mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 3637, modified: 0)
This commit is contained in:
169
HDD/Seagate/ST3000/ST3000DM001-1CH166/265E66088B45
Normal file
169
HDD/Seagate/ST3000/ST3000DM001-1CH166/265E66088B45
Normal file
@@ -0,0 +1,169 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.14 (AF)
|
||||
Device Model: ST3000DM001-1CH166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC24
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Jun 13 10:04:18 2021 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 592) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 353) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 117 099 006 - 142003224
|
||||
3 Spin_Up_Time PO---- 095 093 000 - 0
|
||||
4 Start_Stop_Count -O--CK 091 091 020 - 9662
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 073 060 030 - 21480978
|
||||
9 Power_On_Hours -O--CK 090 090 000 - 9552
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 092 092 020 - 8662
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 0 1 1
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 068 045 045 Past 32 (Min/Max 29/32)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 431
|
||||
193 Load_Cycle_Count -O--CK 060 060 000 - 80532
|
||||
194 Temperature_Celsius -O---K 032 055 000 - 32 (0 16 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 4710h+18m+25.653s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 8138316481
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 19657439810
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbd GPL VS 512 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/30 Celsius
|
||||
Lifetime Min/Max Temperature: 16/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
167
HDD/Seagate/ST3000/ST3000DM001-1CH166/522F37F93C7B
Normal file
167
HDD/Seagate/ST3000/ST3000DM001-1CH166/522F37F93C7B
Normal file
@@ -0,0 +1,167 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p6 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.14 (AF)
|
||||
Device Model: ST3000DM001-1CH166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC29
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Jul 15 08:58:10 2021 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 192 (intermediate level without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 584) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 327) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 117 099 006 - 162801056
|
||||
3 Spin_Up_Time PO---- 094 093 000 - 0
|
||||
4 Start_Stop_Count -O--CK 094 094 020 - 7150
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 075 060 030 - 34661192
|
||||
9 Power_On_Hours -O--CK 083 083 000 - 15762
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 020 - 3106
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 0 0 1
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 069 050 045 - 31 (Min/Max 24/33)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 88
|
||||
193 Load_Cycle_Count -O--CK 076 076 000 - 48153
|
||||
194 Temperature_Celsius -O---K 031 050 000 - 31 (0 5 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 7843h+57m+09.353s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 39843971074
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 81933407378
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/33 Celsius
|
||||
Lifetime Min/Max Temperature: 5/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
168
HDD/Seagate/ST3000/ST3000DM001-1ER166/1CF90E333C94
Normal file
168
HDD/Seagate/ST3000/ST3000DM001-1ER166/1CF90E333C94
Normal file
@@ -0,0 +1,168 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.14 (AF)
|
||||
Device Model: ST3000DM001-1ER166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC25
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Sep 8 19:18:08 2021 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 89) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 332) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 111 099 006 - 32018216
|
||||
3 Spin_Up_Time PO---- 094 093 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 49
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 076 060 030 - 45049813
|
||||
9 Power_On_Hours -O--CK 073 073 000 - 23710
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 48
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 0 1 1
|
||||
189 High_Fly_Writes -O-RCK 099 099 000 - 1
|
||||
190 Airflow_Temperature_Cel -O---K 064 056 045 - 36 (Min/Max 33/40)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 3
|
||||
193 Load_Cycle_Count -O--CK 018 018 000 - 164401
|
||||
194 Temperature_Celsius -O---K 036 044 000 - 36 (0 18 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 15169h+58m+06.340s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 23727398599
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 330407094047
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/39 Celsius
|
||||
Lifetime Min/Max Temperature: 18/44 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
186
HDD/Seagate/ST3000/ST3000DM001-1ER166/4933AA75A6C0
Normal file
186
HDD/Seagate/ST3000/ST3000DM001-1ER166/4933AA75A6C0
Normal file
@@ -0,0 +1,186 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p6 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.14 (AF)
|
||||
Device Model: ST3000DM001-1ER166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC25
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Jul 15 08:58:10 2021 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 192 (intermediate level without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 80) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 318) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 119 099 006 - 229296664
|
||||
3 Spin_Up_Time PO---- 094 093 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 2025
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 078 060 030 - 64144502
|
||||
9 Power_On_Hours -O--CK 074 074 000 - 22885
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1993
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 098 000 - 0 0 2
|
||||
189 High_Fly_Writes -O-RCK 088 088 000 - 12
|
||||
190 Airflow_Temperature_Cel -O---K 069 051 045 - 31 (Min/Max 23/33)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 98
|
||||
193 Load_Cycle_Count -O--CK 062 062 000 - 76450
|
||||
194 Temperature_Celsius -O---K 031 049 000 - 31 (0 15 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 5
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 17996h+40m+26.265s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 51234843428
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 765530129220
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 22800 -
|
||||
# 2 Short offline Completed without error 00% 22641 -
|
||||
# 3 Short offline Completed without error 00% 22472 -
|
||||
# 4 Short offline Completed without error 00% 22313 -
|
||||
# 5 Short offline Completed without error 00% 22154 -
|
||||
# 6 Short offline Completed without error 00% 22002 -
|
||||
# 7 Short offline Completed without error 00% 21834 -
|
||||
# 8 Short offline Completed without error 00% 21675 -
|
||||
# 9 Short offline Completed without error 00% 21536 -
|
||||
#10 Short offline Completed without error 00% 21368 -
|
||||
#11 Short offline Completed without error 00% 21206 -
|
||||
#12 Short offline Completed without error 00% 21051 -
|
||||
#13 Short offline Completed without error 00% 20893 -
|
||||
#14 Short offline Completed without error 00% 20725 -
|
||||
#15 Short offline Completed without error 00% 20565 -
|
||||
#16 Short offline Completed without error 00% 20407 -
|
||||
#17 Short offline Completed without error 00% 20250 -
|
||||
#18 Short offline Completed without error 00% 20089 -
|
||||
#19 Short offline Completed without error 00% 19922 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/32 Celsius
|
||||
Lifetime Min/Max Temperature: 15/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
165
HDD/Seagate/ST3000/ST3000DM001-1ER166/7962E44FE28A
Normal file
165
HDD/Seagate/ST3000/ST3000DM001-1ER166/7962E44FE28A
Normal file
@@ -0,0 +1,165 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p4 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.14 (AF)
|
||||
Device Model: ST3000DM001-1ER166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC25
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Sep 29 09:25:26 2021 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 80) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 324) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 119 094 006 - 206639128
|
||||
3 Spin_Up_Time PO---- 094 094 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 116
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 072 060 030 - 19766108
|
||||
9 Power_On_Hours -O--CK 054 054 000 - 40925
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 116
|
||||
183 Runtime_Bad_Block -O--CK 099 099 000 - 1
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 0 0 1
|
||||
189 High_Fly_Writes -O-RCK 082 082 000 - 18
|
||||
190 Airflow_Temperature_Cel -O---K 061 055 045 - 39 (Min/Max 38/39)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 2
|
||||
193 Load_Cycle_Count -O--CK 017 017 000 - 167110
|
||||
194 Temperature_Celsius -O---K 039 045 000 - 39 (0 16 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 080 080 000 - 3392
|
||||
198 Offline_Uncorrectable ----C- 080 080 000 - 3392
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 4789h+21m+21.324s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 55032323943
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 44524667803
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 35/39 Celsius
|
||||
Lifetime Min/Max Temperature: 16/44 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
166
HDD/Seagate/ST3000/ST3000DM001-1ER166/FF447D66A1F2
Normal file
166
HDD/Seagate/ST3000/ST3000DM001-1ER166/FF447D66A1F2
Normal file
@@ -0,0 +1,166 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.14 (AF)
|
||||
Device Model: ST3000DM001-1ER166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC25
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Sep 8 19:18:08 2021 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 80) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 321) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 118 099 006 - 180822536
|
||||
3 Spin_Up_Time PO---- 094 094 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 47
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 076 060 030 - 44851850
|
||||
9 Power_On_Hours -O--CK 073 073 000 - 23708
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 46
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 0 1 1
|
||||
189 High_Fly_Writes -O-RCK 094 094 000 - 6
|
||||
190 Airflow_Temperature_Cel -O---K 065 057 045 - 35 (Min/Max 32/39)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 3
|
||||
193 Load_Cycle_Count -O--CK 018 018 000 - 164422
|
||||
194 Temperature_Celsius -O---K 035 043 000 - 35 (0 18 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 15166h+02m+56.749s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 23727447663
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 403459849056
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/39 Celsius
|
||||
Lifetime Min/Max Temperature: 18/42 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
192
HDD/Seagate/ST3000/ST3000DM003-1F216N/2F98EFBB1B3C
Normal file
192
HDD/Seagate/ST3000/ST3000DM003-1F216N/2F98EFBB1B3C
Normal file
@@ -0,0 +1,192 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.14 (AF)
|
||||
Device Model: ST3000DM003-1F216N
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC54
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sun Jul 18 22:15:40 2021 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 117) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 426) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 114 099 006 - 80688152
|
||||
3 Spin_Up_Time PO---- 094 092 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 371
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 072 060 030 - 4313174605
|
||||
9 Power_On_Hours -O--CK 084 084 000 - 14810
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 141
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 5 5 7
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 063 048 045 - 37 (Min/Max 35/37)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 23
|
||||
193 Load_Cycle_Count -O--CK 092 092 000 - 16796
|
||||
194 Temperature_Celsius -O---K 037 052 000 - 37 (0 17 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 7807h+02m+48.483s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 21966232832
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 261301592135
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 1223 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 1223 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/37 Celsius
|
||||
Lifetime Min/Max Temperature: 17/52 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 141 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 14810 --- Power-on Hours
|
||||
0x01 0x018 6 21872205832 --- Logical Sectors Written
|
||||
0x01 0x020 6 387254689 --- Number of Write Commands
|
||||
0x01 0x028 6 8019281737 --- Logical Sectors Read
|
||||
0x01 0x030 6 76641034 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 14598 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 5940 --- Head Flying Hours
|
||||
0x03 0x018 4 16796 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 7 --- Resets Between Cmd Acceptance and Completion
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
169
HDD/Seagate/ST3000/ST3000DM008-2DM166/62A3A1B10009
Normal file
169
HDD/Seagate/ST3000/ST3000DM008-2DM166/62A3A1B10009
Normal file
@@ -0,0 +1,169 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate BarraCuda 3.5
|
||||
Device Model: ST3000DM008-2DM166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC26
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Dec 19 11:32:38 2021 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 89) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 320) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 112 099 006 - 42757640
|
||||
3 Spin_Up_Time PO---- 095 094 000 - 0
|
||||
4 Start_Stop_Count -O--CK 097 097 020 - 3934
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 058 057 030 - 902091153232
|
||||
9 Power_On_Hours -O--CK 075 075 000 - 21927
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 2007
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 8 8 8
|
||||
189 High_Fly_Writes -O-RCK 096 096 000 - 4
|
||||
190 Airflow_Temperature_Cel -O---K 062 052 045 - 38 (Min/Max 28/38)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 59
|
||||
193 Load_Cycle_Count -O--CK 052 052 000 - 96074
|
||||
194 Temperature_Celsius -O---K 038 048 000 - 38 (0 14 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 14202h+38m+58.726s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 107401360701
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 446247256501
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 17880 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/38 Celsius
|
||||
Lifetime Min/Max Temperature: 14/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 70 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
187
HDD/Seagate/ST3000/ST3000DM008-2DM166/9CB9E962B7CE
Normal file
187
HDD/Seagate/ST3000/ST3000DM008-2DM166/9CB9E962B7CE
Normal file
@@ -0,0 +1,187 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate BarraCuda 3.5
|
||||
Device Model: ST3000DM008-2DM166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC26
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Jun 21 19:34:06 2021 MST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 80) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 314) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 114 099 006 - 63688344
|
||||
3 Spin_Up_Time PO---- 094 093 000 - 0
|
||||
4 Start_Stop_Count -O--CK 096 096 020 - 4300
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 072 060 030 - 17961186
|
||||
9 Power_On_Hours -O--CK 092 092 000 - 7875
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 020 - 2873
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 0 0 1
|
||||
189 High_Fly_Writes -O-RCK 099 099 000 - 1
|
||||
190 Airflow_Temperature_Cel -O---K 063 052 045 - 37 (Min/Max 32/37)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 147
|
||||
193 Load_Cycle_Count -O--CK 083 083 000 - 35921
|
||||
194 Temperature_Celsius -O---K 037 048 000 - 37 (0 17 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 4451h+14m+32.262s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 14196677730
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 64901150917
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 7317 -
|
||||
# 2 Short offline Completed without error 00% 7307 -
|
||||
# 3 Short offline Completed without error 00% 4195 -
|
||||
# 4 Short offline Completed without error 00% 4160 -
|
||||
# 5 Short offline Completed without error 00% 4158 -
|
||||
# 6 Extended offline Aborted by host 90% 4108 -
|
||||
# 7 Short offline Completed without error 00% 4082 -
|
||||
# 8 Short offline Completed without error 00% 3989 -
|
||||
# 9 Short offline Completed without error 00% 3983 -
|
||||
#10 Short offline Completed without error 00% 3955 -
|
||||
#11 Extended offline Interrupted (host reset) 90% 3920 -
|
||||
#12 Short offline Completed without error 00% 3886 -
|
||||
#13 Short offline Completed without error 00% 3852 -
|
||||
#14 Short offline Completed without error 00% 3841 -
|
||||
#15 Short offline Completed without error 00% 3839 -
|
||||
#16 Short offline Completed without error 00% 3817 -
|
||||
#17 Short offline Completed without error 00% 3804 -
|
||||
#18 Short offline Completed without error 00% 3794 -
|
||||
#19 Short offline Completed without error 00% 3793 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/37 Celsius
|
||||
Lifetime Min/Max Temperature: 16/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
187
HDD/Seagate/ST3000/ST3000DM008-2DM166/CD26C535A875
Normal file
187
HDD/Seagate/ST3000/ST3000DM008-2DM166/CD26C535A875
Normal file
@@ -0,0 +1,187 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p6 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate BarraCuda 3.5
|
||||
Device Model: ST3000DM008-2DM166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC26
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Jul 15 08:58:17 2021 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 192 (intermediate level without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 89) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 327) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 116 099 006 - 114477624
|
||||
3 Spin_Up_Time PO---- 094 093 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 825
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 078 060 030 - 83788786
|
||||
9 Power_On_Hours -O--CK 072 072 000 - 25357
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 726
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 096 000 - 1 1 7
|
||||
189 High_Fly_Writes -O-RCK 094 094 000 - 6
|
||||
190 Airflow_Temperature_Cel -O---K 069 057 045 - 31 (Min/Max 24/33)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 484
|
||||
193 Load_Cycle_Count -O--CK 049 049 000 - 103666
|
||||
194 Temperature_Celsius -O---K 031 043 000 - 31 (0 19 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 17567h+29m+59.977s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 21672822912
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1711980574258
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 25271 -
|
||||
# 2 Short offline Completed without error 00% 25112 -
|
||||
# 3 Short offline Completed without error 00% 24944 -
|
||||
# 4 Short offline Completed without error 00% 24784 -
|
||||
# 5 Short offline Completed without error 00% 24625 -
|
||||
# 6 Short offline Completed without error 00% 24473 -
|
||||
# 7 Short offline Completed without error 00% 24305 -
|
||||
# 8 Short offline Completed without error 00% 24147 -
|
||||
# 9 Short offline Completed without error 00% 24007 -
|
||||
#10 Short offline Completed without error 00% 23839 -
|
||||
#11 Short offline Completed without error 00% 23678 -
|
||||
#12 Short offline Completed without error 00% 23522 -
|
||||
#13 Short offline Completed without error 00% 23365 -
|
||||
#14 Short offline Completed without error 00% 23197 -
|
||||
#15 Short offline Completed without error 00% 23037 -
|
||||
#16 Short offline Completed without error 00% 22879 -
|
||||
#17 Short offline Completed without error 00% 22722 -
|
||||
#18 Short offline Completed without error 00% 22560 -
|
||||
#19 Short offline Completed without error 00% 22393 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/32 Celsius
|
||||
Lifetime Min/Max Temperature: 19/43 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
232
HDD/Seagate/ST3000/ST3000NM0033-9ZM178/59B425460BFE
Normal file
232
HDD/Seagate/ST3000/ST3000NM0033-9ZM178/59B425460BFE
Normal file
@@ -0,0 +1,232 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Constellation ES.3
|
||||
Device Model: ST3000NM0033-9ZM178
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Add. Product Id: DELL(tm)
|
||||
Firmware Version: GA10
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat Oct 2 04:05:18 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 90) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 383) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR--+ 077 063 --- - 58270919
|
||||
3 Spin_Up_Time PO----+ 094 093 --- - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 --- - 142
|
||||
5 Reallocated_Sector_Ct PO--CK+ 100 100 --- - 0
|
||||
7 Seek_Error_Rate POSR-- 092 060 --- - 1634615146
|
||||
9 Power_On_Hours -O--CK 062 062 --- - 33575
|
||||
10 Spin_Retry_Count PO--C- 100 100 --- - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 --- - 127
|
||||
184 End-to-End_Error -O--CK 100 100 --- - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 --- - 0
|
||||
188 Command_Timeout -O--CK 100 099 --- - 4295032833
|
||||
189 High_Fly_Writes -O-RCK 100 100 --- - 0
|
||||
190 Airflow_Temperature_Cel -O---K 063 048 --- - 37 (Min/Max 33/40)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 --- - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 --- - 127
|
||||
193 Load_Cycle_Count -O--CK 099 099 --- - 2811
|
||||
194 Temperature_Celsius -O---K 037 052 --- - 37 (0 11 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 017 012 --- - 58270919
|
||||
196 Reallocated_Event_Count -O--CK 000 000 --- - 21845
|
||||
197 Current_Pending_Sector -O--C- 100 100 --- - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 --- - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 --- - 0
|
||||
240 Head_Flying_Hours ------ 100 253 --- - 30353 (96 28 0)
|
||||
241 Total_LBAs_Written ------ 100 253 --- - 358353260619
|
||||
242 Total_LBAs_Read ------ 100 253 --- - 11041561565639
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x98 GPL,SL R/W 16 Host vendor specific log
|
||||
0x99-0x9a GPL,SL R/W 1 Host vendor specific log
|
||||
0x9b-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbd GPL VS 512 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xd1 GPL VS 39 Device vendor specific log
|
||||
0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 33509 -
|
||||
# 2 Extended offline Completed without error 00% 27296 -
|
||||
# 3 Short offline Completed without error 00% 27289 -
|
||||
# 4 Short offline Completed without error 00% 27224 -
|
||||
# 5 Short offline Completed without error 00% 1 -
|
||||
# 6 Vendor (0xdf) Completed without error 00% 1 -
|
||||
# 7 Short offline Completed without error 00% 2 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/40 Celsius
|
||||
Lifetime Min/Max Temperature: 11/52 Celsius
|
||||
Under/Over Temperature Limit Count: 0/91
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (36)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 80 (8.0 seconds)
|
||||
Write: 80 (8.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 127 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 33575 --- Power-on Hours
|
||||
0x01 0x018 6 863187795 --- Logical Sectors Written
|
||||
0x01 0x020 6 7532279 --- Number of Write Commands
|
||||
0x01 0x028 6 835738214 --- Logical Sectors Read
|
||||
0x01 0x030 6 6608280 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 108 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 43 --- Head Flying Hours
|
||||
0x03 0x018 4 2811 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 128 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 38 --- Current Temperature
|
||||
0x05 0x020 1 52 --- Highest Temperature
|
||||
0x05 0x028 1 30 --- Lowest Temperature
|
||||
0x05 0x030 1 - --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 - --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
232
HDD/Seagate/ST3000/ST3000NM0033-9ZM178/70A0521268E6
Normal file
232
HDD/Seagate/ST3000/ST3000NM0033-9ZM178/70A0521268E6
Normal file
@@ -0,0 +1,232 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Constellation ES.3
|
||||
Device Model: ST3000NM0033-9ZM178
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Add. Product Id: DELL(tm)
|
||||
Firmware Version: GA10
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat Oct 2 04:05:19 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 90) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 379) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR--+ 077 063 --- - 54826407
|
||||
3 Spin_Up_Time PO----+ 093 093 --- - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 --- - 142
|
||||
5 Reallocated_Sector_Ct PO--CK+ 100 100 --- - 0
|
||||
7 Seek_Error_Rate POSR-- 092 060 --- - 1612207917
|
||||
9 Power_On_Hours -O--CK 062 062 --- - 33570
|
||||
10 Spin_Retry_Count PO--C- 100 100 --- - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 --- - 127
|
||||
184 End-to-End_Error -O--CK 100 100 --- - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 --- - 0
|
||||
188 Command_Timeout -O--CK 100 100 --- - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 --- - 0
|
||||
190 Airflow_Temperature_Cel -O---K 063 050 --- - 37 (Min/Max 32/40)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 --- - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 --- - 127
|
||||
193 Load_Cycle_Count -O--CK 099 099 --- - 2613
|
||||
194 Temperature_Celsius -O---K 037 050 --- - 37 (0 12 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 023 014 --- - 54826407
|
||||
196 Reallocated_Event_Count -O--CK 000 000 --- - 65535
|
||||
197 Current_Pending_Sector -O--C- 100 100 --- - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 --- - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 --- - 0
|
||||
240 Head_Flying_Hours ------ 100 253 --- - 30192 (155 209 0)
|
||||
241 Total_LBAs_Written ------ 100 253 --- - 355289646600
|
||||
242 Total_LBAs_Read ------ 100 253 --- - 11434481979559
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x98 GPL,SL R/W 16 Host vendor specific log
|
||||
0x99-0x9a GPL,SL R/W 1 Host vendor specific log
|
||||
0x9b-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbd GPL VS 512 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xd1 GPL VS 39 Device vendor specific log
|
||||
0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 33504 -
|
||||
# 2 Extended offline Completed without error 00% 27293 -
|
||||
# 3 Short offline Completed without error 00% 27286 -
|
||||
# 4 Short offline Completed without error 00% 27221 -
|
||||
# 5 Short offline Completed without error 00% 1 -
|
||||
# 6 Vendor (0xdf) Completed without error 00% 1 -
|
||||
# 7 Short offline Completed without error 00% 2 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/40 Celsius
|
||||
Lifetime Min/Max Temperature: 12/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/90
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (17)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 80 (8.0 seconds)
|
||||
Write: 80 (8.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 127 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 33570 --- Power-on Hours
|
||||
0x01 0x018 6 64143227 --- Logical Sectors Written
|
||||
0x01 0x020 6 1290363 --- Number of Write Commands
|
||||
0x01 0x028 6 836648827 --- Logical Sectors Read
|
||||
0x01 0x030 6 6616179 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 108 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 43 --- Head Flying Hours
|
||||
0x03 0x018 4 2613 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 128 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 37 --- Current Temperature
|
||||
0x05 0x020 1 49 --- Highest Temperature
|
||||
0x05 0x028 1 30 --- Lowest Temperature
|
||||
0x05 0x030 1 - --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 - --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
232
HDD/Seagate/ST3000/ST3000NM0033-9ZM178/7CC00D857104
Normal file
232
HDD/Seagate/ST3000/ST3000NM0033-9ZM178/7CC00D857104
Normal file
@@ -0,0 +1,232 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Constellation ES.3
|
||||
Device Model: ST3000NM0033-9ZM178
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Add. Product Id: DELL(tm)
|
||||
Firmware Version: GA10
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat Oct 2 04:05:21 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 90) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 386) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR--+ 081 063 --- - 165054114
|
||||
3 Spin_Up_Time PO----+ 094 093 --- - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 --- - 142
|
||||
5 Reallocated_Sector_Ct PO--CK+ 100 100 --- - 0
|
||||
7 Seek_Error_Rate POSR-- 092 060 --- - 1634203722
|
||||
9 Power_On_Hours -O--CK 062 062 --- - 33573
|
||||
10 Spin_Retry_Count PO--C- 100 100 --- - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 --- - 128
|
||||
184 End-to-End_Error -O--CK 100 100 --- - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 --- - 0
|
||||
188 Command_Timeout -O--CK 100 099 --- - 2
|
||||
189 High_Fly_Writes -O-RCK 100 100 --- - 0
|
||||
190 Airflow_Temperature_Cel -O---K 062 047 --- - 38 (Min/Max 32/41)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 --- - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 --- - 128
|
||||
193 Load_Cycle_Count -O--CK 099 099 --- - 3816
|
||||
194 Temperature_Celsius -O---K 038 053 --- - 38 (0 10 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 021 015 --- - 165054114
|
||||
196 Reallocated_Event_Count -O--CK 000 000 --- - 65503
|
||||
197 Current_Pending_Sector -O--C- 100 100 --- - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 --- - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 --- - 0
|
||||
240 Head_Flying_Hours ------ 100 253 --- - 30327 (104 39 0)
|
||||
241 Total_LBAs_Written ------ 100 253 --- - 355153589921
|
||||
242 Total_LBAs_Read ------ 100 253 --- - 11667165534617
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x98 GPL,SL R/W 16 Host vendor specific log
|
||||
0x99-0x9a GPL,SL R/W 1 Host vendor specific log
|
||||
0x9b-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbd GPL VS 512 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xd1 GPL VS 39 Device vendor specific log
|
||||
0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 33507 -
|
||||
# 2 Extended offline Completed without error 00% 27294 -
|
||||
# 3 Short offline Completed without error 00% 27288 -
|
||||
# 4 Short offline Completed without error 00% 27222 -
|
||||
# 5 Short offline Completed without error 00% 1 -
|
||||
# 6 Vendor (0xdf) Completed without error 00% 1 -
|
||||
# 7 Short offline Completed without error 00% 2 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/41 Celsius
|
||||
Lifetime Min/Max Temperature: 10/53 Celsius
|
||||
Under/Over Temperature Limit Count: 0/90
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (55)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 80 (8.0 seconds)
|
||||
Write: 80 (8.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 128 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 33573 --- Power-on Hours
|
||||
0x01 0x018 6 64108072 --- Logical Sectors Written
|
||||
0x01 0x020 6 1289895 --- Number of Write Commands
|
||||
0x01 0x028 6 3358387 --- Logical Sectors Read
|
||||
0x01 0x030 6 106168 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 108 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 43 --- Head Flying Hours
|
||||
0x03 0x018 4 3816 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 129 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 38 --- Current Temperature
|
||||
0x05 0x020 1 53 --- Highest Temperature
|
||||
0x05 0x028 1 29 --- Lowest Temperature
|
||||
0x05 0x030 1 - --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 - --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
230
HDD/Seagate/ST3000/ST3000NM0033-9ZM178/8FC482BD9F96
Normal file
230
HDD/Seagate/ST3000/ST3000NM0033-9ZM178/8FC482BD9F96
Normal file
@@ -0,0 +1,230 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Constellation ES.3
|
||||
Device Model: ST3000NM0033-9ZM178
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Add. Product Id: DELL(tm)
|
||||
Firmware Version: GA10
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat Oct 2 04:05:22 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 90) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 401) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR--+ 081 063 --- - 128101500
|
||||
3 Spin_Up_Time PO----+ 094 093 --- - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 --- - 136
|
||||
5 Reallocated_Sector_Ct PO--CK+ 100 100 --- - 0
|
||||
7 Seek_Error_Rate POSR-- 092 060 --- - 1671227734
|
||||
9 Power_On_Hours -O--CK 062 062 --- - 33800
|
||||
10 Spin_Retry_Count PO--C- 100 100 --- - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 --- - 126
|
||||
184 End-to-End_Error -O--CK 100 100 --- - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 --- - 0
|
||||
188 Command_Timeout -O--CK 100 100 --- - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 --- - 0
|
||||
190 Airflow_Temperature_Cel -O---K 063 050 --- - 37 (Min/Max 32/41)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 --- - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 --- - 125
|
||||
193 Load_Cycle_Count -O--CK 099 099 --- - 3073
|
||||
194 Temperature_Celsius -O---K 037 050 --- - 37 (0 12 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 030 006 --- - 128101500
|
||||
196 Reallocated_Event_Count -O--CK 000 000 --- - 63476
|
||||
197 Current_Pending_Sector -O--C- 100 100 --- - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 --- - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 --- - 0
|
||||
240 Head_Flying_Hours ------ 100 253 --- - 30181 (225 189 0)
|
||||
241 Total_LBAs_Written ------ 100 253 --- - 355962461064
|
||||
242 Total_LBAs_Read ------ 100 253 --- - 13046019294079
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x98 GPL,SL R/W 16 Host vendor specific log
|
||||
0x99-0x9a GPL,SL R/W 1 Host vendor specific log
|
||||
0x9b-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbd GPL VS 512 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xd1 GPL VS 39 Device vendor specific log
|
||||
0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 33734 -
|
||||
# 2 Extended offline Completed without error 00% 27522 -
|
||||
# 3 Short offline Completed without error 00% 27515 -
|
||||
# 4 Short offline Completed without error 00% 27513 -
|
||||
# 5 Short offline Completed without error 00% 1 -
|
||||
# 6 Vendor (0xdf) Completed without error 00% 1 -
|
||||
# 7 Short offline Completed without error 00% 1 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/40 Celsius
|
||||
Lifetime Min/Max Temperature: 12/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/90
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (37)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 80 (8.0 seconds)
|
||||
Write: 80 (8.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 126 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 33800 --- Power-on Hours
|
||||
0x01 0x018 6 64127675 --- Logical Sectors Written
|
||||
0x01 0x020 6 1289217 --- Number of Write Commands
|
||||
0x01 0x028 6 837073538 --- Logical Sectors Read
|
||||
0x01 0x030 6 6618770 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 107 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 43 --- Head Flying Hours
|
||||
0x03 0x018 4 3073 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 126 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 37 --- Current Temperature
|
||||
0x05 0x020 1 49 --- Highest Temperature
|
||||
0x05 0x028 1 30 --- Lowest Temperature
|
||||
0x05 0x030 1 - --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 - --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
232
HDD/Seagate/ST3000/ST3000NM0033-9ZM178/90EFF026D580
Normal file
232
HDD/Seagate/ST3000/ST3000NM0033-9ZM178/90EFF026D580
Normal file
@@ -0,0 +1,232 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Constellation ES.3
|
||||
Device Model: ST3000NM0033-9ZM178
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Add. Product Id: DELL(tm)
|
||||
Firmware Version: GA10
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat Oct 2 04:05:19 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 90) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 379) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR--+ 082 063 --- - 194762769
|
||||
3 Spin_Up_Time PO----+ 093 093 --- - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 --- - 143
|
||||
5 Reallocated_Sector_Ct PO--CK+ 100 100 --- - 0
|
||||
7 Seek_Error_Rate POSR-- 092 060 --- - 1617168792
|
||||
9 Power_On_Hours -O--CK 062 062 --- - 33570
|
||||
10 Spin_Retry_Count PO--C- 100 100 --- - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 --- - 128
|
||||
184 End-to-End_Error -O--CK 100 100 --- - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 --- - 0
|
||||
188 Command_Timeout -O--CK 100 099 --- - 1
|
||||
189 High_Fly_Writes -O-RCK 100 100 --- - 0
|
||||
190 Airflow_Temperature_Cel -O---K 061 047 --- - 39 (Min/Max 33/44)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 --- - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 --- - 128
|
||||
193 Load_Cycle_Count -O--CK 099 099 --- - 2610
|
||||
194 Temperature_Celsius -O---K 039 053 --- - 39 (0 10 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 022 009 --- - 194762769
|
||||
196 Reallocated_Event_Count -O--CK 000 000 --- - 30589
|
||||
197 Current_Pending_Sector -O--C- 100 100 --- - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 --- - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 --- - 0
|
||||
240 Head_Flying_Hours ------ 100 253 --- - 30193 (167 247 0)
|
||||
241 Total_LBAs_Written ------ 100 253 --- - 359483567531
|
||||
242 Total_LBAs_Read ------ 100 253 --- - 11378554396995
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x98 GPL,SL R/W 16 Host vendor specific log
|
||||
0x99-0x9a GPL,SL R/W 1 Host vendor specific log
|
||||
0x9b-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbd GPL VS 512 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xd1 GPL VS 39 Device vendor specific log
|
||||
0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 33504 -
|
||||
# 2 Extended offline Completed without error 00% 27292 -
|
||||
# 3 Short offline Completed without error 00% 27286 -
|
||||
# 4 Short offline Completed without error 00% 27221 -
|
||||
# 5 Short offline Completed without error 00% 1 -
|
||||
# 6 Vendor (0xdf) Completed without error 00% 1 -
|
||||
# 7 Short offline Completed without error 00% 2 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/43 Celsius
|
||||
Lifetime Min/Max Temperature: 10/53 Celsius
|
||||
Under/Over Temperature Limit Count: 0/90
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (91)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 80 (8.0 seconds)
|
||||
Write: 80 (8.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 128 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 33570 --- Power-on Hours
|
||||
0x01 0x018 6 864171487 --- Logical Sectors Written
|
||||
0x01 0x020 6 7541395 --- Number of Write Commands
|
||||
0x01 0x028 6 837148643 --- Logical Sectors Read
|
||||
0x01 0x030 6 6619753 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 108 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 43 --- Head Flying Hours
|
||||
0x03 0x018 4 2610 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 129 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 1 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 39 --- Current Temperature
|
||||
0x05 0x020 1 53 --- Highest Temperature
|
||||
0x05 0x028 1 30 --- Lowest Temperature
|
||||
0x05 0x030 1 - --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 - --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
232
HDD/Seagate/ST3000/ST3000NM0033-9ZM178/9E3B3B6A785A
Normal file
232
HDD/Seagate/ST3000/ST3000NM0033-9ZM178/9E3B3B6A785A
Normal file
@@ -0,0 +1,232 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Constellation ES.3
|
||||
Device Model: ST3000NM0033-9ZM178
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Add. Product Id: DELL(tm)
|
||||
Firmware Version: GA10
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat Oct 2 04:05:22 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 90) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 384) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR--+ 081 063 --- - 125849956
