mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 110)
This commit is contained in:
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon Feb 1 04:40:11 2021 GMT
|
||||
Local Time is: Tue Feb 9 01:32:38 2021 GMT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,22 +65,22 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--K 100 100 040 - 0
|
||||
3 Spin_Up_Time PO---K 239 100 033 - 1
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 3070
|
||||
3 Spin_Up_Time PO---K 238 100 033 - 1
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 3081
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 208 (0 25)
|
||||
7 Seek_Error_Rate POSR-K 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--K 100 100 040 - 0
|
||||
9 Power_On_Hours -O--CK 057 057 000 - 18914
|
||||
9 Power_On_Hours -O--CK 057 057 000 - 19100
|
||||
10 Spin_Retry_Count PO--CK 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 3061
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 3072
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 665724780545
|
||||
188 Command_Timeout -O--CK 100 100 000 - 8591572992
|
||||
190 Airflow_Temperature_Cel -O---K 062 047 045 - 38 (Min/Max 30/44)
|
||||
191 G-Sense_Error_Rate -O--CK 097 097 000 - 961
|
||||
190 Airflow_Temperature_Cel -O---K 066 047 045 - 34 (Min/Max 32/35)
|
||||
191 G-Sense_Error_Rate -O--CK 097 097 000 - 966
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 11927734
|
||||
193 Load_Cycle_Count -O--CK 032 032 000 - 681859
|
||||
193 Load_Cycle_Count -O--CK 032 032 000 - 688848
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 25
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
@@ -145,14 +145,17 @@ Error 1 [0] occurred at disk power-on lifetime: 18717 hours (779 days + 21 hours
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 18324 -
|
||||
# 2 Extended offline Completed without error 00% 17414 -
|
||||
# 3 Short offline Completed without error 00% 16751 -
|
||||
# 4 Short offline Completed without error 00% 16557 -
|
||||
# 5 Short offline Completed without error 00% 8196 -
|
||||
# 6 Extended offline Completed without error 00% 5144 -
|
||||
# 7 Short offline Completed without error 00% 3512 -
|
||||
# 8 Short offline Completed without error 00% 4 -
|
||||
# 1 Extended offline Completed without error 00% 19043 -
|
||||
# 2 Extended offline Aborted by host 90% 19041 -
|
||||
# 3 Short offline Completed without error 00% 19039 -
|
||||
# 4 Extended offline Completed without error 00% 18324 -
|
||||
# 5 Extended offline Completed without error 00% 17414 -
|
||||
# 6 Short offline Completed without error 00% 16751 -
|
||||
# 7 Short offline Completed without error 00% 16557 -
|
||||
# 8 Short offline Completed without error 00% 8196 -
|
||||
# 9 Extended offline Completed without error 00% 5144 -
|
||||
#10 Short offline Completed without error 00% 3512 -
|
||||
#11 Short offline Completed without error 00% 4 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -168,8 +171,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/44 Celsius
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/35 Celsius
|
||||
Lifetime Min/Max Temperature: 10/53 Celsius
|
||||
Specified Max Operating Temperature: 34 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -179,7 +182,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (67)
|
||||
Temperature History Size (Index): 128 (64)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -198,8 +201,10 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 19 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 18 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 15 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
||||
|
Reference in New Issue
Block a user