mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 314, modified: 0)
This commit is contained in:
195
SSD/Transcend/TS128/TS128GMTS830S/B90C2797250C
Normal file
195
SSD/Transcend/TS128/TS128GMTS830S/B90C2797250C
Normal file
@@ -0,0 +1,195 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: TS128GMTS830S
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 7c3548 ...
|
||||
Firmware Version: R0427GN1
|
||||
User Capacity: 128,035,676,160 bytes [128 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: M.2
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: Not in smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Apr 6 08:27:10 2022 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 30) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 725
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 36
|
||||
148 Unknown_Attribute ------ 100 100 000 - 23007
|
||||
149 Unknown_Attribute ------ 100 100 000 - 1551
|
||||
150 Unknown_Attribute ------ 100 100 000 - 1432
|
||||
151 Unknown_Attribute ------ 100 100 000 - 1533
|
||||
159 Unknown_Attribute ------ 100 100 000 - 0
|
||||
160 Unknown_Attribute ------ 100 100 000 - 0
|
||||
161 Unknown_Attribute ------ 100 100 000 - 32
|
||||
163 Unknown_Attribute ------ 100 100 000 - 25
|
||||
164 Unknown_Attribute ------ 100 100 000 - 53969
|
||||
165 Unknown_Attribute ------ 100 100 000 - 132
|
||||
166 Unknown_Attribute ------ 100 100 000 - 46
|
||||
167 Unknown_Attribute ------ 100 100 000 - 117
|
||||
168 Unknown_Attribute ------ 100 100 000 - 1500
|
||||
169 Unknown_Attribute ------ 100 100 000 - 93
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 16
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 17
|
||||
194 Temperature_Celsius ------ 100 100 000 - 52
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 0
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Total_LBAs_Written ------ 100 100 000 - 146746
|
||||
242 Total_LBAs_Read ------ 100 100 000 - 961
|
||||
245 Unknown_Attribute ------ 100 100 000 - 485721
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x24 GPL R/O 88 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 64 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Completed [00% left] (0-65535)
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 36 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 725 --- Power-on Hours
|
||||
0x01 0x018 6 1027260452 --- Logical Sectors Written
|
||||
0x01 0x020 6 79221270 --- Number of Write Commands
|
||||
0x01 0x028 6 62983611 --- Logical Sectors Read
|
||||
0x01 0x030 6 1367753 --- Number of Read Commands
|
||||
0x01 0x038 6 4294967296 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 17 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 52 --- Current Temperature
|
||||
0x05 0x010 1 49 --- Average Short Term Temperature
|
||||
0x05 0x018 1 49 --- Average Long Term Temperature
|
||||
0x05 0x020 1 58 --- Highest Temperature
|
||||
0x05 0x028 1 0 --- Lowest Temperature
|
||||
0x05 0x030 1 51 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 48 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 51 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 48 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 49 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 971 --- Number of Hardware Resets
|
||||
0x06 0x010 4 91 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 7 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 27 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
|
151
SSD/Transcend/TS240/TS240GSSD220S/521E3A54058C
Normal file
151
SSD/Transcend/TS240/TS240GSSD220S/521E3A54058C
Normal file
@@ -0,0 +1,151 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS240GSSD220S
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 7c3548 ...
|
||||
Firmware Version: R0510A0
|
||||
User Capacity: 240,057,409,536 bytes [240 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 T13/2015-D revision 3
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Mar 24 11:56:50 2022 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 120) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x11) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
No Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 10) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate -O--CK 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct -O--CK 100 100 050 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 050 - 44
|
||||
12 Power_Cycle_Count -O--CK 100 100 050 - 22
|
||||
160 Uncorrectable_Error_Cnt -O--CK 100 100 050 - 0
|
||||
161 Valid_Spare_Block_Cnt PO--CK 100 100 050 - 100
|
||||
163 Initial_Bad_Block_Count -O--CK 100 100 050 - 24
|
||||
164 Total_Erase_Count -O--CK 100 100 050 - 114
|
||||
165 Max_Erase_Count -O--CK 100 100 050 - 1
|
||||
166 Min_Erase_Count -O--CK 100 100 050 - 0
|
||||
167 Average_Erase_Count -O--CK 100 100 050 - 0
|
||||
168 Max_Erase_Count_of_Spec -O--CK 100 100 050 - 1500
|
||||
169 Remaining_Lifetime_Perc -O--CK 100 100 050 - 100
|
||||
175 Program_Fail_Count_Chip -O--CK 100 100 050 - 0
|
||||
176 Erase_Fail_Count_Chip -O--CK 100 100 050 - 0
|
||||
177 Wear_Leveling_Count -O--CK 100 100 050 - 0
|
||||
178 Runtime_Invalid_Blk_Cnt -O--CK 100 100 050 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 050 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 050 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 050 - 16
|
||||
194 Temperature_Celsius -O---K 100 100 050 - 42
|
||||
195 Hardware_ECC_Recovered -O--CK 100 100 050 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 050 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 050 - 0
|
||||
198 Offline_Uncorrectable -O--CK 100 100 050 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 050 - 0
|
||||
232 Available_Reservd_Space -O--CK 100 100 050 - 100
|
||||
241 Host_Writes_32MiB ----CK 100 100 050 - 631
|
||||
242 Host_Reads_32MiB ----CK 100 100 050 - 7280
|
||||
245 TLC_Writes_32MiB -O--CK 100 100 050 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xde GPL VS 8 Device vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 0 -
|
||||
# 2 Short offline Completed without error 00% 0 -
|
||||
|
||||
Selective Self-tests/Logging not supported
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 22 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 44 --- Power-on Hours
|
||||
0x01 0x018 6 41414840 --- Logical Sectors Written
|
||||
0x01 0x020 6 349107 --- Number of Write Commands
|
||||
0x01 0x028 6 477102247 --- Logical Sectors Read
|
||||
0x01 0x030 6 47508 --- Number of Read Commands
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x0002 4 0 R_ERR response for data FIS
|
||||
0x0005 4 0 R_ERR response for non-data FIS
|
||||
0x000a 4 2 Device-to-host register FISes sent due to a COMRESET
|
||||
|
162
SSD/Transcend/TS256/TS256GMSA452T2/9659A3992436
Normal file
162
SSD/Transcend/TS256/TS256GMSA452T2/9659A3992436
Normal file
@@ -0,0 +1,162 @@
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: TS256GMSA452T2
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 7c3548 ...
|
||||
Firmware Version: 02J0T4GB
|
||||
User Capacity: 256,060,514,304 bytes [256 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Mar 20 23:41:10 2022 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 22
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 15
|
||||
148 Unknown_Attribute ------ 100 100 000 - 1913
|
||||
149 Unknown_Attribute ------ 100 100 000 - 28
|
||||
150 Unknown_Attribute ------ 100 100 000 - 0
|
||||
151 Unknown_Attribute ------ 100 100 000 - 20
|
||||
164 Unknown_Attribute ------ 100 100 000 - 222
|
||||
165 Unknown_Attribute ------ 100 100 000 - 4
|
||||
166 Unknown_Attribute ------ 100 100 000 - 0
|
||||
167 Unknown_Attribute ------ 100 100 000 - 0
|
||||
159 Unknown_Attribute ------ 100 100 000 - 0
|
||||
160 Unknown_Attribute ------ 100 100 000 - 0
|
||||
161 Unknown_Attribute ------ 100 100 000 - 138
|
||||
163 Unknown_Attribute ------ 100 100 000 - 16
|
||||
168 Unknown_Attribute ------ 100 100 000 - 3000
|
||||
169 Unknown_Attribute ------ 100 100 000 - 100
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 7
|
||||
194 Temperature_Celsius ------ 100 100 000 - 51 (Min/Max 21/63)
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 0
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Total_LBAs_Written ------ 100 100 000 - 2414
|
||||
242 Total_LBAs_Read ------ 100 100 000 - 183
|
||||
245 Unknown_Attribute ------ 100 100 000 - 3868
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x24 GPL R/O 88 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 64 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 0 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was never started
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 15 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 22 --- Power-on Hours
|
||||
0x01 0x018 6 158234258 --- Logical Sectors Written
|
||||
0x01 0x020 6 2507787 --- Number of Write Commands
|
||||
0x01 0x028 6 12040861 --- Logical Sectors Read
|
||||
0x01 0x030 6 300561 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 7 --- Resets Between Cmd Acceptance and Completion
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 1339 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
162
SSD/Transcend/TS256/TS256GMTS952T2/92D0C512CFD0
Normal file
162
SSD/Transcend/TS256/TS256GMTS952T2/92D0C512CFD0
Normal file
@@ -0,0 +1,162 @@
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.1-RELEASE-p22-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: TS256GMTS952T2
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 7c3548 ...
|
||||
Firmware Version: 02J0T4GB
|
||||
User Capacity: 256,060,514,304 bytes [256 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Apr 6 14:08:00 2022 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 0
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 6
|
||||
148 Unknown_Attribute ------ 100 100 000 - 231
|
||||
149 Unknown_Attribute ------ 100 100 000 - 4
|
||||
150 Unknown_Attribute ------ 100 100 000 - 0
|
||||
151 Unknown_Attribute ------ 100 100 000 - 2
|
||||
164 Unknown_Attribute ------ 100 100 000 - 47
|
||||
165 Unknown_Attribute ------ 100 100 000 - 2
|
||||
166 Unknown_Attribute ------ 100 100 000 - 0
|
||||
167 Unknown_Attribute ------ 100 100 000 - 0
|
||||
159 Unknown_Attribute ------ 100 100 000 - 0
|
||||
160 Unknown_Attribute ------ 100 100 000 - 0
|
||||
161 Unknown_Attribute ------ 100 100 000 - 143
|
||||
163 Unknown_Attribute ------ 100 100 000 - 9
|
||||
168 Unknown_Attribute ------ 100 100 000 - 3000
|
||||
169 Unknown_Attribute ------ 100 100 000 - 100
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 2
|
||||
194 Temperature_Celsius ------ 100 100 000 - 55 (Min/Max 21/55)
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 0
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Total_LBAs_Written ------ 100 100 000 - 327
|
||||
242 Total_LBAs_Read ------ 100 100 000 - 47
|
||||
245 Unknown_Attribute ------ 100 100 000 - 558
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x24 GPL R/O 88 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 64 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 0 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was never started
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 6 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 0 --- Power-on Hours
|
||||
0x01 0x018 6 21462055 --- Logical Sectors Written
|
||||
0x01 0x020 6 196878 --- Number of Write Commands
|
||||
0x01 0x028 6 3100345 --- Logical Sectors Read
|
||||
0x01 0x030 6 34220 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 2 --- Resets Between Cmd Acceptance and Completion
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 315 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
162
SSD/Transcend/TS256/TS256GMTS952T2/B8A35D463E61
Normal file
162
SSD/Transcend/TS256/TS256GMTS952T2/B8A35D463E61
Normal file
@@ -0,0 +1,162 @@
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.1-RELEASE-p22-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: TS256GMTS952T2
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 7c3548 ...
|
||||
Firmware Version: 02J0T4GB
|
||||
User Capacity: 256,060,514,304 bytes [256 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Mar 24 19:01:02 2022 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 2
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 8
|
||||
148 Unknown_Attribute ------ 100 100 000 - 628
|
||||
149 Unknown_Attribute ------ 100 100 000 - 10
|
||||
150 Unknown_Attribute ------ 100 100 000 - 0
|
||||
151 Unknown_Attribute ------ 100 100 000 - 6
|
||||
164 Unknown_Attribute ------ 100 100 000 - 84
|
||||
165 Unknown_Attribute ------ 100 100 000 - 4
|
||||
166 Unknown_Attribute ------ 100 100 000 - 0
|
||||
167 Unknown_Attribute ------ 100 100 000 - 0
|
||||
159 Unknown_Attribute ------ 100 100 000 - 0
|
||||
160 Unknown_Attribute ------ 100 100 000 - 0
|
||||
161 Unknown_Attribute ------ 100 100 000 - 121
|
||||
163 Unknown_Attribute ------ 100 100 000 - 23
|
||||
168 Unknown_Attribute ------ 100 100 000 - 3000
|
||||
169 Unknown_Attribute ------ 100 100 000 - 100
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 2
|
||||
194 Temperature_Celsius ------ 100 100 000 - 65 (Min/Max 20/68)
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 0
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Total_LBAs_Written ------ 100 100 000 - 784
|
||||
242 Total_LBAs_Read ------ 100 100 000 - 84
|
||||
245 Unknown_Attribute ------ 100 100 000 - 1320
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x24 GPL R/O 88 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 64 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 0 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was never started
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 8 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2 --- Power-on Hours
|
||||
0x01 0x018 6 51432207 --- Logical Sectors Written
|
||||
0x01 0x020 6 589220 --- Number of Write Commands
|
||||
0x01 0x028 6 5525941 --- Logical Sectors Read
|
||||
0x01 0x030 6 86282 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 2 --- Resets Between Cmd Acceptance and Completion
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 555 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
163
SSD/Transcend/TS32/TS32GMSA370/38A14C6318C7
Normal file
163
SSD/Transcend/TS32/TS32GMSA370/38A14C6318C7
Normal file
@@ -0,0 +1,163 @@
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS32GMSA370
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 7c3548 ...
|
||||
Firmware Version: P1225CH1
|
||||
User Capacity: 32,017,047,552 bytes [32.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Mar 23 15:04:19 2022 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 1082
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 92
|
||||
160 Uncorrectable_Error_Cnt ------ 100 100 000 - 0
|
||||
161 Valid_Spare_Block_Cnt ------ 100 100 000 - 44
|
||||
163 Initial_Bad_Block_Count ------ 100 100 000 - 0
|
||||
164 Total_Erase_Count ------ 100 100 000 - 65694
|
||||
165 Max_Erase_Count ------ 100 100 000 - 111
|
||||
166 Min_Erase_Count ------ 100 100 000 - 10
|
||||
167 Average_Erase_Count ------ 100 100 000 - 64
|
||||
168 Max_Erase_Count_of_Spec ------ 100 100 000 - 3000
|
||||
169 Remaining_Lifetime_Perc ------ 100 100 000 - 98
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 110
|
||||
178 Runtime_Invalid_Blk_Cnt ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 13
|
||||
194 Temperature_Celsius ------ 100 100 000 - 46
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 0
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Host_Writes_32MiB ------ 100 100 000 - 52016
|
||||
242 Host_Reads_32MiB ------ 100 100 000 - 4265
|
||||
245 TLC_Writes_32MiB ------ 100 100 000 - 65694
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was never started
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 92 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1082 --- Power-on Hours
|
||||
0x01 0x018 6 3408950648 --- Logical Sectors Written
|
||||
0x01 0x020 6 61902050 --- Number of Write Commands
|
||||
0x01 0x028 6 279561797 --- Logical Sectors Read
|
||||
0x01 0x030 6 10930100 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 13 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 7229 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 2 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
162
SSD/Transcend/TS512/TS512GMTS952T2/7FB8BE6C3577
Normal file
162
SSD/Transcend/TS512/TS512GMTS952T2/7FB8BE6C3577
Normal file
@@ -0,0 +1,162 @@
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: TS512GMTS952T2
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 7c3548 ...
|
||||
Firmware Version: 02J0T4GB
|
||||
User Capacity: 512,110,190,592 bytes [512 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Mar 21 21:45:03 2022 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 96
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 21
|
||||
148 Unknown_Attribute ------ 100 100 000 - 801
|
||||
149 Unknown_Attribute ------ 100 100 000 - 15
|
||||
150 Unknown_Attribute ------ 100 100 000 - 0
|
||||
151 Unknown_Attribute ------ 100 100 000 - 8
|
||||
164 Unknown_Attribute ------ 100 100 000 - 93
|
||||
165 Unknown_Attribute ------ 100 100 000 - 4
|
||||
166 Unknown_Attribute ------ 100 100 000 - 0
|
||||
167 Unknown_Attribute ------ 100 100 000 - 0
|
||||
159 Unknown_Attribute ------ 100 100 000 - 0
|
||||
160 Unknown_Attribute ------ 100 100 000 - 0
|
||||
161 Unknown_Attribute ------ 100 100 000 - 125
|
||||
163 Unknown_Attribute ------ 100 100 000 - 27
|
||||
168 Unknown_Attribute ------ 100 100 000 - 3000
|
||||
169 Unknown_Attribute ------ 100 100 000 - 100
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 17
|
||||
194 Temperature_Celsius ------ 100 100 000 - 67 (Min/Max 22/97)
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 0
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Total_LBAs_Written ------ 100 100 000 - 1910
|
||||
242 Total_LBAs_Read ------ 100 100 000 - 126
|
||||
245 Unknown_Attribute ------ 100 100 000 - 3240
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x24 GPL R/O 88 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 64 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 0 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was never started
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 21 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 96 --- Power-on Hours
|
||||
0x01 0x018 6 125215464 --- Logical Sectors Written
|
||||
0x01 0x020 6 1714030 --- Number of Write Commands
|
||||
0x01 0x028 6 8281184 --- Logical Sectors Read
|
||||
0x01 0x030 6 208449 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 17 --- Resets Between Cmd Acceptance and Completion
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 709 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
163
SSD/Transcend/TS64/TS64GMSA230S/734F8DD4B728
Normal file
163
SSD/Transcend/TS64/TS64GMSA230S/734F8DD4B728
Normal file
@@ -0,0 +1,163 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS64GMSA230S
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 7c3548 ...
|
||||
Firmware Version: 02J0TBD1
|
||||
User Capacity: 64,023,257,088 bytes [64.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Mar 27 13:16:35 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 2263
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 17
|
||||
148 Total_SLC_Erase_Ct ------ 100 100 000 - 263818
|
||||
149 Max_SLC_Erase_Ct ------ 100 100 000 - 4204
|
||||
150 Min_SLC_Erase_Ct ------ 100 100 000 - 4019
|
||||
151 Average_SLC_Erase_Ct ------ 100 100 000 - 4187
|
||||
164 Total_Erase_Count ------ 100 100 000 - 52193
|
||||
165 Max_Erase_Count ------ 100 100 000 - 68
|
||||
166 Min_Erase_Count ------ 100 100 000 - 4
|
||||
167 Average_Erase_Count ------ 100 100 000 - 57
|
||||
159 DRAM_1_Bit_Error_Count ------ 100 100 000 - 0
|
||||
160 Uncorrectable_Error_Cnt ------ 100 100 000 - 0
|
||||
161 Valid_Spare_Block_Cnt ------ 100 100 000 - 53
|
||||
163 Initial_Bad_Block_Count ------ 100 100 000 - 15
|
||||
168 Max_Erase_Count_of_Spec ------ 100 100 000 - 3000
|
||||
169 Remaining_Lifetime_Perc ------ 100 100 000 - 99
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 128
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 8
|
||||
194 Temperature_Celsius ------ 100 100 000 - 56 (Min/Max 16/71)
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 0
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Host_Writes_32MiB ------ 100 100 000 - 175367
|
||||
242 Host_Reads_32MiB ------ 100 100 000 - 2479
|
||||
245 TLC_Writes_32MiB ------ 100 100 000 - 315297
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x24 GPL R/O 88 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 64 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 0 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was never started
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 17 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2263 --- Power-on Hours
|
||||
0x01 0x018 6 11492911735 --- Logical Sectors Written
|
||||
0x01 0x020 6 149114796 --- Number of Write Commands
|
||||
0x01 0x028 6 162466162 --- Logical Sectors Read
|
||||
0x01 0x030 6 1937811 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 8 --- Resets Between Cmd Acceptance and Completion
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 149 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 1 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
162
SSD/Transcend/TS64/TS64GSSD370/11F4419B47E4
Normal file
162
SSD/Transcend/TS64/TS64GSSD370/11F4419B47E4
Normal file
@@ -0,0 +1,162 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS64GSSD370
|
||||
Serial Number: --
|
||||
Firmware Version: N1126KB
|
||||
User Capacity: 64,023,257,088 bytes [64.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Mar 29 13:13:26 2022 KST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 7072
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 94
|
||||
160 Uncorrectable_Error_Cnt ------ 100 100 000 - 0
|
||||
161 Valid_Spare_Block_Cnt ------ 100 100 000 - 45
|
||||
163 Initial_Bad_Block_Count ------ 100 100 000 - 23
|
||||
164 Total_Erase_Count ------ 100 100 000 - 742114
|
||||
165 Max_Erase_Count ------ 100 100 000 - 782
|
||||
166 Min_Erase_Count ------ 100 100 000 - 682
|
||||
167 Average_Erase_Count ------ 100 100 000 - 728
|
||||
168 Max_Erase_Count_of_Spec ------ 100 100 000 - 3000
|
||||
169 Remaining_Lifetime_Perc ------ 100 100 000 - 76
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 1447
|
||||
178 Runtime_Invalid_Blk_Cnt ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 27
|
||||
194 Temperature_Celsius ------ 100 100 000 - 53
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 1823
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Host_Writes_32MiB ------ 100 100 000 - 323112
|
||||
242 Host_Reads_32MiB ------ 100 100 000 - 4881
|
||||
245 TLC_Writes_32MiB ------ 100 100 000 - 1484228
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was never started
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 94 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 7072 --- Power-on Hours
|
||||
0x01 0x018 6 3995624596 --- Logical Sectors Written
|
||||
0x01 0x020 6 557197136 --- Number of Write Commands
|
||||
0x01 0x028 6 319937469 --- Logical Sectors Read
|
||||
0x01 0x030 6 2863152 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 27 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 209 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 24 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
162
SSD/Transcend/TS64/TS64GSSD370/B9F142407E27
Normal file
162
SSD/Transcend/TS64/TS64GSSD370/B9F142407E27
Normal file
@@ -0,0 +1,162 @@
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS64GSSD370
|
||||
Serial Number: --
|
||||
Firmware Version: O0918B
|
||||
User Capacity: 64,023,257,088 bytes [64.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Mar 20 08:20:37 2022 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 7802
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 48
|
||||
160 Uncorrectable_Error_Cnt ------ 100 100 000 - 0
|
||||
161 Valid_Spare_Block_Cnt ------ 100 100 000 - 54
|
||||
163 Initial_Bad_Block_Count ------ 100 100 000 - 14
|
||||
164 Total_Erase_Count ------ 100 100 000 - 1234547
|
||||
165 Max_Erase_Count ------ 100 100 000 - 1253
|
||||
166 Min_Erase_Count ------ 100 100 000 - 1152
|
||||
167 Average_Erase_Count ------ 100 100 000 - 1202
|
||||
168 Max_Erase_Count_of_Spec ------ 100 100 000 - 3000
|
||||
169 Remaining_Lifetime_Perc ------ 100 100 000 - 60
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 3735
|
||||
178 Runtime_Invalid_Blk_Cnt ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 17
|
||||
194 Temperature_Celsius ------ 100 100 000 - 40
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 2871
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Host_Writes_32MiB ------ 100 100 000 - 636987
|
||||
242 Host_Reads_32MiB ------ 100 100 000 - 113201
|
||||
245 TLC_Writes_32MiB ------ 100 100 000 - 2469094
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was never started
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 48 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 7802 --- Power-on Hours
|
||||
0x01 0x018 6 3090913158 --- Logical Sectors Written
|
||||
0x01 0x020 6 744776305 --- Number of Write Commands
|
||||
0x01 0x028 6 3123828045 --- Logical Sectors Read
|
||||
0x01 0x030 6 150344726 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 17 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 211 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 40 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
162
SSD/Transcend/TS64/TS64GSSD370S/F327FE63B112
Normal file
162
SSD/Transcend/TS64/TS64GSSD370S/F327FE63B112
Normal file
@@ -0,0 +1,162 @@
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS64GSSD370S
|
||||
Serial Number: --
|
||||
Firmware Version: O0724D
|
||||
User Capacity: 64,023,257,088 bytes [64.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat Mar 19 16:03:51 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 2540
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 47
|
||||
160 Uncorrectable_Error_Cnt ------ 100 100 000 - 0
|
||||
161 Valid_Spare_Block_Cnt ------ 100 100 000 - 49
|
||||
163 Initial_Bad_Block_Count ------ 100 100 000 - 19
|
||||
164 Total_Erase_Count ------ 100 100 000 - 390946
|
||||
165 Max_Erase_Count ------ 100 100 000 - 433
|
||||
166 Min_Erase_Count ------ 100 100 000 - 333
|
||||
167 Average_Erase_Count ------ 100 100 000 - 382
|
||||
168 Max_Erase_Count_of_Spec ------ 100 100 000 - 3000
|
||||
169 Remaining_Lifetime_Perc ------ 100 100 000 - 88
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 290
|
||||
178 Runtime_Invalid_Blk_Cnt ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 22
|
||||
194 Temperature_Celsius ------ 100 100 000 - 37
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 1737392
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 339
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Host_Writes_32MiB ------ 100 100 000 - 643920
|
||||
242 Host_Reads_32MiB ------ 100 100 000 - 1537
|
||||
245 TLC_Writes_32MiB ------ 100 100 000 - 781892
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was never started
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 47 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2540 --- Power-on Hours
|
||||
0x01 0x018 6 3545245095 --- Logical Sectors Written
|
||||
0x01 0x020 6 653545609 --- Number of Write Commands
|
||||
0x01 0x028 6 100761706 --- Logical Sectors Read
|
||||
0x01 0x030 6 2721318 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 22 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 5290 --- Number of Hardware Resets
|
||||
0x06 0x018 4 339 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 12 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
Reference in New Issue
Block a user