@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p7-HBSD amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p19-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -11,7 +11,7 @@ User Capacity: 160,041,885,696 bytes [160 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Thu Jul 1 12:11:23 2021 CDT
|
||||
Local Time is: Sun Jul 25 17:20:47 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -63,17 +63,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
|
||||
3 Spin_Up_Time PO---- 186 184 021 - 1683
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1812
|
||||
3 Spin_Up_Time PO---- 186 184 021 - 1700
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1820
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 057 057 000 - 32067
|
||||
9 Power_On_Hours -O--CK 056 056 000 - 32593
|
||||
10 Spin_Retry_Count -O--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1648
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 120
|
||||
193 Load_Cycle_Count -O--CK 145 145 000 - 165403
|
||||
194 Temperature_Celsius -O---K 093 091 000 - 54
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1656
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 123
|
||||
193 Load_Cycle_Count -O--CK 145 145 000 - 165446
|
||||
194 Temperature_Celsius -O---K 105 091 000 - 42
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 253 000 - 0
|
||||
@@ -127,8 +127,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: --/32 Celsius
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: --/38 Celsius
|
||||
Lifetime Min/Max Temperature: --/ 0 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -136,7 +136,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/65 Celsius
|
||||
Min/Max Temperature Limit: 1/70 Celsius
|
||||
Temperature History Size (Index): 128 (3)
|
||||
Temperature History Size (Index): 128 (19)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -155,8 +155,8 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 11 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 1687046 Vendor specific
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 311567 Vendor specific
|
||||
|
||||
|
||||
|
||||
|