|
||||
3 Spin_Up_Time PO----+ 094 093 --- - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 --- - 142
|
||||
5 Reallocated_Sector_Ct PO--CK+ 100 100 --- - 0
|
||||
7 Seek_Error_Rate POSR-- 092 060 --- - 1633793594
|
||||
9 Power_On_Hours -O--CK 062 062 --- - 33529
|
||||
10 Spin_Retry_Count PO--C- 100 100 --- - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 --- - 127
|
||||
184 End-to-End_Error -O--CK 100 100 --- - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 --- - 0
|
||||
188 Command_Timeout -O--CK 100 100 --- - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 --- - 0
|
||||
190 Airflow_Temperature_Cel -O---K 062 047 --- - 38 (Min/Max 33/42)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 --- - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 --- - 127
|
||||
193 Load_Cycle_Count -O--CK 099 099 --- - 2603
|
||||
194 Temperature_Celsius -O---K 038 053 --- - 38 (0 11 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 021 013 --- - 125849956
|
||||
196 Reallocated_Event_Count -O--CK 000 000 --- - 63487
|
||||
197 Current_Pending_Sector -O--C- 100 100 --- - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 --- - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 --- - 0
|
||||
240 Head_Flying_Hours ------ 100 253 --- - 30200 (155 153 0)
|
||||
241 Total_LBAs_Written ------ 100 253 --- - 355469086049
|
||||
242 Total_LBAs_Read ------ 100 253 --- - 9683659862214
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x98 GPL,SL R/W 16 Host vendor specific log
|
||||
0x99-0x9a GPL,SL R/W 1 Host vendor specific log
|
||||
0x9b-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbd GPL VS 512 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xd1 GPL VS 39 Device vendor specific log
|
||||
0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 33463 -
|
||||
# 2 Extended offline Completed without error 00% 27293 -
|
||||
# 3 Short offline Completed without error 00% 27286 -
|
||||
# 4 Short offline Completed without error 00% 27221 -
|
||||
# 5 Short offline Completed without error 00% 1 -
|
||||
# 6 Vendor (0xdf) Completed without error 00% 1 -
|
||||
# 7 Short offline Completed without error 00% 2 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/42 Celsius
|
||||
Lifetime Min/Max Temperature: 11/53 Celsius
|
||||
Under/Over Temperature Limit Count: 0/90
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (78)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 80 (8.0 seconds)
|
||||
Write: 80 (8.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 127 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 33529 --- Power-on Hours
|
||||
0x01 0x018 6 64148907 --- Logical Sectors Written
|
||||
0x01 0x020 6 1291530 --- Number of Write Commands
|
||||
0x01 0x028 6 834148336 --- Logical Sectors Read
|
||||
0x01 0x030 6 6595674 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 108 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 43 --- Head Flying Hours
|
||||
0x03 0x018 4 2603 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 128 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 38 --- Current Temperature
|
||||
0x05 0x020 1 52 --- Highest Temperature
|
||||
0x05 0x028 1 29 --- Lowest Temperature
|
||||
0x05 0x030 1 - --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 - --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
232
HDD/Seagate/ST3000/ST3000NM0033-9ZM178/DDBA88E26B33
Normal file
232
HDD/Seagate/ST3000/ST3000NM0033-9ZM178/DDBA88E26B33
Normal file
@@ -0,0 +1,232 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Constellation ES.3
|
||||
Device Model: ST3000NM0033-9ZM178
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Add. Product Id: DELL(tm)
|
||||
Firmware Version: GA10
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat Oct 2 04:05:21 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 90) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 402) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR--+ 083 063 --- - 201469955
|
||||
3 Spin_Up_Time PO----+ 094 093 --- - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 --- - 136
|
||||
5 Reallocated_Sector_Ct PO--CK+ 100 100 --- - 0
|
||||
7 Seek_Error_Rate POSR-- 092 060 --- - 1689657259
|
||||
9 Power_On_Hours -O--CK 062 062 --- - 33798
|
||||
10 Spin_Retry_Count PO--C- 100 100 --- - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 --- - 125
|
||||
184 End-to-End_Error -O--CK 100 100 --- - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 --- - 0
|
||||
188 Command_Timeout -O--CK 100 100 --- - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 --- - 0
|
||||
190 Airflow_Temperature_Cel -O---K 063 051 --- - 37 (Min/Max 32/41)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 --- - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 --- - 125
|
||||
193 Load_Cycle_Count -O--CK 099 099 --- - 2336
|
||||
194 Temperature_Celsius -O---K 037 049 --- - 37 (0 12 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 023 009 --- - 201469955
|
||||
196 Reallocated_Event_Count -O--CK 000 000 --- - 24031
|
||||
197 Current_Pending_Sector -O--C- 100 100 --- - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 --- - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 --- - 0
|
||||
240 Head_Flying_Hours ------ 100 253 --- - 30029 (215 192 0)
|
||||
241 Total_LBAs_Written ------ 100 253 --- - 356013263232
|
||||
242 Total_LBAs_Read ------ 100 253 --- - 12717268981245
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x98 GPL,SL R/W 16 Host vendor specific log
|
||||
0x99-0x9a GPL,SL R/W 1 Host vendor specific log
|
||||
0x9b-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbd GPL VS 512 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xd1 GPL VS 39 Device vendor specific log
|
||||
0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 33733 -
|
||||
# 2 Extended offline Completed without error 00% 27522 -
|
||||
# 3 Short offline Completed without error 00% 27515 -
|
||||
# 4 Short offline Completed without error 00% 27513 -
|
||||
# 5 Short offline Completed without error 00% 1 -
|
||||
# 6 Vendor (0xdf) Completed without error 00% 1 -
|
||||
# 7 Short offline Completed without error 00% 1 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/40 Celsius
|
||||
Lifetime Min/Max Temperature: 12/49 Celsius
|
||||
Under/Over Temperature Limit Count: 0/90
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (31)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 80 (8.0 seconds)
|
||||
Write: 80 (8.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 125 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 33798 --- Power-on Hours
|
||||
0x01 0x018 6 852721392 --- Logical Sectors Written
|
||||
0x01 0x020 6 7451405 --- Number of Write Commands
|
||||
0x01 0x028 6 822359293 --- Logical Sectors Read
|
||||
0x01 0x030 6 6503365 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 107 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 43 --- Head Flying Hours
|
||||
0x03 0x018 4 2336 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 126 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 37 --- Current Temperature
|
||||
0x05 0x020 1 49 --- Highest Temperature
|
||||
0x05 0x028 1 29 --- Lowest Temperature
|
||||
0x05 0x030 1 - --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 - --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
222
HDD/Seagate/ST3000/ST3000VN007-2AH16M/697D709BBD49
Normal file
222
HDD/Seagate/ST3000/ST3000VN007-2AH16M/697D709BBD49
Normal file
@@ -0,0 +1,222 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p10 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate IronWolf
|
||||
Device Model: ST3000VN007-2AH16M
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5980 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Jun 1 23:29:03 2021 +05
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 591) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 499) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 082 064 044 - 160705544
|
||||
3 Spin_Up_Time PO---- 094 094 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 83
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 095 060 045 - 3031035623
|
||||
9 Power_On_Hours -O--CK 081 081 000 - 17502 (5 79 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 83
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 067 060 040 - 33 (Min/Max 28/37)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 081 081 000 - 39962
|
||||
194 Temperature_Celsius -O---K 033 040 000 - 33 (0 19 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 14834 (95 104 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 7457267639
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 116994623461
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 9048 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 136 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/37 Celsius
|
||||
Lifetime Min/Max Temperature: 19/40 Celsius
|
||||
Under/Over Temperature Limit Count: 0/293
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (110)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 83 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 17502 --- Power-on Hours
|
||||
0x01 0x018 6 7459974599 --- Logical Sectors Written
|
||||
0x01 0x020 6 36514896 --- Number of Write Commands
|
||||
0x01 0x028 6 117013145404 --- Logical Sectors Read
|
||||
0x01 0x030 6 647022866 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 17504 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 490 --- Head Flying Hours
|
||||
0x03 0x018 4 39962 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 1 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x010 1 33 --- Average Short Term Temperature
|
||||
0x05 0x018 1 32 --- Average Long Term Temperature
|
||||
0x05 0x020 1 40 --- Highest Temperature
|
||||
0x05 0x028 1 0 --- Lowest Temperature
|
||||
0x05 0x030 1 38 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 25 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 34 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 29 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 146 --- Number of Hardware Resets
|
||||
0x06 0x010 4 6 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
176
HDD/Seagate/ST3000/ST3000VN007-2E4166/66A0222E125A
Normal file
176
HDD/Seagate/ST3000/ST3000VN007-2E4166/66A0222E125A
Normal file
@@ -0,0 +1,176 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p10 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate IronWolf
|
||||
Device Model: ST3000VN007-2E4166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jun 1 23:29:03 2021 +05
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 192 (intermediate level without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 107) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 385) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x10bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 117 099 006 - 161873576
|
||||
3 Spin_Up_Time PO---- 094 093 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 190
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 084 060 030 - 333519594
|
||||
9 Power_On_Hours -O--CK 065 065 000 - 31010
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 189
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 1
|
||||
189 High_Fly_Writes -O-RCK 001 001 000 - 267
|
||||
190 Airflow_Temperature_Cel -O---K 067 053 045 - 33 (Min/Max 29/38)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 103
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 256
|
||||
194 Temperature_Celsius -O---K 033 047 000 - 33 (0 17 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xd1 GPL,SL VS 8 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/38 Celsius
|
||||
Lifetime Min/Max Temperature: 17/45 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 94 minutes
|
||||
Min/Max recommended Temperature: 1/61 Celsius
|
||||
Min/Max Temperature Limit: 2/60 Celsius
|
||||
Temperature History Size (Index): 128 (63)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
176
HDD/Seagate/ST3000/ST3000VN007-2E4166/78B3C2DFEBB0
Normal file
176
HDD/Seagate/ST3000/ST3000VN007-2E4166/78B3C2DFEBB0
Normal file
@@ -0,0 +1,176 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p10 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate IronWolf
|
||||
Device Model: ST3000VN007-2E4166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jun 1 23:29:03 2021 +05
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 192 (intermediate level without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 107) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 405) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x10bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 112 099 006 - 43499648
|
||||
3 Spin_Up_Time PO---- 094 093 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 200
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 085 060 030 - 345676249
|
||||
9 Power_On_Hours -O--CK 065 065 000 - 31010
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 198
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 001 001 000 - 145
|
||||
190 Airflow_Temperature_Cel -O---K 065 055 045 - 35 (Min/Max 28/40)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 112
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 266
|
||||
194 Temperature_Celsius -O---K 035 045 000 - 35 (0 18 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xd1 GPL,SL VS 8 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/40 Celsius
|
||||
Lifetime Min/Max Temperature: 18/43 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 94 minutes
|
||||
Min/Max recommended Temperature: 1/61 Celsius
|
||||
Min/Max Temperature Limit: 2/60 Celsius
|
||||
Temperature History Size (Index): 128 (93)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
Reference in New Issue