1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 0, modified: 110)

This commit is contained in:
Andrey Ponomarenko
2023-05-01 23:15:02 +03:00
parent f3c4ef82ea
commit a6ae3b9b7d
110 changed files with 2280 additions and 2376 deletions

View File

@@ -14,7 +14,7 @@ TRIM Command: Available
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Jul 24 13:01:07 2022 EDT
Local Time is: Sun Jul 31 10:21:26 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -66,23 +66,23 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 098 098 000 - 9079
12 Power_Cycle_Count -O--CK 098 098 000 - 2008
9 Power_On_Hours -O--CK 098 098 000 - 9244
12 Power_Cycle_Count -O--CK 098 098 000 - 2010
170 Unused_Rsvd_Blk_Ct_Chip -O--CK 100 100 010 - 0
171 Program_Fail_Count_Chip -O--CK 100 100 010 - 0
172 Erase_Fail_Count_Chip -O--CK 100 100 010 - 0
173 Wear_Leveling_Count PO--CK 003 003 005 NOW 2060
173 Wear_Leveling_Count PO--CK 001 001 005 NOW 2159
174 Unexpect_Power_Loss_Ct -O--CK 099 099 000 - 57
178 Used_Rsvd_Blk_Cnt_Chip PO--C- 100 100 010 - 0
180 Unused_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 768
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
194 Temperature_Celsius -O--CK 072 059 000 - 28
194 Temperature_Celsius -O--CK 074 059 000 - 26
199 CRC_Error_Count -OSRCK 100 100 000 - 0
233 Media_Wearout_Indicator PO--C- 001 001 000 - 216172781610467
241 Total_LBAs_Written -O--CK 099 099 000 - 55889
242 Total_LBAs_Read -O--CK 099 099 000 - 6080
249 NAND_Writes_1GiB -O--CK 099 099 000 - 527584
233 Media_Wearout_Indicator PO--C- 001 001 000 - 216172780779995
241 Total_LBAs_Written -O--CK 099 099 000 - 57492
242 Total_LBAs_Read -O--CK 099 099 000 - 6082
249 NAND_Writes_1GiB -O--CK 099 099 000 - 552944
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -132,7 +132,7 @@ SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: SCT command executing in background (5)
Current Temperature: 26 Celsius
Power Cycle Min/Max Temperature: 23/40 Celsius
Power Cycle Min/Max Temperature: 25/40 Celsius
Lifetime Min/Max Temperature: 0/70 Celsius
Under/Over Temperature Limit Count: 4294967295/4294901760
SMART Status: 0xffff (Reserved)
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (13)
Temperature History Size (Index): 128 (38)
SCT Error Recovery Control:
Read: Disabled
@@ -162,8 +162,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC