1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 35, modified: 3308)

This commit is contained in:
Andrey Ponomarenko
2025-01-05 02:37:11 +03:00
parent f68c38aa35
commit 8c515ea896
3343 changed files with 73552 additions and 65384 deletions

View File

@@ -1,4 +1,4 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p3 amd64] (local build)
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p8 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: Not in smartctl database 7.3/5319
ATA Version is: ACS-3 T13/2161-D revision 4
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Dec 2 02:48:47 2022 EST
Local Time is: Sat Jul 29 13:22:11 2023 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -62,13 +62,13 @@ SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours PO--CK 100 100 010 - 1691
12 Power_Cycle_Count PO--CK 100 100 010 - 31
9 Power_On_Hours PO--CK 100 100 010 - 7422
12 Power_Cycle_Count PO--CK 100 100 010 - 41
161 Unknown_Attribute PO--CK 100 100 010 - 0
164 Unknown_Attribute PO--CK 100 100 010 - 35965
165 Unknown_Attribute PO--CK 100 100 010 - 79
164 Unknown_Attribute PO--CK 100 100 010 - 97693
165 Unknown_Attribute PO--CK 100 100 010 - 209
166 Unknown_Attribute PO--CK 100 100 010 - 0
167 Unknown_Attribute PO--CK 100 100 010 - 75
167 Unknown_Attribute PO--CK 100 100 010 - 205
169 Unknown_Attribute PO--CK 100 100 010 - 0
176 Erase_Fail_Count_Chip PO--CK 100 100 010 - 0
177 Wear_Leveling_Count PO--CK 100 100 010 - 0
@@ -77,8 +77,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
194 Temperature_Celsius PO--CK 100 100 010 - 48
195 Hardware_ECC_Recovered PO--CK 100 100 010 - 0
199 UDMA_CRC_Error_Count PO--CK 100 100 010 - 0
241 Total_LBAs_Written PO--CK 100 100 010 - 2352
242 Total_LBAs_Read PO--CK 100 100 010 - 44
241 Total_LBAs_Written PO--CK 100 100 010 - 10351
242 Total_LBAs_Read PO--CK 100 100 010 - 100
243 Unknown_Attribute PO--CK 100 100 010 - 0
244 Unknown_Attribute PO--CK 100 100 010 - 0
245 Unknown_Attribute PO--CK 100 100 010 - 0

View File

@@ -1,4 +1,4 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: Not in smartctl database 7.3/5528
ATA Version is: ACS-3 T13/2161-D revision 4
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Dec 13 08:50:27 2023 UTC
Local Time is: Sat May 11 16:39:54 2024 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -62,13 +62,13 @@ SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours PO--CK 100 100 010 - 5
12 Power_Cycle_Count PO--CK 100 100 010 - 13
9 Power_On_Hours PO--CK 100 100 010 - 3017
12 Power_Cycle_Count PO--CK 100 100 010 - 91
161 Unknown_Attribute PO--CK 100 100 010 - 0
164 Unknown_Attribute PO--CK 100 100 010 - 949
165 Unknown_Attribute PO--CK 100 100 010 - 3
164 Unknown_Attribute PO--CK 100 100 010 - 15128
165 Unknown_Attribute PO--CK 100 100 010 - 61
166 Unknown_Attribute PO--CK 100 100 010 - 0
167 Unknown_Attribute PO--CK 100 100 010 - 1
167 Unknown_Attribute PO--CK 100 100 010 - 31
169 Unknown_Attribute PO--CK 100 100 010 - 0
176 Erase_Fail_Count_Chip PO--CK 100 100 010 - 0
177 Wear_Leveling_Count PO--CK 100 100 010 - 0
@@ -77,8 +77,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
194 Temperature_Celsius PO--CK 100 100 010 - 48
195 Hardware_ECC_Recovered PO--CK 100 100 010 - 0
199 UDMA_CRC_Error_Count PO--CK 100 100 010 - 0
241 Total_LBAs_Written PO--CK 100 100 010 - 128
242 Total_LBAs_Read PO--CK 100 100 010 - 1
241 Total_LBAs_Written PO--CK 100 100 010 - 2980
242 Total_LBAs_Read PO--CK 100 100 010 - 96
243 Unknown_Attribute PO--CK 100 100 010 - 0
244 Unknown_Attribute PO--CK 100 100 010 - 0
245 Unknown_Attribute PO--CK 100 100 010 - 0

