mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 262)
This commit is contained in:
@@ -10,7 +10,7 @@ User Capacity: 80,000,000,000 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Thu Nov 21 08:54:50 2024 CST
|
||||
Local Time is: Tue Dec 3 13:15:50 2024 CST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 128 (quiet), recommended: 128
|
||||
@@ -63,14 +63,14 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
|
||||
3 Spin_Up_Time PO---- 202 165 021 - 866
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 323
|
||||
3 Spin_Up_Time PO---- 196 165 021 - 1175
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 325
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 95345
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 95624
|
||||
10 Spin_Retry_Count PO--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 319
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 320
|
||||
190 Airflow_Temperature_Cel -O---K 067 040 045 Past 33
|
||||
194 Temperature_Celsius -O---K 110 083 000 - 33
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
@@ -128,7 +128,7 @@ SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: --/47 Celsius
|
||||
Power Cycle Min/Max Temperature: --/38 Celsius
|
||||
Lifetime Min/Max Temperature: --/65 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -136,7 +136,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/65 Celsius
|
||||
Min/Max Temperature Limit: 1/70 Celsius
|
||||
Temperature History Size (Index): 128 (126)
|
||||
Temperature History Size (Index): 128 (85)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -149,6 +149,6 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 128514 Vendor specific
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 4242 Vendor specific
|
||||
|
||||
|
@@ -10,7 +10,7 @@ User Capacity: 80,000,000,000 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Sat Apr 9 15:39:45 2022 EDT
|
||||
Local Time is: Sat Apr 9 21:38:42 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -18,7 +18,7 @@ APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
@@ -63,14 +63,14 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
|
||||
3 Spin_Up_Time PO---- 178 160 021 - 2083
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1785
|
||||
3 Spin_Up_Time PO---- 177 160 021 - 2108
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1786
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 8871
|
||||
10 Spin_Retry_Count PO--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1780
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1781
|
||||
190 Airflow_Temperature_Cel -O---K 078 040 045 Past 22
|
||||
194 Temperature_Celsius -O---K 121 083 000 - 22
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
@@ -135,7 +135,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/65 Celsius
|
||||
Min/Max Temperature Limit: 1/70 Celsius
|
||||
Temperature History Size (Index): 128 (63)
|
||||
Temperature History Size (Index): 128 (70)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -149,5 +149,5 @@ SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 68 Vendor specific
|
||||
0x8000 4 63 Vendor specific
|
||||
|
||||
|
Reference in New Issue