smartctl 7.2 2020-12-30 r5155 [OpenBSD 7.0 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: TOSHIBA MK1629GSGF
Serial Number: --
LU WWN Device Id: 5 000039 ...
Firmware Version: PT000D
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Tue Jan 11 02:04:10 2022 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 112) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 109) minutes.
SCT capabilities: (0x0039) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 128
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 094 050 Pre-fail Always - 0
3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 1402
5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 29
9 Power_On_Hours 0x0032 079 079 000 Old_age Always - 506083
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 7290
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 181
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 408
193 Load_Cycle_Count 0x0032 091 091 000 Old_age Always - 96673
194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 46 (Min/Max 11/65)
199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 95877835
200 Multi_Zone_Error_Rate 0x0032 100 100 000 Old_age Always - 152584735
240 Head_Flying_Hours 0x0032 082 082 000 Old_age Always - 441131
241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 11700176253
242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 30372401757
254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 270
SMART Error Log Version: 1
ATA Error Count: 50185 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 50185 occurred at disk power-on lifetime: 8327 hours (346 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 41 0a c8 de b7 69 Error: UNC at LBA = 0x09b7dec8 = 163045064
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 10 01 df b7 40 00 00:31:29.878 READ FPDMA QUEUED
60 00 08 01 de b7 40 00 00:31:29.878 READ FPDMA QUEUED
ef 02 00 00 00 00 00 00 00:31:29.708 SET FEATURES [Enable write cache]
aa aa aa aa aa aa aa ff 00:31:29.498 [RESERVED]
60 00 10 01 df b7 40 00 00:31:25.478 READ FPDMA QUEUED
Error 50184 occurred at disk power-on lifetime: 8327 hours (346 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 41 0a c8 de b7 69 Error: UNC at LBA = 0x09b7dec8 = 163045064
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 10 01 df b7 40 00 00:31:25.478 READ FPDMA QUEUED
60 00 08 01 de b7 40 00 00:31:25.478 READ FPDMA QUEUED
ef 02 00 00 00 00 00 00 00:31:25.308 SET FEATURES [Enable write cache]
aa aa aa aa aa aa aa ff 00:31:25.098 [RESERVED]
60 00 10 01 df b7 40 00 00:31:21.067 READ FPDMA QUEUED
Error 50183 occurred at disk power-on lifetime: 8327 hours (346 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 41 0a c8 de b7 69 Error: UNC at LBA = 0x09b7dec8 = 163045064
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 10 01 df b7 40 00 00:31:21.067 READ FPDMA QUEUED
60 00 08 01 de b7 40 00 00:31:21.067 READ FPDMA QUEUED
ef 02 00 00 00 00 00 00 00:31:20.894 SET FEATURES [Enable write cache]
aa aa aa aa aa aa aa ff 00:31:20.687 [RESERVED]
60 00 10 01 df b7 40 00 00:31:16.656 READ FPDMA QUEUED
Error 50182 occurred at disk power-on lifetime: 8327 hours (346 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 41 0a c8 de b7 69 Error: UNC at LBA = 0x09b7dec8 = 163045064
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 10 01 df b7 40 00 00:31:16.656 READ FPDMA QUEUED
60 00 08 01 de b7 40 00 00:31:16.656 READ FPDMA QUEUED
ef 02 00 00 00 00 00 00 00:31:16.494 SET FEATURES [Enable write cache]
aa aa aa aa aa aa aa ff 00:31:16.276 [RESERVED]
60 00 10 01 df b7 40 00 00:31:12.256 READ FPDMA QUEUED
Error 50181 occurred at disk power-on lifetime: 8327 hours (346 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 41 0a c8 de b7 69 Error: UNC at LBA = 0x09b7dec8 = 163045064
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 10 01 df b7 40 00 00:31:12.256 READ FPDMA QUEUED
60 00 08 01 de b7 40 00 00:31:12.256 READ FPDMA QUEUED
ef 02 00 00 00 00 00 00 00:31:12.095 SET FEATURES [Enable write cache]
aa aa aa aa aa aa aa ff 00:31:11.876 [RESERVED]
60 00 10 01 df b7 40 00 00:31:07.956 READ FPDMA QUEUED
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed: read failure 00% 2558 74098799
# 2 Extended offline Aborted by host 10% 2553 -
# 3 Short offline Completed without error 00% 2550 -
# 4 Short offline Completed without error 00% 2550 -
# 5 Short offline Completed: read failure 00% 2084 39941344
# 6 Short offline Completed: read failure 00% 1336 377777
# 7 Short offline Aborted by host 90% 395 -
# 8 Short offline Aborted by host 90% 395 -
# 9 Short offline Completed without error 00% 209 -
#10 Short offline Aborted by host 90% 3 -
#11 Extended offline Aborted by host 80% 0 -
#12 Short offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.