1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 314, modified: 0)

This commit is contained in:
Andrey Ponomarenko
2023-01-13 16:10:49 +03:00
parent b1c41e7edc
commit 98c1dfb7c8
314 changed files with 53747 additions and 0 deletions

View File

@@ -0,0 +1,68 @@
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.1-RELEASE-p22-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: ATP NVMe M.2 2280 SSD
Serial Number: --
Firmware Version: 42A4SB6B
PCI Vendor/Subsystem ID: 0x1db2
IEEE OUI Identifier: 0x141357
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 240,057,409,536 [240 GB]
Namespace 1 Utilization: 3,924,115,456 [3.92 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 141357 ...
Local Time is: Thu Apr 7 20:37:40 2022 CEST
Firmware Updates (0x14): 2 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0b): S/H_per_NS Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 75 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 9.00W - - 0 0 0 0 0 0
1 + 4.60W - - 1 1 1 1 0 0
2 + 3.80W - - 2 2 2 2 0 0
3 - 0.0450W - - 3 3 3 3 2000 2000
4 - 0.0040W - - 4 4 4 4 15000 15000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 37 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 3%
Data Units Read: 3,337 [1.70 GB]
Data Units Written: 4,992,454 [2.55 TB]
Host Read Commands: 143,445
Host Write Commands: 221,666,984
Controller Busy Time: 848
Power Cycles: 85
Power On Hours: 2,753
Unsafe Shutdowns: 13
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 37 Celsius
Temperature Sensor 2: 37 Celsius
Temperature Sensor 3: 44 Celsius
Temperature Sensor 4: 37 Celsius
Temperature Sensor 5: 37 Celsius
Temperature Sensor 6: 33 Celsius
Error Information (NVMe Log 0x01, 16 of 256 entries)
No Errors Logged

View File

@@ -0,0 +1,70 @@
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.1-RELEASE-p22-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: ATP NVMe M.2 2280 SSD
Serial Number: --
Firmware Version: 42A4SB6B
PCI Vendor/Subsystem ID: 0x1db2
IEEE OUI Identifier: 0x141357
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 240,057,409,536 [240 GB]
Namespace 1 Utilization: 3,911,192,576 [3.91 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 141357 ...
Local Time is: Thu Apr 7 20:37:40 2022 CEST
Firmware Updates (0x14): 2 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0b): S/H_per_NS Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 75 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 9.00W - - 0 0 0 0 0 0
1 + 4.60W - - 1 1 1 1 0 0
2 + 3.80W - - 2 2 2 2 0 0
3 - 0.0450W - - 3 3 3 3 2000 2000
4 - 0.0040W - - 4 4 4 4 15000 15000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 35 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 3%
Data Units Read: 4,863 [2.48 GB]
Data Units Written: 4,992,454 [2.55 TB]
Host Read Commands: 145,318
Host Write Commands: 216,847,154
Controller Busy Time: 851
Power Cycles: 84
Power On Hours: 2,750
Unsafe Shutdowns: 13
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 39 Celsius
Temperature Sensor 2: 35 Celsius
Temperature Sensor 3: 47 Celsius
Temperature Sensor 4: 35 Celsius
Temperature Sensor 5: 35 Celsius
Temperature Sensor 6: 35 Celsius
Error Information (NVMe Log 0x01, 16 of 256 entries)
No Errors Logged