smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Fujitsu MHZ BJ
|
||||
Device Model: FUJITSU MHZ2250BJ FFS G2
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00000e ...
|
||||
Firmware Version: 0085001C
|
||||
User Capacity: 250,059,350,016 bytes [250 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 3f
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Tue Mar 22 10:32:56 2022 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 254
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 812) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 111) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 046 - 74827
|
||||
3 Spin_Up_Time PO---- 100 100 025 - 2
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 024 - 0 (2000 0)
|
||||
9 Power_On_Minutes -O--CK 066 066 000 - 17086h+44m
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 2016
|
||||
191 G-Sense_Error_Rate -O--C- 100 100 000 - 463
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 55
|
||||
193 Load_Cycle_Count -O--CK 095 095 000 - 249108210344
|
||||
194 Temperature_Celsius -O---K 100 090 000 - 29 (Min/Max 10/62)
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 148022252
|
||||
200 Multi_Zone_Error_Rate -O--CK 100 100 000 - 357648420
|
||||
240 Head_Flying_Hours -O--CK 100 100 000 - 983031
|
||||
241 Total_LBAs_Written -O--CK 100 100 000 - 19301918179332
|
||||
242 Total_LBAs_Read -O--CK 100 100 000 - 74234330349572
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 58
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 64 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 2 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 1 Device vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (2 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 17085 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 0 (0x0000)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/29 Celsius
|
||||
Lifetime Min/Max Temperature: 10/62 Celsius
|
||||
Specified Max Operating Temperature: 43 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 5/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 478 (475)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x0002 4 0 R_ERR response for data FIS
|
||||
0x0003 4 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 4 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 4 0 R_ERR response for non-data FIS
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0008 4 0 Device-to-host non-data FIS retries
|
||||
0x0009 4 95 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
|
Reference in New Issue