smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p20-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Intel 730 and DC S35x0/3610/3700 Series SSDs
Device Model: INTEL SSDSC2BP240G4
Serial Number: --
LU WWN Device Id: 5 5cd2e4 ...
Firmware Version: L2010410
User Capacity: 240,057,409,536 bytes [240 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Nov 9 03:42:28 2021 IST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x79) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 2) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct -O--CK 097 097 000 - 0
9 Power_On_Hours -O--CK 100 100 000 - 44754
12 Power_Cycle_Count -O--CK 100 100 000 - 2508
170 Available_Reservd_Space PO--CK 100 100 010 - 0
171 Program_Fail_Count -O--CK 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
174 Unsafe_Shutdown_Count -O--CK 100 100 000 - 514
175 Power_Loss_Cap_Test PO--CK 100 100 010 - 622 (153 9724)
183 SATA_Downshift_Count -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 090 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
190 Temperature_Case -O---K 062 062 000 - 38 (Min/Max 35/40)
192 Unsafe_Shutdown_Count -O--CK 100 100 000 - 514
194 Temperature_Internal -O---K 100 100 000 - 38
197 Current_Pending_Sector -O--CK 100 100 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 5
225 Host_Writes_32MiB -O--CK 100 100 000 - 739269
226 Workld_Media_Wear_Indic -O--CK 100 100 000 - 204
227 Workld_Host_Reads_Perc -O--CK 100 100 000 - 35
228 Workload_Minutes -O--CK 100 100 000 - 9724
232 Available_Reservd_Space PO--CK 100 100 010 - 0
233 Media_Wearout_Indicator -O--CK 095 095 000 - 0
234 Thermal_Throttle -O--CK 100 100 000 - 0/0
241 Host_Writes_32MiB -O--CK 100 100 000 - 739269
242 Host_Reads_32MiB -O--CK 100 100 000 - 349644
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 8 Comprehensive SMART error log
0x03 GPL,SL R/O 20 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 2 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xb0 GPL,SL VS 1 Device vendor specific log
0xb1 GPL,SL VS 33 Device vendor specific log
0xd1 GPL VS 13056 Device vendor specific log
0xdf GPL VS 1152 Device vendor specific log
0xdf SL VS 128 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (20 sectors)
Device Error Count: 15
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Warning! SMART Extended Comprehensive Error Log Structure error: invalid SMART checksum.
Error 15 [14] occurred at disk power-on lifetime: 31965 hours (1331 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 01 00 00 00 05 6c db c0 40 00 Error: ABRT at LBA = 0x056cdbc0 = 91020224
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 00 01 00 00 00 05 6c db c0 40 00 00:06:14.344 WRITE FPDMA QUEUED
61 00 00 01 00 00 00 05 6c da c0 40 00 00:06:14.344 WRITE FPDMA QUEUED
61 00 00 01 00 00 00 05 6c d9 c0 40 00 00:06:14.343 WRITE FPDMA QUEUED
61 00 00 01 00 00 00 05 6c d8 c0 40 00 00:06:14.343 WRITE FPDMA QUEUED
61 00 00 01 00 00 00 05 6c d7 c0 40 00 00:06:14.343 WRITE FPDMA QUEUED
Error 14 [13] occurred at disk power-on lifetime: 28322 hours (1180 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 41 01 00 00 00 0d 01 fe f2 40 00 Error: ICRC, ABRT at LBA = 0x0d01fef2 = 218234610
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 01 00 00 00 0d 01 fe f2 40 00 1d+09:16:05.769 READ FPDMA QUEUED
60 00 00 01 00 00 00 0d 01 fd f2 40 00 1d+09:16:05.769 READ FPDMA QUEUED
60 00 00 01 00 00 00 0d 01 fc f2 40 00 1d+09:16:05.766 READ FPDMA QUEUED
60 00 00 01 00 00 00 0d 01 fb f2 40 00 1d+09:16:05.765 READ FPDMA QUEUED
60 00 00 01 00 00 00 0d 01 f9 f2 40 00 1d+09:16:05.763 READ FPDMA QUEUED
Error 13 [12] occurred at disk power-on lifetime: 22020 hours (917 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 41 00 40 00 00 18 b1 ab 98 40 00 Error: ICRC, ABRT at LBA = 0x18b1ab98 = 414296984
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 40 00 00 18 b1 ab 98 40 00 10d+18:14:04.936 READ FPDMA QUEUED
60 00 00 00 20 00 00 11 ae 1d 80 40 00 10d+18:14:04.935 READ FPDMA QUEUED
60 00 00 00 20 00 00 11 ae 93 f8 40 00 10d+18:14:04.935 READ FPDMA QUEUED
60 00 00 00 28 00 00 18 b0 ee 60 40 00 10d+18:14:04.935 READ FPDMA QUEUED
60 00 00 00 18 00 00 11 ac d1 c0 40 00 10d+18:14:04.935 READ FPDMA QUEUED
Warning! SMART Extended Comprehensive Error Log Structure error: invalid SMART checksum.
Error 12 [11] occurred at disk power-on lifetime: 10226 hours (426 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 51 00 08 00 00 02 54 ff a8 40 00 Error: at LBA = 0x0254ffa8 = 39124904
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 02 54 ff a8 40 00 00:01:09.777 READ FPDMA QUEUED
60 00 00 00 18 00 00 00 cc d1 88 40 00 00:01:09.776 READ FPDMA QUEUED
60 00 00 00 08 00 00 04 d0 6c cb 40 00 00:01:09.776 READ FPDMA QUEUED
60 00 00 00 20 00 00 04 d0 6c 12 40 00 00:01:09.776 READ FPDMA QUEUED
60 00 00 00 08 00 00 04 d0 6a a2 40 00 00:01:09.776 READ FPDMA QUEUED
Error 11 [10] occurred at disk power-on lifetime: 7919 hours (329 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 41 00 08 00 00 00 a5 cb 90 40 00 Error: ICRC, ABRT at LBA = 0x00a5cb90 = 10865552
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 00 a5 cb 90 40 00 00:45:59.789 READ FPDMA QUEUED
60 00 00 00 8e 00 00 00 7f 6d c8 40 00 00:45:59.737 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 7f 6d c0 40 00 00:45:59.736 READ FPDMA QUEUED
60 00 00 00 a0 00 00 00 b5 66 c8 40 00 00:45:59.684 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 b5 66 c0 40 00 00:45:59.684 READ FPDMA QUEUED
Error 10 [9] occurred at disk power-on lifetime: 7390 hours (307 days + 22 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 51 00 08 00 00 17 63 41 e8 40 00 Error: at LBA = 0x176341e8 = 392380904
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 17 63 41 e8 40 00 00:00:01.865 READ FPDMA QUEUED
ef 00 66 00 00 00 00 00 00 00 00 a0 00 00:00:01.865 SET FEATURES [Disable revert defaults]
Error 9 [8] occurred at disk power-on lifetime: 4616 hours (192 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 51 00 08 00 00 08 2f 17 f0 40 00 Error: at LBA = 0x082f17f0 = 137304048
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 08 2f 17 f0 40 00 00:41:58.910 READ FPDMA QUEUED
60 00 00 00 08 00 00 08 4c 1d 98 40 00 00:41:58.909 READ FPDMA QUEUED
60 00 00 00 08 00 00 08 23 c5 d0 40 00 00:41:58.908 READ FPDMA QUEUED
60 00 00 00 08 00 00 08 20 2f 70 40 00 00:41:58.908 READ FPDMA QUEUED
60 00 00 00 08 00 00 08 1f 5a f8 40 00 00:41:58.908 READ FPDMA QUEUED
Warning! SMART Extended Comprehensive Error Log Structure error: invalid SMART checksum.
Error 8 [7] occurred at disk power-on lifetime: 3725 hours (155 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 51 00 38 00 00 02 50 52 a8 40 00 Error: at LBA = 0x025052a8 = 38818472
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 38 00 00 02 50 52 a8 40 00 00:01:01.511 READ FPDMA QUEUED
60 00 00 00 38 00 00 02 50 52 a8 40 00 00:01:01.510 READ FPDMA QUEUED
60 00 00 00 38 00 00 02 50 52 a8 40 00 00:01:01.509 READ FPDMA QUEUED
60 00 00 00 38 00 00 02 50 52 a8 40 00 00:01:01.509 READ FPDMA QUEUED
60 00 00 00 38 00 00 02 50 52 a8 40 00 00:01:01.508 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (2 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 38 Celsius
Power Cycle Min/Max Temperature: 35/40 Celsius
Lifetime Min/Max Temperature: 4/45 Celsius
Specified Max Operating Temperature: 70 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
00 00 5f 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 478 (18)
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 2508 --- Lifetime Power-On Resets
0x01 0x018 6 48448792146 --- Logical Sectors Written
0x01 0x020 6 25573446 --- Number of Write Commands
0x01 0x028 6 22914317598 --- Logical Sectors Read
0x01 0x030 6 14039609 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 2 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 38 --- Current Temperature
0x05 0x010 1 37 --- Average Short Term Temperature
0x05 0x018 1 36 --- Average Long Term Temperature
0x05 0x020 1 45 --- Highest Temperature
0x05 0x028 1 16 --- Lowest Temperature
0x05 0x030 1 39 --- Highest Average Short Term Temperature
0x05 0x038 1 19 --- Lowest Average Short Term Temperature
0x05 0x040 1 37 --- Highest Average Long Term Temperature
0x05 0x048 1 22 --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 3862 --- Number of Hardware Resets
0x06 0x010 4 3804 --- Number of ASR Events
0x06 0x018 4 5 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 5 --- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0003 4 0 R_ERR response for device-to-host data FIS
0x0004 4 0 R_ERR response for host-to-device data FIS
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS