smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p4 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Crucial_CT275MX300SSD1
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M0CR021
User Capacity: 275,064,201,216 bytes [275 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Wed Sep 22 10:48:48 2021 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 896) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 5) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 099 000 - 10
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 9
9 Power_On_Hours -O--CK 100 100 000 - 31276
12 Power_Cycle_Count -O--CK 100 100 000 - 272
171 Program_Fail_Count -O--CK 100 100 000 - 1
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Ave_Block-Erase_Count -O--CK 097 097 000 - 46
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 217
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 1
184 Error_Correction_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 064 044 000 - 36 (Min/Max 2/56)
196 Reallocated_Event_Count -O--CK 100 100 000 - 9
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 2
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 221
202 Percent_Lifetime_Remain ----CK 097 097 001 - 3
206 Write_Error_Rate -OSR-- 100 100 000 - 1
246 Total_LBAs_Written -O--CK 100 100 000 - 13750014280
247 Host_Program_Page_Count -O--CK 100 100 000 - 429784500
248 FTL_Program_Page_Count -O--CK 100 100 000 - 216370237
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1234
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 40
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 8000 Current Device Internal Status Data log
0x25 GPL R/O 8000 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 35328 Device vendor specific log
0xa1 GPL,SL VS 3 Device vendor specific log
0xa2 GPL,SL VS 1 Device vendor specific log
0xa3 GPL VS 13824 Device vendor specific log
0xa4 GPL VS 354 Device vendor specific log
0xa4 SL VS 98 Device vendor specific log
0xa5 GPL VS 8000 Device vendor specific log
0xa5 SL VS 64 Device vendor specific log
0xa6 GPL VS 8000 Device vendor specific log
0xa6 SL VS 64 Device vendor specific log
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 31269 -
# 2 Vendor (0xff) Completed without error 00% 31150 -
# 3 Vendor (0xff) Completed without error 00% 31029 -
# 4 Vendor (0xff) Completed without error 00% 30910 -
# 5 Vendor (0xff) Completed without error 00% 30790 -
# 6 Vendor (0xff) Completed without error 00% 30670 -
# 7 Vendor (0xff) Completed without error 00% 30549 -
# 8 Vendor (0xff) Completed without error 00% 30430 -
# 9 Vendor (0xff) Completed without error 00% 30308 -
#10 Vendor (0xff) Completed without error 00% 30188 -
#11 Vendor (0xff) Completed without error 00% 30068 -
#12 Vendor (0xff) Completed without error 00% 29949 -
#13 Vendor (0xff) Completed without error 00% 29830 -
#14 Vendor (0xff) Completed without error 00% 29708 -
#15 Vendor (0xff) Completed without error 00% 29588 -
#16 Vendor (0xff) Completed without error 00% 29453 -
#17 Vendor (0xff) Completed without error 00% 29321 -
#18 Vendor (0xff) Completed without error 00% 29202 -
#19 Vendor (0xff) Completed without error 00% 29080 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Completed [00% left] (41941-107476)
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 28/48 Celsius
Lifetime Min/Max Temperature: 2/56 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (36)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 272 --- Lifetime Power-On Resets
0x01 0x010 4 31276 --- Power-on Hours
0x01 0x018 6 13750014280 --- Logical Sectors Written
0x01 0x020 6 213457171 --- Number of Write Commands
0x01 0x028 6 478617893640 --- Logical Sectors Read
0x01 0x030 6 1902882808 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 285 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 36 --- Current Temperature
0x05 0x010 1 34 --- Average Short Term Temperature
0x05 0x018 1 31 --- Average Long Term Temperature
0x05 0x020 1 56 --- Highest Temperature
0x05 0x028 1 2 --- Lowest Temperature
0x05 0x030 1 47 --- Highest Average Short Term Temperature
0x05 0x038 1 - --- Lowest Average Short Term Temperature
0x05 0x040 1 36 --- Highest Average Long Term Temperature
0x05 0x048 1 30 --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 1958 --- Number of Hardware Resets
0x06 0x010 4 566 --- Number of ASR Events
0x06 0x018 4 221 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 3 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 230 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,223 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p20-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Crucial_CT275MX300SSD1
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M0CR031
User Capacity: 275,064,201,216 bytes [275 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Oct 27 22:03:42 2021 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Unavailable
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 728) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 5) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 4
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 3
9 Power_On_Hours -O--CK 100 100 000 - 7201
12 Power_Cycle_Count -O--CK 100 100 000 - 710
171 Program_Fail_Count -O--CK 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Ave_Block-Erase_Count -O--CK 098 098 000 - 41
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 166
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
184 Error_Correction_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 071 052 000 - 29 (Min/Max 14/48)
196 Reallocated_Event_Count -O--CK 100 100 000 - 3
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
202 Percent_Lifetime_Remain ----CK 098 098 001 - 2
206 Write_Error_Rate -OSR-- 100 100 000 - 0
246 Total_LBAs_Written -O--CK 100 100 000 - 10550524825
247 Host_Program_Page_Count -O--CK 100 100 000 - 330551449
248 FTL_Program_Page_Count -O--CK 100 100 000 - 196619287
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1242
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 16
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 8000 Current Device Internal Status Data log
0x25 GPL R/O 8000 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 35328 Device vendor specific log
0xa1 GPL,SL VS 3 Device vendor specific log
0xa2 GPL,SL VS 1 Device vendor specific log
0xa3 GPL VS 13824 Device vendor specific log
0xa4 GPL VS 354 Device vendor specific log
0xa4 SL VS 98 Device vendor specific log
0xa5 GPL VS 8000 Device vendor specific log
0xa5 SL VS 64 Device vendor specific log
0xa6 GPL VS 8000 Device vendor specific log
0xa6 SL VS 64 Device vendor specific log
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 7041 -
# 2 Vendor (0xff) Completed without error 00% 6961 -
# 3 Vendor (0xff) Completed without error 00% 6847 -
# 4 Vendor (0xff) Completed without error 00% 6724 -
# 5 Vendor (0xff) Completed without error 00% 6644 -
# 6 Vendor (0xff) Completed without error 00% 6605 -
# 7 Vendor (0xff) Completed without error 00% 6458 -
# 8 Vendor (0xff) Completed without error 00% 6373 -
# 9 Vendor (0xff) Completed without error 00% 6277 -
#10 Vendor (0xff) Completed without error 00% 5892 -
#11 Vendor (0xff) Completed without error 00% 5593 -
#12 Vendor (0xff) Completed without error 00% 5380 -
#13 Vendor (0xff) Completed without error 00% 5138 -
#14 Vendor (0xff) Completed without error 00% 4987 -
#15 Vendor (0xff) Completed without error 00% 4893 -
#16 Vendor (0xff) Completed without error 00% 4746 -
#17 Vendor (0xff) Completed without error 00% 4688 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 29 Celsius
Power Cycle Min/Max Temperature: 27/33 Celsius
Lifetime Min/Max Temperature: 14/48 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (335)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 710 --- Lifetime Power-On Resets
0x01 0x010 4 7201 --- Power-on Hours
0x01 0x018 6 10550524825 --- Logical Sectors Written
0x01 0x020 6 127163404 --- Number of Write Commands
0x01 0x028 6 9352335549 --- Logical Sectors Read
0x01 0x030 6 106670014 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 700 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 29 --- Current Temperature
0x05 0x010 1 31 --- Average Short Term Temperature
0x05 0x018 1 30 --- Average Long Term Temperature
0x05 0x020 1 48 --- Highest Temperature
0x05 0x028 1 14 --- Lowest Temperature
0x05 0x030 1 37 --- Highest Average Short Term Temperature
0x05 0x038 1 27 --- Lowest Average Short Term Temperature
0x05 0x040 1 30 --- Highest Average Long Term Temperature
0x05 0x048 1 30 --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 4416 --- Number of Hardware Resets
0x06 0x010 4 733 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 2 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 9 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,211 @@
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.1-RELEASE-p21-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Crucial_CT275MX300SSD1
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M0CR060
User Capacity: 275,064,201,216 bytes [275 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Jan 3 14:57:49 2022 AEDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Unavailable
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 728) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 5) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 100 100 000 - 15644
12 Power_Cycle_Count -O--CK 100 100 000 - 2614
171 Program_Fail_Count -O--CK 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Ave_Block-Erase_Count -O--CK 069 069 000 - 476
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 387
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 2
184 Error_Correction_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 067 049 000 - 33 (Min/Max 11/51)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 1
202 Percent_Lifetime_Remain ----CK 069 069 001 - 31
206 Write_Error_Rate -OSR-- 100 100 000 - 0
246 Total_LBAs_Written -O--CK 100 100 000 - 136283164112
247 Host_Program_Page_Count -O--CK 100 100 000 - 4263524473
248 FTL_Program_Page_Count -O--CK 100 100 000 - 1360553872
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1255
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 8000 Current Device Internal Status Data log
0x25 GPL R/O 8000 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 35328 Device vendor specific log
0xa1 GPL,SL VS 3 Device vendor specific log
0xa2 GPL,SL VS 1 Device vendor specific log
0xa3 GPL VS 13824 Device vendor specific log
0xa4 GPL VS 354 Device vendor specific log
0xa4 SL VS 98 Device vendor specific log
0xa5 GPL VS 8000 Device vendor specific log
0xa5 SL VS 64 Device vendor specific log
0xa6 GPL VS 8000 Device vendor specific log
0xa6 SL VS 64 Device vendor specific log
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 15625 -
# 2 Reserved (0x17) Aborted by host 80% 6168 -
# 3 Reserved (0x18) Aborted by host 80% 6168 -
# 4 Offline Completed without error 00% 0 -
# 5 Offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 31/34 Celsius
Lifetime Min/Max Temperature: 11/51 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (128)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 2614 --- Lifetime Power-On Resets
0x01 0x010 4 15644 --- Power-on Hours
0x01 0x018 6 136283164117 --- Logical Sectors Written
0x01 0x020 6 1353311273 --- Number of Write Commands
0x01 0x028 6 122091274294 --- Logical Sectors Read
0x01 0x030 6 953301080 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 5941 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 33 --- Current Temperature
0x05 0x010 1 0 --- Average Short Term Temperature
0x05 0x018 1 - --- Average Long Term Temperature
0x05 0x020 1 51 --- Highest Temperature
0x05 0x028 1 11 --- Lowest Temperature
0x05 0x030 1 39 --- Highest Average Short Term Temperature
0x05 0x038 1 - --- Lowest Average Short Term Temperature
0x05 0x040 1 0 --- Highest Average Long Term Temperature
0x05 0x048 1 - --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 16577 --- Number of Hardware Resets
0x06 0x010 4 2813 --- Number of ASR Events
0x06 0x018 4 1 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 31 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,313 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p4 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Crucial_CT275MX300SSD1
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M0CR040
User Capacity: 275,064,201,216 bytes [275 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Wed Sep 22 10:48:48 2021 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x06) Offline data collection activity
was aborted by the device with a fatal error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 249) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 5) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 4184
5 Reallocate_NAND_Blk_Cnt -O--CK 080 080 010 - 240
9 Power_On_Hours -O--CK 100 100 000 - 21147
12 Power_Cycle_Count -O--CK 100 100 000 - 173
171 Program_Fail_Count -O--CK 100 100 000 - 17
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Ave_Block-Erase_Count -O--CK 098 098 000 - 39
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 136
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 2
184 Error_Correction_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 27283
194 Temperature_Celsius -O---K 059 043 000 - 41 (Min/Max 17/57)
196 Reallocated_Event_Count -O--CK 100 100 000 - 217
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 15
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 1
202 Percent_Lifetime_Remain ----CK 098 098 001 - 2
206 Write_Error_Rate -OSR-- 100 100 000 - 17
246 Total_LBAs_Written -O--CK 100 100 000 - 11851030953
247 Host_Program_Page_Count -O--CK 100 100 000 - 370703100
248 FTL_Program_Page_Count -O--CK 100 100 000 - 204087426
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1013
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 834
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 8000 Current Device Internal Status Data log
0x25 GPL R/O 8000 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 35328 Device vendor specific log
0xa1 GPL,SL VS 3 Device vendor specific log
0xa2 GPL,SL VS 1 Device vendor specific log
0xa3 GPL VS 13824 Device vendor specific log
0xa4 GPL VS 354 Device vendor specific log
0xa4 SL VS 98 Device vendor specific log
0xa5 GPL VS 8000 Device vendor specific log
0xa5 SL VS 64 Device vendor specific log
0xa6 GPL VS 8000 Device vendor specific log
0xa6 SL VS 64 Device vendor specific log
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
Device Error Count: 27283
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 27283 [27282] log entry is empty
Error 27282 [27281] log entry is empty
Error 27281 [27280] log entry is empty
Error 27280 [27279] log entry is empty
Error 27279 [27278] occurred at disk power-on lifetime: 213 hours (8 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 1b b9 4e bf e0 00 Error: UNC 1 sectors at LBA = 0x1bb94ebf = 465129151
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
Error 27278 [27277] occurred at disk power-on lifetime: 213 hours (8 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 1b b9 4e bf e0 00 Error: UNC 1 sectors at LBA = 0x1bb94ebf = 465129151
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
Error 27277 [27276] occurred at disk power-on lifetime: 213 hours (8 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 1b b9 4e bf e0 00 Error: UNC 1 sectors at LBA = 0x1bb94ebf = 465129151
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
Error 27276 [27275] occurred at disk power-on lifetime: 213 hours (8 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 1b b9 4e bf e0 00 Error: UNC 1 sectors at LBA = 0x1bb94ebf = 465129151
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
25 00 00 00 01 00 00 1b b9 4e bf e0 00 8d+21:02:00.000 READ DMA EXT
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 19804 -
# 2 Vendor (0xff) Completed without error 00% 19699 -
# 3 Vendor (0xff) Completed without error 00% 19578 -
# 4 Vendor (0xff) Completed without error 00% 19458 -
# 5 Vendor (0xff) Completed without error 00% 19324 -
# 6 Vendor (0xff) Completed without error 00% 19191 -
# 7 Vendor (0xff) Completed without error 00% 19070 -
# 8 Vendor (0xff) Completed without error 00% 18951 -
# 9 Vendor (0xff) Completed without error 00% 18831 -
#10 Vendor (0xff) Completed without error 00% 18710 -
#11 Vendor (0xff) Completed without error 00% 18591 -
#12 Vendor (0xff) Completed without error 00% 18471 -
#13 Vendor (0xff) Completed without error 00% 18351 -
#14 Vendor (0xff) Completed without error 00% 18230 -
#15 Vendor (0xff) Completed without error 00% 18110 -
#16 Vendor (0xff) Completed without error 00% 17990 -
#17 Vendor (0xff) Completed without error 00% 17870 -
#18 Vendor (0xff) Completed without error 00% 17751 -
#19 Vendor (0xff) Completed without error 00% 17631 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Completed [00% left] (380395008-380460543)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 41 Celsius
Power Cycle Min/Max Temperature: 29/49 Celsius
Lifetime Min/Max Temperature: 17/57 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (411)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 173 --- Lifetime Power-On Resets
0x01 0x010 4 21147 --- Power-on Hours
0x01 0x018 6 11851030953 --- Logical Sectors Written
0x01 0x020 6 174619096 --- Number of Write Commands
0x01 0x028 6 2278979196 --- Logical Sectors Read
0x01 0x030 6 22346070 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 27283 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 209 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 41 --- Current Temperature
0x05 0x010 1 37 --- Average Short Term Temperature
0x05 0x018 1 41 --- Average Long Term Temperature
0x05 0x020 1 57 --- Highest Temperature
0x05 0x028 1 17 --- Lowest Temperature
0x05 0x030 1 44 --- Highest Average Short Term Temperature
0x05 0x038 1 26 --- Lowest Average Short Term Temperature
0x05 0x040 1 41 --- Highest Average Long Term Temperature
0x05 0x048 1 38 --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 1155 --- Number of Hardware Resets
0x06 0x010 4 315 --- Number of ASR Events
0x06 0x018 4 1 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 2 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 230 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,377 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p4 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Crucial_CT275MX300SSD1
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M0CR021
User Capacity: 275,064,201,216 bytes [275 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Wed Sep 22 10:48:48 2021 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 730) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 5) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 63
5 Reallocate_NAND_Blk_Cnt -O--CK 097 097 010 - 41
9 Power_On_Hours -O--CK 100 100 000 - 23992
12 Power_Cycle_Count -O--CK 100 100 000 - 519
171 Program_Fail_Count -O--CK 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Ave_Block-Erase_Count -O--CK 097 097 000 - 58
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 422
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 2
184 Error_Correction_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 10112
194 Temperature_Celsius -O---K 059 040 000 - 41 (Min/Max 19/60)
196 Reallocated_Event_Count -O--CK 100 100 000 - 41
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 5
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
202 Percent_Lifetime_Remain ----CK 097 097 001 - 3
206 Write_Error_Rate -OSR-- 100 100 000 - 0
246 Total_LBAs_Written -O--CK 100 100 000 - 21613801494
247 Host_Program_Page_Count -O--CK 100 100 000 - 675606780
248 FTL_Program_Page_Count -O--CK 100 100 000 - 196919647
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1197
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 86
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 8000 Current Device Internal Status Data log
0x25 GPL R/O 8000 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 35328 Device vendor specific log
0xa1 GPL,SL VS 3 Device vendor specific log
0xa2 GPL,SL VS 1 Device vendor specific log
0xa3 GPL VS 13824 Device vendor specific log
0xa4 GPL VS 354 Device vendor specific log
0xa4 SL VS 98 Device vendor specific log
0xa5 GPL VS 8000 Device vendor specific log
0xa5 SL VS 64 Device vendor specific log
0xa6 GPL VS 8000 Device vendor specific log
0xa6 SL VS 64 Device vendor specific log
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
Device Error Count: 10112
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 10112 [10111] occurred at disk power-on lifetime: 3563 hours (148 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 1b c3 35 b7 e0 00 Error: UNC 1 sectors at LBA = 0x1bc335b7 = 465778103
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
Error 10111 [10110] occurred at disk power-on lifetime: 3563 hours (148 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 1b c3 35 b7 e0 00 Error: UNC 1 sectors at LBA = 0x1bc335b7 = 465778103
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
Error 10110 [10109] occurred at disk power-on lifetime: 3563 hours (148 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 1b c3 35 b7 e0 00 Error: UNC 1 sectors at LBA = 0x1bc335b7 = 465778103
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
Error 10109 [10108] occurred at disk power-on lifetime: 3563 hours (148 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 1b c3 35 b7 e0 00 Error: UNC 1 sectors at LBA = 0x1bc335b7 = 465778103
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b7 e0 00 49d+01:12:25.408 READ DMA EXT
Error 10108 [10107] occurred at disk power-on lifetime: 3563 hours (148 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 1b c3 35 b6 e0 00 Error: UNC 1 sectors at LBA = 0x1bc335b6 = 465778102
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
Error 10107 [10106] occurred at disk power-on lifetime: 3563 hours (148 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 1b c3 35 b6 e0 00 Error: UNC 1 sectors at LBA = 0x1bc335b6 = 465778102
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
Error 10106 [10105] occurred at disk power-on lifetime: 3563 hours (148 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 1b c3 35 b6 e0 00 Error: UNC 1 sectors at LBA = 0x1bc335b6 = 465778102
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
Error 10105 [10104] occurred at disk power-on lifetime: 3563 hours (148 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 1b c3 35 b6 e0 00 Error: UNC 1 sectors at LBA = 0x1bc335b6 = 465778102
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
25 00 00 00 01 00 00 1b c3 35 b6 e0 00 49d+01:12:25.408 READ DMA EXT
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 23985 -
# 2 Vendor (0xff) Completed without error 00% 23864 -
# 3 Vendor (0xff) Completed without error 00% 23745 -
# 4 Vendor (0xff) Completed without error 00% 23624 -
# 5 Vendor (0xff) Completed without error 00% 23504 -
# 6 Vendor (0xff) Completed without error 00% 23384 -
# 7 Vendor (0xff) Completed without error 00% 23264 -
# 8 Vendor (0xff) Completed without error 00% 23145 -
# 9 Vendor (0xff) Completed without error 00% 23023 -
#10 Vendor (0xff) Completed without error 00% 22904 -
#11 Vendor (0xff) Completed without error 00% 22783 -
#12 Vendor (0xff) Completed without error 00% 22666 -
#13 Vendor (0xff) Completed without error 00% 22543 -
#14 Vendor (0xff) Completed without error 00% 22424 -
#15 Vendor (0xff) Completed without error 00% 22303 -
#16 Vendor (0xff) Completed without error 00% 22169 -
#17 Vendor (0xff) Completed without error 00% 22036 -
#18 Vendor (0xff) Completed without error 00% 21916 -
#19 Vendor (0xff) Completed without error 00% 21795 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Completed [00% left] (534323817-534389352)
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 41 Celsius
Power Cycle Min/Max Temperature: 33/55 Celsius
Lifetime Min/Max Temperature: 19/60 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (284)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 519 --- Lifetime Power-On Resets
0x01 0x010 4 23992 --- Power-on Hours
0x01 0x018 6 21613801494 --- Logical Sectors Written
0x01 0x020 6 235975921 --- Number of Write Commands
0x01 0x028 6 10584314635 --- Logical Sectors Read
0x01 0x030 6 222026562 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 10112 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 651 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 41 --- Current Temperature
0x05 0x010 1 39 --- Average Short Term Temperature
0x05 0x018 1 32 --- Average Long Term Temperature
0x05 0x020 1 60 --- Highest Temperature
0x05 0x028 1 19 --- Lowest Temperature
0x05 0x030 1 44 --- Highest Average Short Term Temperature
0x05 0x038 1 - --- Lowest Average Short Term Temperature
0x05 0x040 1 40 --- Highest Average Long Term Temperature
0x05 0x048 1 32 --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 6051 --- Number of Hardware Resets
0x06 0x010 4 1810 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 3 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 230 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,219 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p20-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Crucial_CT275MX300SSD1
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M0CR031
User Capacity: 275,064,201,216 bytes [275 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Oct 13 23:10:06 2021 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x06) Offline data collection activity
was aborted by the device with a fatal error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 951) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 5) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 001 001 000 - 2698
5 Reallocate_NAND_Blk_Cnt -O--CK 074 074 010 - 274
9 Power_On_Hours -O--CK 100 100 000 - 7984
12 Power_Cycle_Count -O--CK 100 100 000 - 246
171 Program_Fail_Count -O--CK 100 100 000 - 2
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Ave_Block-Erase_Count -O--CK 071 071 000 - 442
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 156
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
184 Error_Correction_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 069 046 000 - 31 (Min/Max 18/54)
196 Reallocated_Event_Count -O--CK 100 100 000 - 252
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 13
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
202 Percent_Lifetime_Remain ----CK 071 071 001 - 29
206 Write_Error_Rate -OSR-- 100 100 000 - 2
246 Total_LBAs_Written -O--CK 100 100 000 - 82974072100
247 Host_Program_Page_Count -O--CK 100 100 000 - 2677938967
248 FTL_Program_Page_Count -O--CK 100 100 000 - 2703152402
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 976
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 1286
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 8000 Current Device Internal Status Data log
0x25 GPL R/O 8000 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 35328 Device vendor specific log
0xa1 GPL,SL VS 3 Device vendor specific log
0xa2 GPL,SL VS 1 Device vendor specific log
0xa3 GPL VS 13824 Device vendor specific log
0xa4 GPL VS 354 Device vendor specific log
0xa4 SL VS 98 Device vendor specific log
0xa5 GPL VS 8000 Device vendor specific log
0xa5 SL VS 64 Device vendor specific log
0xa6 GPL VS 8000 Device vendor specific log
0xa6 SL VS 64 Device vendor specific log
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 7747 -
# 2 Vendor (0xff) Completed without error 00% 7438 -
# 3 Vendor (0xff) Completed without error 00% 7206 -
# 4 Vendor (0xff) Completed without error 00% 5742 -
# 5 Vendor (0xff) Completed without error 00% 4687 -
# 6 Vendor (0xff) Completed without error 00% 3500 -
# 7 Vendor (0xff) Completed without error 00% 3458 -
# 8 Vendor (0xff) Completed without error 00% 3260 -
# 9 Vendor (0xff) Completed without error 00% 3094 -
#10 Vendor (0xff) Completed without error 00% 1003 -
#11 Vendor (0xff) Completed without error 00% 965 -
#12 Vendor (0xff) Completed without error 00% 770 -
#13 Vendor (0xff) Completed without error 00% 433 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 31 Celsius
Power Cycle Min/Max Temperature: 28/36 Celsius
Lifetime Min/Max Temperature: 18/54 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (189)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 246 --- Lifetime Power-On Resets
0x01 0x010 4 7984 --- Power-on Hours
0x01 0x018 6 82974072100 --- Logical Sectors Written
0x01 0x020 6 890613205 --- Number of Write Commands
0x01 0x028 6 26605093424 --- Logical Sectors Read
0x01 0x030 6 386493349 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 259 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 31 --- Current Temperature
0x05 0x010 1 30 --- Average Short Term Temperature
0x05 0x018 1 - --- Average Long Term Temperature
0x05 0x020 1 54 --- Highest Temperature
0x05 0x028 1 18 --- Lowest Temperature
0x05 0x030 1 44 --- Highest Average Short Term Temperature
0x05 0x038 1 23 --- Lowest Average Short Term Temperature
0x05 0x040 1 - --- Highest Average Long Term Temperature
0x05 0x048 1 - --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 883 --- Number of Hardware Resets
0x06 0x010 4 91 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 29 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,225 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Crucial_CT275MX300SSD4
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M0CR070
User Capacity: 275,064,201,216 bytes [275 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: < 1.8 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat Sep 4 11:24:02 2021 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 728) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 5) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 100 100 000 - 12674
12 Power_Cycle_Count -O--CK 100 100 000 - 245
171 Program_Fail_Count -O--CK 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Ave_Block-Erase_Count -O--CK 092 092 000 - 121
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 166
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
184 Error_Correction_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 054 037 000 - 46 (Min/Max 19/63)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
202 Percent_Lifetime_Remain ----CK 092 092 001 - 8
206 Write_Error_Rate -OSR-- 100 100 000 - 0
246 Total_LBAs_Written -O--CK 100 100 000 - 19699229496
247 Host_Program_Page_Count -O--CK 100 100 000 - 615893378
248 FTL_Program_Page_Count -O--CK 100 100 000 - 659601659
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1262
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 8000 Current Device Internal Status Data log
0x25 GPL R/O 8000 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 35328 Device vendor specific log
0xa1 GPL,SL VS 3 Device vendor specific log
0xa2 GPL,SL VS 1 Device vendor specific log
0xa3 GPL VS 13824 Device vendor specific log
0xa4 GPL VS 354 Device vendor specific log
0xa4 SL VS 98 Device vendor specific log
0xa5 GPL VS 8000 Device vendor specific log
0xa5 SL VS 64 Device vendor specific log
0xa6 GPL VS 8000 Device vendor specific log
0xa6 SL VS 64 Device vendor specific log
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 12543 -
# 2 Vendor (0xff) Completed without error 00% 12466 -
# 3 Vendor (0xff) Completed without error 00% 12349 -
# 4 Vendor (0xff) Completed without error 00% 12238 -
# 5 Vendor (0xff) Completed without error 00% 12118 -
# 6 Short offline Completed without error 00% 12018 -
# 7 Short offline Completed without error 00% 11999 -
# 8 Short offline Completed without error 00% 11922 -
# 9 Short offline Completed without error 00% 11898 -
#10 Short offline Completed without error 00% 11874 -
#11 Vendor (0xff) Completed without error 00% 11870 -
#12 Short offline Completed without error 00% 11850 -
#13 Short offline Completed without error 00% 11826 -
#14 Short offline Completed without error 00% 11802 -
#15 Extended offline Completed without error 00% 11778 -
#16 Short offline Completed without error 00% 11754 -
#17 Short offline Completed without error 00% 11730 -
#18 Short offline Completed without error 00% 11706 -
#19 Short offline Completed without error 00% 11682 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 46 Celsius
Power Cycle Min/Max Temperature: 22/63 Celsius
Lifetime Min/Max Temperature: 19/63 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (394)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 245 --- Lifetime Power-On Resets
0x01 0x010 4 12674 --- Power-on Hours
0x01 0x018 6 19699229496 --- Logical Sectors Written
0x01 0x020 6 311024762 --- Number of Write Commands
0x01 0x028 6 3653047895 --- Logical Sectors Read
0x01 0x030 6 84195561 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 242 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 46 --- Current Temperature
0x05 0x010 1 40 --- Average Short Term Temperature
0x05 0x018 1 - --- Average Long Term Temperature
0x05 0x020 1 63 --- Highest Temperature
0x05 0x028 1 19 --- Lowest Temperature
0x05 0x030 1 48 --- Highest Average Short Term Temperature
0x05 0x038 1 37 --- Lowest Average Short Term Temperature
0x05 0x040 1 - --- Highest Average Long Term Temperature
0x05 0x048 1 - --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 2169 --- Number of Hardware Resets
0x06 0x010 4 240 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 8 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 55 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,218 @@
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.1-RELEASE-p21-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Crucial_CT275MX300SSD4
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M0CR040
User Capacity: 275,064,201,216 bytes [275 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: < 1.8 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat Jan 22 13:44:21 2022 AEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x06) Offline data collection activity
was aborted by the device with a fatal error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 1047) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 6) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 3704
5 Reallocate_NAND_Blk_Cnt -O--CK 093 093 010 - 87
9 Power_On_Hours -O--CK 100 100 000 - 5194
12 Power_Cycle_Count -O--CK 100 100 000 - 277
171 Program_Fail_Count -O--CK 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Ave_Block-Erase_Count -O--CK 094 094 000 - 91
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 115
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
184 Error_Correction_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 043 032 000 - 57 (Min/Max 15/68)
196 Reallocated_Event_Count -O--CK 100 100 000 - 87
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 1
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
202 Percent_Lifetime_Remain ----CK 094 094 001 - 6
206 Write_Error_Rate -OSR-- 100 100 000 - 0
246 Total_LBAs_Written -O--CK 100 100 000 - 18734673048
247 Host_Program_Page_Count -O--CK 100 100 000 - 588560047
248 FTL_Program_Page_Count -O--CK 100 100 000 - 570666865
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1169
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 924
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 8000 Current Device Internal Status Data log
0x25 GPL R/O 8000 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 35328 Device vendor specific log
0xa1 GPL,SL VS 3 Device vendor specific log
0xa2 GPL,SL VS 1 Device vendor specific log
0xa3 GPL VS 13824 Device vendor specific log
0xa4 GPL VS 354 Device vendor specific log
0xa4 SL VS 98 Device vendor specific log
0xa5 GPL VS 8000 Device vendor specific log
0xa5 SL VS 64 Device vendor specific log
0xa6 GPL VS 8000 Device vendor specific log
0xa6 SL VS 64 Device vendor specific log
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 5140 -
# 2 Vendor (0xff) Completed without error 00% 5089 -
# 3 Vendor (0xff) Completed without error 00% 5044 -
# 4 Vendor (0xff) Completed without error 00% 4493 -
# 5 Vendor (0xff) Completed without error 00% 4283 -
# 6 Vendor (0xff) Completed without error 00% 4141 -
# 7 Vendor (0xff) Completed without error 00% 3703 -
# 8 Vendor (0xff) Completed without error 00% 2615 -
# 9 Vendor (0xff) Completed without error 00% 2130 -
#10 Vendor (0xff) Completed without error 00% 2026 -
#11 Vendor (0xff) Completed without error 00% 1849 -
#12 Vendor (0xff) Completed without error 00% 1702 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 57 Celsius
Power Cycle Min/Max Temperature: 32/63 Celsius
Lifetime Min/Max Temperature: 15/68 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (204)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 277 --- Lifetime Power-On Resets
0x01 0x010 4 5194 --- Power-on Hours
0x01 0x018 6 18734673048 --- Logical Sectors Written
0x01 0x020 6 402302490 --- Number of Write Commands
0x01 0x028 6 17831372415 --- Logical Sectors Read
0x01 0x030 6 212823977 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 570 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 57 --- Current Temperature
0x05 0x010 1 54 --- Average Short Term Temperature
0x05 0x018 1 - --- Average Long Term Temperature
0x05 0x020 1 68 --- Highest Temperature
0x05 0x028 1 15 --- Lowest Temperature
0x05 0x030 1 58 --- Highest Average Short Term Temperature
0x05 0x038 1 39 --- Lowest Average Short Term Temperature
0x05 0x040 1 - --- Highest Average Long Term Temperature
0x05 0x048 1 - --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 1026 --- Number of Hardware Resets
0x06 0x010 4 146 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 6 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 22 Device-to-host register FISes sent due to a COMRESET