smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Momentus 5400.5
|
||||
Device Model: ST980310AS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: DE06
|
||||
User Capacity: 80,026,361,856 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Sun Oct 17 02:29:44 2021 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 32) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 114 099 006 - 62219169
|
||||
3 Spin_Up_Time PO---- 100 096 085 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1834
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 078 060 030 - 69680876
|
||||
9 Power_On_Hours -O--CK 091 091 000 - 8290
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 2
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1625
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 098 098 000 - 2
|
||||
188 Command_Timeout -O--CK 100 099 000 - 3
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 065 045 045 Past 35 (Min/Max 24/48)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 321
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 265
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 201158
|
||||
194 Temperature_Celsius -O---K 035 055 000 - 35 (0 14 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 043 041 000 - 62219169
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 8073 (108 57 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 2389569219
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 864607044
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL,SL R/O 1 Write stream error log
|
||||
0x22 GPL,SL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 20 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2819 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
Device Error Count: 2
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 2 [1] occurred at disk power-on lifetime: 4847 hours (201 days + 23 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 04 1d 00 e0 cb 00 00 Error: UNC at LBA = 0x41d00e0cb = 17666465995
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 00 08 00 04 1d 00 e0 c8 40 00 13d+16:41:29.997 READ FPDMA QUEUED
|
||||
60 00 00 00 18 00 04 1c 00 e0 d0 40 00 13d+16:41:29.993 READ FPDMA QUEUED
|
||||
60 00 00 00 18 00 04 1b 00 e0 50 40 00 13d+16:41:29.990 READ FPDMA QUEUED
|
||||
60 00 00 00 08 00 04 1b 00 e0 48 40 00 13d+16:41:29.968 READ FPDMA QUEUED
|
||||
60 00 00 00 18 00 02 f0 00 55 68 40 00 13d+16:41:29.965 READ FPDMA QUEUED
|
||||
|
||||
Error 1 [0] occurred at disk power-on lifetime: 4847 hours (201 days + 23 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 04 1d 00 e0 cb 00 00 Error: UNC at LBA = 0x41d00e0cb = 17666465995
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 00 08 00 02 f0 00 55 80 40 00 13d+16:41:27.013 READ FPDMA QUEUED
|
||||
60 00 00 00 80 00 04 1d 00 e0 50 40 00 13d+16:41:27.012 READ FPDMA QUEUED
|
||||
60 00 00 00 40 00 04 1d 00 e0 10 40 00 13d+16:41:27.011 READ FPDMA QUEUED
|
||||
60 00 00 00 20 00 04 1c 00 e0 f0 40 00 13d+16:41:27.011 READ FPDMA QUEUED
|
||||
60 00 00 00 08 00 04 1c 00 e0 e8 40 00 13d+16:41:27.010 READ FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 8288 -
|
||||
# 2 Short offline Completed without error 00% 8264 -
|
||||
# 3 Short offline Completed without error 00% 8240 -
|
||||
# 4 Short offline Completed without error 00% 8216 -
|
||||
# 5 Short offline Completed without error 00% 8192 -
|
||||
# 6 Short offline Completed without error 00% 8168 -
|
||||
# 7 Short offline Completed without error 00% 8144 -
|
||||
# 8 Short offline Completed without error 00% 8120 -
|
||||
# 9 Short offline Completed without error 00% 8096 -
|
||||
#10 Short offline Completed without error 00% 8072 -
|
||||
#11 Short offline Completed without error 00% 8048 -
|
||||
#12 Short offline Completed without error 00% 8024 -
|
||||
#13 Short offline Completed without error 00% 8000 -
|
||||
#14 Short offline Completed without error 00% 7976 -
|
||||
#15 Short offline Completed without error 00% 7952 -
|
||||
#16 Short offline Completed without error 00% 7928 -
|
||||
#17 Short offline Completed without error 00% 7904 -
|
||||
#18 Short offline Completed without error 00% 7880 -
|
||||
#19 Short offline Completed without error 00% 7856 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/48 Celsius
|
||||
Lifetime Min/Max Temperature: 14/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (13)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|