smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SAMSUNG SpinPoint P80
|
||||
Device Model: SAMSUNG SP0812C
|
||||
Serial Number: --
|
||||
Firmware Version: SU100-32
|
||||
User Capacity: 80,026,361,856 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 T13/1532D revision 0
|
||||
Local Time is: Sun Mar 6 16:23:46 2022 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Unavailable
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 22) The self-test routine was aborted by
|
||||
the host.
|
||||
Total time to complete Offline
|
||||
data collection: ( 3000) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x1b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
No Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
No General Purpose Logging support.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 50) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0
|
||||
3 Spin_Up_Time POS--- 100 100 025 - 4160
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 636
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 011 - 0
|
||||
7 Seek_Error_Rate POSR-- 100 100 051 - 0
|
||||
8 Seek_Time_Performance P-S--K 100 100 015 - 0
|
||||
9 Power_On_Half_Minutes -O--CK 099 099 000 - 5622h+14m
|
||||
10 Spin_Retry_Count PO--CK 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 367
|
||||
194 Temperature_Celsius -O---K 124 061 000 - 38
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 72346
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Total_Offl_Uncorrectabl ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate -O-R-- 100 100 051 - 0
|
||||
201 Soft_Read_Error_Rate -O-R-- 100 100 051 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory not supported
|
||||
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 2 Comprehensive SMART error log
|
||||
0x06 SL R/O 2 SMART self-test log
|
||||
0x80-0x9f SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log Version: 1
|
||||
ATA Error Count: 541 (device log contains only the most recent five errors)
|
||||
CR = Command Register [HEX]
|
||||
FR = Features Register [HEX]
|
||||
SC = Sector Count Register [HEX]
|
||||
SN = Sector Number Register [HEX]
|
||||
CL = Cylinder Low Register [HEX]
|
||||
CH = Cylinder High Register [HEX]
|
||||
DH = Device/Head Register [HEX]
|
||||
DC = Device Command Register [HEX]
|
||||
ER = Error register [HEX]
|
||||
ST = Status register [HEX]
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 541 occurred at disk power-on lifetime: 5620 hours (234 days + 4 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
04 51 00 00 00 00 a0
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
f5 00 00 00 00 00 a0 00 00:01:53.813 SECURITY FREEZE LOCK
|
||||
ef 02 00 00 00 00 a0 00 00:01:53.813 SET FEATURES [Enable write cache]
|
||||
ef aa 00 00 00 00 a0 00 00:01:53.813 SET FEATURES [Enable read look-ahead]
|
||||
ef 03 45 00 00 00 a0 00 00:01:53.813 SET FEATURES [Set transfer mode]
|
||||
ef 03 22 00 00 00 a0 00 00:01:53.813 SET FEATURES [Set transfer mode]
|
||||
|
||||
Error 540 occurred at disk power-on lifetime: 5620 hours (234 days + 4 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
04 51 00 00 00 00 a0
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
f5 00 00 00 00 00 a0 00 00:01:53.063 SECURITY FREEZE LOCK
|
||||
ef 02 00 00 00 00 a0 00 00:01:53.063 SET FEATURES [Enable write cache]
|
||||
ef aa 00 00 00 00 a0 00 00:01:53.063 SET FEATURES [Enable read look-ahead]
|
||||
ef 03 45 00 00 00 a0 00 00:01:53.063 SET FEATURES [Set transfer mode]
|
||||
ef 03 22 00 00 00 a0 00 00:01:53.063 SET FEATURES [Set transfer mode]
|
||||
|
||||
Error 539 occurred at disk power-on lifetime: 5620 hours (234 days + 4 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
04 51 00 00 00 00 a0
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
f5 00 00 00 00 00 a0 00 01:32:54.313 SECURITY FREEZE LOCK
|
||||
ef 02 00 00 00 00 a0 00 01:32:54.313 SET FEATURES [Enable write cache]
|
||||
ef aa 00 00 00 00 a0 00 01:32:54.313 SET FEATURES [Enable read look-ahead]
|
||||
ef 03 45 00 00 00 a0 00 01:32:54.313 SET FEATURES [Set transfer mode]
|
||||
ef 03 22 00 00 00 a0 00 01:32:54.313 SET FEATURES [Set transfer mode]
|
||||
|
||||
Error 538 occurred at disk power-on lifetime: 5619 hours (234 days + 3 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
04 51 00 00 00 00 a0
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
f5 00 00 00 00 00 a0 00 00:14:53.688 SECURITY FREEZE LOCK
|
||||
ef 02 00 00 00 00 a0 00 00:14:53.688 SET FEATURES [Enable write cache]
|
||||
ef aa 00 00 00 00 a0 00 00:14:53.688 SET FEATURES [Enable read look-ahead]
|
||||
ef 03 45 00 00 00 a0 00 00:14:53.688 SET FEATURES [Set transfer mode]
|
||||
ef 03 22 00 00 00 a0 00 00:14:53.688 SET FEATURES [Set transfer mode]
|
||||
|
||||
Error 537 occurred at disk power-on lifetime: 5619 hours (234 days + 3 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
04 51 00 00 00 00 a0
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
f5 00 00 00 00 00 a0 00 00:02:10.250 SECURITY FREEZE LOCK
|
||||
ef 02 00 00 00 00 a0 00 00:02:10.250 SET FEATURES [Enable write cache]
|
||||
ef aa 00 00 00 00 a0 00 00:02:10.250 SET FEATURES [Enable read look-ahead]
|
||||
ef 03 45 00 00 00 a0 00 00:02:10.250 SET FEATURES [Set transfer mode]
|
||||
ef 03 22 00 00 00 a0 00 00:02:10.250 SET FEATURES [Set transfer mode]
|
||||
|
||||
SMART Extended Self-test Log (GP Log 0x07) not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||