mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 707)
This commit is contained in:
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Sun Jan 2 01:00:03 2022 PST
|
||||
Local Time is: Sun Jan 16 01:00:03 2022 PST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -20,7 +20,7 @@ APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
@@ -30,9 +30,8 @@ General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Self-test execution status: ( 249) Self-test routine in progress...
|
||||
90% of test remaining.
|
||||
Total time to complete Offline
|
||||
data collection: (32280) seconds.
|
||||
Offline data collection
|
||||
@@ -64,17 +63,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 204 179 021 - 4791
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1852
|
||||
3 Spin_Up_Time POS--K 181 179 021 - 5916
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1859
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 062 062 000 - 28181
|
||||
9 Power_On_Hours -O--CK 062 062 000 - 28309
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1849
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 777
|
||||
193 Load_Cycle_Count -O--CK 019 019 000 - 544993
|
||||
194 Temperature_Celsius -O---K 120 107 000 - 30
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1856
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 781
|
||||
193 Load_Cycle_Count -O--CK 018 018 000 - 546446
|
||||
194 Temperature_Celsius -O---K 114 107 000 - 36
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -112,24 +111,24 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 28014 -
|
||||
# 2 Extended offline Completed without error 00% 27852 -
|
||||
# 3 Short offline Completed without error 00% 27846 -
|
||||
# 4 Short offline Completed without error 00% 27485 -
|
||||
# 5 Extended offline Completed without error 00% 27426 -
|
||||
# 6 Extended offline Completed without error 00% 27380 -
|
||||
# 7 Extended offline Completed without error 00% 27214 -
|
||||
# 8 Extended offline Completed without error 00% 27049 -
|
||||
# 9 Extended offline Completed without error 00% 26883 -
|
||||
#10 Extended offline Completed without error 00% 26716 -
|
||||
#11 Extended offline Completed without error 00% 26552 -
|
||||
#12 Extended offline Completed without error 00% 26386 -
|
||||
#13 Extended offline Completed without error 00% 26222 -
|
||||
#14 Extended offline Completed without error 00% 26056 -
|
||||
#15 Extended offline Completed without error 00% 25984 -
|
||||
#16 Extended offline Completed without error 00% 25891 -
|
||||
#17 Extended offline Completed without error 00% 25725 -
|
||||
#18 Extended offline Completed without error 00% 25560 -
|
||||
# 1 Short offline Completed without error 00% 28308 -
|
||||
# 2 Short offline Completed without error 00% 28182 -
|
||||
# 3 Short offline Completed without error 00% 28014 -
|
||||
# 4 Extended offline Completed without error 00% 27852 -
|
||||
# 5 Short offline Completed without error 00% 27846 -
|
||||
# 6 Short offline Completed without error 00% 27485 -
|
||||
# 7 Extended offline Completed without error 00% 27426 -
|
||||
# 8 Extended offline Completed without error 00% 27380 -
|
||||
# 9 Extended offline Completed without error 00% 27214 -
|
||||
#10 Extended offline Completed without error 00% 27049 -
|
||||
#11 Extended offline Completed without error 00% 26883 -
|
||||
#12 Extended offline Completed without error 00% 26716 -
|
||||
#13 Extended offline Completed without error 00% 26552 -
|
||||
#14 Extended offline Completed without error 00% 26386 -
|
||||
#15 Extended offline Completed without error 00% 26222 -
|
||||
#16 Extended offline Completed without error 00% 26056 -
|
||||
#17 Extended offline Completed without error 00% 25984 -
|
||||
#18 Extended offline Completed without error 00% 25891 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -144,10 +143,10 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/37 Celsius
|
||||
Lifetime Min/Max Temperature: ?/43 Celsius
|
||||
Device State: DST executing in background (3)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/41 Celsius
|
||||
Lifetime Min/Max Temperature: 36/43 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -155,7 +154,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (474)
|
||||
Temperature History Size (Index): 478 (36)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -174,9 +173,9 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 2111961 Vendor specific
|
||||
0x8000 4 43944 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
Reference in New Issue