smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p4 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate BarraCuda 3.5
|
||||
Device Model: ST6000DM003-2CY186
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0001
|
||||
User Capacity: 6,001,175,126,016 bytes [6.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5425 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Dec 1 21:35:19 2021 CST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART Status not supported: Incomplete response, ATA output registers missing
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
Warning: This result is based on an Attribute check.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 747) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x30a5) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 083 064 006 - 189614418
|
||||
3 Spin_Up_Time PO---- 093 092 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 103
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 075 060 045 - 32323913
|
||||
9 Power_On_Hours -O--CK 079 079 000 - 18434 (204 215 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 68
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0 0 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 051 047 040 - 49 (Min/Max 40/52)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 96
|
||||
193 Load_Cycle_Count -O--CK 099 099 000 - 2002
|
||||
194 Temperature_Celsius -O---K 049 053 000 - 49 (0 25 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 083 064 000 - 189614418
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 8692h+56m+54.999s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 6362489687
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 94589892817
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 9048 Device vendor specific log
|
||||
0xbd GPL VS 8 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 24 Device vendor specific log
|
||||
0xd1 GPL VS 264 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 49 Celsius
|
||||
Power Cycle Min/Max Temperature: 40/53 Celsius
|
||||
Lifetime Min/Max Temperature: 24/53 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (26)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 68 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 18434 --- Power-on Hours
|
||||
0x01 0x018 6 6362434902 --- Logical Sectors Written
|
||||
0x01 0x020 6 24670696 --- Number of Write Commands
|
||||
0x01 0x028 6 94627794162 --- Logical Sectors Read
|
||||
0x01 0x030 6 369615526 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 3397799256 N-- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 3397789296 N-- Head Flying Hours
|
||||
0x03 0x018 4 2002 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 96 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 49 --- Current Temperature
|
||||
0x05 0x010 1 49 --- Average Short Term Temperature
|
||||
0x05 0x018 1 45 --- Average Long Term Temperature
|
||||
0x05 0x020 1 53 --- Highest Temperature
|
||||
0x05 0x028 1 0 --- Lowest Temperature
|
||||
0x05 0x030 1 50 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 35 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 46 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 36 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 55 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 300 --- Time in Under-Temperature
|
||||
0x05 0x068 1 13 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 57 --- Number of Hardware Resets
|
||||
0x06 0x010 4 25 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
172
HDD/Seagate/ST6000/ST6000DX000-1H217Z/271EF0F032C5
Normal file
172
HDD/Seagate/ST6000/ST6000DX000-1H217Z/271EF0F032C5
Normal file
@@ -0,0 +1,172 @@
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST6000DX000-1H217Z
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC48
|
||||
User Capacity: 6,001,175,126,016 bytes [6.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Mar 6 12:09:52 2022 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 80) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 635) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 115 099 006 - 84560259
|
||||
3 Spin_Up_Time PO---- 087 086 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 28
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 090 060 030 - 5438068651
|
||||
9 Power_On_Hours -O--CK 054 054 000 - 41091
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 24
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 067 051 045 - 33 (Min/Max 21/33)
|
||||
191 G-Sense_Error_Rate -O--CK 027 027 000 - 147091
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 355269
|
||||
194 Temperature_Celsius -O---K 033 049 000 - 33 (0 17 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 069 048 000 - 84560259
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 33319 (66 49 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 250544770573
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1071969710027
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 8982 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc7 GPL,SL VS 1 Device vendor specific log
|
||||
0xd1 GPL,SL VS 8 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 41080 -
|
||||
# 2 Conveyance offline Completed without error 00% 41079 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/33 Celsius
|
||||
Lifetime Min/Max Temperature: 17/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
172
HDD/Seagate/ST6000/ST6000DX000-1H217Z/3E3DF7C6F474
Normal file
172
HDD/Seagate/ST6000/ST6000DX000-1H217Z/3E3DF7C6F474
Normal file
@@ -0,0 +1,172 @@
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST6000DX000-1H217Z
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC48
|
||||
User Capacity: 6,001,175,126,016 bytes [6.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Mar 6 12:09:52 2022 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 89) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 641) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 108 099 006 - 20036410
|
||||
3 Spin_Up_Time PO---- 087 087 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 30
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 073 060 030 - 207352993687
|
||||
9 Power_On_Hours -O--CK 053 053 000 - 41226
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 27
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 067 050 045 - 33 (Min/Max 22/33)
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 243226
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 357767
|
||||
194 Temperature_Celsius -O---K 033 050 000 - 33 (0 18 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 069 045 000 - 20036410
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 33488 (10 186 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 273639335703
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 768818018015
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 8982 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc7 GPL,SL VS 1 Device vendor specific log
|
||||
0xd1 GPL,SL VS 8 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 41215 -
|
||||
# 2 Conveyance offline Completed without error 00% 41215 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/33 Celsius
|
||||
Lifetime Min/Max Temperature: 18/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 11 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
231
HDD/Seagate/ST6000/ST6000VN0033-2EE110/120898FFC226
Normal file
231
HDD/Seagate/ST6000/ST6000VN0033-2EE110/120898FFC226
Normal file
@@ -0,0 +1,231 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p1 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate IronWolf
|
||||
Device Model: ST6000VN0033-2EE110
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 6,001,175,126,016 bytes [6.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jul 3 10:29:59 2021 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 567) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 615) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 082 064 044 - 153390200
|
||||
3 Spin_Up_Time PO---- 087 086 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 43
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 090 060 045 - 1042130773
|
||||
9 Power_On_Hours -O--CK 074 074 000 - 22806
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 43
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 062 053 040 - 38 (Min/Max 32/40)
|
||||
191 G-Sense_Error_Rate -O--CK 096 096 000 - 8194
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 185
|
||||
193 Load_Cycle_Count -O--CK 029 029 000 - 142137
|
||||
194 Temperature_Celsius -O---K 038 047 000 - 38 (0 22 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 001 001 000 - 153390200
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 19532 (217 18 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 15776307912
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 20300654208
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xb0 GPL VS 9048 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xd1 GPL VS 264 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/40 Celsius
|
||||
Lifetime Min/Max Temperature: 22/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/1842
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (69)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 43 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 22806 --- Power-on Hours
|
||||
0x01 0x018 6 15776395792 --- Logical Sectors Written
|
||||
0x01 0x020 6 515587553 --- Number of Write Commands
|
||||
0x01 0x028 6 20301919600 --- Logical Sectors Read
|
||||
0x01 0x030 6 748667737 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 215500493 N-- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 215497267 N-- Head Flying Hours
|
||||
0x03 0x018 4 142137 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 185 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 38 --- Current Temperature
|
||||
0x05 0x010 1 37 --- Average Short Term Temperature
|
||||
0x05 0x018 1 36 --- Average Long Term Temperature
|
||||
0x05 0x020 1 47 --- Highest Temperature
|
||||
0x05 0x028 1 0 --- Lowest Temperature
|
||||
0x05 0x030 1 44 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 38 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 31 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 267 --- Number of Hardware Resets
|
||||
0x06 0x010 4 47 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
231
HDD/Seagate/ST6000/ST6000VN0033-2EE110/71DFD5A878ED
Normal file
231
HDD/Seagate/ST6000/ST6000VN0033-2EE110/71DFD5A878ED
Normal file
@@ -0,0 +1,231 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p1 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate IronWolf
|
||||
Device Model: ST6000VN0033-2EE110
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 6,001,175,126,016 bytes [6.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jul 3 10:30:00 2021 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 567) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 590) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 084 064 044 - 239382616
|
||||
3 Spin_Up_Time PO---- 087 086 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 43
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 090 060 045 - 1010033683
|
||||
9 Power_On_Hours -O--CK 074 074 000 - 22806
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 43
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 061 053 040 - 39 (Min/Max 33/40)
|
||||
191 G-Sense_Error_Rate -O--CK 090 090 000 - 20876
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 195
|
||||
193 Load_Cycle_Count -O--CK 031 031 000 - 139660
|
||||
194 Temperature_Celsius -O---K 039 047 000 - 39 (0 22 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 001 001 000 - 239382616
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 19534 (59 92 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 16185016216
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 21256477912
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xb0 GPL VS 9048 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xd1 GPL VS 264 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/40 Celsius
|
||||
Lifetime Min/Max Temperature: 22/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/1842
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (69)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 43 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 22806 --- Power-on Hours
|
||||
0x01 0x018 6 16185140080 --- Logical Sectors Written
|
||||
0x01 0x020 6 526174361 --- Number of Write Commands
|
||||
0x01 0x028 6 21257612056 --- Logical Sectors Read
|
||||
0x01 0x030 6 821311151 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 3420872733 N-- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 3420869509 N-- Head Flying Hours
|
||||
0x03 0x018 4 139660 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 195 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 39 --- Current Temperature
|
||||
0x05 0x010 1 38 --- Average Short Term Temperature
|
||||
0x05 0x018 1 37 --- Average Long Term Temperature
|
||||
0x05 0x020 1 47 --- Highest Temperature
|
||||
0x05 0x028 1 0 --- Lowest Temperature
|
||||
0x05 0x030 1 44 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 39 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 31 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 294 --- Number of Hardware Resets
|
||||
0x06 0x010 4 47 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 11 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
231
HDD/Seagate/ST6000/ST6000VN0033-2EE110/763B0CE878D0
Normal file
231
HDD/Seagate/ST6000/ST6000VN0033-2EE110/763B0CE878D0
Normal file
@@ -0,0 +1,231 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p1 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate IronWolf
|
||||
Device Model: ST6000VN0033-2EE110
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 6,001,175,126,016 bytes [6.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jul 3 10:29:59 2021 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 575) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 598) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 073 064 044 - 21867000
|
||||
3 Spin_Up_Time PO---- 087 086 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 43
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 090 060 045 - 1030694489
|
||||
9 Power_On_Hours -O--CK 074 074 000 - 22806
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 43
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 063 056 040 - 37 (Min/Max 31/38)
|
||||
191 G-Sense_Error_Rate -O--CK 097 097 000 - 6247
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 170
|
||||
193 Load_Cycle_Count -O--CK 029 029 000 - 143124
|
||||
194 Temperature_Celsius -O---K 037 044 000 - 37 (0 21 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 001 001 000 - 21867000
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 19530 (185 183 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 15769385256
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 20550067811
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xb0 GPL VS 9048 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xd1 GPL VS 264 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/38 Celsius
|
||||
Lifetime Min/Max Temperature: 21/44 Celsius
|
||||
Under/Over Temperature Limit Count: 0/1842
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (69)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 43 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 22806 --- Power-on Hours
|
||||
0x01 0x018 6 15769404152 --- Logical Sectors Written
|
||||
0x01 0x020 6 514999997 --- Number of Write Commands
|
||||
0x01 0x028 6 20549824003 --- Logical Sectors Read
|
||||
0x01 0x030 6 783670244 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 2734638700 N-- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 2734635472 N-- Head Flying Hours
|
||||
0x03 0x018 4 143124 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 170 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 37 --- Current Temperature
|
||||
0x05 0x010 1 36 --- Average Short Term Temperature
|
||||
0x05 0x018 1 34 --- Average Long Term Temperature
|
||||
0x05 0x020 1 44 --- Highest Temperature
|
||||
0x05 0x028 1 0 --- Lowest Temperature
|
||||
0x05 0x030 1 41 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 27 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 36 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 30 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 203 --- Number of Hardware Resets
|
||||
0x06 0x010 4 49 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
231
HDD/Seagate/ST6000/ST6000VN0033-2EE110/D1CD2A443E76
Normal file
231
HDD/Seagate/ST6000/ST6000VN0033-2EE110/D1CD2A443E76
Normal file
@@ -0,0 +1,231 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p1 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate IronWolf
|
||||
Device Model: ST6000VN0033-2EE110
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 6,001,175,126,016 bytes [6.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jul 3 10:30:01 2021 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 567) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 591) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 077 064 044 - 47122256
|
||||
3 Spin_Up_Time PO---- 087 086 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 43
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 090 060 045 - 1001764599
|
||||
9 Power_On_Hours -O--CK 074 074 000 - 22806
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 43
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 062 056 040 - 38 (Min/Max 32/40)
|
||||
191 G-Sense_Error_Rate -O--CK 099 099 000 - 2149
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 189
|
||||
193 Load_Cycle_Count -O--CK 030 030 000 - 140501
|
||||
194 Temperature_Celsius -O---K 038 044 000 - 38 (0 22 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 001 001 000 - 47122256
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 19534 (186 7 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 16185575736
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 20768273204
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xb0 GPL VS 9048 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xd1 GPL VS 264 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/40 Celsius
|
||||
Lifetime Min/Max Temperature: 22/44 Celsius
|
||||
Under/Over Temperature Limit Count: 0/1843
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (71)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 43 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 22806 --- Power-on Hours
|
||||
0x01 0x018 6 16185592128 --- Logical Sectors Written
|
||||
0x01 0x020 6 525810960 --- Number of Write Commands
|
||||
0x01 0x028 6 20768094116 --- Logical Sectors Read
|
||||
0x01 0x030 6 765016081 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 720246039 N-- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 720242814 N-- Head Flying Hours
|
||||
0x03 0x018 4 140501 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 189 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 38 --- Current Temperature
|
||||
0x05 0x010 1 37 --- Average Short Term Temperature
|
||||
0x05 0x018 1 36 --- Average Long Term Temperature
|
||||
0x05 0x020 1 44 --- Highest Temperature
|
||||
0x05 0x028 1 0 --- Lowest Temperature
|
||||
0x05 0x030 1 41 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 27 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 37 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 30 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 294 --- Number of Hardware Resets
|
||||
0x06 0x010 4 46 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 11 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
Reference in New Issue