1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 0, modified: 110)

This commit is contained in:
Andrey Ponomarenko
2023-05-01 23:15:02 +03:00
parent f3c4ef82ea
commit a6ae3b9b7d
110 changed files with 2280 additions and 2376 deletions

View File

@@ -1,4 +1,4 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Jun 6 07:27:16 2022 EDT
Local Time is: Sat Sep 3 06:07:37 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -62,23 +62,23 @@ SCT capabilities: (0x103b) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 118 099 006 - 186934216
1 Raw_Read_Error_Rate POSR-K 115 099 006 - 99876626
3 Spin_Up_Time PO---K 100 100 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 341
4 Start_Stop_Count -O--CK 100 100 020 - 345
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 2
7 Seek_Error_Rate POSR-K 087 060 030 - 506463312
9 Power_On_Hours -O--CK 087 087 000 - 11561
7 Seek_Error_Rate POSR-K 087 060 030 - 631263913
9 Power_On_Hours -O--CK 085 085 000 - 13696
10 Spin_Retry_Count PO--CK 100 100 097 - 0
12 Power_Cycle_Count -O--CK 100 100 020 - 182
12 Power_Cycle_Count -O--CK 100 100 020 - 186
180 Unknown_HDD_Attribute PO-R-K 100 100 000 - 4294967295
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 100 000 - 0
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 061 055 045 - 39 (Min/Max 39/41)
190 Airflow_Temperature_Cel -O---K 061 055 045 - 39 (Min/Max 38/42)
194 Temperature_Celsius -O---K 039 045 000 - 39 (0 13 0 0 0)
195 Hardware_ECC_Recovered -O-RCK 037 024 000 - 186934216
195 Hardware_ECC_Recovered -O-RCK 045 024 000 - 99876626
196 Reallocated_Event_Count -O--CK 100 100 036 - 2
197 Current_Pending_Sector -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
@@ -138,7 +138,7 @@ SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
Device State: Active (0)
Current Temperature: 39 Celsius
Power Cycle Min/Max Temperature: 39/41 Celsius
Power Cycle Min/Max Temperature: 38/42 Celsius
Lifetime Min/Max Temperature: 13/45 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -147,7 +147,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 59 minutes
Min/Max recommended Temperature: 14/55 Celsius
Min/Max Temperature Limit: 10/60 Celsius
Temperature History Size (Index): 128 (13)
Temperature History Size (Index): 128 (15)
SCT Error Recovery Control:
Read: Disabled
@@ -159,7 +159,7 @@ Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 13 Device-to-host register FISes sent due to a COMRESET
0x000a 2 53 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS

View File

@@ -1,4 +1,4 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p20-HBSD amd64] (local build)
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.1-RELEASE-p21-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Sat Nov 6 00:53:00 2021 EDT
Local Time is: Tue Dec 21 22:26:49 2021 EST
==> WARNING: A firmware update for this drive may be available,
see the following Seagate web pages:
@@ -70,28 +70,28 @@ SCT capabilities: (0x103f) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 112 099 006 - 161461669
1 Raw_Read_Error_Rate POSR-- 117 099 006 - 141022530
3 Spin_Up_Time PO---- 097 097 000 - 0
4 Start_Stop_Count -O--CK 037 037 020 - 65535
5 Reallocated_Sector_Ct PO--CK 099 099 036 - 44
7 Seek_Error_Rate POSR-- 087 060 030 - 560104442
9 Power_On_Hours -O--CK 046 046 000 - 47343
5 Reallocated_Sector_Ct PO--CK 053 053 036 - 1935
7 Seek_Error_Rate POSR-- 087 060 030 - 599241534
9 Power_On_Hours -O--CK 045 045 000 - 48444
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 044 044 020 - 57658
12 Power_Cycle_Count -O--CK 044 044 020 - 57671
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error -O--CK 100 100 099 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 098 000 - 6
189 High_Fly_Writes -O-RCK 084 084 000 - 16
190 Airflow_Temperature_Cel -O---K 070 048 045 - 30 (Min/Max 28/40)
194 Temperature_Celsius -O---K 030 052 000 - 30 (0 7 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 027 020 000 - 161461669
190 Airflow_Temperature_Cel -O---K 075 048 045 - 25 (Min/Max 24/27)
194 Temperature_Celsius -O---K 025 052 000 - 25 (0 7 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 033 020 000 - 141022530
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
240 Head_Flying_Hours ------ 100 253 000 - 189329 (107 187 0)
241 Total_LBAs_Written ------ 100 253 000 - 1941591735
242 Total_LBAs_Read ------ 100 253 000 - 1444141801
240 Head_Flying_Hours ------ 100 253 000 - 190464 (187 36 0)
241 Total_LBAs_Written ------ 100 253 000 - 141533763
242 Total_LBAs_Read ------ 100 253 000 - 3514991211
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -156,8 +156,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
Device State: Active (0)
Current Temperature: 30 Celsius
Power Cycle Min/Max Temperature: 28/40 Celsius
Current Temperature: 25 Celsius
Power Cycle Min/Max Temperature: 24/27 Celsius
Lifetime Min/Max Temperature: 7/52 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -166,7 +166,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 59 minutes
Min/Max recommended Temperature: 14/55 Celsius
Min/Max Temperature Limit: 10/60 Celsius
Temperature History Size (Index): 128 (73)
Temperature History Size (Index): 128 (52)
SCT Error Recovery Control:
Read: Disabled
@@ -178,7 +178,7 @@ Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 11 Device-to-host register FISes sent due to a COMRESET
0x000a 2 15 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS