Internal -O--CK 000 000 000 - 34535
234 SandForce_Internal -O--CK 000 000 000 - 33272
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 33272
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 16610
244 Unknown_Attribute ------ 096 096 010 - 10354831
231 SSD_Life_Left ------ 094 094 011 - 73014444033
233 SandForce_Internal -O--CK 000 000 000 - 40404
234 SandForce_Internal -O--CK 000 000 000 - 37510
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 37510
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 16619
244 Unknown_Attribute ------ 095 095 010 - 11403423
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -114,7 +114,9 @@ SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log not supported
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 22804 -
# 2 Short offline Completed without error 00% 19253 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
@@ -130,7 +132,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
Device State: Active (0)
Current Temperature: 34 Celsius
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 15/43 Celsius
Lifetime Min/Max Temperature: 15/43 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -140,40 +142,40 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/85 Celsius
Temperature History Size (Index): 478 (220)
Temperature History Size (Index): 478 (344)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 2125 --- Lifetime Power-On Resets
0x01 0x010 4 12110 --- Power-on Hours
0x01 0x018 6 69778170074 --- Logical Sectors Written
0x01 0x028 6 34835359121 --- Logical Sectors Read
0x01 0x008 4 2142 --- Lifetime Power-On Resets
0x01 0x010 4 23644 --- Power-on Hours
0x01 0x018 6 78664889490 --- Logical Sectors Written
0x01 0x028 6 34852961352 --- Logical Sectors Read
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 124 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 34 --- Current Temperature
0x05 0x010 1 33 --- Average Short Term Temperature
0x05 0x018 1 28 --- Average Long Term Temperature
0x05 0x008 1 35 --- Current Temperature
0x05 0x010 1 35 --- Average Short Term Temperature
0x05 0x018 1 32 --- Average Long Term Temperature
0x05 0x020 1 43 --- Highest Temperature
0x05 0x028 1 17 --- Lowest Temperature
0x05 0x030 1 36 --- Highest Average Short Term Temperature
0x05 0x038 1 18 --- Lowest Average Short Term Temperature
0x05 0x040 1 28 --- Highest Average Long Term Temperature
0x05 0x040 1 33 --- Highest Average Long Term Temperature
0x05 0x048 1 22 --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 203 --- Number of Hardware Resets
0x06 0x010 4 3635 --- Number of ASR Events
0x06 0x008 4 241 --- Number of Hardware Resets
0x06 0x010 4 3728 --- Number of ASR Events
0x06 0x018 4 2 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 4 --- Percentage Used Endurance Indicator
0x07 0x008 1 5 --- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
@@ -188,8 +190,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
0x0009 2 15 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 16 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC