1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 3637, modified: 0)

This commit is contained in:
Andrey Ponomarenko
2022-03-18 23:39:11 +03:00
parent 9495463568
commit b1c41e7edc
3830 changed files with 648855 additions and 4579 deletions

View File

@@ -0,0 +1,117 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p20-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: JMicron/Maxiotek based SSDs
Device Model: TS64GSSD25S-M
Serial Number: --
Firmware Version: 120820E
User Capacity: 64,023,257,088 bytes [64.0 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Tue Sep 28 22:33:57 2021 +05
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 30) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 1) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 16777215
2 Throughput_Performance P-S--- 100 100 050 - 0
3 Unknown_JMF_Attribute POS--- 100 100 050 - 0
5 Reallocated_Sector_Ct PO--C- 100 100 050 - 0
7 Unknown_JMF_Attribute PO-R-- 100 100 050 - 0
8 Unknown_JMF_Attribute P-S--- 100 100 050 - 0
9 Power_On_Hours -O--C- 100 100 000 - 8975
10 Unknown_JMF_Attribute PO--C- 100 100 050 - 0
12 Power_Cycle_Count -O--C- 100 100 000 - 97
168 SATA_Phy_Error_Count -O--C- 100 100 000 - 0
175 Bad_Cluster_Table_Count PO---- 100 100 010 - 40
192 Unexpect_Power_Loss_Ct -O--C- 100 100 000 - 0
194 Temperature_Celsius -O---K 038 100 000 - 38 (Min/Max 33/42)
197 Current_Pending_Sector -O--C- 100 100 000 - 0
240 Unknown_JMF_Attribute PO--C- 100 100 050 - 0
170 Bad_Block_Count PO---- 100 100 010 - 40 95 10
173 Erase_Count -O--C- 100 100 000 - 2 653 424
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 64 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Selective Self-tests/Logging not supported
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,115 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p19-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: JMicron/Maxiotek based SSDs
Device Model: TS64GSSD25S-M
Serial Number: --
Firmware Version: 101028
User Capacity: 64,023,257,088 bytes [64.0 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Sun Aug 8 15:31:47 2021 SAST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 163) Reserved.
Total time to complete Offline
data collection: ( 30) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 1) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 16777215
2 Throughput_Performance P-S--- 100 100 050 - 0
3 Unknown_JMF_Attribute POS--- 100 100 050 - 0
5 Reallocated_Sector_Ct PO--C- 100 100 050 - 0
7 Unknown_JMF_Attribute PO-R-- 100 100 050 - 0
8 Unknown_JMF_Attribute P-S--- 100 100 050 - 0
9 Power_On_Hours -O--C- 100 100 000 - 16601
10 Unknown_JMF_Attribute PO--C- 100 100 050 - 0
12 Power_Cycle_Count -O--C- 100 100 000 - 641
168 SATA_Phy_Error_Count -O--C- 100 100 000 - 0
175 Bad_Cluster_Table_Count PO---- 100 100 010 - 11
192 Unexpect_Power_Loss_Ct -O--C- 100 100 000 - 0
194 Temperature_Celsius -O---K 042 100 000 - 42 (Min/Max 38/42)
197 Current_Pending_Sector -O--C- 100 100 000 - 0
240 Unknown_JMF_Attribute PO--C- 100 100 050 - 0
170 Bad_Block_Count PO---- 100 100 010 - 11 130 23
173 Erase_Count -O--C- 100 100 000 - 4 10557 7821
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 64 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Selective Self-tests/Logging not supported
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET