@@ -0,0 +1,20 @@
BIWIN NVMe Drives
=================
This is a list of all tested BIWIN NVMe drive models and their MTBFs. See more
info on reliability test in the [README](https://github.com/bsdhw/SMART).
NVME by Model
------------
Please take all columns into account when reading the table. Pay attention on the
number of tested samples and power-on days. Simultaneous high values of both MTBF
and errors are possible if only rare drives in the subset encounter errors.
Days — avg. days per sample,
Err — avg. errors per sample,
MTBF — avg. MTBF in years per sample.
| MFG | Model | Size | Samples | Days | Err | MTBF |
|-----------|--------------------|--------|---------|-------|-------|------|
| BIWIN | SSD | 1 TB | 1 | 9 | 0 | 0.03 |

View File

@@ -0,0 +1,65 @@
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-STABLE amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: BIWIN SSD
Serial Number: --
Firmware Version: 42A0S63C
PCI Vendor/Subsystem ID: 0x126f
IEEE OUI Identifier: 0x000000
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 1,024,209,543,168 [1.02 TB]
Namespace 1 Utilization: 355,063,140,352 [355 GB]
Namespace 1 Formatted LBA Size: 512
Local Time is: Sun Jan 30 16:59:29 2022 UTC
Firmware Updates (0x14): 2 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0f): S/H_per_NS Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 75 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 9.00W - - 0 0 0 0 0 0
1 + 4.60W - - 1 1 1 1 0 0
2 + 3.80W - - 2 2 2 2 0 0
3 - 0.0450W - - 3 3 3 3 2000 2000
4 - 0.0040W - - 4 4 4 4 15000 15000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 35 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 0%
Data Units Read: 438,279 [224 GB]
Data Units Written: 1,182,566 [605 GB]
Host Read Commands: 5,635,167
Host Write Commands: 10,661,365
Controller Busy Time: 123
Power Cycles: 133
Power On Hours: 228
Unsafe Shutdowns: 25
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Thermal Temp. 1 Transition Count: 8
Thermal Temp. 2 Transition Count: 2
Thermal Temp. 1 Total Time: 349
Thermal Temp. 2 Total Time: 22
Error Information (NVMe Log 0x01, 16 of 256 entries)
No Errors Logged