View File

@@ -1,5 +1,5 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: SHAREVDI 128GB SSD
@@ -11,10 +11,10 @@ User Capacity: 128,035,676,160 bytes [128 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available
Device is: Not in smartctl database 7.3/5319
Device is: Not in smartctl database 7.3/5528
ATA Version is: ACS-3 T13/2161-D revision 4
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Jun 23 20:52:13 2023 EDT
Local Time is: Sun Jul 21 21:01:15 2024 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -62,13 +62,13 @@ SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours PO--CK 100 100 010 - 7893
12 Power_Cycle_Count PO--CK 100 100 010 - 39
9 Power_On_Hours PO--CK 100 100 010 - 17332
12 Power_Cycle_Count PO--CK 100 100 010 - 49
161 Unknown_Attribute PO--CK 100 100 010 - 0
164 Unknown_Attribute PO--CK 100 100 010 - 80260
165 Unknown_Attribute PO--CK 100 100 010 - 173
164 Unknown_Attribute PO--CK 100 100 010 - 174989
165 Unknown_Attribute PO--CK 100 100 010 - 371
166 Unknown_Attribute PO--CK 100 100 010 - 0
167 Unknown_Attribute PO--CK 100 100 010 - 167
167 Unknown_Attribute PO--CK 100 100 010 - 366
169 Unknown_Attribute PO--CK 100 100 010 - 0
176 Erase_Fail_Count_Chip PO--CK 100 100 010 - 0
177 Wear_Leveling_Count PO--CK 100 100 010 - 0
@@ -77,8 +77,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
194 Temperature_Celsius PO--CK 100 100 010 - 48
195 Hardware_ECC_Recovered PO--CK 100 100 010 - 0
199 UDMA_CRC_Error_Count PO--CK 100 100 010 - 0
241 Total_LBAs_Written PO--CK 100 100 010 - 6960
242 Total_LBAs_Read PO--CK 100 100 010 - 36
241 Total_LBAs_Written PO--CK 100 100 010 - 30273
242 Total_LBAs_Read PO--CK 100 100 010 - 62
243 Unknown_Attribute PO--CK 100 100 010 - 0
244 Unknown_Attribute PO--CK 100 100 010 - 0
245 Unknown_Attribute PO--CK 100 100 010 - 0

View File

@@ -1,5 +1,5 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p5 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p5 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: SHAREVDI 128GB SSD
@@ -11,10 +11,10 @@ User Capacity: 128,035,676,160 bytes [128 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available
Device is: Not in smartctl database 7.3/5319
Device is: Not in smartctl database 7.3/5528
ATA Version is: ACS-3 T13/2161-D revision 4
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Jan 24 20:36:44 2023 CET
Local Time is: Tue Nov 28 17:41:41 2023 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -62,13 +62,13 @@ SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours PO--CK 100 100 010 - 621
12 Power_Cycle_Count PO--CK 100 100 010 - 62
9 Power_On_Hours PO--CK 100 100 010 - 7866
12 Power_Cycle_Count PO--CK 100 100 010 - 136
161 Unknown_Attribute PO--CK 100 100 010 - 0
164 Unknown_Attribute PO--CK 100 100 010 - 9812
165 Unknown_Attribute PO--CK 100 100 010 - 46
166 Unknown_Attribute PO--CK 100 100 010 - 2
167 Unknown_Attribute PO--CK 100 100 010 - 20
164 Unknown_Attribute PO--CK 100 100 010 - 117438
165 Unknown_Attribute PO--CK 100 100 010 - 266
166 Unknown_Attribute PO--CK 100 100 010 - 197
167 Unknown_Attribute PO--CK 100 100 010 - 250
169 Unknown_Attribute PO--CK 100 100 010 - 0
176 Erase_Fail_Count_Chip PO--CK 100 100 010 - 0
177 Wear_Leveling_Count PO--CK 100 100 010 - 0
@@ -77,8 +77,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
194 Temperature_Celsius PO--CK 100 100 010 - 48
195 Hardware_ECC_Recovered PO--CK 100 100 010 - 0
199 UDMA_CRC_Error_Count PO--CK 100 100 010 - 0
241 Total_LBAs_Written PO--CK 100 100 010 - 723
242 Total_LBAs_Read PO--CK 100 100 010 - 12
241 Total_LBAs_Written PO--CK 100 100 010 - 14831
242 Total_LBAs_Read PO--CK 100 100 010 - 352
243 Unknown_Attribute PO--CK 100 100 010 - 0
244 Unknown_Attribute PO--CK 100 100 010 - 0
245 Unknown_Attribute PO--CK 100 100 010 - 0

View File

@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: Not in smartctl database 7.3/5528
ATA Version is: ACS-3 T13/2161-D revision 4
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Aug 30 20:21:24 2023 UTC
Local Time is: Wed Sep 6 21:04:11 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -62,13 +62,13 @@ SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours PO--CK 100 100 010 - 6682
9 Power_On_Hours PO--CK 100 100 010 - 6850
12 Power_Cycle_Count PO--CK 100 100 010 - 110
161 Unknown_Attribute PO--CK 100 100 010 - 0
164 Unknown_Attribute PO--CK 100 100 010 - 87920
165 Unknown_Attribute PO--CK 100 100 010 - 201
164 Unknown_Attribute PO--CK 100 100 010 - 89460
165 Unknown_Attribute PO--CK 100 100 010 - 205
166 Unknown_Attribute PO--CK 100 100 010 - 144
167 Unknown_Attribute PO--CK 100 100 010 - 186
167 Unknown_Attribute PO--CK 100 100 010 - 189
169 Unknown_Attribute PO--CK 100 100 010 - 0
176 Erase_Fail_Count_Chip PO--CK 100 100 010 - 0
177 Wear_Leveling_Count PO--CK 100 100 010 - 0
@@ -77,8 +77,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
194 Temperature_Celsius PO--CK 100 100 010 - 48
195 Hardware_ECC_Recovered PO--CK 100 100 010 - 0
199 UDMA_CRC_Error_Count PO--CK 100 100 010 - 0
241 Total_LBAs_Written PO--CK 100 100 010 - 9522
242 Total_LBAs_Read PO--CK 100 100 010 - 1988
241 Total_LBAs_Written PO--CK 100 100 010 - 9911
242 Total_LBAs_Read PO--CK 100 100 010 - 1992
243 Unknown_Attribute PO--CK 100 100 010 - 0
244 Unknown_Attribute PO--CK 100 100 010 - 0
245 Unknown_Attribute PO--CK 100 100 010 - 0

View File

@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: Not in smartctl database 7.3/5528
ATA Version is: ACS-3 T13/2161-D revision 4
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Sep 27 10:06:59 2023 CDT
Local Time is: Wed Sep 27 13:33:20 2023 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -62,10 +62,10 @@ SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours PO--CK 100 100 010 - 2374
9 Power_On_Hours PO--CK 100 100 010 - 2377
12 Power_Cycle_Count PO--CK 100 100 010 - 71
161 Unknown_Attribute PO--CK 100 100 010 - 0
164 Unknown_Attribute PO--CK 100 100 010 - 51948
164 Unknown_Attribute PO--CK 100 100 010 - 51988
165 Unknown_Attribute PO--CK 100 100 010 - 123
166 Unknown_Attribute PO--CK 100 100 010 - 0
167 Unknown_Attribute PO--CK 100 100 010 - 106
@@ -77,7 +77,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
194 Temperature_Celsius PO--CK 100 100 010 - 48
195 Hardware_ECC_Recovered PO--CK 100 100 010 - 0
199 UDMA_CRC_Error_Count PO--CK 100 100 010 - 0
241 Total_LBAs_Written PO--CK 100 100 010 - 2477
241 Total_LBAs_Written PO--CK 100 100 010 - 2480
242 Total_LBAs_Read PO--CK 100 100 010 - 21
243 Unknown_Attribute PO--CK 100 100 010 - 0
244 Unknown_Attribute PO--CK 100 100 010 - 0

View File

@@ -1,5 +1,5 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p5 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: SHAREVDI 128GB SSD
@@ -11,10 +11,10 @@ User Capacity: 128,035,676,160 bytes [128 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available
Device is: Not in smartctl database 7.3/5319
Device is: Not in smartctl database 7.3/5528
ATA Version is: ACS-3 T13/2161-D revision 4
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Feb 6 23:17:41 2023 CET
Local Time is: Thu Mar 21 22:15:08 2024 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -32,8 +32,9 @@ General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 16) The self-test routine was aborted by
the host.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
@@ -61,13 +62,13 @@ SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours PO--CK 100 100 010 - 3
9 Power_On_Hours PO--CK 100 100 010 - 9817
12 Power_Cycle_Count PO--CK 100 100 010 - 13
161 Unknown_Attribute PO--CK 100 100 010 - 0
164 Unknown_Attribute PO--CK 100 100 010 - 886
165 Unknown_Attribute PO--CK 100 100 010 - 3
166 Unknown_Attribute PO--CK 100 100 010 - 1
167 Unknown_Attribute PO--CK 100 100 010 - 1
164 Unknown_Attribute PO--CK 100 100 010 - 90208
165 Unknown_Attribute PO--CK 100 100 010 - 222
166 Unknown_Attribute PO--CK 100 100 010 - 106
167 Unknown_Attribute PO--CK 100 100 010 - 189
169 Unknown_Attribute PO--CK 100 100 010 - 0
176 Erase_Fail_Count_Chip PO--CK 100 100 010 - 0
177 Wear_Leveling_Count PO--CK 100 100 010 - 0
@@ -76,8 +77,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
194 Temperature_Celsius PO--CK 100 100 010 - 48
195 Hardware_ECC_Recovered PO--CK 100 100 010 - 0
199 UDMA_CRC_Error_Count PO--CK 100 100 010 - 0
241 Total_LBAs_Written PO--CK 100 100 010 - 121
242 Total_LBAs_Read PO--CK 100 100 010 - 0
241 Total_LBAs_Written PO--CK 100 100 010 - 3345
242 Total_LBAs_Read PO--CK 100 100 010 - 8
243 Unknown_Attribute PO--CK 100 100 010 - 0
244 Unknown_Attribute PO--CK 100 100 010 - 0
245 Unknown_Attribute PO--CK 100 100 010 - 0
@@ -113,7 +114,8 @@ SMART Error Log not supported
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Aborted by host 00% 1 -
# 1 Short offline Completed without error 00% 6283 -
# 2 Short offline Aborted by host 00% 1 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS

View File

@@ -1,4 +1,4 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p3 amd64] (local build)
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p4 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: Not in smartctl database 7.3/5528
ATA Version is: ACS-3 T13/2161-D revision 4
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Aug 30 12:40:25 2024 BST
Local Time is: Sat Sep 28 11:17:44 2024 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -62,13 +62,13 @@ SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours PO--CK 100 100 010 - 11907
12 Power_Cycle_Count PO--CK 100 100 010 - 75
9 Power_On_Hours PO--CK 100 100 010 - 12601
12 Power_Cycle_Count PO--CK 100 100 010 - 77
161 Unknown_Attribute PO--CK 100 100 010 - 0
164 Unknown_Attribute PO--CK 100 100 010 - 478154
165 Unknown_Attribute PO--CK 100 100 010 - 1077
164 Unknown_Attribute PO--CK 100 100 010 - 497691
165 Unknown_Attribute PO--CK 100 100 010 - 1117
166 Unknown_Attribute PO--CK 100 100 010 - 0
167 Unknown_Attribute PO--CK 100 100 010 - 1015
167 Unknown_Attribute PO--CK 100 100 010 - 1056
169 Unknown_Attribute PO--CK 100 100 010 - 0
176 Erase_Fail_Count_Chip PO--CK 100 100 010 - 0
177 Wear_Leveling_Count PO--CK 100 100 010 - 0
@@ -77,8 +77,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
194 Temperature_Celsius PO--CK 100 100 010 - 48
195 Hardware_ECC_Recovered PO--CK 100 100 010 - 0
199 UDMA_CRC_Error_Count PO--CK 100 100 010 - 0
241 Total_LBAs_Written PO--CK 100 100 010 - 18974
242 Total_LBAs_Read PO--CK 100 100 010 - 1824
241 Total_LBAs_Written PO--CK 100 100 010 - 19902
242 Total_LBAs_Read PO--CK 100 100 010 - 1828
243 Unknown_Attribute PO--CK 100 100 010 - 0
244 Unknown_Attribute PO--CK 100 100 010 - 0
245 Unknown_Attribute PO--CK 100 100 010 - 0